kopia lustrzana https://gitlab.com/sane-project/backends
244 wiersze
6.6 KiB
Plaintext
244 wiersze
6.6 KiB
Plaintext
Plustek.changes - Gerhard J<>er <gerhard@gjaeger.de>
|
||
====================================================
|
||
|
||
Note: All other not mentioned builds have never been released.
|
||
|
||
V 0.51-15 (2006-11-22)
|
||
----------------------
|
||
Fixed option descriptors (bugreport #303786)
|
||
|
||
V 0.51-14 (2006-08-11)
|
||
----------------------
|
||
Lowered speed for LiDE20/30 models in low resolution mode (<75dpi)
|
||
|
||
V 0.51-13 (2006-08-09)
|
||
----------------------
|
||
Changed sane.type to "flatbed scanner" only
|
||
Fixed motorsettings for LiDE30 (bugreport #303722)
|
||
Fixed LiDE20 settings. Got some reports of non-working devs, although
|
||
my N670U is working fine. Lowered the max speeds and increased the
|
||
MCLK-div for fast movement. (bugreport #303695)
|
||
|
||
V 0.51-12 (2006-06-30)
|
||
----------------------
|
||
Fixed bit-depth selection
|
||
|
||
V 0.51-11 (2006-06-08)
|
||
----------------------
|
||
Fixed calibration: All modes will be coarse calibrated now, fine calibration
|
||
will be done only for 8 bit modes.
|
||
Fixed paper eject during startup.
|
||
|
||
V 0.51-10 (2006-05-28)
|
||
---------------------
|
||
Released
|
||
|
||
V 0.51-8 (2006-04-09)
|
||
---------------------
|
||
Added cache for fine calibration (CIS devices only)
|
||
Added support for sheet-fed scanner (CIS devices only)
|
||
Added support for Syscan Travelscan662
|
||
|
||
V 0.50-10 (2006-01-31)
|
||
---------------------
|
||
Fixed CanoScan N1220U settings.
|
||
|
||
V 0.50-9 (2006-01-19)
|
||
---------------------
|
||
Added high-speed setting for HP2200.
|
||
Fixed constraint_type for OPT_BUTTON.
|
||
|
||
V 0.50-8 (2006-01-18)
|
||
---------------------
|
||
Fixed CanoScan N670U settings (bugreport #302433).
|
||
|
||
V 0.50-7 (2005-10-28)
|
||
---------------------
|
||
Changed high-speed setting for UMAX 3400, due to bugreport #302317.
|
||
Added disable speeup feature (as option).
|
||
Fixed CanoScan N650U settings (bugreport #302433).
|
||
|
||
V 0.50-6 (2005-10-25)
|
||
---------------------
|
||
Fixed segfault in fine calibration for CIS devices.
|
||
Tweaked LiDE25 settings (thanks to Gerd Cendelin for lending me
|
||
his LiDE25).
|
||
Let 1200DPI CIS devices use now the green-channel for gray scans.
|
||
|
||
V 0.50-5 (2005-10-21)
|
||
---------------------
|
||
Fixed high-speed feature of CanoScan D660U.
|
||
|
||
V 0.50-4 (2005-10-02)
|
||
---------------------
|
||
Updated motor settings for Canoscan LiDE25, thanks to
|
||
Stephan February <stephanf@singnet.com.sg> for providing these
|
||
values.
|
||
|
||
V 0.50-3 (2005-08-22)
|
||
---------------------
|
||
Fixed problem, when trying to scan at resolutions beyond the
|
||
optical one (sensor stops too early)
|
||
|
||
V 0.50-2 (2005-08-19)
|
||
---------------------
|
||
More cleanup.
|
||
Removed obsolete _WAF_BLACKFINE.
|
||
LiDE20 does not seem to have a reliable black calibration area,
|
||
so the devices now will switch off the lamp for dark calibration.
|
||
Fixed line statistics and added calibration data output.
|
||
|
||
V 0.50-1 (2005-08-15)
|
||
---------------------
|
||
Cleanup
|
||
Activated IPC between reader-process and parent
|
||
Added button support for Plustek/Genius devices
|
||
Did some whitespace cleanup and removed those *p typedefs
|
||
Tried to improve CIS calibration (somewhat back to 1.0.13)
|
||
Added _TWEAK_GAIN definition to allow CIS calibration increase
|
||
gain values during basic lamp setup phase
|
||
Added call to speedtest to CIS calibration
|
||
Fixed CanoScan startup problem (the way misc I/Os will be set
|
||
after power-up has done the trick)
|
||
|
||
V 0.49-8 (2005-08-08)
|
||
---------------------
|
||
Added LiDE25 settings
|
||
|
||
V 0.49-7 (2005-07-21)
|
||
---------------------
|
||
Bugfix release - fixed lampsettings for CIS calibration
|
||
|
||
V 0.49-6 (2005-07-07)
|
||
---------------------
|
||
Bugfix release - calibration and segfault :(
|
||
|
||
V 0.49-5 (2005-07-04)
|
||
---------------------
|
||
Added IPC between reader-process and parent process to
|
||
be pepared for sharing calibration info.
