sane-project-backends/doc/sane-plustek.man

551 wiersze
13 KiB
Groff

.TH sane-plustek 5 "24 January 2002"
.IX sane-plustek
.SH NAME
sane-plustek
.br
SANE backend for Plustek parallel port and
.br
LM983[1/2/3] based USB flatbed scanners
.SH DESCRIPTION
The
.B sane-plustek
library implements a SANE (Scanner Access Now Easy) backend that
provides access to Plustek parallel port and USB flatbed scanners.
The USB support is part of the SANE package but for usage with
parallel port scanners you will need a kernel module, called
pt_drv which currently can be downloaded from
.br
.B http://home.t-online.de/home/g-jaeger/plustek.html
.SH "PARALLEL PORT SUPPORT"
At present, the following scanners should work with this backend
and the corresponding kernel module:
.PP
.B "PLUSTEK SCANNERS"
.PP
Parallelport Model: ASIC: Properties:
.br
---------------------- ----- ------------------------
.br
OpticPro PT12 98003 600x1200 dpi 36bit 512Kb
.br
OpticPro P12 98003 600x1200 dpi 36bit 512Kb
.br
OpticPro 9636T/12000T 98001 600x1200 dpi 36bit 512Kb
.br
OpticPro 12000P Turbo 98001 600x1200 dpi 36bit 512Kb
.br
OpticPro 9636P+/Turbo 98001 600x1200 dpi 36bit 512Kb
.br
OpticPro 9636P 98001 600x1200 dpi 36bit 512Kb
.br
OpticPro 12000P/96000P 96003 600x1200 dpi 30bit 128Kb
.br
OpticPro 1236P 96003 600x1200 dpi 30bit 128Kb
.br
OpticPro 9600P 96003 600x1200 dpi 30bit 128Kb
.br
OpticPro 9630P/FBIV 96003 600x1200 dpi 30bit 128Kb
.br
OpticPro 9630PL (14") 96003 600x1200 dpi 30bit 128Kb
.br
OpticPro A3I 96003 400x800 dpi 30bit 128Kb
.br
OpticPro 600P/6000P 96003 300x600 dpi 30bit 32Kb
.br
OpticPro 4831P 96003 300x600 dpi 30bit 32Kb
.br
OpticPro 4830P/FBIII 96003 300x600 dpi 30bit 32Kb
.br
OpticPro 4800P/FBII 96001 300x600 dpi 24bit 32Kb
.br
.PP
.B "PRIMAX SCANNERS"
There are some scanners sold by Primax, but they are in fact
Plustek devices. These scanners are also supported.
The following table will show the relationship:
.PP
Model: Plustek Model: Remarks:
.br
--------------------------- -------------- ------------
.br
Colorado 4800 OpticPro 4800 not tested
.br
Compact 4800 Direct OpticPro 600 mov=2
.br
Compact 4800 Direct 30bit OpticPro 4830 not tested
.br
Compact 9600 Direct 30bit OpticPro 9630 works
.PP
.B "GENIUS SCANNERS"
The following devices are sold as Genius Scanners, but are in fact
Plustek devices.
The table will show the relationship:
.PP
Model: Remarks:
.br
--------------------------- ----------------------------
.br
Colorpage Vivid III V2 Like P12 but has two buttons
.br
and Wolfson DAC
.PP
.B "ARIES SCANNERS"
There's one scanner sold as Aries Scanner, but is in fact a
Plustek device.
The following table will show the relationship:
.PP
Model: Plustek Model: Remarks:
.br
--------------------------- -------------- ------------
.br
Scan-It 4800 OpticPro 600 mov=2
.PP
.B "BrightScan SCANNERS"
There's one scanner sold as BrightScan OpticPro Scanner, this is also
rebadged Plustek device.
The following table will show the relationship:
.PP
Model: Remarks:
.br
--------------------------- ----------------------------
.br
BrightScan OpticPro OpticPro P12
.SH "USB SUPPORT"
The Backend is able to support USB scanner based on the National
Semiconductor chipset LM9831, LM9832 and LM9833. The following tables
show various devices which are currently reported to work.
