| .TH sane\-epson 5 "11 Jul 2008" "@PACKAGEVERSION@" "SANE Scanner Access Now Easy"
 | |
| .IX sane\-epson
 | |
| .SH NAME
 | |
| sane\-epson \- SANE backend for EPSON scanners
 | |
| .SH DESCRIPTION
 | |
| The
 | |
| .B sane\-epson
 | |
| library implements a SANE (Scanner Access Now Easy) backend that
 | |
| provides access to Epson flatbed scanners.  Some functions of this 
 | |
| backend should be considered
 | |
| .B beta-quality
 | |
| software! Most functions have been stable for a long time, but of 
 | |
| course new development can not and often times will not function properly from
 | |
| the very first day. Please report any strange behavior to the 
 | |
| maintainer of the backend.
 | |
| .PP
 | |
| At present, the following scanners are known to work with this backend:
 | |
| .PP
 | |
| .RS
 | |
| .ft CR
 | |
| .nf
 | |
| Model:                       Connection Type
 | |
| ---------------------------  -------------------
 | |
| GT-5000                      SCSI, parallel
 | |
| GT-6000                      parallel
 | |
| GT-6500                      SCSI (use only the line "scsi" in epson.conf)
 | |
| ActionScanner II             SCSI, parallel
 | |
| GT-7000                      SCSI
 | |
| Perfection 636               SCSI
 | |
| Perfection 636U              USB
 | |
| Perfection 610               USB
 | |
| Perfection 640               USB
 | |
| Perfection 1200S             SCSI
 | |
| Perfection 1200U             USB
 | |
| Perfection 1240              USB, SCSI
 | |
| Perfection 1640              USB, SCSI
 | |
| Perfection 1650              USB
 | |
| Perfection 1660              USB
 | |
| Perfection 2400              USB
 | |
| Perfection 2450              USB, IEEE-1394
 | |
| Expression 636 / GT-9500     SCSI
 | |
| Expression 1600              USB, SCSI, IEEE-1394
 | |
| Expression 1680              USB, SCSI, IEEE-1394
 | |
| CX-3200                      USB
 | |
| CX-5200                      USB
 | |
| .fi
 | |
| .ft R
 | |
| and many more. The official list is on the Sane web site.
 | |
| .RE
 | |
| 
 | |
| For other scanners the software  may or may not work.  Please send mail to 
 | |
| the backend author (khk@khk.net) to report success with scanners not on
 | |
| the list or problems with scanners that are listed. 
 | |
| .SH OPTIONS
 | |
| The options the backend supports can either be selected through command line
 | |
| options to programs like scanimage or through GUI elements in programs like
 | |
| xscanimage or xsane.
 | |
| 
 | |
| Valid command line options and their syntax can be listed by using 
 | |
| .RS
 | |
| scanimage \-\-help \-d epson
 | |
| .RE
 | |
| Not all devices support all options.
 | |
| .TP
 | |
| .I Scan Mode
 | |
| The 
 | |
| .I \-\-mode 
 | |
| switch selects the basic mode of operation of the scanner. Valid choices
 | |
| are Binary, Gray and Color.  The Binary mode is black and white only,
 | |
| Gray will produce 256 levels of gray or more depending on the scanner
 | |
| and Color means 24 bit color mode or more depending on the scanner.
 | |
| Some scanners will internally use 36 bit color, their external interface
 | |
| however may only support 24 bits.
 | |
| 
 | |
| The
 | |
| .I \-\-depth
 | |
| option selects the bit depth the scanner is using. This option is only
 | |
| available for scanners that support more than one bit depth. Older
 | |
| scanners will always transfer the image in 8bit mode. Newer scanners
 | |
| allow to select either 8 bits, 12 or 14 bits per color channel. For a
 | |
| color scan this means an effective color depth of 36 or 42 bits over
 | |
| all three channels. The valid choices depend on the scanner model.
 | |
| 
 | |
| The
 | |
| .I \-\-halftoning
 | |
| switch selects the mode that is used in Binary mode. Valid options
 | |
| are "None", "Halftone A (Hard Tone)", "Halftone B (Soft Tone)", "Halftone C
 | |
| (Net Screen)", "Dither A (4x4 Bayer)", "Dither B (4x4 Spiral)", "Dither C
 | |
| (4x4 Net Screen)", "Dither D (8x4 Net Screen)", "Text Enhanced Technology",
 | |
| "Download pattern A", and "Download pattern B".
 | |
| 
 | |
| The 
 | |
| .I \-\-dropout
 | |
| switch selects the so called dropout color. Vald options are None,
 | |
| Red, Green and Blue. The default is None. The dropout color is used for
 | |
| monochrome scanning and selects the color that is not scanned. This can
 | |
| be used to e.g. scan an original with a colored background.
