kopia lustrzana https://gitlab.com/sane-project/backends
300 wiersze
8.1 KiB
Plaintext
300 wiersze
8.1 KiB
Plaintext
Plustek.changes - Gerhard Jaeger <gerhard@gjaeger.de>
|
|
=====================================================
|
|
|
|
Note: All other not mentioned builds have never been released.
|
|
|
|
V 0.52-9 (2009-04-27)
|
|
---------------------
|
|
Tweaked highspeed settings for Epson 1260
|
|
|
|
V 0.52-8 (2008-08-25)
|
|
---------------------
|
|
Added preliminary support for Visioneer XP100
|
|
Tweaked entry for LM9831 version of Plustek UT12
|
|
|
|
V 0.52-7 (2007-12-13)
|
|
---------------------
|
|
Fixed alignment issues for archs like XScale/ARM
|
|
Fixed dumppic function to get valid grayscale pictures
|
|
|
|
V 0.52-6 (2007-11-23)
|
|
---------------------
|
|
Tweaked TravelScan464 settings.
|
|
Improved AFE gain calculation for CIS devices. This should avoid
|
|
stripes in the scanned images.
|
|
|
|
V 0.52-4 (2007-11-16)
|
|
---------------------
|
|
Tweaked TravelScan464 settings
|
|
Added possibility to disable dark-calibration with lamp on
|
|
(touches devices like CanoScan1220 etc)
|
|
Use attribute packed for data access structs
|
|
|
|
V 0.52-4 (2007-11-07)
|
|
---------------------
|
|
Added support for Syscan TravelScan464
|
|
|
|
V 0.52-3 (2007-07-26)
|
|
---------------------
|
|
Checked UMAX3400/3450 models
|
|
Force output bit set (MIO), when lamp is switched
|
|
|
|
V 0.52-2 (2007-07-10)
|
|
---------------------
|
|
Added flag to allow only 1- and 8-bit scanmodes. The Q-Scan does
|
|
not seem to support 14-bit modes.
|
|
|
|
V 0.52-1 (2007-06-29)
|
|
---------------------
|
|
|
|
Added sheetfed device Q-Scan USB001 from Portable Peripherals
|
|
Fixed Mustek Bearpaw and did some speedup (bugreports #304343 and
|
|
#301763)
|
|
Fixed calibration for senororders other that RGB
|
|
|
|
V 0.51-16 (2007-03-05)
|
|
----------------------
|
|
|
|
Added CanoScan to all Canon device strings.
|
|
Identified one more Plustek device as U24.
|
|
Fixed button handling for Plustek/KYE devices and
|
|
added some more debug messages.
|
|
|
|
V 0.51-15 (2006-11-22)
|
|
----------------------
|
|
Fixed option descriptors (bugreport #303786)
|
|
|
|
V 0.51-14 (2006-08-11)
|
|
----------------------
|
|
Lowered speed for LiDE20/30 models in low resolution mode (<75dpi)
|
|
|
|
V 0.51-13 (2006-08-09)
|
|
----------------------
|
|
Changed sane.type to "flatbed scanner" only
|
|
Fixed motorsettings for LiDE30 (bugreport #303722)
|
|
Fixed LiDE20 settings. Got some reports of non-working devs, although
|
|
my N670U is working fine. Lowered the max speeds and increased the
|
|
MCLK-div for fast movement. (bugreport #303695)
|
|
|
|
V 0.51-12 (2006-06-30)
|
|
----------------------
|
|
Fixed bit-depth selection
|
|
|
|
V 0.51-11 (2006-06-08)
|
|
----------------------
|
|
Fixed calibration: All modes will be coarse calibrated now, fine calibration
|
|
will be done only for 8 bit modes.
|
|
Fixed paper eject during startup.
|
|
|
|
V 0.51-10 (2006-05-28)
|
|
---------------------
|
|
Released
|
|
|
|
V 0.51-8 (2006-04-09)
|
|
---------------------
|
|
Added cache for fine calibration (CIS devices only)
|
|
Added support for sheet-fed scanner (CIS devices only)
|
|
Added support for Syscan TravelScan662
|
|
|
|
V 0.50-10 (2006-01-31)
|
|
---------------------
|
|
Fixed CanoScan N1220U settings.