.br
Vendor Plustek - ID: 0x07B3
.br
----------------------------------------------------------
.br
USB Model: ASIC: Properties: Prod-ID
.br
----------------------------------------------------------
.br
OpticPro U12 LM9831 600x1200dpi 42bit 512Kb 0x0010
.br
OpticPro UT12 LM9832 600x1200dpi 42bit 512Kb 0x0017
.br
OpticPro UT16 LM9832 600x1200dpi 42bit 512Kb 0x0017
.br
OpticPro U24 LM9831 1200x2400dpi 42bit 2Mb 0x0011
.br
OpticPro UT24 LM9832 1200x2400dpi 42bit 2Mb 0x0017
.PP
Vendor KYE/Genius - ID: 0x0458
.br
----------------------------------------------------------
.br
USB Model: ASIC: Properties: Prod-ID
.br
----------------------------------------------------------
.br
Colorpage HR6 V2 LM9832 600x1200dpi 42bit 512Kb 0x2007
.PP
Vendor Hewlett-Packard - ID: 0x03F0
.br
----------------------------------------------------------
.br
USB Model: ASIC: Properties: Prod-ID
.br
----------------------------------------------------------
.br
ScanJet 2200c LM9832 600x1200dpi 42bit 512Kb 0x0605
.PP
Vendor Mustek - ID: 0x0400
.br
----------------------------------------------------------
.br
USB Model: ASIC: Properties: Prod-ID
.br
----------------------------------------------------------
.br
BearPaw 1200 LM9831 600x1200dpi 42bit 512Kb 0x1000
.br
BearPaw 2400 LM9832 1200x2400dpi 42bit 2Mb 0x1001
.PP
.SH "OTHER PLUSTEK SCANNERS"
The SCSI scanner OpticPro 19200S is a rebadged Artec AM12S scanner
and is supported by the
.B Artec
backend.
.br
Only the National Semiconductor LM9831/2 based devices of Plustek
are supported by this driver. Older versions of the UT12, the U1212
and U1248 (GrandTech chipset are not supported)
.PP
.SH "DEVICE NAMES"
This backend expects a default device called:
.PP
.RS
.I /dev/pt_drv
.RE
.PP
This default device will be used, if no configuration
file can be found.
.PP
The device-driver is currently not part of the SANE distribution.
It has to be downloaded from:
.br
.B http://home.t-online.de/home/g-jaeger/plustek.html
.br
See the INSTALL file there for a proper setup. Currently only Linux
is supported by this driver (Kernel 2.2.x and higher).
.PP
As the backend and the driver support up to four devices
per system, it is possible to specify them in the configuration
file
.PP
.RS
.I @CONFIGDIR@/plustek.conf
.RE
.PP
See the plustek.conf file for examples.
.PP
.SH "CONFIGURATION"
.PP
The configuration of this backend can be divided into two sections:
.br
.PP
.B "CONFIGURATION - parallel port scanner"
.PP
.br
.B "CONFIGURATION - USB scanner"
.PP
.br
Please make sure, that the configuration matches the real world,
namely your configuration.
.PP
.SH "CONFIGURATION - PARALLEL PORT SCANNER"
.PP
Beside the kernel-module options, which are described below, you
need to enable the parallel port device in the configuration file
.PP
.RS
.I @CONFIGDIR@/plustek.conf
.RE
.PP
For a proper setup, you will need at least two entries:
.TP
.I [parport]
.TP
.I device /dev/pt_drv
.PP
.I parport
tells the backend, that the following devicename (here
.I /dev/pt_drv
) has to be interpreted as parallel port scanner device.
.PP
To have this device, you will need to setup the kernel module.
As the driver is a loadable kernel module, it is configured
by invoking insmod with the appropriate parameters or
appending the options to the file
.B /etc/conf.modules
.PP
.B
The Options:
.br
lampoff=lll
.RS
The value
.I lll
tells the driver, after how many seconds to
switch-off the lamp(s). The default value is 180.
0 will disable this feature.
.br
.B HINT:
Do not use a value that is too small, because often
switching on/off the lamps will reduce their lifetime.
.RE
.PP
port=ppp
.RS
.I ppp
specifies the port base address, where the scanner
is connected to. The default value is 0x378 which
normaly is standard.
.RE
.PP
warmup=www
.RS
.I www
specifies the time in seconds, how long a lamp has to be on,
until the driver will start to scan. The default value is 30.
.RE
.PP
lOffonEnd=e
.RS
.I e
specifies the behaviour when unloading the driver, 1 --> switch
lamps off, 0 --> do not change lamp status
.RE
.PP
slowIO=s
.RS
.I s
specifies which I/O functions the driver should use, 1 --> use
delayed functions, 0 --> use the non-delayed ones
.RE
.PP
forceMode=fm
.RS
.I fm
specifies port mode which should be used, 0 --> autodetection,
1 --> use SPP mode and 2 --> use EPP mode
.RE
.PP
mov=m
.RS
.I m
=0 - default: no override
.br
.I m
=1 - OpticPro 9630PL override (works if OP9630
.br
has been detected) forces legal size (14")
.br
.I m
=2 - Primax 4800Direct override (works if OP600
.br
has been detected) swaps red/green color
.br
.I m
=3 - OpticPro 9636 override (works if OP9636 has
.br
been detected) disables backends
.br
transparency/negativ capabilities
.br
.I m
=4 - OpticPro 9636P override (works if OP9636 has
.br
been detected) disables backends
.br
transparency/negativ capabilities
.br
.I m
=5 - OpticPro A3I override (works if OP12000 has
.br
been detected) enables A3 scanning
.br
.I m
=6 - OpticPro 4800P override (works if OP600
.br
has been detected) swaps red/green color
.br
.RE
.PP
Sample entry for file
.B "/etc/modules.conf"
:
.br
.I alias char-major-40 pt_drv
.br
.I pre-install pt_drv modprobe -k parport
.br
.I options pt_drv lampoff=180 warmup=15 port=0x378 lOffonEnd=0 mov=0 slowIO=0 forceMode=0
.PP
For multidevice support, simply add values separated by commas to
the different options
.br
.I options pt_drv port=0x378,0x278 mov=0,4 slowIO=0,1 forceMode=0,1
.PP
Remember to call depmod after changing /etc/conf.modules.