 | |
| 
 | |
| The
 | |
| .I \-\-brightness
 | |
| switch controls the brightness of the scan. Valid options are integer
 | |
| values from \-3 to 3. The default is 0. The larger the brightness value,
 | |
| the brighter the image gets. If a user defined table for the gamma
 | |
| correction is selected, the brightness parameter is not available.
 | |
| 
 | |
| The
 | |
| .I \-\-sharpness
 | |
| switch sets the sharpness of the image data. Valid options are integer
 | |
| values from \-2 to 2, with \-2 meaning "Defocus", \-1 "Defocus slightly",
 | |
| 0 "Normal", 1 "Sharpen slightly" and 2 "Sharpen".
 | |
| 
 | |
| The 
 | |
| .I \-\-gamma\-correction
 | |
| switch controls the scanner's internal gamma correction. Valid options are
 | |
| "Default", "User defined", "High density printing" "Low density printing"
 | |
| and "High contrast printing".
 | |
| 
 | |
| The 
 | |
| .I \-\-color\-correction
 | |
| switch controls the scanner's internal color correction function. Valid
 | |
| options are "No Correction", "Impact\-dot printers", "Thermal printers",
 | |
| "Ink\-jet printers" and "CRT monitors". The default is "CRT monitors".
 | |
| 
 | |
| The 
 | |
| .I \-\-resolution
 | |
| switch selects the resolution for a scan. Some EPSON scanners will scan in
 | |
| any resolution between the lowest and highest possible value. The list
 | |
| reported by the scanner can be displayed using the "\-\-help \-d epson"
 | |
| parameters to scanimage.
 | |
| 
 | |
| The 
 | |
| .I \-\-mirror
 | |
| option controls the way the image is scanned. By reading the image data
 | |
| from right to left the image is mirrored. Valid options are "yes" and
 | |
| "no". The default is "no".
 | |
| 
 | |
| The 
 | |
| .I \-\-speed
 | |
| option can improve the scan speed in monochrome mode. Valid options are
 | |
| "yes" or "no", the "yes" option will speed up the scan if this option
 | |
| is supported.
 | |
| 
 | |
| The 
 | |
| .I \-\-auto\-area\-segmentation 
 | |
| switch activates the automatic area segmentation for monochrome scans. The
 | |
| scanner will try to determine which areas are text and which contain
 | |
| images. The image areas will be halftoned, and the text will be
 | |
| improved. Valid options are "yes" and "no". The default is "yes".
 | |
| 
 | |
| The 
 | |
| .I \-\-gamma\-table
 | |
| parameter can be used to download a user defined gamma table. The option
 | |
| takes 256 values from the range 0-255. In color mode this option equally
 | |
| affects the red, green, and blue channel.
 | |
| 
 | |
| The 
 | |
| .I \-\-red\-gamma\-table 
 | |
| parameter can be used to download a user defined gamma table for the
 | |
| red channel. The valid options are the same as for \-\-gamma\-table.
 | |
| 
 | |
| The 
 | |
| .I \-\-green\-gamma\-table 
 | |
| parameter can be used to download a user defined gamma table for the
 | |
| green channel. The valid options are the same as for \-\-gamma\-table.
 | |
| 
 | |
| The 
 | |
| .I \-\-blue\-gamma\-table 
 | |
| parameter can be used to download a user defined gamma table for the
 | |
| blue channel. The valid options are the same as for \-\-gamma\-table.
 | |
| 
 | |
| The color correction coefficients
 | |
| .I \-\-cct\-1 \-\-cct\-2 \-\-cct\-3 ... \-\-cct\-9
 | |
| will install color correction coefficients for the user defined color
 | |
| correction. Values are specified as integers in the range \-127..127.
 | |
| 
 | |
| The 
 | |
| .I \-\-preview
 | |
| option requests a preview scan. The frontend software automatically selects a low 
 | |
| resolution. Valid options are "yes" and "no". The default is "no".
 | |
| 
 | |
| The 
 | |
| .I \-\-preview\-speed
 | |
| options will increase the scan speed if this is supported by the
 | |
| scanner. Valid options are "yes" and "no", the default is "no".
 | |
| 
 | |
| 
 | |
| The geometry options
 | |
| .I \-l \-t \-x \-y 
 | |
| control the scan area: \-l sets the top left x coordinate, \-t the top
 | |
| left y coordinate, \-x selects the width and \-y the height of the scan
 | |
| area. All parameters are specified in millimeters.
 | |
| 
 | |
| The
 | |
| .I \-\-quick\-format
 | |
| option lets the user select a scan area with predefined sizes. Valid
 | |
| parameters are "CD", "A5 portrait", "A5 landscape", "Letter", "A4" and
 | |
| "max". The default is "max", which selects the largest possible area.
 | |
| 
 | |
| The
 | |
| .I \-\-source
 | |
| option selects the scan source. Valid options depend on the installed
 | |
| options. The default is "Flatbed".
 | |
| 
 | |
| The 
 | |
| .I \-\-auto\-eject
 | |
| option will eject a page after scanning from the document feeder. 
