kopia lustrzana https://gitlab.com/sane-project/backends
				
				
				
			
		
			
				
	
	
		
			1328 wiersze
		
	
	
		
			32 KiB
		
	
	
	
		
			C
		
	
	
			
		
		
	
	
			1328 wiersze
		
	
	
		
			32 KiB
		
	
	
	
		
			C
		
	
	
/* sane - Scanner Access Now Easy.
 | 
						|
 | 
						|
   This file (C) 1997 Ingo Schneider
 | 
						|
 | 
						|
   This file is part of the SANE package.
 | 
						|
 | 
						|
   SANE is free software; you can redistribute it and/or modify it under
 | 
						|
   the terms of the GNU General Public License as published by the Free
 | 
						|
   Software Foundation; either version 2 of the License, or (at your
 | 
						|
   option) any later version.
 | 
						|
 | 
						|
   SANE is distributed in the hope that it will be useful, but WITHOUT
 | 
						|
   ANY WARRANTY; without even the implied warranty of MERCHANTABILITY or
 | 
						|
   FITNESS FOR A PARTICULAR PURPOSE.  See the GNU General Public License
 | 
						|
   for more details.
 | 
						|
 | 
						|
   You should have received a copy of the GNU General Public License
 | 
						|
   along with sane; see the file COPYING.  If not, write to the Free
 | 
						|
   Software Foundation, Inc., 675 Mass Ave, Cambridge, MA 02139, USA.
 | 
						|
 | 
						|
   This file implements a SANE backend for Siemens 9036 flatbed scanners.  */
 | 
						|
 | 
						|
#include "sane/config.h"
 | 
						|
 | 
						|
#include <stdlib.h>
 | 
						|
#include <unistd.h>
 | 
						|
#include <string.h>
 | 
						|
#include <sys/types.h>
 | 
						|
 | 
						|
#ifndef PATH_MAX
 | 
						|
# define PATH_MAX	1024
 | 
						|
#endif
 | 
						|
 | 
						|
#include "sane/sane.h"
 | 
						|
#include "sane/sanei.h"
 | 
						|
#include "sane/sanei_config.h"
 | 
						|
#include "sane/saneopts.h"
 | 
						|
#include "sane/sanei_scsi.h"
 | 
						|
#include "s9036.h"
 | 
						|
 | 
						|
#define BACKEND_NAME	s9036
 | 
						|
#include "sane/sanei_backend.h"
 | 
						|
 | 
						|
#define MM_PER_INCH	25.4
 | 
						|
 | 
						|
#undef Byte
 | 
						|
#define Byte SANE_Byte
 | 
						|
 | 
						|
static int num_devices;
 | 
						|
static S9036_Device *s9036_devices;
 | 
						|
 | 
						|
 | 
						|
/* sets loc_s bytes long value at offset loc in scsi command to value size  */
 | 
						|
static void 
 | 
						|
set_size (Byte * loc, int loc_s, size_t size)
 | 
						|
{
 | 
						|
  int i;
 | 
						|
 | 
						|
  for (i = 0; i < loc_s; i++)
 | 
						|
    {
 | 
						|
      loc[loc_s - i - 1] = (size >> (i * 8)) & 0xff;
 | 
						|
    }
 | 
						|
}
 | 
						|
 | 
						|
static long 
 | 
						|
reserve_unit (int fd)
 | 
						|
{
 | 
						|
  const Byte scsi_reserve[] =
 | 
						|
  {
 | 
						|
    0x16, 0x00, 0x00, 0x00, 0x00, 0x00
 | 
						|
  };
 | 
						|
  DBG (3, "reserve_unit()\n");
 | 
						|
  return sanei_scsi_cmd (fd, scsi_reserve, sizeof (scsi_reserve), 0, 0);
 | 
						|
}
 | 
						|
 | 
						|
static long 
 | 
						|
release_unit (int fd)
 | 
						|
{
 | 
						|
  const Byte scsi_release[] =
 | 
						|
  {
 | 
						|
    0x17, 0x00, 0x00, 0x00, 0x00, 0x00
 | 
						|
  };
 | 
						|
  DBG (3, "release_unit()\n");
 | 
						|
  return sanei_scsi_cmd (fd, scsi_release, sizeof (scsi_release), 0, 0);
 | 
						|
}
 | 
						|
 | 
						|
static SANE_Status
 | 
						|
test_ready (int fd)
 | 
						|
{
 | 
						|
  static const Byte scsi_test_ready[] =
 | 
						|
  {
 | 
						|
    0x00, 0x00, 0x00, 0x00, 0x00, 0x00
 | 
						|
  };
 | 
						|
 | 
						|
  SANE_Status status;
 | 
						|
  int try;
 | 
						|
 | 
						|
  for (try = 0; try < 1000; ++try)
 | 
						|
    {
 | 
						|
      DBG (3, "test_ready: sending TEST_UNIT_READY\n");
 | 
						|
      status = sanei_scsi_cmd (fd, scsi_test_ready, sizeof (scsi_test_ready),
 | 
						|
			       0, 0);
 | 
						|
 | 
						|
      switch (status)
 | 
						|
	{
 | 
						|
	case SANE_STATUS_DEVICE_BUSY:
 | 
						|
	  usleep (100000);	/* retry after 100ms */
 | 
						|
	  break;
 | 
						|
 | 
						|
	case SANE_STATUS_GOOD:
 | 
						|
	  return status;
 | 
						|
 | 
						|
	default:
 | 
						|
	  DBG (1, "test_ready: test unit ready failed (%s)\n",
 | 
						|
	       sane_strstatus (status));
 | 
						|
	  return status;
 | 
						|
	}
 | 
						|
    }
 | 
						|
 | 
						|
  DBG (1, "test_ready: timed out after %d attempts\n", try);
 | 
						|
  return SANE_STATUS_IO_ERROR;
 | 
						|
}
 | 
						|
 | 
						|
static SANE_Status
 | 
						|
sense_handler (int scsi_fd, u_char *result, void *arg)
 | 
						|
{
 | 
						|
  if (result[0])
 | 
						|
    {
 | 
						|
      DBG (0, "sense_handler() : sense code = %02x\n", result[0]);
 | 
						|
      return SANE_STATUS_IO_ERROR;
 | 
						|
    }
 | 
						|
  else
 | 
						|
    {
 | 
						|
      return SANE_STATUS_GOOD;
 | 
						|
    }
 | 
						|
}
 | 
						|
 | 
						|
static SANE_Status
 | 
						|
stop_scan (int fd)
 | 
						|
{
 | 
						|
  /* XXX don't know how to stop the scanner. To be tested ! */
 | 
						|
#if 0
 | 
						|
  const Byte scsi_rewind[] =
 | 
						|
  {
 | 
						|
    0x01, 0x00, 0x00, 0x00, 0x00, 0x00
 | 
						|
  };
 | 
						|
  DBG (1, "Trying to stop scanner...\n");
 | 
						|
  return sanei_scsi_cmd (fd, scsi_rewind, sizeof (scsi_rewind), 0, 0);
 | 
						|
#else
 | 
						|
  return SANE_STATUS_GOOD;
 | 
						|
#endif
 | 
						|
}
 | 
						|
 | 
						|
 | 
						|
static SANE_Status
 | 
						|
start_scan (int fd, SANE_Bool cont)
 | 
						|
{
 | 
						|
  struct
 | 
						|
  {
 | 
						|
    /* Command */
 | 
						|
    Byte cmd;
 | 
						|
    Byte lun;
 | 
						|
    Byte res[2];
 | 
						|
    Byte tr_len;
 | 
						|
    Byte ctrl;
 | 
						|
 | 
						|
    /* Data */
 | 
						|
    Byte wid;
 | 
						|
  }
 | 
						|
  scsi_start_scan;
 | 
						|
 | 
						|
  memset (&scsi_start_scan, 0, sizeof (scsi_start_scan));
 | 
						|
  scsi_start_scan.cmd = 0x1b;
 | 
						|
  scsi_start_scan.tr_len = 1;
 | 
						|
  scsi_start_scan.wid = 0;
 | 
						|
  scsi_start_scan.ctrl = (cont == SANE_TRUE) ? 0x80 : 0x00;
