.TH sane-plustek 5 "10 January 2003" "@PACKAGEVERSION@" "SANE Scanner Access Now Easy"
|
|
.IX sane-plustek
|
|
.SH NAME
|
|
sane-plustek \- SANE backend for Plustek parallel port and
|
|
LM983[1/2/3] based USB flatbed scanners
|
|
.SH DESCRIPTION
|
|
The
|
|
.B sane-plustek
|
|
library implements a SANE (Scanner Access Now Easy) backend that
|
|
provides access to Plustek parallel port and USB flatbed scanners.
|
|
The USB support is part of the SANE package but for usage with
|
|
parallel port scanners you will need a kernel module, called
|
|
pt_drv which currently can be downloaded from
|
|
.br
|
|
.B http://www.gjaeger.de/scanner/plustek.html
|
|
.PP
|
|
.B !!!Please note that you need the kernel module only for
|
|
.B parallel port scanners!!!
|
|
|
|
.SH "PARALLEL PORT SUPPORT"
|
|
|
|
At present, the following scanners should work with this backend
|
|
and the corresponding kernel module:
|
|
.PP
|
|
.B "PLUSTEK SCANNERS"
|
|
.PP
|
|
Parallelport Model: ASIC: Properties:
|
|
.br
|
|
---------------------- ----- ------------------------
|
|
.br
|
|
OpticPro PT12 98003 600x1200 dpi 36bit 512Kb
|
|
.br
|
|
OpticPro P12 98003 600x1200 dpi 36bit 512Kb
|
|
.br
|
|
OpticPro 9636T/12000T 98001 600x1200 dpi 36bit 512Kb
|
|
.br
|
|
OpticPro 12000P Turbo 98001 600x1200 dpi 36bit 512Kb
|
|
.br
|
|
OpticPro 9636P+/Turbo 98001 600x1200 dpi 36bit 512Kb
|
|
.br
|
|
OpticPro 9636P 96003 600x1200 dpi 36bit 128Kb
|
|
.br
|
|
OpticPro 12000P/96000P 96003 600x1200 dpi 36bit 128Kb
|
|
.br
|
|
OpticPro 1236P 96003 600x1200 dpi 30bit 128Kb
|
|
.br
|
|
OpticPro 9600P 96003 600x1200 dpi 30bit 128Kb
|
|
.br
|
|
OpticPro 9630P/FBIV 96003 600x1200 dpi 30bit 128Kb
|
|
.br
|
|
OpticPro 9630PL (14") 96003 600x1200 dpi 30bit 128Kb
|
|
.br
|
|
OpticPro A3I 96003 400x800 dpi 36bit 128Kb
|
|
.br
|
|
OpticPro 600P/6000P 96003 300x600 dpi 30bit 32Kb
|
|
.br
|
|
OpticPro 4831P 96003 300x600 dpi 30bit 32Kb
|
|
.br
|
|
OpticPro 4830P/FBIII 96003 300x600 dpi 30bit 32Kb
|
|
.br
|
|
OpticPro 4800P/FBII 96001 300x600 dpi 24bit 32Kb
|
|
.br
|
|
.PP
|
|
|
|
.B "PRIMAX SCANNERS"
|
|
|
|
There are some scanners sold by Primax, but they are in fact
|
|
Plustek devices. These scanners are also supported.
|
|
The following table will show the relationship:
|
|
.PP
|
|
Model: Plustek Model: Remarks:
|
|
.br
|
|
--------------------------- -------------- ------------
|
|
.br
|
|
Colorado 4800 OpticPro 4800 not tested
|
|
.br
|
|
Compact 4800 Direct OpticPro 600 mov=2
|
|
.br
|
|
Compact 4800 Direct 30bit OpticPro 4830 not tested
|
|
.br
|
|
Compact 9600 Direct 30bit OpticPro 9630 works
|
|
.PP
|
|
|
|
.B "GENIUS SCANNERS"
|
|
|
|
The following devices are sold as Genius Scanners, but are in fact
|
|
Plustek devices.
|
|
The table will show the relationship:
|
|
.PP
|
|
Model: Remarks:
|
|
.br
|
|
--------------------------- ----------------------------
|
|
.br
|
|
Colorpage Vivid III V2 Like P12 but has two buttons
|
|
.br
|
|
and Wolfson DAC
|
|
.PP
|
|
|
|
.B "ARIES SCANNERS"
|
|
|
|
There's one scanner sold as Aries Scanner, but is in fact a
|
|
Plustek device.