 | |
| 
 | |
| The
 | |
| .I \-\-film\-type
 | |
| option will select the film type for scans with the transparency
 | |
| unit. This option is only activated if the TPU is selected as scan
 | |
| source. Valid options are "Negative Film" and "Positive Film".
 | |
| 
 | |
| The
 | |
| .I \-\-focus\-position
 | |
| option selects the focus position for all scans. Valid options are "Focus
 | |
| 2.5mm above glass" and "Focus on glass". The focus on the 2.5mm point
 | |
| above the glass is necessary for scans with the transparency unit, so
 | |
| that the scanner can focus on the film if one of the film holders is used.
 | |
| This option is only functional for selected scanners, all other scanners
 | |
| will ignore this option.
 | |
| 
 | |
| 
 | |
| .SH CONFIGURATION FILE
 | |
| The configuration file @CONFIGDIR@/epson.conf specifies the device(s) that the 
 | |
| backend will use. Possible connection types are:
 | |
| .TP
 | |
| .I SCSI
 | |
| This is the default, and if nothing else is specified the backend software will
 | |
| open a given path as SCSI device. More information about valid syntax for SCSI
 | |
| devices can be found in sane\-scsi(5).
 | |
| .br
 | |
| Usually SCSI scanners are configured with a line "scsi EPSON" in this file. In 
 | |
| some cases it may be necessary to only use the string "scsi" (e.g. for the GT-6500).
 | |
| .TP
 | |
| .I PIO \- Parallel Interface
 | |
| The parallel interface can be configured in two ways: An integer value starting
 | |
| at the beginning of a line will be interpreted as the IO address of the parallel
 | |
| port. To make it clearer that a configured IO address is a parallel port the 
 | |
| port address can be preceded by the string "PIO". The PIO connection does not
 | |
| use a special device file in the /dev directory. The IO address can be specified
 | |
| in hex mode (prefixed with "0x").
 | |
| .TP
 | |
| .I USB
 | |
| A device file that is preceded by the string "USB" is treated as a scanner 
 | |
| connected via the Universal Serial Bus. The correct special device file has
 | |
| to be created prior to using it with Sane. See the USB documentation for 
 | |
| more information about how to set up the USB subsystem and the required 
 | |
| device files.
 | |
| .SH FILES
 | |
| .TP
 | |
| .I @LIBDIR@/libsane\-epson.a
 | |
| The static library implementing this backend.
 | |
| .TP
 | |
| .I @LIBDIR@/libsane\-epson.so
 | |
| The shared library implementing this backend (present on systems that
 | |
| support dynamic loading).
 | |
| .SH ENVIRONMENT
 | |
| .TP
 | |
| .B SANE_DEBUG_EPSON
 | |
| If the library was compiled with debug support enabled, this
 | |
| environment variable controls the debug level for this backend.  E.g.,
 | |
| a value of 128 requests all debug output to be printed.  Smaller
 | |
| levels reduce verbosity.
 | |
| .TP
 | |
| .B SANE_DEBUG_EPSON_SCSI
 | |
| If the library was compiled with debug support enabled, this
 | |
| environment variable controls the SCSI related debug level for this backend.  
 | |
| Only a value of 2 is supported.
 | |
| .TP
 | |
| .B SANE_EPSON_CMD_LVL
 | |
| This allows to override the function or command level that the backend 
 | |
| uses to communicate with the scanner. The function level a scanner
 | |
| supports is determined during the initialization of the device. If
 | |
| the backend does not recognize the function level reported by the 
 | |
| scanner it will default to function level B3. Valid function levels
 | |
| are A1, A2, B1, B2, B3, B4, B5, B6, B7, B8, D1 and F5. Use this feature
 | |
| only if you know what you are doing!
 | |
| 
 | |
| .SH "SEE ALSO"
 | |
| 
 | |
| sane\-scsi(5), scanimage(1), xscanimage(1), xsane(1)
 | |
| 
 | |
| .SH BUGS
 | |
| 
 | |
| None :-) At least none are currently known.
 | |
| 
 | |
| .SH UNSUPPORTED DEVICES
 | |
| The backend may be used with Epson scanners that are not yet listed 
 | |
| under the list of supported devices. A scanner that is not recognized
 | |
| may default to the function level B3, which means that not all 
 | |
| functions that the scanner may be capable of are accessible. 
 | |
| 
 | |
| If the scanner is not even recognized as an Epson scanner this is
 | |
| probably because the device name reported by the scanner is not in the
 | |
| correct format. Please send this information to the backend maintainer
 | |
| (email address is in the AUTHOR section of this man page or in the
 | |
| AUTHORS file of the SANE distribution). 
 | |
| 
 | |
| The Perfection 600, Perfection 650, Perfection 660, Perfection 1250 and 
 | |
| Perfection 1260 are not supported by this backend.
 | |
| 
 | |