 | 
						|
 | 
						|
  DBG (1, "Starting scanner ...\n");
 | 
						|
  return sanei_scsi_cmd (fd, &scsi_start_scan, sizeof (scsi_start_scan), 0, 0);
 | 
						|
}
 | 
						|
 | 
						|
static void
 | 
						|
wait_ready (int fd)
 | 
						|
{
 | 
						|
# define WAIT_READY_READ_SIZE 4
 | 
						|
  const Byte scsi_read[] =
 | 
						|
  {
 | 
						|
    0x28, 0x00,				/* opcode, lun */
 | 
						|
    0x80,				/* data type 80 == read time left */
 | 
						|
    0x00, 0x00, 0x00,			/* reserved */
 | 
						|
    0x00, 0x00, WAIT_READY_READ_SIZE,	/* transfer length */
 | 
						|
    0x00,				/* control byte */
 | 
						|
  };
 | 
						|
 | 
						|
  Byte result[WAIT_READY_READ_SIZE];
 | 
						|
  size_t size = WAIT_READY_READ_SIZE;
 | 
						|
  SANE_Status status;
 | 
						|
 | 
						|
  while (1)
 | 
						|
    {
 | 
						|
      status = sanei_scsi_cmd (fd, scsi_read, sizeof (scsi_read),
 | 
						|
			       result, &size);
 | 
						|
 | 
						|
      if (status != SANE_STATUS_GOOD || size != WAIT_READY_READ_SIZE)
 | 
						|
	{
 | 
						|
	  /*
 | 
						|
	     Command failed, the assembler code of the windows scan library
 | 
						|
	     ignores this condition, and so do I
 | 
						|
	   */
 | 
						|
	  break;
 | 
						|
	}
 | 
						|
      else
 | 
						|
	{
 | 
						|
	  /* left is the amount of seconds left till the scanner is
 | 
						|
             ready * 100 */
 | 
						|
	  int left = result[2] * 256 + result[3];
 | 
						|
 | 
						|
	  DBG (1, "wait_ready() : %d left...\n", left);
 | 
						|
 | 
						|
	  if (!left)
 | 
						|
	    break;
 | 
						|
	  /* We delay only for half the given time */
 | 
						|
	  else if (left < 200)
 | 
						|
	    usleep (left * 5000);
 | 
						|
	  else
 | 
						|
	    sleep (left / 200);
 | 
						|
	}
 | 
						|
    }
 | 
						|
 | 
						|
  return;
 | 
						|
}
 | 
						|
 | 
						|
static SANE_Status
 | 
						|
get_read_sizes (int fd, int *lines_available, int *bpl, int *total_lines)
 | 
						|
{
 | 
						|
# define GET_READ_SIZES_READ_SIZE 24
 | 
						|
 | 
						|
  const Byte scsi_read[] =
 | 
						|
  {
 | 
						|
    0x28, 0x00,				/* opcode, lun */
 | 
						|
    0x81,				/* data type 81 == read time left */
 | 
						|
    0x00, 0x00, 0x00,				/* reserved */
 | 
						|
    0x00, 0x00, GET_READ_SIZES_READ_SIZE,	/* transfer length */
 | 
						|
    0x00,				/* control byte */
 | 
						|
  };
 | 
						|
 | 
						|
  Byte result[GET_READ_SIZES_READ_SIZE];
 | 
						|
  size_t size = GET_READ_SIZES_READ_SIZE;
 | 
						|
  SANE_Status status;
 | 
						|
 | 
						|
  status = sanei_scsi_cmd (fd, scsi_read, sizeof (scsi_read), result, &size);
 | 
						|
 | 
						|
  if (status != SANE_STATUS_GOOD || size != GET_READ_SIZES_READ_SIZE)
 | 
						|
    {
 | 
						|
      /* Command failed */
 | 
						|
      return SANE_STATUS_IO_ERROR;
 | 
						|
    }
 | 
						|
  else
 | 
						|
    {
 | 
						|
      *lines_available = result[14] * 256 + result[15];
 | 
						|
      *bpl = result[12] * 256 + result[13];
 | 
						|
      if (total_lines)
 | 
						|
	*total_lines = result[10] * 256 + result[11];
 | 
						|
    }
 | 
						|
 | 
						|
  DBG (1, "get_read_sizes() : %d of %d, %d\n",
 | 
						|
       *lines_available, total_lines ? *total_lines : -1, *bpl);
 | 
						|
 | 
						|
  return SANE_STATUS_GOOD;
 | 
						|
}
 | 
						|
 | 
						|
static SANE_Status
 | 
						|
set_window (S9036_Scanner * s)
 | 
						|
/* This function sets and sends the window for scanning */
 | 
						|
{
 | 
						|
  double pixels_per_mm = (double) s->val[OPT_RESOLUTION] / MM_PER_INCH;
 | 
						|
 | 
						|
  SANE_Bool auto_bright = !(s->opt[OPT_BRIGHT_ADJUST].cap & SANE_CAP_INACTIVE);
 | 
						|
  SANE_Bool auto_contr = !(s->opt[OPT_CONTR_ADJUST].cap & SANE_CAP_INACTIVE);
 | 
						|
 | 
						|
  /* ranges down 255 (dark) down to 1(bright) */
 | 
						|
  int brightness = auto_bright ? 0 : (SANE_UNFIX (s->val[OPT_BRIGHTNESS])
 | 
						|
				      * -1.27 + 128.5);
 | 
						|
  /* ranges from 1 (little contrast) up to 255 (much contrast) */
 | 
						|
  int contrast = auto_contr ? 0 : (SANE_UNFIX (s->val[OPT_CONTRAST])
 | 
						|
				   * 1.27 + 128.5);
 | 
						|
 | 
						|
  /* ranges from 40 (dark) down to 0 (bright) */
 | 
						|
  int bright_adjust = auto_bright ? 20 - s->val[OPT_BRIGHT_ADJUST] : 0;
 | 
						|
  /* ranges from 20 (little contrast) down to -20 = 235 (much contrast) */
 | 
						|
  int contr_adjust = auto_contr ? (256 - s->val[OPT_CONTR_ADJUST]) % 256 : 0;
 | 
						|
 | 
						|
  /* Warning ! The following structur SEEMS to be an valid SCSI-2
 | 
						|
     SET_WINDOW command.  But e.g. the limits for the window are only
 | 
						|
     2 Bytes instead of 4.  The scanner was built at about 1990, so
 | 
						|
     SCSI-2 wasn't available for development...
 | 
						|
   */
 | 
						|
 | 
						|
  struct
 | 
						|
    {
 | 
						|
      Byte cmd;
 | 
						|
      Byte lun;
 | 
						|
      Byte re1[4];
 | 
						|
      Byte tr_len[3];
 | 
						|
      Byte ctrl;
 | 
						|
 | 
						|
      Byte re2[6];
 | 
						|
      Byte wd_len[2];
 | 
						|
 | 
						|
      struct
 | 
						|
	{
 | 
						|
	  Byte wid;
 | 
						|
	  Byte autobit;
 | 
						|
	  Byte x_axis_res[2];
 | 
						|
	  Byte y_axis_res[2];
 | 
						|
 | 
						|
	  Byte x_axis_ul[2];
 | 
						|
	  Byte y_axis_ul[2];
 | 
						|
 | 
						|
	  Byte wwidth[2];
 | 
						|
	  Byte wlength[2];
 | 
						|
 | 
						|
	  Byte contrast;
 | 
						|
	  Byte threshold;
 | 
						|
	  Byte brightness;
 | 
						|
 | 
						|
	  Byte image_comp;
 | 
						|
	  Byte bpp;
 | 
						|
 | 
						|
	  Byte ht_pattern;
 | 
						|
	  Byte rif_padding;
 | 
						|
	  Byte three;
 | 
						|
 | 
						|
	  Byte null1[2];
 | 
						|
	  Byte null2[8];
 | 
						|
 | 
						|
	  Byte null_eins;
 | 
						|
	  Byte eins_null;
 | 
						|
 | 
						|
	  Byte contr_adjust;
 | 
						|
	  Byte bright_adjust;
 | 
						|
 | 
						|
	  Byte null3;
 | 
						|
 | 
