kopia lustrzana https://gitlab.com/sane-project/backends
312 wiersze
11 KiB
Groff
312 wiersze
11 KiB
Groff
.TH sane-epson 5 "27-Dec-2000" "@PACKAGEVERSION@" "SANE Scanner Access Now Easy"
|
|
.IX sane-epson
|
|
.SH NAME
|
|
sane-epson \- SANE backend for EPSON scanners
|
|
.SH DESCRIPTION
|
|
The
|
|
.B sane-epson
|
|
library implements a SANE (Scanner Access Now Easy) backend that
|
|
provides access to Epson flatbed scanners. Some functions of this
|
|
backend should be considered
|
|
.B beta-quality
|
|
software! Most functions have been stable for a long time, but of
|
|
course new development can not and often times will not function properly from
|
|
the very first day. Please report any strange behavior to the
|
|
maintainer of the backend.
|
|
.PP
|
|
At present, the following scanners are known to work with this backend:
|
|
.PP
|
|
.RS
|
|
Model: Connection Type
|
|
.br
|
|
--------------------------- -------------------
|
|
.br
|
|
GT-5000 parallel
|
|
.br
|
|
GT-6000 parallel
|
|
.br
|
|
ActionScanner II parallel
|
|
.br
|
|
GT-7000 SCSI
|
|
.br
|
|
Perfection 636 SCSI
|
|
.br
|
|
Perfection 636U USB
|
|
.br
|
|
Perfection 610 USB
|
|
.br
|
|
Perfection 640 USB
|
|
.br
|
|
Perfection 1200S SCSI
|
|
.br
|
|
Perfection 1200U USB
|
|
.br
|
|
Perfection 1240 USB, SCSI
|
|
.br
|
|
Perfection 1640 USB, SCSI
|
|
.br
|
|
Perfection 1650 USB
|
|
.br
|
|
Perfection 1660 USB
|
|
.br
|
|
Perfection 2400 USB
|
|
.br
|
|
Perfection 2450 USB, IEEE-1394
|
|
.br
|
|
Expression 636 / GT-9500 SCSI
|
|
.br
|
|
Expression 1600 USB, SCSI, IEEE-1394
|
|
.br
|
|
Expression 1680 USB, SCSI, IEEE-1394
|
|
.RE
|
|
|
|
For other scanners the software may or may not work. Please send mail to
|
|
the backend author (khk@khk.net) to report success with scanners not on
|
|
the list or problems with scanners that are listed.
|
|
.SH OPTIONS
|
|
The options the backend supports can either be selected through command line
|
|
options to programs like scanimage or through GUI elements in programs like
|
|
xscanimage or xsane.
|
|
|
|
Valid command line options and their syntax can be listed by using
|
|
.RS
|
|
scanimage --help -d epson
|
|
.RE
|
|
Not all devices support all options.
|
|
.TP
|
|
.I Scan Mode
|
|
The
|
|
.I --mode
|
|
switch selects the basic mode of operation of the scanner. Valid choices
|
|
are Binary, Gray and Color. The Binary mode is black and white only,
|
|
Gray will produce 256 levels of gray or more depending on the scanner
|
|
and Color means 24 bit color mode or more depending on the scanner.
|
|
Some scanners will internally use 36 bit color, their external interface
|
|
however may only support 24 bits.
|
|
|
|
The
|
|
.I --depth
|
|
option selects the bit depth the scanner is using. This option is only
|
|
available for scanners that support more than one bit depth. Older
|
|
scanners will always transfer the image in 8bit mode. Newer scanners
|
|
allow to select either 8 bits, 12 or 14 bits per color channel. For a
|
|
color scan this means an effective color depth of 36 or 42 bits over
|
|
all three channels. The valid choices depend on the scanner model.
|
|
|
|
The
|
|
.I --halftoning
|
|
switch selects the mode that is used in Binary mode. Valid options
|
|
are "None", "Halftone A (Hard Tone)", "Halftone B (Soft Tone)", "Halftone C
|
|
(Net Screen)", "Dither A (4x4 Bayer)", "Dither B (4x4 Spiral)", "Dither C
|
|
(4x4 Net Screen)", "Dither D (8x4 Net Screen)", "Text Enhanced Technology",
|
|
"Download pattern A", and "Download pattern B".
