/* sane - Scanner Access Now Easy.
|
|
|
|
Copyright (C) 2002 Sergey Vlasov <vsu@altlinux.ru>
|
|
Copyright (C) 2002 - 2007 Henning Geinitz <sane@geinitz.org>
|
|
|
|
This file is part of the SANE package.
|
|
|
|
This program is free software; you can redistribute it and/or
|
|
modify it under the terms of the GNU General Public License as
|
|
published by the Free Software Foundation; either version 2 of the
|
|
License, or (at your option) any later version.
|
|
|
|
This program is distributed in the hope that it will be useful, but
|
|
WITHOUT ANY WARRANTY; without even the implied warranty of
|
|
MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the GNU
|
|
General Public License for more details.
|
|
|
|
You should have received a copy of the GNU General Public License
|
|
along with this program; if not, write to the Free Software
|
|
Foundation, Inc., 59 Temple Place - Suite 330, Boston,
|
|
MA 02111-1307, USA.
|
|
|
|
As a special exception, the authors of SANE give permission for
|
|
additional uses of the libraries contained in this release of SANE.
|
|
|
|
The exception is that, if you link a SANE library with other files
|
|
to produce an executable, this does not by itself cause the
|
|
resulting executable to be covered by the GNU General Public
|
|
License. Your use of that executable is in no way restricted on
|
|
account of linking the SANE library code into it.
|
|
|
|
This exception does not, however, invalidate any other reasons why
|
|
the executable file might be covered by the GNU General Public
|
|
License.
|
|
|
|
If you submit changes to SANE to the maintainers to be included in
|
|
a subsequent release, you agree by submitting the changes that
|
|
those changes may be distributed with this exception intact.
|
|
|
|
If you write modifications of your own for SANE, it is your choice
|
|
whether to permit this exception to apply to your modifications.
|
|
If you do not wish that, delete this exception notice.
|
|
*/
|
|
|
|
#ifndef GT68XX_LOW_H
|
|
#define GT68XX_LOW_H
|
|
|
|
/** @file
|
|
* @brief Low-level scanner interface functions.
|
|
*/
|
|
|
|
#include "../include/sane/sane.h"
|
|
|
|
#include <stddef.h>
|
|
|
|
#ifdef USE_FORK
|
|
#include <sys/types.h>
|
|
#include "gt68xx_shm_channel.h"
|
|
#endif
|
|
|
|
#ifdef NDEBUG
|
|
#undef MAX_DEBUG
|
|
#endif
|
|
|
|
/* calculate the minimum/maximum values */
|
|
#define MIN(a, b) (((a) < (b)) ? (a) : (b))
|
|
#define MAX(a, b) (((a) > (b)) ? (a) : (b))
|
|
|
|
/* return the lower/upper 8 bits of a 16 bit word */
|
|
#define HIBYTE(w) ((SANE_Byte)(((SANE_Word)(w) >> 8) & 0xFF))
|
|
#define LOBYTE(w) ((SANE_Byte)(w))
|
|
|
|
|
|
/* return if an error occured while the function was called */
|
|
#ifdef MAX_DEBUG
|
|
# ifndef __FUNCTION__
|
|
# define __FUNCTION__ "somewhere"
|
|
# endif
|
|
|
|
# define RIE(function) \
|
|
do \
|
|
{ \
|
|
status = function; \
|
|
if (status != SANE_STATUS_GOOD) \
|
|
{ \
|
|
DBG (7, "%s: %s: %s\n", __FUNCTION__, STRINGIFY(function), \
|
|
sane_strstatus (status)); \
|
|
return status; \
|
|
} \
|
|
} \
|
|
while (SANE_FALSE)
|
|
|
|
#else
|
|
|
|
# define RIE(function) \
|
|
do { status = function; \
|
|
if (status != SANE_STATUS_GOOD) return status; \
|
|
} while (SANE_FALSE)
|
|
|
|
#endif
|
|
|
|
/* Flags */
|
|
#define GT68XX_FLAG_MIRROR_X (1 << 0) /* CIS unit mounted the other way round? */
|
|
#define GT68XX_FLAG_MOTOR_HOME (1 << 1) /* Use motor_home command (0x34) */
|
|
#define GT68XX_FLAG_OFFSET_INV (1 << 2) /* Offset control is inverted */
|
|
#define GT68XX_FLAG_UNTESTED (1 << 3) /* Print a warning for these scanners */
|
|
#define GT68XX_FLAG_SE_2400 (1 << 4) /* Special quirks for SE 2400USB */
|
|
#define GT68XX_FLAG_NO_STOP (1 << 5) /* Don't call stop_scan before the scan */
|
|
#define GT68XX_FLAG_CIS_LAMP (1 << 6) /* CIS sensor with lamp */
|
|
#define GT68XX_FLAG_NO_POWER_STATUS (1 << 7) /* get_power_status_doesn't work */
|
|
#define GT68XX_FLAG_NO_LINEMODE (1 << 8) /* Linemode does not work with this scanner */
|
|
#define GT68XX_FLAG_SCAN_FROM_HOME (1 << 9) /* Move home after calibration */
|
|
#define GT68XX_FLAG_USE_OPTICAL_X (1 << 10) /* Use optical xdpi for 50 dpi and below */
|
|
#define GT68XX_FLAG_ALWAYS_LINEMODE (1 << 11) /* Linemode must be used for any resolution */
|
|
#define GT68XX_FLAG_SHEET_FED (1 << 12) /* we have a sheet fed scanner */
|
|
#define GT68XX_FLAG_HAS_CALIBRATE (1 << 13) /* for sheet fed scanners that be calibrated with
|
|
an calibration sheet */
|
|
|
|
/* Forward typedefs */
|
|
typedef struct GT68xx_USB_Device_Entry GT68xx_USB_Device_Entry;
|
|
typedef struct GT68xx_Command_Set GT68xx_Command_Set;
|
|
typedef struct GT68xx_Model GT68xx_Model;
|
|
typedef struct GT68xx_Device GT68xx_Device;
|
|
typedef struct GT68xx_Scan_Request GT68xx_Scan_Request;
|
|
typedef struct GT68xx_Scan_Parameters GT68xx_Scan_Parameters;
|
|
typedef struct GT68xx_AFE_Parameters GT68xx_AFE_Parameters;
|
|
typedef struct GT68xx_Exposure_Parameters GT68xx_Exposure_Parameters;
|
|
|
|
typedef enum GT68xx_Color_Order
|
|
{
|
|
COLOR_ORDER_RGB,
|
|
COLOR_ORDER_BGR
|
|
}
|
|
GT68xx_Color_Order;
|
|
|
|
#define GT68XX_COLOR_RED SANE_I18N ("Red")
|
|
#define GT68XX_COLOR_GREEN SANE_I18N ("Green")
|
|
#define GT68XX_COLOR_BLUE SANE_I18N ("Blue")
|
|
|
|
/** Scan action code (purpose of the scan).