						|
	}
 | 
						|
      wd;
 | 
						|
 | 
						|
    }
 | 
						|
  cmd;
 | 
						|
 | 
						|
  DBG (3,
 | 
						|
       "Setting parameters: bpp %d, res %d, bri %d, con %d, bad %d, cad %d\n",
 | 
						|
       s->val[OPT_DEPTH], s->val[OPT_RESOLUTION],
 | 
						|
       brightness, contrast, bright_adjust, contr_adjust);
 | 
						|
 | 
						|
  memset (&cmd, 0, sizeof (cmd));
 | 
						|
 | 
						|
  /* Commands and sizes.  Original comment in German: Kommando und Groessen. */
 | 
						|
  cmd.cmd = 0x24;
 | 
						|
  set_size (cmd.tr_len, 3, 37 + 8);
 | 
						|
  set_size (cmd.wd_len, 2, 37);
 | 
						|
 | 
						|
  /* Resolution.  Original comment in German: Aufloesung */
 | 
						|
  set_size (cmd.wd.x_axis_res, 2, s->val[OPT_RESOLUTION]);
 | 
						|
  set_size (cmd.wd.y_axis_res, 2, s->val[OPT_RESOLUTION]);
 | 
						|
 | 
						|
  /* Scan window position/size.  Original comment in German:
 | 
						|
     Fensterposition / Groesse */
 | 
						|
  set_size (cmd.wd.x_axis_ul, 2,
 | 
						|
	    SANE_UNFIX (s->val[OPT_TL_X]) * pixels_per_mm + 0.5);
 | 
						|
  set_size (cmd.wd.y_axis_ul, 2,
 | 
						|
	    SANE_UNFIX (s->val[OPT_TL_Y]) * pixels_per_mm + 0.5);
 | 
						|
  set_size (cmd.wd.wwidth, 2, SANE_UNFIX (s->val[OPT_BR_X] - s->val[OPT_TL_X])
 | 
						|
	    * pixels_per_mm + 0.5);
 | 
						|
  set_size (cmd.wd.wlength, 2, SANE_UNFIX (s->val[OPT_BR_Y] - s->val[OPT_TL_Y])
 | 
						|
	    * pixels_per_mm + 0.5);
 | 
						|
 | 
						|
  cmd.wd.contrast = contrast;
 | 
						|
  cmd.wd.threshold = 0x00;
 | 
						|
  cmd.wd.brightness = brightness;
 | 
						|
 | 
						|
  cmd.wd.image_comp = (s->val[OPT_DEPTH] == 1) ? 0 : 2;
 | 
						|
  cmd.wd.bpp = s->val[OPT_DEPTH];
 | 
						|
 | 
						|
  cmd.wd.ht_pattern = 0;
 | 
						|
  cmd.wd.rif_padding = 0x00;
 | 
						|
  cmd.wd.three = 3;
 | 
						|
 | 
						|
  cmd.wd.null_eins = (s->val[OPT_DEPTH] == 1) ? 0 : 1;
 | 
						|
  cmd.wd.eins_null = (s->val[OPT_DEPTH] == 1) ? 1 : 0;
 | 
						|
 | 
						|
  cmd.wd.contr_adjust = contr_adjust;
 | 
						|
  cmd.wd.bright_adjust = bright_adjust;
 | 
						|
 | 
						|
  return sanei_scsi_cmd (s->fd, &cmd, sizeof (cmd), 0, 0);
 | 
						|
}
 | 
						|
 | 
						|
/* Tell scanner to scan more data.  Original comment in German:
 | 
						|
   Fordert Scanner auf, weiter zu scannen... */
 | 
						|
static SANE_Status
 | 
						|
request_more_data (S9036_Scanner * s)
 | 
						|
{
 | 
						|
  SANE_Status status;
 | 
						|
  int lines_available;
 | 
						|
  int bytes_per_line;
 | 
						|
 | 
						|
  status = start_scan (s->fd, SANE_TRUE);
 | 
						|
  if (status != SANE_STATUS_GOOD)
 | 
						|
    return status;
 | 
						|
 | 
						|
  wait_ready (s->fd);
 | 
						|
 | 
						|
  status = get_read_sizes (s->fd, &lines_available, &bytes_per_line, 0);
 | 
						|
 | 
						|
  if (!lines_available || bytes_per_line != s->params.bytes_per_line)
 | 
						|
    {
 | 
						|
      return SANE_STATUS_INVAL;
 | 
						|
    }
 | 
						|
 | 
						|
  if (s->lines_read + lines_available > s->params.lines)
 | 
						|
    return SANE_STATUS_INVAL;
 | 
						|
 | 
						|
  s->lines_in_scanner = lines_available;
 | 
						|
 | 
						|
  return SANE_STATUS_GOOD;
 | 
						|
}
 | 
						|
 | 
						|
/* May only be called when there is at least one row of data to
 | 
						|
   be read.
 | 
						|
 | 
						|
   Original comment in German: Darf nur aufgerufen werden, wenn
 | 
						|
   wirklich noch Zeilen zu scannen/lesen sind !  */
 | 
						|
static SANE_Status
 | 
						|
read_more_data (S9036_Scanner * s)
 | 
						|
{
 | 
						|
 | 
						|
  static Byte cmd[] =
 | 
						|
  {
 | 
						|
    0x28, 0x00,			/* opcode, lun */
 | 
						|
    0x00,			/* data type 80 == read time left */
 | 
						|
    0x00, 0x00, 0x00,		/* reserved */
 | 
						|
    0x00, 0x00, 0x00,		/* transfer length */
 | 
						|
    0x00,			/* control byte */
 | 
						|
  };
 | 
						|
 | 
						|
  SANE_Status status;
 | 
						|
  size_t size;
 | 
						|
  int lines_read;
 | 
						|
  int bpl = s->params.bytes_per_line;
 | 
						|
  int i;
 | 
						|
 | 
						|
  if (s->lines_in_scanner == 0)
 | 
						|
    {
 | 
						|
      /* No lines in scanner ? scan some more */
 | 
						|
      status = request_more_data (s);
 | 
						|
 | 
						|
      if (status != SANE_STATUS_GOOD)
 | 
						|
	return status;
 | 
						|
 | 
						|
    }
 | 
						|
 | 
						|
  /* We try this 3 times */
 | 
						|
  while (1)
 | 
						|
    {
 | 
						|
 | 
						|
      /* Request as much lines as would fit into the buffer ... */
 | 
						|
      lines_read = s->bufsize / bpl;
 | 
						|
 | 
						|
      /* buffer is too small for one line: we can't handle this */
 | 
						|
      if (!lines_read)
 | 
						|
	return SANE_STATUS_INVAL;
 | 
						|
 | 
						|
      /* We only request as many lines as there are already scanned */
 | 
						|
      if (lines_read > s->lines_in_scanner)
 | 
						|
	lines_read = s->lines_in_scanner;
 | 
						|
 | 
						|
      set_size (&cmd[6], 3, lines_read);
 | 
						|
      size = lines_read * s->params.bytes_per_line;
 | 
						|
 | 
						|
      DBG (1, "Requesting %d lines, in scanner: %d, total: %d\n", lines_read,
 | 
						|
	   s->lines_in_scanner, s->params.lines);
 | 
						|
 | 
						|
      status = sanei_scsi_cmd (s->fd, cmd, sizeof (cmd), s->buffer, &size);
 | 
						|
 | 
						|
      if (status != SANE_STATUS_GOOD)
 | 
						|
	{
 | 
						|
	  if (s->bufsize > 4096)
 | 
						|
	    {
 | 
						|
	      DBG (1, "sanei_scsi_cmd(): using 4k buffer\n");
 | 
						|
	      s->bufsize = 4096;
 | 
						|
	      continue;
 | 
						|
	    }
 | 
						|
 | 
						|
	  DBG (1, "sanei_scsi_cmd() = %d\n", status);
 | 
						|
	  return SANE_STATUS_IO_ERROR;
 | 
						|
	}
 | 
						|
 | 
						|
      if (size != lines_read * s->params.bytes_per_line)
 | 
						|
	{
 | 
						|
	  DBG (1, "sanei_scsi_cmd(): got %lu bytes, expected %d\n",
 | 
						|
	       (u_long) size, lines_read * s->params.bytes_per_line);
 | 
						|