|
|
|
|
The
|
|
.I --dropout
|
|
switch selects the so called dropout color. Vald options are None,
|
|
Red, Green and Blue. The default is None. The dropout color is used for
|
|
monochrome scanning and selects the color that is not scanned. This can
|
|
be used to e.g. scan an original with a colored background.
|
|
|
|
The
|
|
.I --brightness
|
|
switch controls the brightness of the scan. Valid options are integer
|
|
values from -3 to 3. The default is 0. The larger the brightness value,
|
|
the brighter the image gets. If a user defined table for the gamma
|
|
correction is selected, the brightness parameter is not available.
|
|
|
|
The
|
|
.I --sharpness
|
|
switch sets the sharpness of the image data. Valid options are integer
|
|
values from -2 to 2, with -2 meaning "Defocus", -1 "Defocus slightly",
|
|
0 "Normal", 1 "Sharpen slighly" and 2 "Sharpen".
|
|
|
|
The
|
|
.I --gamma-correction
|
|
switch controls the scanner's internal gamma correction. Valid options are
|
|
"Default", "User defined", "High density printing" "Low density printing"
|
|
and "High contrast printing".
|
|
|
|
The
|
|
.I --color-correction
|
|
switch controls the scanner's internal color correction function. Valid
|
|
options are "No Correction", "Impact-dot printers", "Thermal printers",
|
|
"Ink-jet printers" and "CRT monitors". The default is "CRT monitors".
|
|
|
|
The
|
|
.I --resolution
|
|
switch selects the resolution for a scan. Some EPSON scanners will scan in
|
|
any resulution between the lowest and highest possible value. The list
|
|
reported by the scanner can be displayed using the "--help -d epson"
|
|
parameters to scanimage.
|
|
|
|
The
|
|
.I --mirror
|
|
option controls the way the image is scanned. By reading the image data
|
|
from right to left the image is mirored. Valid options are "yes" and
|
|
"no". The default is "no".
|
|
|
|
The
|
|
.I --speed
|
|
option can improve the scan speed in monochrome mode. Valid options are
|
|
"yes" or "no", the "yes" option will speed up the scan if this option
|
|
is supported.
|
|
|
|
The
|
|
.I --auto-area-segmentation
|
|
switch activates the automatic area segmentation for monochrome scans. The
|
|
scanner will try to determine which areas are text and which contain
|
|
images. The image areas will be halftoned, and the text will be
|
|
impoved. Valid options are "yes" and "no". The default is "yes".
|
|
|
|
The
|
|
.I --gamma-table
|
|
parameter can be used to download a user defined gamma table. The option
|
|
takes 256 values from the range 0-255. In color mode this option equally
|
|
affects the red, green, and blue channel.
|
|
|
|
The
|
|
.I --red-gamma-table
|
|
parameter can be used to download a user defined gamma table for the
|
|
red channel. The valid options are the same as for --gamma-table.
|
|
|
|
The
|
|
.I --green-gamma-table
|
|
parameter can be used to download a user defined gamma table for the
|
|
green channel. The valid options are the same as for --gamma-table.
|
|
|
|
The
|
|
.I --blue-gamma-table
|
|
parameter can be used to download a user defined gamma table for the
|
|
blue channel. The valid options are the same as for --gamma-table.
|
|
|
|
The color correction coefficients
|
|
.I --cct-1 --cct-2 --cct-3 ... --cct-9
|
|
will install color correction coefficients for the user defined color
|
|
correction. Values are specified as integers in the range -127..127.
|
|
|
|
The
|
|
.I --preview
|
|
option requests a preview scan. The frontend software automatically selects a low
|
|
resolution. Valid options are "yes" and "no". The default is "no".
|
|
|
|
The
|
|
.I --preview-speed
|
|
options will increase the scan speed if this is supported by the
|
|
scanner. Valid options are "yes" and "no", the default is "no".
|
|
|
|
|
|
The geometry options
|
|
.I -l -t -x -y
|
|
control the scan area: -l sets the top left x coordinate, -t the top
|
|
left y coordinate, -x selects the width and -y the height of the scan
|
|
aea. All parameters are specified in milimeters.
|
|
|
|
The
|
|
.I --quick-format
|
|
option lets the user select a scan area with predefined sizes. Valid
|
|
parameters are "CD", "A5 portrait", "A5 landscape", "Letter", "A4" and
|
|
"max". The default is "max", which selects the largest possible area.
|
|
|
|
The
|
|
.I --source
|
|
option selects the scan source. Valid options depend on the installed
|
|
options. The default is "Flatbed".