|
|
*
|
|
* The scan action code affects various scanning mode fields in the setup
|
|
* command.
|
|
*/
|
|
typedef enum GT68xx_Scan_Action
|
|
{
|
|
SA_CALIBRATE, /**< Calibration scan, no offsets, no LD
|
|
correction */
|
|
SA_CALIBRATE_ONE_LINE, /**< Same, but only one line for auto AFE */
|
|
SA_SCAN /**< Normal scan */
|
|
}
|
|
GT68xx_Scan_Action;
|
|
|
|
/** USB device list entry. */
|
|
struct GT68xx_USB_Device_Entry
|
|
{
|
|
SANE_Word vendor; /**< USB vendor identifier */
|
|
SANE_Word product; /**< USB product identifier */
|
|
GT68xx_Model *model; /**< Scanner model information */
|
|
};
|
|
|
|
#define MAX_SCANNERS 50
|
|
/* Looks like gcc doesn't like declarations without specificating the number
|
|
of array elements at least when --enable-warnings is active */
|
|
|
|
/** List of all supported devices.
|
|
*
|
|
* This is an array of GT68xx_USB_Device_Entry structures which describe
|
|
* USB devices supported by this backend. The array is terminated by an
|
|
* entry with model = NULL.
|
|
*
|
|
*/
|
|
static GT68xx_USB_Device_Entry gt68xx_usb_device_list[MAX_SCANNERS];
|
|
|
|
/** GT68xx analog front-end (AFE) parameters.
|
|
*/
|
|
struct GT68xx_AFE_Parameters
|
|
{
|
|
SANE_Byte r_offset; /**< Red channel offset */
|
|
SANE_Byte r_pga; /**< Red channel PGA gain */
|
|
SANE_Byte g_offset; /**< Green channel offset (also used for mono) */
|
|
SANE_Byte g_pga; /**< Green channel PGA gain (also used for mono) */
|
|
SANE_Byte b_offset; /**< Blue channel offset */
|
|
SANE_Byte b_pga; /**< Blue channel PGA gain */
|
|
};
|
|
|
|
/** GT68xx exposure time parameters.
|
|
*/
|
|
struct GT68xx_Exposure_Parameters
|
|
{
|
|
SANE_Int r_time; /**< Red exposure time */
|
|
SANE_Int g_time; /**< Red exposure time */
|
|
SANE_Int b_time; /**< Red exposure time */
|
|
};
|
|
|
|
|
|
/**
|
|
* Scanner command set description.
|
|
*
|
|
* This description contains parts which are common to all scanners with the
|
|
* same command set, but may have different optical resolution and other
|
|
* parameters.
|
|
*/
|
|
struct GT68xx_Command_Set
|
|
{
|
|
/** @name Identification */
|
|
/*@{ */
|
|
|
|
/** Name of this command set */
|
|
SANE_String_Const name;
|
|
|
|
/*@} */
|
|
|
|
/** @name USB request parameters
|
|
*
|
|
* These values are used in the USB control transfer parameters (wValue and
|
|
* wIndex fields, as in the USB specification).
|
|
*/
|
|
/*@{ */
|
|
|
|
SANE_Byte request_type; /**< Request type (should be 0x40, vendor spec) */
|
|
SANE_Byte request; /**< Vendor spec resquest (0x01 or 0x04) */
|
|
SANE_Word memory_read_value; /**< Memory read - wValue */
|
|
SANE_Word memory_write_value; /**< Memory write - wValue */
|
|
SANE_Word send_cmd_value; /**< Send normal command - wValue */
|
|
SANE_Word send_cmd_index; /**< Send normal command - wIndex */
|
|
SANE_Word recv_res_value; /**< Receive normal result - wValue */
|
|
SANE_Word recv_res_index; /**< Receive normal result - wIndex */
|
|
SANE_Word send_small_cmd_value; /**< Send small command - wValue */
|
|
SANE_Word send_small_cmd_index; /**< Send small command - wIndex */
|
|
SANE_Word recv_small_res_value; /**< Receive small result - wValue */
|
|
SANE_Word recv_small_res_index; /**< Receive small result - wIndex */
|
|
|
|
/*@} */
|
|
|
|
/** @name Activation/deactivation hooks
|
|
*
|
|
* These hooks can be used to perform additional actions when the device is
|
|
* activated and deactivated.
|
|
*/
|
|
/*@{ */
|
|
|
|
/** Activate the device.
|
|
*
|
|
* This function may allocate a command-set-specific data structure and place
|
|
* the pointer to it into the GT68xx_Device::command_set_private field.
|
|
*/
|
|
SANE_Status (*activate) (GT68xx_Device * dev);
|
|
|
|
/** Deactivate the device.
|
|
*
|
|
* If the activate function has allocated a command-set-specific data
|
|
* structure, this function must free all corresponding resources and set the
|
|
* GT68xx_Device::command_set_private pointer to #NULL.
|
|
*/
|
|
SANE_Status (*deactivate) (GT68xx_Device * dev);
|
|
|
|
/*@} */
|
|
|
|
/** @name Low-level command implementation functions
|
|
*
|
|
* These functions should implement the corresponding commands for the
|
|
* particular command set. If a function cannot be implemented because there
|
|
* is no corresponding command in the command set, the function pointer
|
|
* should be set to #NULL; the wrapper will return #SANE_STATUS_UNSUPPORTED
|
|
* in this case.