	  return SANE_STATUS_INVAL;
 | 
						|
	}
 | 
						|
 | 
						|
      DBG (1, "Got %lu bytes\n", (u_long) size);
 | 
						|
      break;
 | 
						|
    }
 | 
						|
 | 
						|
 | 
						|
  /* Reverse: */
 | 
						|
  if (s->params.depth != 1)
 | 
						|
    for (i = 0; i < size; i++)
 | 
						|
      s->buffer[i] = (255 - s->buffer[i]);
 | 
						|
 | 
						|
  s->in_buffer += size;
 | 
						|
  s->lines_in_scanner -= lines_read;
 | 
						|
  s->lines_read += lines_read;
 | 
						|
 | 
						|
  return SANE_STATUS_GOOD;
 | 
						|
}
 | 
						|
 | 
						|
 | 
						|
static SANE_Status
 | 
						|
attach (const char *devname, S9036_Device ** devp)
 | 
						|
{
 | 
						|
#define ATTACH_SCSI_INQ_LEN 55
 | 
						|
  const Byte scsi_inquiry[] =
 | 
						|
  {
 | 
						|
    0x12, 0x00, 0x00, 0x00, ATTACH_SCSI_INQ_LEN, 0x00
 | 
						|
  };
 | 
						|
  Byte result[ATTACH_SCSI_INQ_LEN];
 | 
						|
 | 
						|
  int fd;
 | 
						|
  S9036_Device *dev;
 | 
						|
  SANE_Status status;
 | 
						|
  size_t size;
 | 
						|
  int i;
 | 
						|
 | 
						|
  for (dev = s9036_devices; dev; dev = dev->next)
 | 
						|
    if (strcmp (dev->sane.name, devname) == 0)
 | 
						|
      {
 | 
						|
	if (devp)
 | 
						|
	  *devp = dev;
 | 
						|
	return SANE_STATUS_GOOD;
 | 
						|
      }
 | 
						|
 | 
						|
  DBG (3, "attach: opening %s\n", devname);
 | 
						|
  status = sanei_scsi_open (devname, &fd, sense_handler, 0);
 | 
						|
  if (status != SANE_STATUS_GOOD)
 | 
						|
    {
 | 
						|
      DBG (1, "attach: open failed (%s)\n", sane_strstatus (status));
 | 
						|
      return SANE_STATUS_INVAL;
 | 
						|
    }
 | 
						|
 | 
						|
  DBG (3, "attach: sending INQUIRY\n");
 | 
						|
  size = sizeof (result);
 | 
						|
  status = sanei_scsi_cmd (fd, scsi_inquiry, sizeof (scsi_inquiry),
 | 
						|
			   result, &size);
 | 
						|
  if (status != SANE_STATUS_GOOD || size != ATTACH_SCSI_INQ_LEN)
 | 
						|
    {
 | 
						|
      DBG (1, "attach: inquiry failed (%s)\n", sane_strstatus (status));
 | 
						|
      sanei_scsi_close (fd);
 | 
						|
      return status;
 | 
						|
    }
 | 
						|
 | 
						|
  status = test_ready (fd);
 | 
						|
  sanei_scsi_close (fd);
 | 
						|
  if (status != SANE_STATUS_GOOD)
 | 
						|
    return status;
 | 
						|
 | 
						|
  /* The structure send by the scanner after inquiry is not SCSI-2
 | 
						|
     compatible.  The standard manufacturer/model fields are no ASCII
 | 
						|
     strings, but ?  At offset 36 my SIEMENS scanner identifies as an
 | 
						|
     AGFA one ?!   */
 | 
						|
 | 
						|
  if (result[0] != 6 || strncmp (result + 36, "AGFA03", 6))
 | 
						|
    {
 | 
						|
      DBG (1, "attach: device doesn't look like a Siemens 9036 scanner\n");
 | 
						|
      return SANE_STATUS_INVAL;
 | 
						|
    }
 | 
						|
 | 
						|
  DBG (3, "Inquiry data:\n");
 | 
						|
  for (i = 5; i < 55; i += 10)
 | 
						|
    DBG (3, "%02x %02x %02x %02x %02x %02x %02x %02x %02x %02x\n",
 | 
						|
      result[i], result[i + 1], result[i + 2], result[i + 3], result[i + 4],
 | 
						|
	 result[i + 5], result[i + 6], result[i + 7], result[i + 8],
 | 
						|
	 result[i + 9]);
 | 
						|
 | 
						|
  dev = malloc (sizeof (*dev));
 | 
						|
 | 
						|
  if (!dev)
 | 
						|
    return SANE_STATUS_NO_MEM;
 | 
						|
 | 
						|
  memset (dev, 0, sizeof (*dev));
 | 
						|
 | 
						|
  dev->sane.name = strdup (devname);
 | 
						|
  dev->sane.vendor = "Siemens";
 | 
						|
  dev->sane.model = "9036";
 | 
						|
  dev->sane.type = "flatbed scanner";
 | 
						|
 | 
						|
  dev->handle = 0;
 | 
						|
 | 
						|
  DBG (3, "attach: found S9036 scanner model\n");
 | 
						|
 | 
						|
  ++num_devices;
 | 
						|
  dev->next = s9036_devices;
 | 
						|
  s9036_devices = dev;
 | 
						|
 | 
						|
  if (devp)
 | 
						|
    *devp = dev;
 | 
						|
 | 
						|
  return SANE_STATUS_GOOD;
 | 
						|
}
 | 
						|
 | 
						|
static SANE_Status
 | 
						|
do_cancel (S9036_Scanner * s)
 | 
						|
{
 | 
						|
  s->scanning = SANE_FALSE;
 | 
						|
 | 
						|
  if (s->fd >= 0)
 | 
						|
    {
 | 
						|
      stop_scan (s->fd);
 | 
						|
      release_unit (s->fd);
 | 
						|
      sanei_scsi_close (s->fd);
 | 
						|
      s->fd = -1;
 | 
						|
    }
 | 
						|
 | 
						|
  if (s->buffer)
 | 
						|
    {
 | 
						|
      free (s->buffer);
 | 
						|
      s->buffer = 0;
 | 
						|
    }
 | 
						|
 | 
						|
  return SANE_STATUS_CANCELLED;
 | 
						|
}
 | 
						|
 | 
						|
 | 
						|
static SANE_Status
 | 
						|
init_options (S9036_Scanner * s)
 | 
						|
{
 | 
						|
  int i;
 | 
						|
 | 
						|
  /* Hardware Limitations: must be static ! */
 | 
						|
  static const SANE_Int depth_list[] =
 | 
						|
  {2, 1, 8};
 | 
						|
 | 
						|
  static const SANE_Int dpi_list[] =
 | 
						|
  {8, 100, 200, 300, 400, 500, 600, 700, 800};
 | 
						|
 | 
						|
  static const SANE_Range percentage_range =
 | 
						|
  {
 | 
						|
    -100 << SANE_FIXED_SCALE_SHIFT,	/* minimum */
 | 
						|
    100 << SANE_FIXED_SCALE_SHIFT,	/* maximum */
 | 
						|
    1 << SANE_FIXED_SCALE_SHIFT	/* quantization */
 | 
						|
  };
 | 
						|
 | 
						|
  static const SANE_Range automatic_adjust_range =
 | 
						|
  {-20, 20, 1};
 | 
						|
 | 
						|
  static const SANE_Range x_range =
 | 
						|
  {0, SANE_FIX (8.27 * MM_PER_INCH), 0};
 | 
						|
  static const SANE_Range y_range =
 | 
						|
  {0, SANE_FIX (12.72 * MM_PER_INCH), 0};
 | 
						|
 | 
						|
  /* ------ */
 | 
						|
 | 
						|
  memset (s->opt, 0, sizeof (s->opt));
 | 
						|
  memset (s->val, 0, sizeof (s->val));
 | 
						|
 | 
						|
  for (i = 0; i < NUM_OPTIONS; ++i)
 | 
						|
    {
 | 
						|
      s->opt[i].size = sizeof (SANE_Word);
 | 
						|
      s->opt[i].cap = SANE_CAP_SOFT_SELECT | SANE_CAP_SOFT_DETECT;
 | 
						|
    }
 | 
						|
 | 
						|
  s->opt[OPT_NUM_OPTS].title = SANE_TITLE_NUM_OPTIONS;
 | 
						|
  s->opt[OPT_NUM_OPTS].desc = SANE_DESC_NUM_OPTIONS;
