| .TH sane\-ma1509 5 "13 Jul 2008" "@PACKAGEVERSION@" "SANE Scanner Access Now Easy"
 | |
| .IX sane\-ma1509
 | |
| .SH NAME
 | |
| sane\-ma1509 \- SANE backend for Mustek BearPaw 1200F USB scanner
 | |
| .SH DESCRIPTION
 | |
| The
 | |
| .B sane\-ma1509
 | |
| library implements a SANE (Scanner Access Now Easy) backend that provides
 | |
| access to the Mustek BearPaw 1200F USB flatbed scanner. This scanner is based
 | |
| on the MA-1509 chipset. Other scanners that use this chip (if they exist) may
 | |
| also work.
 | |
| .PP
 | |
| This backend is ALPHA software.  Be careful and remove the power plug
 | |
| immediately if your hear unusual noises.
 | |
| .PP
 | |
| More details can be found on the
 | |
| .B sane\-ma1509
 | |
| backend homepage
 | |
| .IR http://www.meier\-geinitz.de/sane/ma1509\-backend/ .
 | |
| .PP
 | |
| Other Mustek USB scanners are supported by the
 | |
| .BR sane\-mustek_usb (5),
 | |
| .BR sane\-gt68xx (5)
 | |
| and
 | |
| .BR sane\-plustek (5)
 | |
| backends.
 | |
| .PP
 | |
| This backend can only work with scanners that are already detected by the
 | |
| operating system. See
 | |
| .BR sane\-usb (5)
 | |
| for details.
 | |
| .PP
 | |
| If you own a scanner other than the Mustek BearPaw 1200F that works with this
 | |
| backend, please let me know this by sending the scanner's exact model name and
 | |
| the USB vendor and device ids (e.g. from
 | |
| .I /proc/bus/usb/devices
 | |
| or syslog) to me.
 | |
| 
 | |
| .SH "DEVICE NAMES"
 | |
| This backend expects device names of the form:
 | |
| .PP
 | |
| .RS
 | |
| .I special
 | |
| .RE
 | |
| .PP
 | |
| Where
 | |
| .I special
 | |
| is a path-name for the special device that corresponds to a USB scanner.
 | |
| With Linux, such a device name could be
 | |
| .I /dev/usb/scanner0
 | |
| or
 | |
| .IR libusb:001:002 ,
 | |
| for example.
 | |
| .PP
 | |
| 
 | |
| .SH CONFIGURATION
 | |
| The contents of the
 | |
| .I ma1509.conf
 | |
| file is a list of options and device names that correspond to Mustek BearPaw
 | |
| 1200F scanners.  Empty lines and lines starting with a hash mark (#) are
 | |
| ignored.
 | |
| .PP
 | |
| Instead of using the device name, the scanner can be autodetected by
 | |
| .B "usb vendor_id product_id"
 | |
| statements which are already included into
 | |
| .IR ma1509.conf .
 | |
| This is only supported with Linux 2.4.8 and higher and all systems that
 | |
| support libsub. "vendor_id" and "product_id" are hexadecimal numbers that
 | |
| identify the scanner. If this doesn't work, a device name must be placed in
 | |
| .I ma1509.conf
 | |
| as described above.
 | |
| .PP
 | |
| To set the time the lamp needs for warm-up, use
 | |
| .B option
 | |
| .B warmup-time
 | |
| in
 | |
| .IR ma1509.conf .
 | |
| The time is given in seconds after the option. The default is 30 seconds.
 | |
| .SH FILES
 | |
| .TP
 | |
| .I @CONFIGDIR@/ma1509.conf
 | |
| The backend configuration file (see also description of
 | |
| .B SANE_CONFIG_DIR
 | |
| below).
 | |
| .TP
 | |
| .I @LIBDIR@/libsane\-ma1509.a
 | |
| The static library implementing this backend.
 | |
| .TP
 | |
| .I @LIBDIR@/libsane\-ma1509.so
 | |
| The shared library implementing this backend (present on systems that
 | |
| support dynamic loading).
 | |
| .SH ENVIRONMENT
 | |
| .TP
 | |
| .B SANE_CONFIG_DIR
 | |
| This environment variable specifies the list of directories that may
 | |
| contain the configuration file.  On *NIX systems, the directories are
 | |
| separated by a colon (`:'), under OS/2, they are separated by a
 | |
| semi-colon (`;').  If this variable is not set, the configuration file
 | |
| is searched in two default directories: first, the current working
 | |
| directory (".") and then in
 | |
| .IR @CONFIGDIR@ .
 | |
| If the value of the
 | |
| environment variable ends with the directory separator character, then
 | |
| the default directories are searched after the explicitly specified
 | |
| directories.  For example, setting
 | |
| .B SANE_CONFIG_DIR
 | |
| to "/tmp/config:" would result in directories
 | |
| .IR tmp/config ,
 | |
| .IR . ,
 | |
| and
 | |
| .I "@CONFIGDIR@"
 | |
| being searched (in this order).
 | |
| .TP
 | |
| .B SANE_DEBUG_MA1509
 | |
| If the library was compiled with debug support enabled, this
 | |
| environment variable controls the debug level for this backend.  Higher
 | |
| debug levels increase the verbosity of the output.
 | |
| 
 | |
| .SH "SEE ALSO"
 | |
| .BR sane (7),
 | |
| .BR sane\-usb (5),
 | |
| .BR sane\-gt68xx (5),
 | |
| .BR sane\-plustek (5),
 | |
| .BR sane\-mustek_usb (5),
 | |
| .BR sane\-mustek (5),
 | |
| .BR sane\-mustek_pp (5),
 | |
| .br
 | |
| .I http://www.meier\-geinitz.de/sane/ma1509\-backend/
 | |
| 
 | |
| .SH AUTHOR
 | |
| Henning Meier-Geinitz
 | |
| .RI < henning@meier\-geinitz.de >
 | |
| 
 | |
| .SH BUGS
 | |
| Resolutions higher than 600 dpi don't work
 | |
| .br
 | |
| Transparency adapter and automatic document feeder is not supported yet
 | |
| .br
 | |
| No support for "high-speed" mode (jpeg)
 | |
| .PP
 | |
| More detailed bug information is available at the MA-1509 backend homepage
 | |
| .IR http://www.meier\-geinitz.de/sane/ma1509-backend/ .
 |