|
|
The following table will show the relationship:
|
|
.PP
|
|
Model: Plustek Model: Remarks:
|
|
.br
|
|
--------------------------- -------------- ------------
|
|
.br
|
|
Scan-It 4800 OpticPro 600 mov=2
|
|
.PP
|
|
|
|
.B "BrightScan SCANNERS"
|
|
|
|
There's one scanner sold as BrightScan OpticPro Scanner, this is also
|
|
rebadged Plustek device.
|
|
The following table will show the relationship:
|
|
.PP
|
|
Model: Remarks:
|
|
.br
|
|
--------------------------- ----------------------------
|
|
.br
|
|
BrightScan OpticPro OpticPro P12
|
|
|
|
.SH "USB SUPPORT"
|
|
|
|
The Backend is able to support USB scanner based on the National
|
|
Semiconductor chipset LM9831, LM9832 and LM9833. The following tables
|
|
show various devices which are currently reported to work. If your
|
|
Plustek scanner has another Product ID, then the device is
|
|
.B NOT
|
|
supported, as it contains unsupported ASICs inside.
|
|
.br
|
|
|
|
Vendor Plustek - ID: 0x07B3
|
|
.br
|
|
----------------------------------------------------------
|
|
.br
|
|
USB Model: ASIC: Properties: Prod-ID
|
|
.br
|
|
----------------------------------------------------------
|
|
.br
|
|
OpticPro U12 LM9831 600x1200dpi 42bit 512Kb 0x0010
|
|
.br
|
|
OpticPro UT12 LM9831 600x1200dpi 42bit 512Kb 0x0013
|
|
.br
|
|
OpticPro UT12 LM9832 600x1200dpi 42bit 512Kb 0x0017
|
|
.br
|
|
OpticPro UT16 LM9832 600x1200dpi 42bit 512Kb 0x0017
|
|
.br
|
|
OpticPro U24 LM9831 1200x2400dpi 42bit 2Mb 0x0011
|
|
.br
|
|
OpticPro U24 LM9832 1200x2400dpi 42bit 2Mb 0x0015
|
|
.br
|
|
OpticPro UT24 LM9832 1200x2400dpi 42bit 2Mb 0x0017
|
|
.PP
|
|
|
|
Vendor KYE/Genius - ID: 0x0458
|
|
.br
|
|
----------------------------------------------------------
|
|
.br
|
|
USB Model: ASIC: Properties: Prod-ID
|
|
.br
|
|
----------------------------------------------------------
|
|
.br
|
|
Colorpage HR6 V2 LM9832 600x1200dpi 42bit 512Kb 0x2007
|
|
.br
|
|
Colorpage HR6 V2 LM9832 600x1200dpi 42bit 512Kb 0x2008
|
|
.br
|
|
Colorpage HR6A LM9832 600x1200dpi 42bit 512Kb 0x2009
|
|
.br
|
|
Colorpage HR7 LM9832 600x1200dpi 42bit 512Kb 0x2013
|
|
.br
|
|
Colorpage HR7LE LM9832 600x1200dpi 42bit 512Kb 0x2015
|
|
.br
|
|
Colorpage HR6X LM9832 600x1200dpi 42bit 512Kb 0x2016
|
|
.PP
|
|
|
|
Vendor Hewlett-Packard - ID: 0x03F0
|
|
.br
|
|
----------------------------------------------------------
|
|
.br
|
|
USB Model: ASIC: Properties: Prod-ID
|
|
.br
|
|
----------------------------------------------------------
|
|
.br
|
|
ScanJet 2100C LM9831 600x1200dpi 42bit 512Kb 0x0505
|
|
.br
|
|
ScanJet 2200C LM9832 600x1200dpi 42bit 512Kb 0x0605
|
|
.PP
|
|
|
|
Vendor Mustek - ID: 0x0400
|
|
.br
|
|
----------------------------------------------------------
|
|
.br
|
|
USB Model: ASIC: Properties: Prod-ID
|
|
.br
|
|
----------------------------------------------------------
|
|
.br
|
|
BearPaw 1200 LM9831 600x1200dpi 42bit 512Kb 0x1000
|
|
.br
|
|
BearPaw 2400 LM9832 1200x2400dpi 42bit 2Mb 0x1001
|
|
.PP
|
|
|
|
Vendor UMAX - ID: 0x1606
|
|
.br
|
|
----------------------------------------------------------
|
|
.br
|
|
USB Model: ASIC: Properties: Prod-ID
|
|
.br
|
|
----------------------------------------------------------
|
|
.br
|
|