 | 
						|
  s->opt[OPT_NUM_OPTS].cap = SANE_CAP_SOFT_DETECT;
 | 
						|
  s->val[OPT_NUM_OPTS] = NUM_OPTIONS;
 | 
						|
 | 
						|
  /* "Mode" group: */
 | 
						|
 | 
						|
  s->opt[OPT_MODE_GROUP].title = "Scan Mode";
 | 
						|
  s->opt[OPT_MODE_GROUP].desc = "";
 | 
						|
  s->opt[OPT_MODE_GROUP].type = SANE_TYPE_GROUP;
 | 
						|
  s->opt[OPT_MODE_GROUP].cap = 0;
 | 
						|
  s->opt[OPT_MODE_GROUP].constraint_type = SANE_CONSTRAINT_NONE;
 | 
						|
 | 
						|
  /* depth */
 | 
						|
  s->opt[OPT_DEPTH].name = SANE_NAME_BIT_DEPTH;
 | 
						|
  s->opt[OPT_DEPTH].title = SANE_TITLE_BIT_DEPTH;
 | 
						|
  s->opt[OPT_DEPTH].desc = SANE_DESC_BIT_DEPTH;
 | 
						|
  s->opt[OPT_DEPTH].type = SANE_TYPE_INT;
 | 
						|
  s->opt[OPT_DEPTH].unit = SANE_UNIT_BIT;
 | 
						|
  s->opt[OPT_DEPTH].constraint_type = SANE_CONSTRAINT_WORD_LIST;
 | 
						|
  s->opt[OPT_DEPTH].constraint.word_list = depth_list;
 | 
						|
  s->val[OPT_DEPTH] = 1;
 | 
						|
 | 
						|
  /* resolution */
 | 
						|
  s->opt[OPT_RESOLUTION].name = SANE_NAME_SCAN_RESOLUTION;
 | 
						|
  s->opt[OPT_RESOLUTION].title = SANE_TITLE_SCAN_RESOLUTION;
 | 
						|
  s->opt[OPT_RESOLUTION].desc = SANE_DESC_SCAN_RESOLUTION;
 | 
						|
  s->opt[OPT_RESOLUTION].type = SANE_TYPE_INT;
 | 
						|
  s->opt[OPT_RESOLUTION].unit = SANE_UNIT_DPI;
 | 
						|
  s->opt[OPT_RESOLUTION].constraint_type = SANE_CONSTRAINT_WORD_LIST;
 | 
						|
  s->opt[OPT_RESOLUTION].constraint.word_list = dpi_list;
 | 
						|
  s->val[OPT_RESOLUTION] = 100;
 | 
						|
 | 
						|
  /* "Geometry" group: */
 | 
						|
  s->opt[OPT_GEOMETRY_GROUP].title = "Geometry";
 | 
						|
  s->opt[OPT_GEOMETRY_GROUP].desc = "";
 | 
						|
  s->opt[OPT_GEOMETRY_GROUP].type = SANE_TYPE_GROUP;
 | 
						|
  s->opt[OPT_GEOMETRY_GROUP].cap = SANE_CAP_ADVANCED;
 | 
						|
  s->opt[OPT_GEOMETRY_GROUP].constraint_type = SANE_CONSTRAINT_NONE;
 | 
						|
 | 
						|
  /* top-left x */
 | 
						|
  s->opt[OPT_TL_X].name = SANE_NAME_SCAN_TL_X;
 | 
						|
  s->opt[OPT_TL_X].title = SANE_TITLE_SCAN_TL_X;
 | 
						|
  s->opt[OPT_TL_X].desc = SANE_DESC_SCAN_TL_X;
 | 
						|
  s->opt[OPT_TL_X].type = SANE_TYPE_FIXED;
 | 
						|
  s->opt[OPT_TL_X].unit = SANE_UNIT_MM;
 | 
						|
  s->opt[OPT_TL_X].constraint_type = SANE_CONSTRAINT_RANGE;
 | 
						|
  s->opt[OPT_TL_X].constraint.range = &x_range;
 | 
						|
  s->val[OPT_TL_X] = 0;
 | 
						|
 | 
						|
  /* top-left y */
 | 
						|
  s->opt[OPT_TL_Y].name = SANE_NAME_SCAN_TL_Y;
 | 
						|
  s->opt[OPT_TL_Y].title = SANE_TITLE_SCAN_TL_Y;
 | 
						|
  s->opt[OPT_TL_Y].desc = SANE_DESC_SCAN_TL_Y;
 | 
						|
  s->opt[OPT_TL_Y].type = SANE_TYPE_FIXED;
 | 
						|
  s->opt[OPT_TL_Y].unit = SANE_UNIT_MM;
 | 
						|
  s->opt[OPT_TL_Y].constraint_type = SANE_CONSTRAINT_RANGE;
 | 
						|
  s->opt[OPT_TL_Y].constraint.range = &y_range;
 | 
						|
  s->val[OPT_TL_Y] = 0;
 | 
						|
 | 
						|
  /* bottom-right x */
 | 
						|
  s->opt[OPT_BR_X].name = SANE_NAME_SCAN_BR_X;
 | 
						|
  s->opt[OPT_BR_X].title = SANE_TITLE_SCAN_BR_X;
 | 
						|
  s->opt[OPT_BR_X].desc = SANE_DESC_SCAN_BR_X;
 | 
						|
  s->opt[OPT_BR_X].type = SANE_TYPE_FIXED;
 | 
						|
  s->opt[OPT_BR_X].unit = SANE_UNIT_MM;
 | 
						|
  s->opt[OPT_BR_X].constraint_type = SANE_CONSTRAINT_RANGE;
 | 
						|
  s->opt[OPT_BR_X].constraint.range = &x_range;
 | 
						|
  s->val[OPT_BR_X] = x_range.max;
 | 
						|
 | 
						|
  /* bottom-right y */
 | 
						|
  s->opt[OPT_BR_Y].name = SANE_NAME_SCAN_BR_Y;
 | 
						|
  s->opt[OPT_BR_Y].title = SANE_TITLE_SCAN_BR_Y;
 | 
						|
  s->opt[OPT_BR_Y].desc = SANE_DESC_SCAN_BR_Y;
 | 
						|
  s->opt[OPT_BR_Y].type = SANE_TYPE_FIXED;
 | 
						|
  s->opt[OPT_BR_Y].unit = SANE_UNIT_MM;
 | 
						|
  s->opt[OPT_BR_Y].constraint_type = SANE_CONSTRAINT_RANGE;
 | 
						|
  s->opt[OPT_BR_Y].constraint.range = &y_range;
 | 
						|
  s->val[OPT_BR_Y] = y_range.max;
 | 
						|
 | 
						|
  /* "Enhancement" group: */
 | 
						|
  s->opt[OPT_ENHANCEMENT_GROUP].title = "Enhancement";
 | 
						|
  s->opt[OPT_ENHANCEMENT_GROUP].desc = "";
 | 
						|
  s->opt[OPT_ENHANCEMENT_GROUP].type = SANE_TYPE_GROUP;
 | 
						|
  s->opt[OPT_ENHANCEMENT_GROUP].cap = 0;
 | 
						|
  s->opt[OPT_ENHANCEMENT_GROUP].constraint_type = SANE_CONSTRAINT_NONE;
 | 
						|
 | 
						|
  /* brightness */
 | 
						|
  s->opt[OPT_BRIGHTNESS].name = SANE_NAME_BRIGHTNESS;
 | 
						|
  s->opt[OPT_BRIGHTNESS].title = SANE_TITLE_BRIGHTNESS;
 | 
						|
  s->opt[OPT_BRIGHTNESS].desc = SANE_DESC_BRIGHTNESS;
 | 
						|
  s->opt[OPT_BRIGHTNESS].type = SANE_TYPE_FIXED;
 | 
						|
  s->opt[OPT_BRIGHTNESS].cap |= SANE_CAP_AUTOMATIC;
 | 
						|
  s->opt[OPT_BRIGHTNESS].unit = SANE_UNIT_PERCENT;
 | 
						|
  s->opt[OPT_BRIGHTNESS].constraint_type = SANE_CONSTRAINT_RANGE;
 | 
						|
  s->opt[OPT_BRIGHTNESS].constraint.range = &percentage_range;
 | 
						|
  s->val[OPT_BRIGHTNESS] = 0;
 | 
						|
 | 
						|
  /* contrast */
 | 
						|
  s->opt[OPT_CONTRAST].name = SANE_NAME_CONTRAST;
 | 
						|
  s->opt[OPT_CONTRAST].title = SANE_TITLE_CONTRAST;
 | 
						|
  s->opt[OPT_CONTRAST].desc = SANE_DESC_CONTRAST;
 | 
						|
  s->opt[OPT_CONTRAST].type = SANE_TYPE_FIXED;
 | 
						|
  s->opt[OPT_CONTRAST].cap |= SANE_CAP_AUTOMATIC;
 | 
						|
  s->opt[OPT_CONTRAST].unit = SANE_UNIT_PERCENT;
 | 
						|
  s->opt[OPT_CONTRAST].constraint_type = SANE_CONSTRAINT_RANGE;
 | 
						|
  s->opt[OPT_CONTRAST].constraint.range = &percentage_range;
 | 
						|
  s->val[OPT_CONTRAST] = 0;
 | 
						|
 | 
						|
  /* brightness automatic correct */
 | 
						|
  s->opt[OPT_BRIGHT_ADJUST].name = "adjust-bright";
 | 
						|
  s->opt[OPT_BRIGHT_ADJUST].title = "Automatic brightness adjust";
 | 
						|
  s->opt[OPT_BRIGHT_ADJUST].desc = "Controls the automatic brightness of the "
 | 
						|
    "acquired image. This option is active for automatic brightness only.";
 | 
						|
  s->opt[OPT_BRIGHT_ADJUST].type = SANE_TYPE_INT;
 | 
						|
  s->opt[OPT_BRIGHT_ADJUST].cap |= SANE_CAP_INACTIVE;
 | 
						|
  s->opt[OPT_BRIGHT_ADJUST].unit = SANE_UNIT_NONE;
