kopia lustrzana https://gitlab.com/sane-project/backends
147 wiersze
4.7 KiB
Groff
147 wiersze
4.7 KiB
Groff
.TH sane-st400 5 "08 Mar 1999" "@PACKAGEVERSION@" "SANE Scanner Access Now Easy"
|
|
.IX sane-st400
|
|
.SH NAME
|
|
sane-st400 \- SANE backend for Siemens ST/Highscan flatbed scanners
|
|
.SH DESCRIPTION
|
|
The
|
|
.B sane-st400
|
|
library implements a SANE (Scanner Access Now Easy) backend that
|
|
provides access to Siemens ST400 flatbed scanners and compatibles.
|
|
At present, the following scanners are supported by this backend:
|
|
.PP
|
|
.RS
|
|
Siemens ST400 (6 bit gray scale)
|
|
.br
|
|
Siemens ST800 (6 bit gray scale)
|
|
.br
|
|
.RE
|
|
.PP
|
|
The driver supports line art and gray scans up to 8bpp.
|
|
.PP
|
|
The Siemens ST/Highscan series includes several more models, e.g. the ST300
|
|
and ST600. If you own one of these scanners, or a scanner other than the
|
|
ones listed above that works with this backend, please let us know by sending
|
|
the scanner's model name, SCSI ID, and firmware revision to
|
|
.IR sane\-devel@mostang.com .
|
|
Have a look at http://www.mostang.com/sane/mail.html concerning subscription
|
|
to sane-devel.
|
|
|
|
.SH "DEVICE NAMES"
|
|
This backend expects device names of the form:
|
|
.PP
|
|
.RS
|
|
.I special
|
|
.RE
|
|
.PP
|
|
Where
|
|
.I special
|
|
is either the path-name for the special device that corresponds to a
|
|
SCSI scanner. For SCSI scanners, the special device name must be a
|
|
generic SCSI device or a symlink to such a device. Under Linux, such
|
|
a device name could be
|
|
.I /dev/sga
|
|
or
|
|
.IR /dev/sge ,
|
|
for example. See sane-scsi(5) for details.
|
|
.SH CONFIGURATION
|
|
The contents of the
|
|
.I st400.conf
|
|
file is a list of device names that correspond to Siemens
|
|
scanners. Empty lines and lines starting with a hash mark (#) are
|
|
ignored. A sample configuration file is shown below:
|
|
.PP
|
|
.RS
|
|
/dev/scanner
|
|
.br
|
|
# this is a comment
|
|
.br
|
|
/dev/sge
|
|
.RE
|
|
.PP
|
|
The default configuration file that is distributed with SANE looks like
|
|
this:
|
|
.PP
|
|
.RS
|
|
scsi SIEMENS "ST 400" Scanner * * 3 0
|
|
.RE
|
|
.PP
|
|
In this configuration, the driver can only access the ST400 model
|
|
at SCSI ID 3 LUN 0 (see section "BUGS" below for the reason).
|
|
To use the driver with other scanner models, add an appropriate line to
|
|
the configuration file. For example, to use it with an ST800 at SCSI
|
|
ID 3 LUN 0, add the line:
|
|
.PP
|
|
.RS
|
|
scsi SIEMENS "ST 800" Scanner * * 3 0
|
|
.RE
|
|
|
|
.SH FILES
|
|
.TP
|
|
.I @CONFIGDIR@/st400.conf
|
|
The backend configuration file (see also description of
|
|
.B SANE_CONFIG_DIR
|
|
below).
|
|
.TP
|
|
.I @LIBDIR@/libsane-st400.a
|
|
The static library implementing this backend.
|
|
.TP
|
|
.I @LIBDIR@/libsane-st400.so
|
|
The shared library implementing this backend (present on systems that
|
|
support dynamic loading).
|
|
.SH ENVIRONMENT
|
|
.TP
|
|
.B SANE_CONFIG_DIR
|
|
This environment variable specifies the list of directories that may
|
|
contain the configuration file. Under UNIX, the directories are
|
|
separated by a colon (`:'), under OS/2, they are separated by a
|
|
semi-colon (`;'). If this variable is not set, the configuration file
|
|
is searched in two default directories: first, the current working
|
|
directory (".") and then in /etc/sane.d. If the value of the
|
|
environment variable ends with the directory separator character, then
|
|
the default directories are searched after the explicitly specified
|
|
directories. For example, setting
|
|
.B SANE_CONFIG_DIR
|
|
to "/tmp/config:" would result in directories "tmp/config", ".", and
|
|
"/etc/sane.d" being searched (in this order).
|
|
.TP
|
|
.B SANE_DEBUG_ST400
|
|
If the library was compiled with debug support enabled, this environment
|
|
variable controls the debug level for this backend. E.g., a value of 128
|
|
requests all debug output to be printed. Smaller levels reduce verbosity.
|
|
|
|
.SH MISSING FUNCTIONALITY
|
|
|
|
Everything but the most basic stuff.
|
|
|
|
.SH BUGS
|
|
Currently, the backend does not check if the attached device really is
|
|
a ST400. It will happily accept everything that matches the configuration
|
|
entries. This makes it easy to test the backend with other scanners:
|
|
Just add an appropriate line to the configuration file. The configuration
|
|
file as distributed (see above) only works with the ST400. Be careful:
|
|
If there is no config file at all, the backend defaults to /dev/scanner.
|
|
.PP
|
|
The ST400 answers on all eight SCSI LUNs. Normally this is not a problem,
|
|
as LUN support is usually disabled in SCSI drivers, but if you are seeing
|
|
multiple instances of the scanner in a device list, either disable LUNs in
|
|
your SCSI setup or change the entry in the configuration file to match
|
|
LUN 0 only.
|
|
|
|
.SH DEBUG
|
|
If you encounter a bug please set the environment variable
|
|
SANE_DEBUG_ST400 to 128 and try to regenerate the problem. Then
|
|
send me a report with the log attached.
|
|
.PP
|
|
If you encounter a SCSI bus error or trimmed and/or displaced images please
|
|
also set the environment variable SANE_DEBUG_SANEI_SCSI to 128 before sending
|
|
me the report.
|
|
|
|
.SH "SEE ALSO"
|
|
sane(7), sane\-scsi(5)
|
|
.br
|
|
http://www.informatik.uni-oldenburg.de/~ingo/sane/
|
|
|
|
.SH AUTHOR
|
|
|
|
Ingo Wilken <Ingo.Wilken@informatik.uni\-oldenburg.de>
|