|
||
Added button support for backend
|
||
|
||
V 0.49-4 (2005-06-27)
|
||
---------------------
|
||
Fixed "double free" problem during sane_exit.
|
||
|
||
V 0.49-3 (2005-04-18)
|
||
---------------------
|
||
Fixed backtracking problem, when sensor-speedup is active.
|
||
|
||
V 0.49-2 (2005-01-12)
|
||
---------------------
|
||
Tweaked some device settings
|
||
Updated copyright info
|
||
Using now PhyDpi.y as selector for the motor MCLK range
|
||
|
||
V 0.49-1 (2004-11-19)
|
||
---------------------
|
||
Improved multi-device capability
|
||
|
||
V 0.48-10 (2004-10-30)
|
||
----------------------
|
||
- Fixed a bug in buffer calculation for CIS devices
|
||
|
||
V 0.48-9 (2004-10-19)
|
||
---------------------
|
||
- Use the same option names for RGB gain as umax_pp backend
|
||
|
||
V 0.48-8 (2004-10-06)
|
||
---------------------
|
||
- split scanmodes & bit-depths
|
||
|
||
V 0.48-7 (2004-10-04)
|
||
---------------------
|
||
- changed some strings according to bug #300963
|
||
|
||
V 0.48-6 (2004-09-07)
|
||
---------------------
|
||
- fixed UMAX lamp-off bug
|
||
|
||
V 0.48-4 (2004-07-26)
|
||
---------------------
|
||
- added speedup parameters for UMAX3400/3450
|
||
- added disableSpeedup option
|
||
- added UMAX3400/3450 TPA autodetection
|
||
|
||
V 0.48-3 (2004-07-16)
|
||
---------------------
|
||
- improved autowarmup feature
|
||
- improved speedup feature
|
||
|
||
V 0.48-2 (2004-07-07)
|
||
---------------------
|
||
- fixed binary mode for CanoScan D660U
|
||
|
||
V 0.48-1 (2004-07-02)
|
||
---------------------
|
||
- added more options to the frontend interface
|
||
- added UMAX 3400 with product ID 0x0050
|
||
- added support for the UMAX 3450
|
||
- added autowarmup for CFL (most CCD-scanner)
|
||
- added speedup for sensor for some devices
|
||
- fixed lamp switching problem for D660U
|
||
- fixed negative scanning lamp problem
|
||
- fixed Gray 16 mode for CanoScan D660U
|
||
- code cleanup
|
||
|
||
V 0.47-11 (2004-04-21)
|
||
----------------------
|
||
- minor fixes, esp. for MacOSX
|
||
- added lamp-off and warmup options to be configurable by backends
|
||
|
||
V 0.47-8 - 0.47-10
|
||
------------------
|
||
- never released
|
||
|
||
V 0.47-7 (2004-02-08)
|
||
---------------------
|
||
- fixed bypass calibration function for CIS devices
|
||
- added lampoff stuff to config file
|
||
|
||
V 0.47-6 (2004-01-21)
|
||
---------------------
|
||
- Cleanup work
|
||
- Changed lamp off timer for non-setitimer systems
|
||
|
||
V 0.47-5 (2004-01-09)
|
||
---------------------
|
||
- Added big-endian code to support also PPC architectures
|
||
- Added mov (model override) to support various devices using
|
||
the same product ID (namely Mustek BearPaw 1200)
|
||
- Added per-model gamma values
|
||
- Fixed a bug in the coarse CIS-lamp calibration
|
||
- Cleanup work
|
||
|
||
V 0.47-1 - 0.47-4
|
||
-----------------
|
||
- never released
|
||
|
||
V 0.46-9 (2003-11-03)
|
||
---------------------
|
||
- Added alternate calibration for CIS devices
|
||
- Added coarse calibration data-cache
|
||
- Moved parallelport code to extra backend file plustek_pp
|
||
- Fixed some minor bugs
|
||
- Fixed problem with CIS devices using FreeBSD
|
||
|
||
V 0.46-1 - 0.46-8
|
||
-----------------
|
||
- never released
|
||
|
||
V 0.45 (2003-08-05)
|
||
-------------------
|
||
- Starting this changelog
|
||
- Updates since V 0.44:
|
||
* better CIS device support
|
||
* added CanoScan N1220U, N1240U
|
||
* made CanoScan N650U and N670U work
|
||
* fixed EPSON 1260 motor killer-bug
|
||
* improved TPA scanning
|
||
* fixed TPA warmup bug on EPSON 1260/Photo
|
||
* fixed Genius device detection problem
|
||
* Added Compaq S4-100 (identical to UMAX3400)
|
||
|