|
|
*/
|
|
/*@{ */
|
|
|
|
/** Check whether the firmware is already downloaded.
|
|
*
|
|
* @param dev Device object.
|
|
* @param loaded Returned firmware status:
|
|
* - #SANE_TRUE - the firmware is already loaded.
|
|
* - #SANE_FALSE - the firmware is not loaded.
|
|
*/
|
|
SANE_Status (*check_firmware) (GT68xx_Device * dev, SANE_Bool * loaded);
|
|
|
|
/** Download the firmware */
|
|
SANE_Status (*download_firmware) (GT68xx_Device * dev,
|
|
SANE_Byte * data, SANE_Word size);
|
|
|
|
/** Check whether the external power supply is connected.
|
|
*
|
|
* @param dev Device object.
|
|
* @param power_ok Returned power status:
|
|
* - #SANE_TRUE - the external power supply is connected, or the scanner does
|
|
* not need external power.
|
|
* - #SANE_FALSE - the external power supply is not connected, so the scanner
|
|
* will not work.
|
|
*/
|
|
SANE_Status (*get_power_status) (GT68xx_Device * dev,
|
|
SANE_Bool * power_ok);
|
|
|
|
/** Check whether a transparency adapter is attached to the scanner.
|
|
*
|
|
* @param dev Device object.
|
|
* @param ta_attached Returned transparency adapter status:
|
|
* - #SANE_TRUE - the transparency adapter is connected.
|
|
* - #SANE_FALSE - the transparency adapter is not connected.
|
|
*
|
|
* @return
|
|
* - #SANE_STATUS_GOOD - transparency adapter status was checked
|
|
* successfully; check @a *ta_attached for the result.
|
|
* - #SANE_STATUS_UNSUPPORTED - this scanner model does not support the
|
|
* transparency adapter.
|
|
* */
|
|
SANE_Status (*get_ta_status) (GT68xx_Device * dev,
|
|
SANE_Bool * ta_attached);
|
|
|
|
/** Turn the lamps in the scanner and/or the transparency adapter on or off.
|
|
*
|
|
* @param dev Device object.
|
|
* @param fb_lamp #SANE_TRUE turns on the flatbed lamp.
|
|
* @param ta_lamp #SANE_TRUE turns on the transparency adapter lamp.
|
|
*
|
|
* @return
|
|
* - #SANE_STATUS_GOOD - the command completed successfully.
|
|
* - #SANE_STATUS_UNSUPPORTED - unsupported request was made (like attempt to
|
|
* turn on the TA lamp on a scanner which does not support TA).
|
|
*/
|
|
SANE_Status (*lamp_control) (GT68xx_Device * dev, SANE_Bool fb_lamp,
|
|
SANE_Bool ta_lamp);
|
|
|
|
/** Check whether the scanner carriage is still moving.
|
|
*
|
|
* @param dev Device object.
|
|
* @param moving Returned state of the scanner:
|
|
* - #SANE_TRUE - the scanner carriage is still moving.
|
|
* - #SANE_FALSE - the scanner carriage has stopped.
|
|
*
|
|
* @return
|
|
* - #SANE_STATUS_GOOD - the command completed successfully, the status in @a
|
|
* *moving is valid.
|
|
*/
|
|
SANE_Status (*is_moving) (GT68xx_Device * dev, SANE_Bool * moving);
|
|
|
|
|
|
/** Move the scanner carriage by the specified number of steps.
|
|
*
|
|
* @param dev Device object.
|
|
* @param distance Number of steps to move (positive to move forward,
|
|
* negative to move backward). The measurement unit is model-dependent;
|
|
* number of steps per inch is found in the GT68xx_Model::base_ydpi field.
|
|
*
|
|
* @return
|
|
* - #SANE_STATUS_GOOD - the command completed successfully; the movement is
|
|
* started. Call gt68xx_device_is_moving() periodically to determine when
|
|
* the movement is complete.
|
|
*/
|
|
SANE_Status (*move_relative) (GT68xx_Device * dev, SANE_Int distance);
|
|
|
|
/** Move the scanner carriage to the home position.
|
|
*
|
|
* @param dev Device object.
|
|
*/
|
|
SANE_Status (*carriage_home) (GT68xx_Device * dev);
|
|
|
|
/** Eject the paper at the end of the scan.
|
|
*
|
|
* @param dev Device object.
|
|
*/
|
|
SANE_Status (*paperfeed) (GT68xx_Device * dev);
|
|
|
|
/** Start scanning the image.
|
|
*
|
|
* @param dev Device object.
|
|
*/
|
|
SANE_Status (*start_scan) (GT68xx_Device * dev);
|
|
|
|
/** Start reading the scanned image data from the scanner.
|
|
*
|
|
* @param dev Device object.
|
|
* */
|
|
SANE_Status (*read_scanned_data) (GT68xx_Device * dev, SANE_Bool * ready);
|
|
|
|
/** Stop scanning the image and reading the data. */
|
|
SANE_Status (*stop_scan) (GT68xx_Device * dev);
|
|
|
|
/** Set parameters for the next scan. */
|
|
SANE_Status (*setup_scan) (GT68xx_Device * dev,
|
|
GT68xx_Scan_Request * request,
|
|
GT68xx_Scan_Action action,
|
|
GT68xx_Scan_Parameters * params);
|
|
|
|
SANE_Status (*set_afe) (GT68xx_Device * dev,
|
|
GT68xx_AFE_Parameters * params);
|
|
|
|
SANE_Status (*set_exposure_time) (GT68xx_Device * dev,
|
|
GT68xx_Exposure_Parameters * params);
|
|
|
|
/** Get the vendor, product and some more ids from the scanner */
|
|
SANE_Status (*get_id) (GT68xx_Device * dev);
|
|
|
|
/** Move the paper by the amount of y offset needed to reach scan area
|
|
*
|
|
* @param dev Device object.
|
|
* @param request scan request used to compute move to reach scan area
|
|
*/
|
|
SANE_Status (*move_paper) (GT68xx_Device * dev,
|
|
GT68xx_Scan_Request * request);
|
|
|
|
/** Detect if a document is inserted in the feeder
|
|
*
|
|
* @param dev Device object.