UMAX 3400/2420 LM9832 600x1200dpi 42bit 512Kb 0x0060
|
|
.br
|
|
UMAX 5400 LM9832 1200x2400dpi 42bit 512Kb 0x0160
|
|
.PP
|
|
|
|
Vendor Epson - ID: 0x04B8
|
|
.br
|
|
----------------------------------------------------------
|
|
.br
|
|
USB Model: ASIC: Properties: Prod-ID
|
|
.br
|
|
----------------------------------------------------------
|
|
.br
|
|
Perfection 1250 LM9832 1200x2400dpi 42bit 512Kb 0x010F
|
|
.br
|
|
Perfection 1260 LM9832 1200x2400dpi 42bit 512Kb 0x011D
|
|
.PP
|
|
|
|
Vendor CANON - ID: 0x04A9
|
|
.br
|
|
----------------------------------------------------------
|
|
.br
|
|
USB Model: ASIC: Properties: Prod-ID
|
|
.br
|
|
----------------------------------------------------------
|
|
.br
|
|
CanoScan N650/656U LM9832 600x1200dpi 42bit 512Kb 0x2206
|
|
.br
|
|
CanoScan N1220U LM9832 1200x2400dpi 42bit 512Kb 0x2207
|
|
.br
|
|
CanoScan N670/676U LM9833 600x1200dpi 48bit 512Kb 0x220D
|
|
.br
|
|
CanoScan N1240U LM9833 1200x2400dpi 48bit 512Kb 0x220E
|
|
.br
|
|
CanoScan LIDE20 LM9833 600x1200dpi 48bit 512Kb 0x220D
|
|
.br
|
|
CanoScan LIDE30 LM9833 1200x2400dpi 48bit 512Kb 0x220E
|
|
.PP
|
|
|
|
.SH "OTHER PLUSTEK SCANNERS"
|
|
|
|
The SCSI scanner OpticPro 19200S is a rebadged Artec AM12S scanner
|
|
and is supported by the
|
|
.B Artec
|
|
backend.
|
|
.br
|
|
Only the National Semiconductor LM9831/2 based devices of Plustek
|
|
are supported by this driver. Older versions of the U12, the UT12,
|
|
the U1212 and U1248 (GrandTech chipset are not supported)
|
|
.PP
|
|
|
|
.SH "DEVICE NAMES"
|
|
This backend expects a default device called:
|
|
.PP
|
|
.RS
|
|
.I /dev/pt_drv
|
|
.RE
|
|
.PP
|
|
This default device will be used, if no configuration
|
|
file can be found.
|
|
.PP
|
|
The device-driver is currently not part of the SANE distribution.
|
|
It has to be downloaded from:
|
|
.br
|
|
.B http://www.gjaeger.de/scanner/plustek.html
|
|
.br
|
|
See the INSTALL file there for a proper setup. Currently only Linux
|
|
is supported by this driver (Kernel 2.2.x and higher).
|
|
.PP
|
|
As the backend and the driver support up to four devices
|
|
per system, it is possible to specify them in the configuration
|
|
file
|
|
.PP
|
|
.RS
|
|
.I @CONFIGDIR@/plustek.conf
|
|
.RE
|
|
.PP
|
|
See the plustek.conf file for examples.
|
|
.PP
|
|
|
|
.SH "CONFIGURATION"
|
|
.PP
|
|
The configuration of this backend can be divided into two sections:
|
|
.br
|
|
.PP
|
|
.B "CONFIGURATION - parallel port scanner"
|
|
.PP
|
|
.br
|
|
.B "CONFIGURATION - USB scanner"
|
|
.PP
|
|
.br
|
|
Please make sure, that the configuration matches the real world,
|
|
namely your configuration. And note again, .I pt_drv is only needed
|
|
.PP
|
|
|
|
.SH "CONFIGURATION - PARALLEL PORT SCANNER"
|
|
.PP
|
|
Beside the kernel-module options, which are described below, you
|
|
need to enable the parallel port device in the configuration file
|
|
.PP
|
|
.RS
|
|
.I @CONFIGDIR@/plustek.conf
|
|
.RE
|
|
.PP
|
|
For a proper setup, you will need at least two entries:
|
|
|
|
.TP
|
|
.I [parport]
|
|
.TP
|
|
.I device /dev/pt_drv
|
|
.PP
|
|
.I parport
|
|
tells the backend, that the following devicename (here
|
|
.I /dev/pt_drv
|
|
) has to be interpreted as parallel port scanner device.