 | 
						|
  s->opt[OPT_BRIGHT_ADJUST].constraint_type = SANE_CONSTRAINT_RANGE;
 | 
						|
  s->opt[OPT_BRIGHT_ADJUST].constraint.range = &automatic_adjust_range;
 | 
						|
  s->val[OPT_BRIGHT_ADJUST] = 0;
 | 
						|
 | 
						|
  /* contrast automatic correct */
 | 
						|
  s->opt[OPT_CONTR_ADJUST].name = "adjust-contr";
 | 
						|
  s->opt[OPT_CONTR_ADJUST].title = "Automatic contrast adjust";
 | 
						|
  s->opt[OPT_CONTR_ADJUST].desc = "Controls the automatic contrast of the "
 | 
						|
    " acquired image. This option is active for automatic contrast only.";
 | 
						|
  s->opt[OPT_CONTR_ADJUST].type = SANE_TYPE_INT;
 | 
						|
  s->opt[OPT_CONTR_ADJUST].cap |= SANE_CAP_INACTIVE;
 | 
						|
  s->opt[OPT_CONTR_ADJUST].unit = SANE_UNIT_NONE;
 | 
						|
  s->opt[OPT_CONTR_ADJUST].constraint_type = SANE_CONSTRAINT_RANGE;
 | 
						|
  s->opt[OPT_CONTR_ADJUST].constraint.range = &automatic_adjust_range;
 | 
						|
  s->val[OPT_CONTR_ADJUST] = 0;
 | 
						|
 | 
						|
  return SANE_STATUS_GOOD;
 | 
						|
}
 | 
						|
 | 
						|
static SANE_Status
 | 
						|
attach_one (const char *dev)
 | 
						|
{
 | 
						|
  attach (dev, 0);
 | 
						|
  return SANE_STATUS_GOOD;
 | 
						|
}
 | 
						|
 | 
						|
SANE_Status
 | 
						|
sane_init (SANE_Int * version_code, SANE_Auth_Callback authorize)
 | 
						|
{
 | 
						|
  char dev_name[PATH_MAX];
 | 
						|
  size_t len;
 | 
						|
  FILE *fp;
 | 
						|
 | 
						|
  DBG_INIT ();
 | 
						|
 | 
						|
  if (version_code)
 | 
						|
    *version_code = SANE_VERSION_CODE (V_MAJOR, V_MINOR, 0);
 | 
						|
 | 
						|
  fp = sanei_config_open ("s9036.conf");
 | 
						|
  if (!fp)
 | 
						|
    {
 | 
						|
      /* default to /dev/scanner instead of insisting on config file */
 | 
						|
      attach ("/dev/scanner", 0);
 | 
						|
      return SANE_STATUS_GOOD;
 | 
						|
    }
 | 
						|
 | 
						|
  while (sanei_config_read (dev_name, sizeof (dev_name), fp))
 | 
						|
    {
 | 
						|
      if (dev_name[0] == '#')	/* ignore line comments */
 | 
						|
	continue;
 | 
						|
      len = strlen (dev_name);
 | 
						|
 | 
						|
      if (!len)
 | 
						|
	continue;		/* ignore empty lines */
 | 
						|
 | 
						|
      sanei_config_attach_matching_devices (dev_name, attach_one);
 | 
						|
    }
 | 
						|
  fclose (fp);
 | 
						|
  return SANE_STATUS_GOOD;
 | 
						|
}
 | 
						|
 | 
						|
void
 | 
						|
sane_exit (void)
 | 
						|
{
 | 
						|
  S9036_Device *dev, *next;
 | 
						|
 | 
						|
  for (dev = s9036_devices; dev; dev = next)
 | 
						|
    {
 | 
						|
      next = dev->next;
 | 
						|
      if (dev->handle)
 | 
						|
	sane_close (dev->handle);
 | 
						|
      free (dev);
 | 
						|
    }
 | 
						|
}
 | 
						|
 | 
						|
SANE_Status
 | 
						|
sane_get_devices (const SANE_Device *** device_list, SANE_Bool local_only)
 | 
						|
{
 | 
						|
  static const SANE_Device **devlist = 0;
 | 
						|
  S9036_Device *dev;
 | 
						|
  int i;
 | 
						|
 | 
						|
  if (devlist)
 | 
						|
    free (devlist);
 | 
						|
 | 
						|
  devlist = malloc ((num_devices + 1) * sizeof (devlist[0]));
 | 
						|
  if (!devlist)
 | 
						|
    return SANE_STATUS_NO_MEM;
 | 
						|
 | 
						|
  for (dev = s9036_devices, i = 0; i < num_devices; dev = dev->next)
 | 
						|
    devlist[i++] = &dev->sane;
 | 
						|
  devlist[i++] = 0;
 | 
						|
 | 
						|
  *device_list = devlist;
 | 
						|
  return SANE_STATUS_GOOD;
 | 
						|
}
 | 
						|
 | 
						|
SANE_Status
 | 
						|
sane_open (SANE_String_Const devicename, SANE_Handle * handle)
 | 
						|
{
 | 
						|
  S9036_Device *dev;
 | 
						|
  SANE_Status status;
 | 
						|
  S9036_Scanner *s;
 | 
						|
 | 
						|
  if (devicename[0])
 | 
						|
    {
 | 
						|
      status = attach (devicename, &dev);
 | 
						|
      if (status != SANE_STATUS_GOOD)
 | 
						|
	return status;
 | 
						|
    }
 | 
						|
  else
 | 
						|
    {
 | 
						|
      /* empty devicname -> use first device */
 | 
						|
      dev = s9036_devices;
 | 
						|
    }
 | 
						|
 | 
						|
  if (!dev)
 | 
						|
    return SANE_STATUS_INVAL;
 | 
						|
 | 
						|
  if (dev->handle)
 | 
						|
    return SANE_STATUS_DEVICE_BUSY;
 | 
						|
 | 
						|
  s = malloc (sizeof (*s));
 | 
						|
  if (!s)
 | 
						|
    return SANE_STATUS_NO_MEM;
 | 
						|
 | 
						|
  memset (s, 0, sizeof (*s));
 | 
						|
  s->scanning = SANE_FALSE;
 | 
						|
  s->fd = -1;
 | 
						|
  s->hw = dev;
 | 
						|
  s->hw->handle = s;
 | 
						|
 | 
						|
  init_options (s);
 | 
						|
 | 
						|
  *handle = s;
 | 
						|
  return SANE_STATUS_GOOD;
 | 
						|
}
 | 
						|
 | 
						|
void
 | 
						|
sane_close (SANE_Handle handle)
 | 
						|
{
 | 
						|
  S9036_Scanner *s = handle;
 | 
						|
 | 
						|
  if (s->scanning)
 | 
						|
    do_cancel (handle);
 | 
						|
 | 
						|
  s->hw->handle = 0;
 | 
						|
 | 
						|
  free (handle);
 | 
						|
}
 | 
						|
 | 
						|
const SANE_Option_Descriptor *
 | 
						|
sane_get_option_descriptor (SANE_Handle handle, SANE_Int option)
 | 
						|
{
 | 
						|
  S9036_Scanner *s = handle;
 | 
						|
 | 
						|
  if ((unsigned) option >= NUM_OPTIONS)
 | 
						|
    return 0;
 | 
						|
  return s->opt + option;
 | 
						|
}
 | 
						|
 | 
						|
SANE_Status
 | 
						|
sane_control_option (SANE_Handle handle, SANE_Int option,
 | 
						|
		     SANE_Action action, void *val, SANE_Int * info)
 | 
						|
{
 | 
						|
  S9036_Scanner *s = handle;
 | 
						|
  SANE_Status status;
 | 
						|
 | 
						|
  if (info)
 | 
						|
    *info = 0;
 | 
						|
 | 
						|
  if (s->scanning)
 | 
						|
    return SANE_STATUS_DEVICE_BUSY;
 | 
						|
 | 
						|
  if (option >= NUM_OPTIONS || !SANE_OPTION_IS_ACTIVE (s->opt[option].cap))
 | 
						|
    return SANE_STATUS_UNSUPPORTED;
 | 
						|
 | 
						|
  if (action == SANE_ACTION_GET_VALUE)
 | 
						|
    {
 | 
						|
 | 
						|
      switch (option)
 | 
						|
	{
 | 
						|
	case OPT_DEPTH:
 | 
