kopia lustrzana https://gitlab.com/sane-project/backends
51 wiersze
2.4 KiB
Plaintext
51 wiersze
2.4 KiB
Plaintext
Plustek-USB-TODO.txt (2004-07-26) Gerhard J<>er <gerhard@gjaeger.de>
|
||
====================================================================
|
||
|
||
TODO (in general):
|
||
- more documentation/comments for the different functions
|
||
|
||
|
||
KNOWN BUGS/Limitations:
|
||
|
||
Model Description Workaround
|
||
------------------------------------------------------------------------------
|
||
|
||
HP 2100c Straight Line Bug none
|
||
All with TPA Negative Scanning quality bad none
|
||
CIS devices Skip calibration does not work none
|
||
|
||
********************************* DONE ***************************************
|
||
|
||
all add plustek.conf presettings to done
|
||
interface for frontends
|
||
|
||
all Auto-warmup done
|
||
all Sensor movement speedup ffw/rev done
|
||
|
||
Canon fine calibration does not work fixed
|
||
Canon 650 color modes >=600 dpi too dark fixed
|
||
Canon 660 add support done
|
||
Canon 1220 image quality not very good fixed
|
||
Canon 1240 gray mode too bright fixed
|
||
|
||
HP 2100c hits against scan-bed fixed
|
||
Genius Devices not recognized fixed
|
||
EPSON Photo Permanently warmup on TPA scanning fixed
|
||
EPSON Photo Transparency mode does not work fixed
|
||
correctly
|
||
all binary mode does not work correctly done
|
||
Canon 16bit gray mode does not work done
|
||
EPSON 1250/60 Motor control settings are wrong fixed
|
||
CanoScan 1240 added
|
||
EPSON + HP vertical line bug fixed
|
||
HP blooming on 42bit >=400dpi fixed
|
||
UMAX5400 bad picture quality fixed
|
||
UMAX3400 Straight Line Bug fixed
|
||
|
||
Make the color modes > 8bit work correctly done
|
||
make mono/gray modes work on Canon scanners done
|
||
copy picture line by line to backend done
|
||
cancel function does not work correctly in large resolutions fixed
|
||
Move documents to its correct SANE place done
|
||
|