|
|
* @param present
|
|
*/
|
|
SANE_Status (*document_present) (GT68xx_Device * dev,
|
|
SANE_Bool *present);
|
|
/*@} */
|
|
};
|
|
|
|
#define MAX_RESOLUTIONS 12
|
|
#define MAX_DPI 4
|
|
|
|
/** Model-specific scanner data.
|
|
*/
|
|
struct GT68xx_Model
|
|
{
|
|
/** @name Identification */
|
|
/*@{ */
|
|
|
|
/** A single lowercase word to be used in the configuration file. */
|
|
SANE_String_Const name;
|
|
|
|
/** Device vendor string. */
|
|
SANE_String_Const vendor;
|
|
|
|
/** Device model name. */
|
|
SANE_String_Const model;
|
|
|
|
/** Name of the firmware file. */
|
|
SANE_String_Const firmware_name;
|
|
|
|
/** Dynamic allocation flag.
|
|
*
|
|
* This flag must be set to SANE_TRUE if the structure is dynamically
|
|
* allocated; in this case the structure will be freed when the GT68xx_Device
|
|
* is freed.
|
|
*/
|
|
SANE_Bool allocated;
|
|
/*@} */
|
|
|
|
/** @name Scanner model parameters */
|
|
/*@{ */
|
|
|
|
GT68xx_Command_Set *command_set;
|
|
|
|
SANE_Int optical_xdpi; /* maximum resolution in x-direction */
|
|
SANE_Int optical_ydpi; /* maximum resolution in y-direction */
|
|
SANE_Int base_xdpi; /* x-resolution used to calculate geometry */
|
|
SANE_Int base_ydpi; /* y-resolution used to calculate geometry */
|
|
SANE_Int ydpi_no_backtrack; /* if ydpi is equal or higher, disable backtracking */
|
|
SANE_Bool constant_ydpi; /* Use base_ydpi for all resolutions */
|
|
|
|
SANE_Int xdpi_values[MAX_RESOLUTIONS]; /* possible x resolutions */
|
|
SANE_Int ydpi_values[MAX_RESOLUTIONS]; /* possible y resolutions */
|
|
SANE_Int bpp_gray_values[MAX_DPI]; /* possible depths in gray mode */
|
|
SANE_Int bpp_color_values[MAX_DPI]; /* possible depths in color mode */
|
|
|
|
SANE_Fixed x_offset; /* Start of scan area in mm */
|
|
SANE_Fixed y_offset; /* Start of scan area in mm */
|
|
SANE_Fixed x_size; /* Size of scan area in mm */
|
|
SANE_Fixed y_size; /* Size of scan area in mm */
|
|
|
|
SANE_Fixed y_offset_calib; /* Start of white strip in mm */
|
|
SANE_Fixed x_offset_mark; /* Start of black mark in mm */
|
|
|
|
SANE_Fixed x_offset_ta; /* Start of scan area in TA mode in mm */
|
|
SANE_Fixed y_offset_ta; /* Start of scan area in TA mode in mm */
|
|
SANE_Fixed x_size_ta; /* Size of scan area in TA mode in mm */
|
|
SANE_Fixed y_size_ta; /* Size of scan area in TA mode in mm */
|
|
|
|
SANE_Fixed y_offset_calib_ta; /* Start of white strip in TA mode in mm */
|
|
|
|
/* Line-distance correction (in pixel at optical_ydpi) for CCD scanners */
|
|
SANE_Int ld_shift_r; /* red */
|
|
SANE_Int ld_shift_g; /* green */
|
|
SANE_Int ld_shift_b; /* blue */
|
|
SANE_Int ld_shift_double; /* distance between two CCD lines of one color
|
|
(only applicable for CCD with 6 lines) */
|
|
|
|
GT68xx_Color_Order line_mode_color_order; /* Order of the CCD/CIS colors */
|
|
|
|
GT68xx_AFE_Parameters afe_params; /* Default offset/gain */
|
|
GT68xx_Exposure_Parameters exposure; /* Default exposure parameters */
|
|
SANE_Fixed default_gamma_value; /* Default gamma value */
|
|
|
|
SANE_Bool is_cis; /* Is this a CIS or CCD scanner? */
|
|
|
|
SANE_Word flags; /* Which hacks are needed for this scanner? */
|
|
/*@} */
|
|
};
|
|
|
|
/** GT68xx device instance.
|
|
*
|
|
*/
|
|
struct GT68xx_Device
|
|
{
|
|
/** Device file descriptor. */
|
|
int fd;
|
|
|
|
/** Device activation flag. */
|
|
SANE_Bool active;
|
|
|
|
/** Scanner model data. */
|
|
GT68xx_Model *model;
|
|
|
|
/** Pointer to command-set-specific data. */
|
|
void *command_set_private;
|
|
|
|
GT68xx_AFE_Parameters *afe;
|
|
GT68xx_Exposure_Parameters *exposure;
|
|
SANE_Fixed gamma_value;
|
|
|
|
SANE_Bool read_active;
|
|
SANE_Bool final_scan;
|
|
SANE_Byte *read_buffer;
|
|
size_t requested_buffer_size;
|
|
size_t read_buffer_size;
|
|
size_t read_pos;
|
|
size_t read_bytes_in_buffer;
|
|
size_t read_bytes_left;
|
|
SANE_Byte gray_mode_color;
|
|
SANE_Bool manual_selection;
|
|
#ifdef USE_FORK
|
|
Shm_Channel *shm_channel;
|
|
pid_t reader_pid;
|
|
#endif /* USE_FORK */
|
|
|
|
/** Pointer to next device */
|
|
struct GT68xx_Device *next;
|
|
|
|
/** Device file name */
|
|
SANE_String file_name;
|
|
};
|
|
|
|
/** Parameters for the high-level scan request.
|
|
*
|
|
* These parameters describe the scan request sent by the SANE frontend.