						|
	case OPT_RESOLUTION:
 | 
						|
	case OPT_TL_X:
 | 
						|
	case OPT_TL_Y:
 | 
						|
	case OPT_BR_X:
 | 
						|
	case OPT_BR_Y:
 | 
						|
	case OPT_NUM_OPTS:
 | 
						|
	case OPT_BRIGHTNESS:
 | 
						|
	case OPT_CONTRAST:
 | 
						|
	case OPT_BRIGHT_ADJUST:
 | 
						|
	case OPT_CONTR_ADJUST:
 | 
						|
	  *(SANE_Word *) val = s->val[option];
 | 
						|
	  break;
 | 
						|
	default:
 | 
						|
	  return SANE_STATUS_UNSUPPORTED;
 | 
						|
	}
 | 
						|
 | 
						|
    }
 | 
						|
  else if (action == SANE_ACTION_SET_VALUE)
 | 
						|
    {
 | 
						|
 | 
						|
      if (!SANE_OPTION_IS_SETTABLE (s->opt[option].cap))
 | 
						|
	return SANE_STATUS_UNSUPPORTED;
 | 
						|
 | 
						|
      status = sanei_constrain_value (s->opt + option, val, info);
 | 
						|
      if (status != SANE_STATUS_GOOD)
 | 
						|
	return status;
 | 
						|
 | 
						|
      switch (option)
 | 
						|
	{
 | 
						|
	case OPT_DEPTH:
 | 
						|
	case OPT_RESOLUTION:
 | 
						|
	case OPT_TL_X:
 | 
						|
	case OPT_TL_Y:
 | 
						|
	case OPT_BR_X:
 | 
						|
	case OPT_BR_Y:
 | 
						|
	  if (info)
 | 
						|
	    *info |= SANE_INFO_RELOAD_PARAMS;
 | 
						|
	case OPT_BRIGHT_ADJUST:
 | 
						|
	case OPT_CONTR_ADJUST:
 | 
						|
	  s->val[option] = *(SANE_Word *) val;
 | 
						|
	  break;
 | 
						|
	case OPT_BRIGHTNESS:
 | 
						|
	  if (SANE_OPTION_IS_ACTIVE (s->opt[OPT_BRIGHT_ADJUST].cap))
 | 
						|
	    {
 | 
						|
	      s->opt[OPT_BRIGHT_ADJUST].cap |= SANE_CAP_INACTIVE;
 | 
						|
	      if (info)
 | 
						|
		*info |= SANE_INFO_RELOAD_OPTIONS;
 | 
						|
	    }
 | 
						|
	  s->val[option] = *(SANE_Word *) val;
 | 
						|
	  break;
 | 
						|
	case OPT_CONTRAST:
 | 
						|
	  if (SANE_OPTION_IS_ACTIVE (s->opt[OPT_CONTR_ADJUST].cap))
 | 
						|
	    {
 | 
						|
	      s->opt[OPT_CONTR_ADJUST].cap |= SANE_CAP_INACTIVE;
 | 
						|
	      if (info)
 | 
						|
		*info |= SANE_INFO_RELOAD_OPTIONS;
 | 
						|
	    }
 | 
						|
	  s->val[option] = *(SANE_Word *) val;
 | 
						|
	  break;
 | 
						|
	default:
 | 
						|
	  return SANE_STATUS_UNSUPPORTED;
 | 
						|
	}
 | 
						|
 | 
						|
    }
 | 
						|
  else if (action == SANE_ACTION_SET_AUTO)
 | 
						|
    {
 | 
						|
 | 
						|
      if (!SANE_OPTION_IS_SETTABLE (s->opt[option].cap))
 | 
						|
	return SANE_STATUS_UNSUPPORTED;
 | 
						|
 | 
						|
      switch (option)
 | 
						|
	{
 | 
						|
	case OPT_BRIGHTNESS:
 | 
						|
	  if (!SANE_OPTION_IS_ACTIVE (s->opt[OPT_BRIGHT_ADJUST].cap))
 | 
						|
	    {
 | 
						|
	      s->opt[OPT_BRIGHT_ADJUST].cap &= ~SANE_CAP_INACTIVE;
 | 
						|
	      if (info)
 | 
						|
		*info |= SANE_INFO_RELOAD_OPTIONS;
 | 
						|
	    }
 | 
						|
	  break;
 | 
						|
	case OPT_CONTRAST:
 | 
						|
	  if (!SANE_OPTION_IS_ACTIVE (s->opt[OPT_CONTR_ADJUST].cap))
 | 
						|
	    {
 | 
						|
	      s->opt[OPT_CONTR_ADJUST].cap &= ~SANE_CAP_INACTIVE;
 | 
						|
	      if (info)
 | 
						|
		*info |= SANE_INFO_RELOAD_OPTIONS;
 | 
						|
	    }
 | 
						|
	  break;
 | 
						|
	default:
 | 
						|
	  return SANE_STATUS_UNSUPPORTED;
 | 
						|
	}
 | 
						|
 | 
						|
    }
 | 
						|
  else
 | 
						|
    return SANE_STATUS_UNSUPPORTED;
 | 
						|
  return SANE_STATUS_GOOD;
 | 
						|
}
 | 
						|
 | 
						|
SANE_Status
 | 
						|
sane_get_parameters (SANE_Handle handle, SANE_Parameters * params)
 | 
						|
{
 | 
						|
  S9036_Scanner *s = handle;
 | 
						|
 | 
						|
  if (!s->scanning)
 | 
						|
    {
 | 
						|
      double width, height, dpi;
 | 
						|
 | 
						|
      memset (&s->params, 0, sizeof (s->params));
 | 
						|
 | 
						|
      s->params.format = SANE_FRAME_GRAY;
 | 
						|
      s->params.last_frame = SANE_TRUE;
 | 
						|
 | 
						|
      s->params.depth = s->val[OPT_DEPTH];
 | 
						|
 | 
						|
      width = SANE_UNFIX (s->val[OPT_BR_X] - s->val[OPT_TL_X]);
 | 
						|
      height = SANE_UNFIX (s->val[OPT_BR_Y] - s->val[OPT_TL_Y]);
 | 
						|
      dpi = s->val[OPT_RESOLUTION];
 | 
						|
 | 
						|
      /* make best-effort guess at what parameters will look like once
 | 
						|
         scanning starts.  */
 | 
						|
      if (dpi > 0.0 && width > 0.0 && height > 0.0)
 | 
						|
	{
 | 
						|
	  double dots_per_mm = dpi / MM_PER_INCH;
 | 
						|
 | 
						|
	  s->params.pixels_per_line = width * dots_per_mm + 0.5;
 | 
						|
	  s->params.lines = height * dots_per_mm + 0.5;
 | 
						|
	}
 | 
						|
 | 
						|
      s->params.bytes_per_line =
 | 
						|
	(s->params.pixels_per_line + (8 - s->params.depth))
 | 
						|
	/ (8 / s->params.depth);
 | 
						|
    }
 | 
						|
 | 
						|
  if (params)
 | 
						|
    *params = s->params;
 | 
						|
  return SANE_STATUS_GOOD;
 | 
						|
}
 | 
						|
 | 
						|
SANE_Status
 | 
						|
sane_start (SANE_Handle handle)
 | 
						|
{
 | 
						|
  S9036_Scanner *s = handle;
 | 
						|
  SANE_Status status;
 | 
						|
 | 
						|
  if (s->scanning)
 | 
						|
    do_cancel (s);
 | 
						|
 | 
						|
  /* First make sure we have a current parameter set.  Some of the
 | 
						|
     parameters will be overwritten below, but that's OK.  */
 | 
						|
  status = sane_get_parameters (s, 0);
 | 
						|
  if (status != SANE_STATUS_GOOD)
 | 
						|
    return status;
 | 
						|
 | 
						|
  if (s->fd < 0)
 | 
						|
    {
 | 
						|
      status = sanei_scsi_open (s->hw->sane.name, &s->fd, sense_handler, 0);
 | 
						|
      if (status != SANE_STATUS_GOOD)
 | 
						|
	{
 | 
						|
	  DBG (1, "open: open of %s failed: %s\n",
 | 
						|
	       s->hw->sane.name, sane_strstatus (status));
 | 
						|
	  s->fd = -1;
 | 
						|
	  return status;
 | 
						|
	}
 | 
						|
    }
 | 
						|
 | 
						|
  status = test_ready (s->fd);
 | 
						|
  if (status != SANE_STATUS_GOOD)
 | 
						|
    {
 | 
						|
      DBG (1, "open: test_ready() failed: %s\n", sane_strstatus (status));
 | 
						|
      sanei_scsi_close (s->fd);
 | 
						|
      s->fd = -1;
 | 
						|
      return status;
 | 
						|
    }
 | 
						|
 | 
						|
