| .TH sane\-u12 5 "14 Jul 2008" "@PACKAGEVERSION@" "SANE Scanner Access Now Easy"
 | |
| .IX sane\-u12
 | |
| .SH NAME
 | |
| sane\-u12 \- SANE backend for Plustek USB flatbed scanners,
 | |
| based on older parport designs
 | |
| .SH DESCRIPTION
 | |
| The
 | |
| .B sane\-u12
 | |
| library implements a SANE (Scanner Access Now Easy) backend that
 | |
| provides access to USB flatbed scanners based on Plusteks' ASIC
 | |
| 98003 (parallel-port ASIC) and a GeneSys Logics' USB-parport
 | |
| bridge chip.
 | |
| 
 | |
| .SH "SUPPORTED DEVICES"
 | |
| The backend is able to support some early Plustek USB scanner based
 | |
| their old parport design around the ASIC 98003 and other rebadged
 | |
| Plustek devices. The following tables will give you a short overview.
 | |
| 
 | |
| If your Plustek scanner has another Product ID, then the device is
 | |
| .B NOT
 | |
| supported by this backend.
 | |
| .br
 | |
| 
 | |
| Vendor Plustek \- ID: 0x07B3
 | |
| .br
 | |
| .ft CR
 | |
| .nf
 | |
| ----------------------------------------------------------
 | |
| Model:                   Vendor-ID:       Product-ID:
 | |
| ----------------------------------------------------------
 | |
| OpticPro U12             0x07B3           0x0001
 | |
| OpticPro U1212           0x07B3           0x0001
 | |
| OpticPro UT12            0x07B3           0x0001
 | |
| .fi
 | |
| .ft R
 | |
| .PP
 | |
| 
 | |
| Vendor KYE/Genius
 | |
| .br
 | |
| .ft CR
 | |
| .nf
 | |
| --------------------------------------------------------
 | |
| USB Model:               Vendor-ID:       Product-ID:
 | |
| --------------------------------------------------------
 | |
| ColorPage Vivid III USB  0x07B3           0x0001
 | |
| ColorPage HR6 V1         0x0458           0x2004
 | |
| .fi
 | |
| .ft R
 | |
| .PP
 | |
| 
 | |
| .SH "CONFIGURATION"
 | |
| To use your scanner with this backend, you need at least two
 | |
| entries in the configuration file
 | |
| .I @CONFIGDIR@/u12.conf
 | |
| .RS
 | |
| .I [usb] vendor-id product-id
 | |
| .br
 | |
| .I device /dev/usbscanner
 | |
| .RE
 | |
| .PP
 | |
| .I [usb]
 | |
| tells the backend, that the following devicename (here
 | |
| .IR /dev/usbscanner )
 | |
| has to be interpreted as USB scanner device. If vendor- and
 | |
| product-id has not been specified, the backend tries to
 | |
| detect this by its own. If device is set to
 | |
| .I auto
 | |
| then the next matching device is used.
 | |
| .PP
 | |
| .B
 | |
| The Options:
 | |
| .PP
 | |
| option warmup t
 | |
| .RS
 | |
| .I t
 | |
| specifies the warmup period in seconds
 | |
| .RE
 | |
| .PP
 | |
| option lampOff t
 | |
| .RS
 | |
| .I t
 | |
| is the time in seconds for switching off the lamps in
 | |
| standby mode
 | |
| .RE
 | |
| .PP
 | |
| option lOffonEnd b
 | |
| .RS
 | |
| .I b
 | |
| specifies the behaviour when closing the backend, 1 --> switch
 | |
| lamps off, 0 --> do not change lamp status
 | |
| .RE
 | |
| 
 | |
| .PP
 | |
| See the u12.conf file for examples.
 | |
| .PP
 | |
| .B Note:
 | |
| .br
 | |
| You have to make sure, that the USB subsystem is loaded
 | |
| correctly and you have access to the device-node. For
 | |
| more details see
 | |
| .B sane\-usb (5)
 | |
| manpage. You might use
 | |
| .B sane\-find\-scanner
 | |
| to check that you have access to your device.
 | |
| .PP
 | |
| .B Note:
 | |
| .br
 | |
| If there's no configuration file, the backend defaults to
 | |
| .B device auto
 | |
| 
 | |
| .SH FILES
 | |
| .TP
 | |
| .I @CONFIGDIR@/u12.conf
 | |
| The backend configuration file
 | |
| .TP
 | |
| .I @LIBDIR@/libsane\-u12.a
 | |
| The static library implementing this backend.
 | |
| .TP
 | |
| .I @LIBDIR@/libsane\-u12.so
 | |
| The shared library implementing this backend (present on systems that
 | |
| support dynamic loading).
 | |
| 
 | |
| .SH ENVIRONMENT
 | |
| .TP
 | |
| .B SANE_CONFIG_DIR
 | |
| This environment variable specifies the list of directories that may
 | |
| contain the configuration file.  Under UNIX, the directories are
 | |
| separated by a colon (`:'), under OS/2, they are separated by a
 | |
| semi-colon (`;').  If this variable is not set, the configuration file
 | |
| is searched in two default directories: first, the current working
 | |
| directory (".") and then in @CONFIGDIR@.  If the value of the
 | |
| environment variable ends with the directory separator character, then
 | |
| the default directories are searched after the explicitly specified
 | |
| directories.  For example, setting
 | |
| .B SANE_CONFIG_DIR
 | |
| to "/tmp/config:" would result in directories "tmp/config", ".", and
 | |
| "@CONFIGDIR@" being searched (in this order).
 | |
| .TP
 | |
| .B SANE_DEBUG_U12
 | |
| If the library was compiled with debug support enabled, this
 | |
| environment variable controls the debug level for this backend.  Higher
 | |
| debug levels increase the verbosity of the output.
 | |
| 
 | |
| Example:
 | |
| export SANE_DEBUG_U12=10
 | |
| 
 | |
| .SH "SEE ALSO"
 | |
| .BR sane (7),
 | |
| .BR sane\-usb (5),
 | |
| .BR sane\-plustek (5),
 | |
| .br
 | |
| .I @DOCDIR@/u12/U12.changes
 | |
| .br
 | |
| .I http://www.gjaeger.de/scanner/u12/
 | |
| 
 | |
| .SH "CONTACT AND BUG-REPORTS"
 | |
| Please send any information and bug-reports to:
 | |
| .br
 | |
| .B SANE Mailing List
 | |
| .PP
 | |
| Additional info and hints can be obtained from our
 | |
| .br
 | |
| Mailing-List archive at:
 | |
| .br
 | |
| .B http://www.sane\-project.org/mailing\-lists.html
 | |
| .PP
 | |
| or directly from the projects' homepage at:
 | |
| .br
 | |
| .B http://www.gjaeger.de/scanner/u12/
 | |
| .PP
 | |
| To obtain debug messages from the backend, please set the
 | |
| environment-variable
 | |
| .I SANE_DEBUG_U12
 | |
| before calling your favorite scan-frontend (i.e. xscanimage).
 | |
| .br
 | |
| .B i.e.: export SANE_DEBUG_U12=20 ; xscanimage
 | |
| .PP
 | |
| The value controls the verbosity of the backend.
 | |
| 
 | |
| .SH "KNOWN BUGS & RESTRICTIONS"
 | |
| * The driver is in alpha state, so please don't expect too much!!!
 | |
| .PP
 | |
| * When using libusb, it might be, that the backend hangs. 
 | |
| In that case, reconnect the scanner.
 |