| .TH sane-microtek2 5 "06 Nov 1998"
 | |
| .IX sane-microtek2
 | |
| .SH NAME
 | |
| sane-microtek2 - SANE backend for Microtek scanners with SCSI-2 command set
 | |
| .SH DESCRIPTION
 | |
| The
 | |
| .B sane-microtek2
 | |
| library implements a SANE (Scanner Access Now Easy) backend that
 | |
| provides access to some Microtek scanners with a SCSI-2 command set.
 | |
| This backend should be considered alpha.
 | |
| .PP 
 | |
| There exists a different backend for Microtek scanners with SCSI-1
 | |
| command set. Refer to sane-microtek(5) for details.
 | |
| .PP
 | |
| At present, the following
 | |
| scanners are known positively to work with this backend:
 | |
| .PP
 | |
| .RS
 | |
| Vendor     Product id:     Remark:
 | |
| .br
 | |
| --------   --------------  -----------
 | |
| .br
 | |
| Microtek   E3plus          all modes ok
 | |
| .br
 | |
| Microtek   X6              all modes ok
 | |
| .br
 | |
| Microtek   ScanMaker 330   all modes ok
 | |
| .br
 | |
| Microtek   ScanMaker 630   all modes ok
 | |
| .br
 | |
| Microtek   ScanMaker 636   all modes ok
 | |
| .br
 | |
| Microtek   Phantom 636     all modes ok
 | |
| .br
 | |
| Vobis      HighScan        all modes ok
 | |
| .RE
 | |
| .PP
 | |
| If you own a Microtek scanner with SCSI-2 interface other than the ones
 | |
| listed above, it may or may not work with SANE!
 | |
| 
 | |
| .SH "FRONTEND OPTIONS"
 | |
| This backend dynamically enables the options for the frontend,
 | |
| that are supported by the scanner in dependence of the scanning-mode
 | |
| and other options. Not supported options are disabled.
 | |
| .PP
 | |
| The following options are supported by the Microtek2-driver:
 | |
| .PP
 | |
| Color, grayscale, halftone and lineart scans.
 | |
| .PP
 | |
| Highlight, midtone, shadow, contrast, brightness, exposure time control, 
 | |
| gamma correction, threshold (dependent of the scan mode)
 | |
| .PP
 | |
| Transparency media adapter, automatic document feeder
 | |
| 
 | |
| .SH "DEVICE NAMES"
 | |
| This backend expects device names of the form:
 | |
| .PP
 | |
| .RS
 | |
| .IR special
 | |
| .RE
 | |
| .PP
 | |
| Where
 | |
| .I special
 | |
| is the UNIX path-name for the special device that corresponds to the
 | |
| scanner.  The special device name must be a generic SCSI device or a
 | |
| symlink to such a device.  Under Linux, such a device name could be
 | |
| .IR /dev/sga
 | |
| or
 | |
| .IR /dev/sge ,
 | |
| for example.
 | |
| .SH CONFIGURATION
 | |
| The configuration file for this backend resides in
 | |
| .IR @CONFIGDIR@/microtek2.conf .
 | |
| Its contents is a list of device names that correspond to Microtek
 | |
| scanners with SCSI-2 interface. Empty lines and lines starting with 
 | |
| a hash mark (#) are ignored.
 | |
| .PP
 | |
| The configuration file may also contain options. Currently two options are
 | |
| supported:
 | |
| .PP
 | |
| .RS
 | |
| option dump <n>
 | |
| .br
 | |
| option strip-height <n>
 | |
| .RE
 | |
| .PP
 | |
| If
 | |
| .I option dump <n>
 | |
| is enabled additional informations about the SCSI
 | |
| commands that are sent to the scanner are printed to stderr. This option
 | |
| is primarily useful for debugging purpose.
 | |
| .PP
 | |
| If n=1 the contents of the command blocks
 | |
| and the results for the INQUIRY and READ SCANNER ATTRIBUTES command are 
 | |
| printed to stderr.
 | |
| .PP
 | |
| If n=2 the contents of the command blocks for all other SCSI commands are
 | |
| printed to stderr, too. If n=3 the contents of the gamma table is 
 | |
| printed, too. If n=4 all scan data is additionally printed to stderr.
 | |
| .PP
 | |
| The default is n=1.
 | |
| .PP
 | |
| The
 | |
| .I option strip-height <n>
 | |
| , where <n> is a floating point number, limits the amount of data that is
 | |
| read from the scanner with one read command.
 | |
| The unit is inch and <n> defaults to 1.0,
 | |
| if this option is not set in the configuration file. If less than <n> inch
 | |
| of data fit into the SCSI buffer, then the smaller value is used and this
 | |
| option has no effect.
 | |
| .PP
 | |
| If your system has a big SCSI buffer and you want to make use of the whole
 | |
| buffer, increase the value for <n>. For example, if <n> is set to 14.0,
 | |
| no restrictions apply for scanners with a letter, legal or A4 sized
 | |
| scan area.
 | |
| .PP
 | |
| At present the options apply to all devices in the configuration file and
 | |
| cannnot be set on a per device basis.
 | |
| .PP
 | |
| A sample configuration file is shown below:
 | |
| .PP
 | |
| .RS
 | |
| option dump 1
 | |
| .br
 | |
| option strip-height 1.0
 | |
| .br
 | |
| /dev/scanner
 | |
| .br
 | |
| # this is a comment
 | |
| .br
 | |
| /dev/sge
 | |
| .RE
 | |
| 
 | |
| This backend also supports the new configuration file format which makes
 | |
| it easier to detect scanners under Linux. If you have only one scanner it
 | |
| would be best to use the configuration file for this backend, that
 | |
| is distributed with SANE. This file is shown below:
 | |
| .PP
 | |
| .RS
 | |
| option dump 1
 | |
| .br
 | |
| option strip-height 14.0
 | |
| .br
 | |
| scsi * * Scanner
 | |
| .RE
 | |
| 
 | |
| In this case all SCSI-Scanners should be detected automatically.
 | |
| 
 | |
| .SH FILES
 | |
| .TP
 | |
| .I @CONFIGDIR@/microtek2.conf
 | |
| The backend configuration file.
 | |
| .TP
 | |
| .I @LIBDIR@/libsane-microtek2.a
 | |
| The static library implementing this backend.
 | |
| .TP
 | |
| .I @LIBDIR@/libsane-microtek2.so
 | |
| The shared library implementing this backend (present on systems that
 | |
| support dynamic loading).
 | |
| .SH ENVIRONMENT
 | |
| .TP
 | |
| .B SANE_DEBUG_MICROTEK2
 | |
| If the library was compiled with debug support enabled, this
 | |
| environment variable controls the debug level for this backend.  E.g.,
 | |
| a value of 128 requests all debug output to be printed.  Smaller
 | |
| levels reduce verbosity. To see error messages on stderr set
 | |
| SANE_DEBUG_MICROTEK2 to 1 (Remark: The whole debugging levels should
 | |
| be better revised).
 | |
| .br
 | |
| E.g. just say:
 | |
| .br
 | |
| export SANE_DEBUG_MICROTEK2=128
 | |
| .SH "SEE ALSO"
 | |
| sane-scsi(5)
 | |
| .SH AUTHOR
 | |
| Bernd Schroeder
 |