|
|
|
|
V 0.50-9 (2006-01-19)
|
|
---------------------
|
|
Added high-speed setting for HP2200.
|
|
Fixed constraint_type for OPT_BUTTON.
|
|
|
|
V 0.50-8 (2006-01-18)
|
|
---------------------
|
|
Fixed CanoScan N670U settings (bugreport #302433).
|
|
|
|
V 0.50-7 (2005-10-28)
|
|
---------------------
|
|
Changed high-speed setting for UMAX 3400, due to bugreport #302317.
|
|
Added disable speeup feature (as option).
|
|
Fixed CanoScan N650U settings (bugreport #302433).
|
|
|
|
V 0.50-6 (2005-10-25)
|
|
---------------------
|
|
Fixed segfault in fine calibration for CIS devices.
|
|
Tweaked LiDE25 settings (thanks to Gerd Cendelin for lending me
|
|
his LiDE25).
|
|
Let 1200DPI CIS devices use now the green-channel for gray scans.
|
|
|
|
V 0.50-5 (2005-10-21)
|
|
---------------------
|
|
Fixed high-speed feature of CanoScan D660U.
|
|
|
|
V 0.50-4 (2005-10-02)
|
|
---------------------
|
|
Updated motor settings for Canoscan LiDE25, thanks to
|
|
Stephan February <stephanf@singnet.com.sg> for providing these
|
|
values.
|
|
|
|
V 0.50-3 (2005-08-22)
|
|
---------------------
|
|
Fixed problem, when trying to scan at resolutions beyond the
|
|
optical one (sensor stops too early)
|
|
|
|
V 0.50-2 (2005-08-19)
|
|
---------------------
|
|
More cleanup.
|
|
Removed obsolete _WAF_BLACKFINE.
|
|
LiDE20 does not seem to have a reliable black calibration area,
|
|
so the devices now will switch off the lamp for dark calibration.
|
|
Fixed line statistics and added calibration data output.
|
|
|
|
V 0.50-1 (2005-08-15)
|
|
---------------------
|
|
Cleanup
|
|
Activated IPC between reader-process and parent
|
|
Added button support for Plustek/Genius devices
|
|
Did some whitespace cleanup and removed those *p typedefs
|
|
Tried to improve CIS calibration (somewhat back to 1.0.13)
|
|
Added _TWEAK_GAIN definition to allow CIS calibration increase
|
|
gain values during basic lamp setup phase
|
|
Added call to speedtest to CIS calibration
|
|
Fixed CanoScan startup problem (the way misc I/Os will be set
|
|
after power-up has done the trick)
|
|
|
|
V 0.49-8 (2005-08-08)
|
|
---------------------
|
|
Added LiDE25 settings
|
|
|
|
V 0.49-7 (2005-07-21)
|
|
---------------------
|
|
Bugfix release - fixed lampsettings for CIS calibration
|
|
|
|
V 0.49-6 (2005-07-07)
|
|
---------------------
|
|
Bugfix release - calibration and segfault :(
|
|
|
|
V 0.49-5 (2005-07-04)
|
|
---------------------
|
|
Added IPC between reader-process and parent process to
|
|
be pepared for sharing calibration info.
|
|
Added button support for backend
|
|
|
|
V 0.49-4 (2005-06-27)
|
|
---------------------
|
|
Fixed "double free" problem during sane_exit.
|
|
|
|
V 0.49-3 (2005-04-18)
|
|
---------------------
|
|
Fixed backtracking problem, when sensor-speedup is active.