|
|
*/
|
|
struct GT68xx_Scan_Request
|
|
{
|
|
SANE_Fixed x0; /**< Left boundary */
|
|
SANE_Fixed y0; /**< Top boundary */
|
|
SANE_Fixed xs; /**< Width */
|
|
SANE_Fixed ys; /**< Height */
|
|
SANE_Int xdpi; /**< Horizontal resolution */
|
|
SANE_Int ydpi; /**< Vertical resolution */
|
|
SANE_Int depth; /**< Number of bits per channel */
|
|
SANE_Bool color; /**< Color mode flag */
|
|
SANE_Bool mbs; /**< Move before scan */
|
|
SANE_Bool mds; /**< Move during scan */
|
|
SANE_Bool mas; /**< Move after scan */
|
|
SANE_Bool lamp; /**< Lamp on/off */
|
|
SANE_Bool calculate; /**< Don't scan, only calculate parameters */
|
|
SANE_Bool use_ta; /**< Use the tansparency adapter */
|
|
SANE_Bool backtrack; /**< Enable backtracking */
|
|
SANE_Bool backtrack_lines; /**< How many lines to backtrack */
|
|
};
|
|
|
|
/** Scan parameters for gt68xx_device_setup_scan().
|
|
*
|
|
* These parameters describe a low-level scan request; many such requests are
|
|
* executed during calibration, and they need to have parameters separate from
|
|
* the main request (GT68xx_Scan_Request).
|
|
*/
|
|
struct GT68xx_Scan_Parameters
|
|
{
|
|
SANE_Int xdpi; /**< Horizontal resolution */
|
|
SANE_Int ydpi; /**< Vertical resolution */
|
|
SANE_Int depth; /**< Number of bits per channel */
|
|
SANE_Bool color; /**< Color mode flag */
|
|
|
|
SANE_Int pixel_xs; /**< Logical width in pixels */
|
|
SANE_Int pixel_ys; /**< Logical height in pixels */
|
|
SANE_Int scan_xs; /**< Physical width in pixels */
|
|
SANE_Int scan_ys; /**< Physical height in pixels */
|
|
SANE_Int scan_bpl; /**< Number of bytes per scan line */
|
|
SANE_Bool line_mode; /**< Use line mode instead of pixel mode */
|
|
SANE_Int overscan_lines; /**< Number of extra scan lines */
|
|
SANE_Int ld_shift_r;
|
|
SANE_Int ld_shift_g;
|
|
SANE_Int ld_shift_b;
|
|
SANE_Int ld_shift_double;
|
|
SANE_Int double_column;
|
|
SANE_Int pixel_x0; /**< x start postion */
|
|
};
|
|
|
|
|
|
#define GT68XX_PACKET_SIZE 64
|
|
|
|
typedef SANE_Byte GT68xx_Packet[GT68XX_PACKET_SIZE];
|
|
|
|
/** Create a new GT68xx_Device object.
|
|
*
|
|
* The newly created device object is in the closed state.
|
|
*
|
|
* @param dev_return Returned pointer to the created device object.
|
|
*
|
|
* @return
|
|
* - #SANE_STATUS_GOOD - the device object was created.
|
|
* - #SANE_STATUS_NO_MEM - not enough system resources to create the object.
|
|
*/
|
|
static SANE_Status gt68xx_device_new (GT68xx_Device ** dev_return);
|
|
|
|
/** Destroy the device object and release all associated resources.
|
|
*
|
|
* If the device was active, it will be deactivated; if the device was open, it
|
|
* will be closed.
|
|
*
|
|
* @param dev Device object.
|
|
*
|
|
* @return
|
|
* - #SANE_STATUS_GOOD - success.
|
|
*/
|
|
static SANE_Status gt68xx_device_free (GT68xx_Device * dev);
|
|
|
|
/** Open the scanner device.
|
|
*
|
|
* This function opens the device special file @a dev_name and tries to detect
|
|
* the device model by its USB ID.
|
|
*
|
|
* If the device is detected successfully (its USB ID is found in the supported
|
|
* device list), this function sets the appropriate model parameters.
|
|
*
|
|
* If the USB ID is not recognized, the device remains unconfigured; an attempt
|
|
* to activate it will fail unless gt68xx_device_set_model() is used to force
|
|
* the parameter set. Note that the open is considered to be successful in
|
|
* this case.
|
|
*
|
|
* @param dev Device object.
|
|
* @param dev_name Scanner device name.
|
|
*
|
|
* @return
|
|
* - #SANE_STATUS_GOOD - the device was opened successfully (it still may be
|
|
* unconfigured).
|
|
*/
|
|
static SANE_Status
|
|
gt68xx_device_open (GT68xx_Device * dev, const char *dev_name);
|
|
|
|
/** Close the scanner device.
|
|
*
|
|
* @param dev Device object.
|
|
*/
|
|
static SANE_Status gt68xx_device_close (GT68xx_Device * dev);
|
|
|
|
/** Check if the device is configured.
|
|
*
|
|
* A device is considered configured when it has a model parameters structure
|
|
* (GT68xx_Model) and a command set (GT68xx_Command_Set). Normally these
|
|
* parameters are assigned automatically by gt68xx_device_open(), if the device
|
|
* is known. If the USB ID of the device is not found in the list, or the OS
|
|
* does not support identification of USB devices, the device will be
|
|
* unconfigured after opening.
|
|
*
|
|
* @param dev Device object.
|
|
*
|
|
* @return
|
|
* - #SANE_TRUE - device is configured and can be activated.
|
|
* - #SANE_FALSE - device is not configured; attempt to activate it will fail.
|
|
*/
|
|
static SANE_Bool gt68xx_device_is_configured (GT68xx_Device * dev);
|
|
|
|
/** Change the device model structure.
|
|
*
|
|
* This function can be used to change all model-dependent parameters at once
|
|
* by supplying a whole model data structure. The model may be changed only
|
|
* when the device is not active.
|
|
*
|
|
* If the device already had a model structure which was dynamically allocated,
|
|
* the old structure is freed.
|
|
*
|
|
* If the new model structure @a model is dynamically allocated, the device @a
|
|
* dev takes ownership of it: @a model will be freed when @a dev is destroyed
|
|
* or gt68xx_device_set_model() is called again.