|
|
|
|
The
|
|
.I --auto-eject
|
|
option will eject a page after scanning from the document feeder.
|
|
|
|
The
|
|
.I --film-type
|
|
option will select the film type for scans with the transparency
|
|
unit. This option is only activated if the TPU is selected as scan
|
|
source. Valid options are "Negative Film" and "Positive Film".
|
|
|
|
The
|
|
.I --focus-position
|
|
option selects the focus position for all scans. Valid options are "Focus
|
|
2.5mm above glass" and "Focus on glass". The focus on the 2.5mm point
|
|
above the glass is necessary for scans with the transparency unit, so
|
|
that the scanner can focus on the film if one of the film holders is used.
|
|
This option is only functional for selected scanners, all other scanners
|
|
will ignore this option.
|
|
|
|
|
|
.SH CONFIGURATION FILE
|
|
The configuration file @CONFIGDIR@/epson.conf specifies the device(s) that the
|
|
backend will use. Possible connection types are:
|
|
.TP
|
|
.I SCSI
|
|
This is the default, and if nothing else is specified the backend software will
|
|
open a given path as SCSI device. More information about valid syntax for SCSI
|
|
devices can be found in sane-scsi(5).
|
|
.TP
|
|
.I PIO - Parallel Interface
|
|
The parallel interface can be configured in two ways: An integer value starting
|
|
at the beginning of a line will be interpreted as the IO address of the parallel
|
|
port. To make it clearer that a configured IO address is a parallel port the
|
|
port address can be preceded by the string "PIO". The PIO connection does not
|
|
use a special device file in the /dev directory. The IO address can be specified
|
|
in hex mode (prefixed with "0x").
|
|
.TP
|
|
.I USB
|
|
A device file that is preceded by the string "USB" is treated as a scanner
|
|
connected via the Universal Serial Bus. The correct special device file has
|
|
to be created prior to using it with Sane. See the USB documentation for
|
|
more information about how to set up the USB subsystem and the required
|
|
device files.
|
|
.SH FILES
|
|
.TP
|
|
.I @LIBDIR@/libsane-epson.a
|
|
The static library implementing this backend.
|
|
.TP
|
|
.I @LIBDIR@/libsane-epson.so
|
|
The shared library implementing this backend (present on systems that
|
|
support dynamic loading).
|
|
.SH ENVIRONMENT
|
|
.TP
|
|
.B SANE_DEBUG_EPSON
|
|
If the library was compiled with debug support enabled, this
|
|
environment variable controls the debug level for this backend. E.g.,
|
|
a value of 128 requests all debug output to be printed. Smaller
|
|
levels reduce verbosity.
|
|
|
|
.TP
|
|
.B SANE_EPSON_CMD_LVL
|
|
This allows to override the function or command level that the backend
|
|
uses to communicate with the scanner. The function level a scanner
|
|
supports is determined during the initialization of the device. If
|
|
the backend does not recognize the function level reported by the
|
|
scanner it will default to function level B5. Valid function levels
|
|
are A1, A2, B1, B2, B3, B4, B5, B6, B7, B8, D1 and F5. Use this feature
|
|
only if you know what you are doing!
|
|
|
|
.SH "SEE ALSO"
|
|
|
|
sane\-scsi(5), scanimage(1), xscanimage(1), xsane(1)
|
|
|
|
.SH BUGS
|
|
|
|
None :-) At least none are currently known.
|
|
|
|
.SH UNSUPPORTED DEVICES
|
|
The backend may be used with Epson scanners that are not yet listed
|
|
under the list of supported devices. A scanner that is not recognized
|
|
may default to the function level B3, which means that not all
|
|
functions that the scanner may be capable of are accessible.
|
|
|
|
If the scanner is not even recognized as an Epson scanner this is
|
|
probably because the device name reported by the scanner is not in the
|
|
correct format. Please send this information to the backend maintainer
|
|
(email address is in the AUTHOR section of this man page or in the
|
|
AUTHORS file of the SANE distribution).
|
|
|
|
The Perfection 600, Perfection 650, Perfection 660, Perfection 1250 and
|
|
Perfection 1260 are not supported by this backend.
|
|
|
|
.SH AUTHOR
|
|
|
|
The package is actively maintained by Karl Heinz Kremer (khk@khk.net). The
|
|
software is based on work by Christian Bucher and Kazuhiro Sasayama
|