.PP
.B "PARALLEL PORT MODES"
.PP
The current driver works best, when the parallel port
has been set to EPP-mode. When detecting any other
mode such as ECP or PS/2 the driver tries to set to a
faster, supported mode. If this fails, it will use the
SPP mode, as this mode should work with all Linux supported
parallel ports.
.PP
Former Plustek scanner models (4830, 9630) supplied a
ISA parallel port adapter card. This card is
.BR not
supported by the driver.
.PP
The ASIC 96001/3 based models have sometimes trouble with
high resolution modes. If you encounter sporadic corrupted
images (parts duplicated or shifted horizontally) kill all
other applications before scanning and (if sufficient
memory available) disable swapping.
.PP
.SH "CONFIGURATION - USB SCANNER"
.PP
To use the USB device with this backend, you need at least
two entries in the configuration file
.br
.I @CONFIGDIR@/plustek.conf
.TP
.I [usb] vendor-id product-id
.TP
.I device /dev/usbscanner
.PP
.I usb
tells the backend, that the following devicename (here
.I /dev/usbscanner
) has to be interpreted as USB scanner device. If vendor- and
product-id has not been specified, the backend tries to
detect this by its own.
.PP
See the plustek.conf file for examples.
.PP
.B Note:
.br
You have to make sure, that the USB subsystem is loaded
correctly and the module
.I scanner
has been loaded too. To make this module recognize your
scanner, you might have to add the following line to
your
.B "/etc/modules.conf"
:
.br
.I options scanner vendor=0x7b3 product=0x17
.PP
.br
If you're not sure about the vendor and product id of your
device, simply load the USB subsystem and plug in your
scanner. Then do a
.I cat /proc/bus/usb/devices
and look for the scanner.
.PP
.SH FILES
.TP
.I @CONFIGDIR@/plustek.conf
The backend configuration file
.TP
.I @LIBDIR@/libsane-plustek.a
The static library implementing this backend.
.TP
.I @LIBDIR@/libsane-plustek.so
The shared library implementing this backend (present on systems that
support dynamic loading).
.TP
.I /lib/modules/<Kernel-Version>/misc/pt_drv.o
The Linux Kernelmodule.
.PP
.SH "CONTACT AND BUG-REPORTS"
.PP
Please send any information and bug-reports to:
.br
.B Plustek Driver Mailing List <plustek@linuxhacker.org>
.br
or directly to:
.br
.B Gerhard Jaeger <g.jaeger@earthling.net>
.PP
Additional info and hints can be obtained from our
.br
Mailing-List archive at:
.br
.B http://www.linuxhacker.org/cgi-bin/ezmlm-cgi/3
.PP
or directly from the projects' homepage at:
.br
.B http://home.t-online.de/home/g-jaeger/plustek.html
.PP
.SH "BUGS & RESTRICTIONS"
.PP
.br
* The Halftoning works, but the quality is poor
.br
* Printers (especially HP models) will start to
.br
print during scanning. This in fact is a problem
.br
to other printers too, using bidirectional protocol
.br
(see www.plustek.com (TAIWAN) page for further details)
.br
* The driver does not support these manic scalings up
.br
to 16 times the physical resolution. The only scaling
.br
is done on resolutions between the physical resolution
.br
of the CDD-sensor and the stepper motor i.e. you have a
.br
600x1200 dpi scanner and you are scanning using 800dpi,
.br
so scaling is necesary, because the sensor only delivers
.br
600dpi but the motor is capable to perform 800dpi steps.
.br
* On some devices, the pictures seems to be bluished
.PP
ASIC 98001 based models:
.br
* The 300dpi transparency and negative mode does not work
.br
correctly.
.br
* There is currently no way to distinguish a model with
.br
and without transpareny unit.
.br
* The scanned images seem to be too dark (P9636T)
.PP
ASIC 96003/1 based models:
.br
* 30bit mode is currently not supported.
.br
* On low-end systems and under heavy system load, the
.br
driver will loosing data, this might causes the sensor
.br
to hit the scan-bed and/or the picture is corrupted.
.br
* The scanspeed on 600x1200 dpi models is slow.
.br
* The scanquality of the A3I is poor
.br
.PP
USB models:
.br
* Plusteks' model policy is somewhat inconsistent. This
.br
means, they sell technical different devices under the
.br
same product name. Therefore it is possible that some
.br
devices like the UT12 or U12 won't work - please check
.br
the model list above and compare the product-id to
.br
the one your device has.