|
|
*
|
|
* @param dev Device object.
|
|
* @param model Device model data.
|
|
*
|
|
* @return
|
|
* - #SANE_STATUS_GOOD - model successfully changed.
|
|
* - #SANE_STATUS_INVAL - invalid request (attempt to change model when the
|
|
* device is already active, or not yet opened).
|
|
*/
|
|
static SANE_Status
|
|
gt68xx_device_set_model (GT68xx_Device * dev, GT68xx_Model * model);
|
|
|
|
/** Get model by name.
|
|
*
|
|
* This function can be used to find a model by its name.
|
|
*
|
|
* @param name Device model name.
|
|
* @param model Device model data.
|
|
*
|
|
* @return
|
|
* - #SANE_TRUE - model successfully found.
|
|
* - #SANE_FALSE - model not found.
|
|
*/
|
|
static SANE_Bool
|
|
gt68xx_device_get_model (SANE_String name, GT68xx_Model ** model);
|
|
|
|
#if 0
|
|
/** Create a new private copy of the model data for this device.
|
|
*
|
|
* Normally the model data structures can be shared between several devices.
|
|
* If the program needs to modify some model parameters for a device, it must
|
|
* call this function to make a private copy of parameters. This private copy
|
|
* will be automatically freed when the device is destroyed.
|
|
*
|
|
* @param dev Device object.
|
|
*
|
|
* @return
|
|
* - #SANE_STATUS_GOOD - a private copy was made successfully.
|
|
* - #SANE_STATUS_INVAL - invalid request (the device was already active, or
|
|
* not yet opened).
|
|
* - #SANE_STATUS_NO_MEM - not enough memory for copy of the model parameters.
|
|
*/
|
|
static SANE_Status gt68xx_device_unshare_model (GT68xx_Device * dev);
|
|
#endif
|
|
|
|
/** Activate the device.
|
|
*
|
|
* The device must be activated before performing any I/O operations with it.
|
|
* All device model parameters must be configured before activation; it is
|
|
* impossible to change them after the device is active.
|
|
*
|
|
* This function might need to acquire resources (it calls
|
|
* GT68xx_Command_Set::activate). These resources will be released when
|
|
* gt68xx_device_deactivate() is called.
|
|
*
|
|
* @param dev Device object.
|
|
*
|
|
* @return
|
|
* - #SANE_STATUS_GOOD - device activated successfully.
|
|
* - #SANE_STATUS_INVAL - invalid request (attempt to activate a closed or
|
|
* unconfigured device).
|
|
*/
|
|
static SANE_Status gt68xx_device_activate (GT68xx_Device * dev);
|
|
|
|
/** Deactivate the device.
|
|
*
|
|
* This function reverses the action of gt68xx_device_activate().
|
|
*
|
|
* @param dev Device object.
|
|
*
|
|
* @return
|
|
* - #SANE_STATUS_GOOD - device deactivated successfully.
|
|
* - #SANE_STATUS_INVAL - invalid request (the device was not activated).
|
|
*/
|
|
static SANE_Status gt68xx_device_deactivate (GT68xx_Device * dev);
|
|
|
|
/** Write a data block to the GT68xx memory.
|
|
*
|
|
* @param dev Device object.
|
|
* @param addr Start address in the GT68xx memory.
|
|
* @param size Size of the data block in bytes.
|
|
* @param data Data block to write.
|
|
*
|
|
* @return
|
|
* - #SANE_STATUS_GOOD - success.
|
|
* - #SANE_STATUS_IO_ERROR - a communication error occured.
|
|
*
|
|
* @warning
|
|
* @a size must be a multiple of 64 (at least with GT6816), otherwise the
|
|
* scanner (and possibly the entire USB bus) will lock up.
|
|
*/
|
|
static SANE_Status
|
|
gt68xx_device_memory_write (GT68xx_Device * dev, SANE_Word addr,
|
|
SANE_Word size, SANE_Byte * data);
|
|
|
|
/** Read a data block from the GT68xx memory.
|
|
*
|
|
* @param dev Device object.
|
|
* @param addr Start address in the GT68xx memory.
|
|
* @param size Size of the data block in bytes.
|
|
* @param data Buffer for the read data.
|
|
*
|
|
* @return
|
|
* - #SANE_STATUS_GOOD - success.
|
|
* - #SANE_STATUS_IO_ERROR - a communication error occured.
|
|
*
|
|
* @warning
|
|
* @a size must be a multiple of 64 (at least with GT6816), otherwise the
|
|
* scanner (and possibly the entire USB bus) will lock up.
|
|
*/
|
|
static SANE_Status
|
|
gt68xx_device_memory_read (GT68xx_Device * dev, SANE_Word addr,
|
|
SANE_Word size, SANE_Byte * data);
|
|
|
|
/** Execute a control command.
|
|
*
|
|
* @param dev Device object.
|
|
* @param cmd Command packet.
|
|
* @param res Result packet (may point to the same buffer as @a cmd).
|
|
*
|
|
* @return
|
|
* - #SANE_STATUS_GOOD - success.
|
|
* - #SANE_STATUS_IO_ERROR - a communication error occured.
|
|
*/
|
|
static SANE_Status
|
|
gt68xx_device_req (GT68xx_Device * dev, GT68xx_Packet cmd, GT68xx_Packet res);
|
|
|
|
/** Execute a "small" control command.
|
|
*
|
|
* @param dev Device object.
|
|
* @param cmd Command packet; only first 8 bytes are used.
|
|
* @param res Result packet (may point to the same buffer as @a cmd).
|
|
*
|
|
* @return
|
|
* - #SANE_STATUS_GOOD - success.
|
|
* - #SANE_STATUS_IO_ERROR - a communication error occured.
|
|
*/
|
|
static SANE_Status
|
|
gt68xx_device_small_req (GT68xx_Device * dev, GT68xx_Packet cmd,
|
|
GT68xx_Packet res);
|
|
|
|
#if 0
|
|
/** Check whether the firmware is downloaded into the scanner.
|
|
*
|
|
* @param dev Device object.