  status = reserve_unit (s->fd);
 | 
						|
  if (status != SANE_STATUS_GOOD)
 | 
						|
    {
 | 
						|
      DBG (1, "open: reserve_unit() failed: %s\n", sane_strstatus (status));
 | 
						|
      sanei_scsi_close (s->fd);
 | 
						|
      s->fd = -1;
 | 
						|
      return status;
 | 
						|
    }
 | 
						|
 | 
						|
  status = set_window (s);
 | 
						|
  if (status != SANE_STATUS_GOOD)
 | 
						|
    {
 | 
						|
      DBG (1, "open: set_window() failed: %s\n", sane_strstatus (status));
 | 
						|
      release_unit (s->fd);
 | 
						|
      sanei_scsi_close (s->fd);
 | 
						|
      s->fd = -1;
 | 
						|
      return status;
 | 
						|
    }
 | 
						|
 | 
						|
  s->scanning = SANE_TRUE;
 | 
						|
 | 
						|
  status = start_scan (s->fd, SANE_FALSE);
 | 
						|
  if (status != SANE_STATUS_GOOD)
 | 
						|
    {
 | 
						|
      DBG (1, "open: start_scan() failed: %s\n", sane_strstatus (status));
 | 
						|
      do_cancel (s);
 | 
						|
      return status;
 | 
						|
    }
 | 
						|
 | 
						|
  wait_ready (s->fd);
 | 
						|
 | 
						|
  {
 | 
						|
    int lines_available = 0, bytes_per_line = 0, total_lines = 0;
 | 
						|
 | 
						|
    status = get_read_sizes (s->fd, &lines_available, &bytes_per_line,
 | 
						|
			     &total_lines);
 | 
						|
    if (status != SANE_STATUS_GOOD)
 | 
						|
      {
 | 
						|
	DBG (1, "open: get_read_sizes() failed: %s\n",
 | 
						|
	     sane_strstatus (status));
 | 
						|
	do_cancel (s);
 | 
						|
	return status;
 | 
						|
      }
 | 
						|
 | 
						|
    if (!lines_available || !bytes_per_line || !total_lines)
 | 
						|
      {
 | 
						|
	DBG (1, "open: invalid_sizes(): %d, %d, %d\n",
 | 
						|
	     lines_available, bytes_per_line, total_lines);
 | 
						|
	do_cancel (s);
 | 
						|
	return SANE_STATUS_INVAL;
 | 
						|
      }
 | 
						|
 | 
						|
    s->params.lines = total_lines;
 | 
						|
    s->params.bytes_per_line = bytes_per_line;
 | 
						|
    s->params.pixels_per_line = bytes_per_line * (8 / s->params.depth);
 | 
						|
 | 
						|
    s->lines_in_scanner = lines_available;
 | 
						|
    s->lines_read = 0;
 | 
						|
 | 
						|
    /* Buffer must be at least 4k */
 | 
						|
    s->bufsize = (sanei_scsi_max_request_size < 4096) ?
 | 
						|
	4096 : sanei_scsi_max_request_size;
 | 
						|
 | 
						|
    s->buffer = (Byte *) malloc (s->bufsize * sizeof (Byte));
 | 
						|
 | 
						|
    if (!s->buffer)
 | 
						|
      {
 | 
						|
	DBG (1, "open  malloc(%lu) failed.\n", (u_long) s->bufsize);
 | 
						|
	do_cancel (s);
 | 
						|
	return SANE_STATUS_NO_MEM;
 | 
						|
      }
 | 
						|
    s->bufstart = s->buffer;
 | 
						|
    s->in_buffer = 0;
 | 
						|
  }
 | 
						|
 | 
						|
  return SANE_STATUS_GOOD;
 | 
						|
}
 | 
						|
 | 
						|
static void 
 | 
						|
copy_buffer (S9036_Scanner * s, SANE_Byte ** buf, SANE_Int * max_len,
 | 
						|
	     SANE_Int * len)
 | 
						|
{
 | 
						|
  if (*max_len > s->in_buffer)
 | 
						|
    {
 | 
						|
      memcpy (*buf, s->bufstart, s->in_buffer);
 | 
						|
      *buf += s->in_buffer;
 | 
						|
      *len += s->in_buffer;
 | 
						|
      *max_len -= s->in_buffer;
 | 
						|
 | 
						|
      s->bufstart = s->buffer;
 | 
						|
      s->in_buffer = 0;
 | 
						|
    }
 | 
						|
  else
 | 
						|
    {
 | 
						|
      memcpy (*buf, s->bufstart, *max_len);
 | 
						|
      s->bufstart += *max_len;
 | 
						|
      s->in_buffer -= *max_len;
 | 
						|
 | 
						|
      *buf += *max_len;
 | 
						|
      *len += *max_len;
 | 
						|
      *max_len = 0;
 | 
						|
    }
 | 
						|
}
 | 
						|
 | 
						|
 | 
						|
SANE_Status
 | 
						|
sane_read (SANE_Handle handle, SANE_Byte * buf, SANE_Int max_len,
 | 
						|
	   SANE_Int * len)
 | 
						|
{
 | 
						|
  S9036_Scanner *s = handle;
 | 
						|
  SANE_Status status;
 | 
						|
 | 
						|
  if (s->scanning != SANE_TRUE || max_len == 0)
 | 
						|
    return SANE_STATUS_INVAL;
 | 
						|
 | 
						|
  *len = 0;
 | 
						|
 | 
						|
  DBG (3, "sane_read(%d) : lines_read %d\n", max_len, s->lines_read);
 | 
						|
 | 
						|
  while (max_len > s->in_buffer && s->lines_read < s->params.lines)
 | 
						|
    {
 | 
						|
 | 
						|
      if (s->in_buffer == 0)
 | 
						|
	{
 | 
						|
	  status = read_more_data (s);
 | 
						|
 | 
						|
	  if (status != SANE_STATUS_GOOD)
 | 
						|
	    {
 | 
						|
	      DBG (1, "sane_read: read_more_data() failed (%s)\n",
 | 
						|
		   sane_strstatus (status));
 | 
						|
	      do_cancel (s);
 | 
						|
	      return status;
 | 
						|
	    }
 | 
						|
	}
 | 
						|
 | 
						|
      copy_buffer (s, &buf, &max_len, len);
 | 
						|
 | 
						|
      if (!max_len || s->lines_read >= s->params.lines)
 | 
						|
	return SANE_STATUS_GOOD;
 | 
						|
    }
 | 
						|
 | 
						|
  /* If we reached this point, there are either enough bytes in the buffer,
 | 
						|
     or, if the buffer is empty, we already reached the end of the page */
 | 
						|
 | 
						|
  if (s->in_buffer > 0)
 | 
						|
    {
 | 
						|
      copy_buffer (s, &buf, &max_len, len);
 | 
						|
      return SANE_STATUS_GOOD;
 | 
						|
    }
 | 
						|
  else
 | 
						|
    {
 | 
						|
      do_cancel (s);
 | 
						|
      DBG (1, "EOF\n");
 | 
						|
      return SANE_STATUS_EOF;
 | 
						|
    }
 | 
						|
}
 | 
						|
 | 
						|
void
 | 
						|
sane_cancel (SANE_Handle handle)
 | 
						|
{
 | 
						|
  S9036_Scanner *s = handle;
 | 
						|
  do_cancel (s);
 | 
						|
}
 | 
						|
 | 
						|
SANE_Status
 | 
						|
sane_set_io_mode (SANE_Handle handle, SANE_Bool non_blocking)
 | 
						|
{
 | 
						|
  DBG (1, "sane_set_io_mode(%d)\n", non_blocking);
 | 
						|
 | 
						|
  return (non_blocking == SANE_TRUE) ?
 | 
						|
      SANE_STATUS_UNSUPPORTED : SANE_STATUS_GOOD;
 | 
						|
}
 | 
						|
 | 
						|
SANE_Status
 | 
						|
sane_get_select_fd (SANE_Handle handle, SANE_Int * fd)
 | 
						|
{
 | 
						|
  return SANE_STATUS_UNSUPPORTED;
 | 
						|
}
 |