|
|
|
|
V 0.49-2 (2005-01-12)
|
|
---------------------
|
|
Tweaked some device settings
|
|
Updated copyright info
|
|
Using now PhyDpi.y as selector for the motor MCLK range
|
|
|
|
V 0.49-1 (2004-11-19)
|
|
---------------------
|
|
Improved multi-device capability
|
|
|
|
V 0.48-10 (2004-10-30)
|
|
----------------------
|
|
- Fixed a bug in buffer calculation for CIS devices
|
|
|
|
V 0.48-9 (2004-10-19)
|
|
---------------------
|
|
- Use the same option names for RGB gain as umax_pp backend
|
|
|
|
V 0.48-8 (2004-10-06)
|
|
---------------------
|
|
- split scanmodes & bit-depths
|
|
|
|
V 0.48-7 (2004-10-04)
|
|
---------------------
|
|
- changed some strings according to bug #300963
|
|
|
|
V 0.48-6 (2004-09-07)
|
|
---------------------
|
|
- fixed UMAX lamp-off bug
|
|
|
|
V 0.48-4 (2004-07-26)
|
|
---------------------
|
|
- added speedup parameters for UMAX3400/3450
|
|
- added disableSpeedup option
|
|
- added UMAX3400/3450 TPA autodetection
|
|
|
|
V 0.48-3 (2004-07-16)
|
|
---------------------
|
|
- improved autowarmup feature
|
|
- improved speedup feature
|
|
|
|
V 0.48-2 (2004-07-07)
|
|
---------------------
|
|
- fixed binary mode for CanoScan D660U
|
|
|
|
V 0.48-1 (2004-07-02)
|
|
---------------------
|
|
- added more options to the frontend interface
|
|
- added UMAX 3400 with product ID 0x0050
|
|
- added support for the UMAX 3450
|
|
- added autowarmup for CFL (most CCD-scanner)
|
|
- added speedup for sensor for some devices
|
|
- fixed lamp switching problem for D660U
|
|
- fixed negative scanning lamp problem
|
|
- fixed Gray 16 mode for CanoScan D660U
|
|
- code cleanup
|
|
|
|
V 0.47-11 (2004-04-21)
|
|
----------------------
|
|
- minor fixes, esp. for MacOSX
|
|
- added lamp-off and warmup options to be configurable by backends
|
|
|
|
V 0.47-8 - 0.47-10
|
|
------------------
|
|
- never released
|
|
|
|
V 0.47-7 (2004-02-08)
|
|
---------------------
|
|
- fixed bypass calibration function for CIS devices
|
|
- added lampoff stuff to config file
|
|
|
|
V 0.47-6 (2004-01-21)
|
|
---------------------
|
|
- Cleanup work
|
|
- Changed lamp off timer for non-setitimer systems
|
|
|
|
V 0.47-5 (2004-01-09)
|
|
---------------------
|
|
- Added big-endian code to support also PPC architectures
|
|
- Added mov (model override) to support various devices using
|
|
the same product ID (namely Mustek BearPaw 1200)
|
|
- Added per-model gamma values
|
|
- Fixed a bug in the coarse CIS-lamp calibration
|
|
- Cleanup work
|
|
|
|
V 0.47-1 - 0.47-4
|
|
-----------------
|
|
- never released
|
|
|
|
V 0.46-9 (2003-11-03)
|
|
---------------------
|
|
- Added alternate calibration for CIS devices
|
|
- Added coarse calibration data-cache
|
|
- Moved parallelport code to extra backend file plustek_pp
|
|
- Fixed some minor bugs
|
|
- Fixed problem with CIS devices using FreeBSD
|
|
|
|
V 0.46-1 - 0.46-8
|
|
-----------------
|
|
- never released
|
|
|
|
V 0.45 (2003-08-05)
|
|
-------------------
|
|
- Starting this changelog
|
|
- Updates since V 0.44:
|
|
* better CIS device support
|
|
* added CanoScan N1220U, N1240U
|
|
* made CanoScan N650U and N670U work
|
|
* fixed EPSON 1260 motor killer-bug
|
|
* improved TPA scanning
|
|
* fixed TPA warmup bug on EPSON 1260/Photo
|
|
* fixed Genius device detection problem
|
|
* Added Compaq S4-100 (identical to UMAX3400)
|