|
|
* @param loaded Returned firmware status:
|
|
* - #SANE_TRUE - the firmware is already loaded.
|
|
* - #SANE_FALSE - the firmware is not loaded.
|
|
*
|
|
* @return
|
|
* - #SANE_STATUS_GOOD - success.
|
|
* - #SANE_STATUS_IO_ERROR - a communication error occured.
|
|
*/
|
|
static SANE_Status
|
|
gt68xx_device_check_firmware (GT68xx_Device * dev, SANE_Bool * loaded);
|
|
#endif
|
|
|
|
static SANE_Status
|
|
gt68xx_device_download_firmware (GT68xx_Device * dev,
|
|
SANE_Byte * data, SANE_Word size);
|
|
|
|
/** Check whether the external power supply is connected.
|
|
*
|
|
* @param dev Device object.
|
|
* @param power_ok Returned power status:
|
|
* - #SANE_TRUE - the external power supply is connected, or the scanner does
|
|
* not need external power.
|
|
* - #SANE_FALSE - the external power supply is not connected, so the scanner
|
|
* will not work.
|
|
*
|
|
* @return
|
|
* - #SANE_STATUS_GOOD - success.
|
|
* - #SANE_STATUS_IO_ERROR - a communication error occured.
|
|
*/
|
|
static SANE_Status
|
|
gt68xx_device_get_power_status (GT68xx_Device * dev, SANE_Bool * power_ok);
|
|
|
|
/** Check whether the transparency adapter is connected.
|
|
*
|
|
* @param dev Device object.
|
|
* @param ta_attached Returned TA status:
|
|
* - #SANE_TRUE - the TA is connected.
|
|
* - #SANE_FALSE - the TA is not connected.
|
|
*
|
|
* @return
|
|
* - #SANE_STATUS_GOOD - success.
|
|
* - #SANE_STATUS_UNSUPPORTED - the scanner does not support TA connection.
|
|
* - #SANE_STATUS_IO_ERROR - a communication error occured.
|
|
*/
|
|
static SANE_Status
|
|
gt68xx_device_get_ta_status (GT68xx_Device * dev, SANE_Bool * ta_attached);
|
|
|
|
/** Turn the lamps in the scanner and/or the transparency adapter on or off.
|
|
*
|
|
* @param dev Device object.
|
|
* @param fb_lamp #SANE_TRUE turns on the flatbed lamp.
|
|
* @param ta_lamp #SANE_TRUE turns on the transparency adapter lamp.
|
|
*
|
|
* @return
|
|
* - #SANE_STATUS_GOOD - success.
|
|
* - #SANE_STATUS_IO_ERROR - a communication error occured.
|
|
* - #SANE_STATUS_UNSUPPORTED - unsupported request was made (like attempt to
|
|
* turn on the TA lamp on a scanner which does not support TA).
|
|
*/
|
|
static SANE_Status
|
|
gt68xx_device_lamp_control (GT68xx_Device * dev, SANE_Bool fb_lamp,
|
|
SANE_Bool ta_lamp);
|
|
|
|
/** Check whether the scanner carriage is still moving.
|
|
*
|
|
* @param dev Device object.
|
|
* @param moving Returned state of the scanner:
|
|
* - #SANE_TRUE - the scanner carriage is still moving.
|
|
* - #SANE_FALSE - the scanner carriage has stopped.
|
|
*
|
|
* @return
|
|
* - #SANE_STATUS_GOOD - success; the status in @a *moving is valid.
|
|
* - #SANE_STATUS_IO_ERROR - a communication error occured.
|
|
*/
|
|
static SANE_Status
|
|
gt68xx_device_is_moving (GT68xx_Device * dev, SANE_Bool * moving);
|
|
|
|
#if 0
|
|
/** Move the scanner carriage by the specified number of steps.
|
|
*
|
|
* @param dev Device object.
|
|
* @param distance Number of steps to move (positive to move forward, negative
|
|
* to move backward). The measurement unit is model-dependent; number of steps
|
|
* per inch is found in the GT68xx_Model::base_ydpi field.
|
|
*
|
|
* @return
|
|
* - #SANE_STATUS_GOOD - success; the movement is started. Call
|
|
* gt68xx_device_is_moving() periodically to determine when the movement is
|
|
* complete.
|
|
* - #SANE_STATUS_IO_ERROR - a communication error occured.
|
|
*/
|
|
static SANE_Status
|
|
gt68xx_device_move_relative (GT68xx_Device * dev, SANE_Int distance);
|
|
#endif
|
|
|
|
/** Move the scanner carriage to the home position.
|
|
*
|
|
* This function starts moving the scanner carriage to the home position, but
|
|
* deos not wait for finishing the movement. To determine when the carriage
|
|
* returned to the home position, the program should periodically call
|
|
* gt68xx_device_is_moving().
|
|
*
|
|
* @param dev Device object.
|
|
*
|
|
* @return
|
|
* - #SANE_STATUS_GOOD - success; the movement is started.
|
|
* - #SANE_STATUS_IO_ERROR - a communication error occured.
|
|
*/
|
|
static SANE_Status gt68xx_device_carriage_home (GT68xx_Device * dev);
|
|
|
|
/** Eject the paper after the end of scanning.
|
|
*
|
|
*
|
|
* @param dev Device object.
|
|
*
|
|
* @return
|
|
* - #SANE_STATUS_GOOD - success; the movement is started.
|
|
* - #SANE_STATUS_IO_ERROR - a communication error occured.
|
|
*/
|
|
static SANE_Status gt68xx_device_paperfeed (GT68xx_Device * dev);
|
|
|
|
/** Start scanning the image.
|
|
*
|
|
* This function initiates scanning with parameters set by
|
|
* gt68xx_device_setup_scan() (which should be called before). In particular,
|
|
* it starts the carriage movement to the start of the scanning window.
|
|
*
|
|
* After calling this function, gt68xx_device_read_scanned_data() should be
|
|
* called repeatedly until the scanner signals that it is ready to deliver the
|
|
* data.
|
|
*
|
|
* @param dev Device object.
|
|
*
|
|
* @return
|
|
* - #SANE_STATUS_GOOD - success.
