sane-project-backends/backend/mustek_pp_ccd.conf

106 wiersze
2.6 KiB
Plaintext

# For documentation see sane-mustek_pp_ccd(5)
# GLOBAL #
# option io-mode [mode] must come before all port definitions, or it won't
# have the effect you'd expect
# enable this option, if you think your scanner supports the UNI protocol
# note however that this might disable the better EPP protocol
#option io-mode try_mode_uni
# choose between two different ways to lock to port
option io-mode alt_lock
# set the maximal height (in lines) of a strip scanned (default: no limit)
#option strip-height 0
# wait n msecs for bank to change (default: 700 msecs)
# if this value is to low, stripes my appear in the scanned image
#option wait-bank 700
# size (in bytes) of scan buffer (default: 1 megabyte)
#option buffer 1048576
# try to avoid to heavy load. Note that this reduces scan speed
option niceload
# Define the time the lamp has to be on before scan starts (default 5 secs)
#option wait-lamp 5
# DEVICES #
# specify the port your scanner is connected to. Possible are 0x378 (lp1)
# 0x278 (lp2) and 0x3bc (lp0)
# for 2.4.x+ kernels, this isn't true anymore. Here lp0 is assigned to the
# first available port, normally 0x378
#
# If libieee1284 is available, "parport0" and similar libieee1284 device names
# will also work.
port 0x378
# port parport0
# the following options are local to this scanner
# WELL KNOWN OPTIONS #
# most scanners only need 200 - 250 msecs to change bank -> try it out
# Mustek ScanExpress 6000 P
# name SE-6000P
# vendor Mustek
# option wait-lamp 15
# Mustek ScanExpress 600 SEP
# name SE-600SEP
# vendor Mustek
# option wait-lamp 15
# Mustek ScanMagic 4800 P
# name SM-4800P
# vendor Mustek
# option wait-lamp 15
# Mustek 600 III EP Plus
# name 600IIIEPP
# vendor Mustek
# option wait-lamp 15 # some models only need 5 secs...
# Mustek ScanMagic/Express 1200 ED Plus (this scanner isn't yet supported!!!)
# name SM-1200EDP
# name SE-1200EDP
# vendor Mustek
# this scanner has an optical resolution of 600 dpi
# option use600
# this scanner *must* use option niceload
# option niceload
# Fidelity Imaging Solutions Inc. Gallery 4800
# name Gallery-4800
# vendor Fidelity-Imaging-Solutions
# Viviscan Compact II
# name Compact-II
# vendor Viviscan
# Medion MD9848 (aka Aldi-Scanner)
name MD9848
vendor Medion
option wait-bank 250
# scan maximal 16 lines for one sane_read() call
option strip-height 16
# we just need 16 lines * 3 (rgb) colors * 300 dpi * 8.5 inch bytes
option buffer 122400
# Enable this option, if you want user authentification *and* if it's
# enabled at compile time
#option auth
# use this option to define the maximal black value for lineart scans
#option bw 127