|
|
* - #SANE_STATUS_IO_ERROR - a communication error occured.
|
|
*/
|
|
static SANE_Status gt68xx_device_start_scan (GT68xx_Device * dev);
|
|
|
|
/** Start reading the scanned image data.
|
|
*
|
|
* This function should be used only after gt68xx_device_start_scan(). It
|
|
* should be called repeatedly until @a *ready flag becomes true, at which
|
|
* point reading the image data should be started using
|
|
* gt68xx_device_read_prepare().
|
|
*
|
|
* @param dev Device object.
|
|
* @param ready Returned status of the scanner:
|
|
* - #SANE_TRUE - the scanner is ready to send data.
|
|
* - #SANE_FALSE - the scanner is not ready (e.g., the carriage has not reached
|
|
* the start of the scanning window).
|
|
*
|
|
* @return
|
|
* - #SANE_STATUS_GOOD - success; the value in @a *ready is valid.
|
|
* - #SANE_STATUS_IO_ERROR - a communication error occured.
|
|
*/
|
|
static SANE_Status
|
|
gt68xx_device_read_scanned_data (GT68xx_Device * dev, SANE_Bool * ready);
|
|
|
|
/** Stop scanning the image.
|
|
*
|
|
* This function should be used after reading all image data from the scanner,
|
|
* or in the middle of scan to abort the scanning process.
|
|
*
|
|
* @param dev Device object.
|
|
*
|
|
* @return
|
|
* - #SANE_STATUS_GOOD - success.
|
|
* - #SANE_STATUS_IO_ERROR - a communication error occured.
|
|
*/
|
|
static SANE_Status gt68xx_device_stop_scan (GT68xx_Device * dev);
|
|
|
|
/** Set parameters for the next scan.
|
|
*
|
|
* This function calculates the hardware-dependent scanning parameters and,
|
|
* unless @a calculate_only is set, sends the command to prepare for scanning
|
|
* with the specified window and parameters.
|
|
*
|
|
* @param dev Device object.
|
|
* @param request High-level scanning request.
|
|
* @param action Action code describing the phase of calibration or scanning
|
|
* process.
|
|
* @param params Returned structure with hardware-dependent scanning
|
|
* parameters.
|
|
*
|
|
* @return
|
|
* - #SANE_STATUS_GOOD - success.
|
|
* - #SANE_STATUS_UNSUPPORTED - the requested scanning parameters in @a request
|
|
* are not supported by hardware.
|
|
* - #SANE_STATUS_INVAL - some of the parameters in @a request, or the @a
|
|
* action code, are completely invalid.
|
|
* - #SANE_STATUS_IO_ERROR - a communication error occured.
|
|
*/
|
|
static SANE_Status
|
|
gt68xx_device_setup_scan (GT68xx_Device * dev,
|
|
GT68xx_Scan_Request * request,
|
|
GT68xx_Scan_Action action,
|
|
GT68xx_Scan_Parameters * params);
|
|
|
|
/** Configure the analog front-end (AFE) of the GT68xx.
|
|
*
|
|
* @param dev Device object.
|
|
* @param params AFE parameters.
|
|
*
|
|
* @return
|
|
* - #SANE_STATUS_GOOD - success.
|
|
* - #SANE_STATUS_IO_ERROR - a communication error occured.
|
|
*/
|
|
static SANE_Status
|
|
gt68xx_device_set_afe (GT68xx_Device * dev, GT68xx_AFE_Parameters * params);
|
|
|
|
static SANE_Status
|
|
gt68xx_device_set_exposure_time (GT68xx_Device * dev,
|
|
GT68xx_Exposure_Parameters * params);
|
|
|
|
/** Read raw data from the bulk-in scanner pipe.
|
|
*
|
|
* @param dev Device object.
|
|
* @param buffer Buffer for the read data.
|
|
* @param size Pointer to the variable which must be set to the requested data
|
|
* size before call. After completion this variable will hold the number of
|
|
* bytes actually read.
|
|
*
|
|
* @return
|
|
* - #SANE_STATUS_GOOD - success.
|
|
* - #SANE_STATUS_IO_ERROR - a communication error occured.
|
|
*/
|
|
static SANE_Status
|
|
gt68xx_device_read_raw (GT68xx_Device * dev, SANE_Byte * buffer,
|
|
size_t * size);
|
|
|
|
static SANE_Status
|
|
gt68xx_device_set_read_buffer_size (GT68xx_Device * dev, size_t buffer_size);
|
|
|
|
static SANE_Status
|
|
gt68xx_device_read_prepare (GT68xx_Device * dev, size_t expected_count,
|
|
SANE_Bool final_scan);
|
|
|
|
static SANE_Status
|
|
gt68xx_device_read (GT68xx_Device * dev, SANE_Byte * buffer, size_t * size);
|
|
|
|
static SANE_Status gt68xx_device_read_finish (GT68xx_Device * dev);
|
|
|
|
/** Make sure that the result of a command is ok.
|
|
*
|
|
* @param res Result packet from the last command
|
|
* @param command Command
|
|
*
|
|
* @return
|
|
* - #SANE_STATUS_GOOD - success.
|
|
* - #SANE_STATUS_IO_ERROR - the command wasn't successful
|
|
*/
|
|
static SANE_Status
|
|
gt68xx_device_check_result (GT68xx_Packet res, SANE_Byte command);
|
|
|
|
|
|
static SANE_Status
|
|
gt68xx_device_get_id (GT68xx_Device * dev);
|
|
|
|
/** Read the device descriptor of the scanner.
|
|
*
|
|
* This function should be called before closing the device to make sure
|
|
* that the device descriptor is propperly stored in the scanner's memory.
|
|
* If that's not done, the next try to get the config descriptor will
|
|
* result in a corrupted descriptor.
|
|
*
|
|
* @param dev device
|
|
*/
|
|
static void
|
|
gt68xx_device_fix_descriptor (GT68xx_Device * dev);
|
|
|
|
#endif /* not GT68XX_LOW_H */
|
|
|
|
/* vim: set sw=2 cino=>2se-1sn-1s{s^-1st0(0u0 smarttab expandtab: */
|