|
|
.PP
|
|
To have this device, you will need to setup the kernel module.
|
|
As the driver is a loadable kernel module, it is configured
|
|
by invoking insmod with the appropriate parameters or
|
|
appending the options to the file
|
|
.B /etc/conf.modules
|
|
.PP
|
|
.B
|
|
The Options:
|
|
.br
|
|
lampoff=lll
|
|
.RS
|
|
The value
|
|
.I lll
|
|
tells the driver, after how many seconds to
|
|
switch-off the lamp(s). The default value is 180.
|
|
0 will disable this feature.
|
|
.br
|
|
.B HINT:
|
|
Do not use a value that is too small, because often
|
|
switching on/off the lamps will reduce their lifetime.
|
|
.RE
|
|
.PP
|
|
port=ppp
|
|
.RS
|
|
.I ppp
|
|
specifies the port base address, where the scanner
|
|
is connected to. The default value is 0x378 which
|
|
normaly is standard.
|
|
.RE
|
|
.PP
|
|
warmup=www
|
|
.RS
|
|
.I www
|
|
specifies the time in seconds, how long a lamp has to be on,
|
|
until the driver will start to scan. The default value is 30.
|
|
.RE
|
|
.PP
|
|
lOffonEnd=e
|
|
.RS
|
|
.I e
|
|
specifies the behaviour when unloading the driver, 1 --> switch
|
|
lamps off, 0 --> do not change lamp status
|
|
.RE
|
|
.PP
|
|
slowIO=s
|
|
.RS
|
|
.I s
|
|
specifies which I/O functions the driver should use, 1 --> use
|
|
delayed functions, 0 --> use the non-delayed ones
|
|
.RE
|
|
.PP
|
|
forceMode=fm
|
|
.RS
|
|
.I fm
|
|
specifies port mode which should be used, 0 --> autodetection,
|
|
1 --> use SPP mode and 2 --> use EPP mode
|
|
.RE
|
|
.PP
|
|
mov=m
|
|
.RS
|
|
.I m
|
|
=0 - default: no override
|
|
.br
|
|
.I m
|
|
=1 - OpticPro 9630PL override (works if OP9630
|
|
.br
|
|
has been detected) forces legal size (14")
|
|
.br
|
|
.I m
|
|
=2 - Primax 4800Direct override (works if OP600
|
|
.br
|
|
has been detected) swaps red/green color
|
|
.br
|
|
.I m
|
|
=3 - OpticPro 9636 override (works if OP9636 has
|
|
.br
|
|
been detected) disables backends
|
|
.br
|
|
transparency/negativ capabilities
|
|
.br
|
|
.I m
|
|
=4 - OpticPro 9636P override (works if OP9636 has
|
|
.br
|
|
been detected) disables backends
|
|
.br
|
|
transparency/negativ capabilities
|
|
.br
|
|
.I m
|
|
=5 - OpticPro A3I override (works if OP12000 has
|
|
.br
|
|
been detected) enables A3 scanning
|
|
.br
|
|
.I m
|
|
=6 - OpticPro 4800P override (works if OP600
|
|
.br
|
|
has been detected) swaps red/green color
|
|
.br
|
|
.RE
|
|
.PP
|
|
Sample entry for file
|
|
.B "/etc/modules.conf"
|
|
:
|
|
.br
|
|
.I alias char-major-40 pt_drv
|
|
.br
|
|
.I pre-install pt_drv modprobe -k parport
|
|
.br
|
|
.I options pt_drv lampoff=180 warmup=15 port=0x378 lOffonEnd=0 mov=0 slowIO=0 forceMode=0
|
|
.PP
|
|
For multidevice support, simply add values separated by commas to
|
|
the different options
|
|
.br
|
|
.I options pt_drv port=0x378,0x278 mov=0,4 slowIO=0,1 forceMode=0,1
|
|
.PP
|
|
Remember to call depmod after changing /etc/conf.modules.
|
|
.PP
|
|
.B "PARALLEL PORT MODES"
|
|
.PP
|
|
The current driver works best, when the parallel port
|
|
has been set to EPP-mode. When detecting any other
|
|
mode such as ECP or PS/2 the driver tries to set to a
|
|
faster, supported mode. If this fails, it will use the
|
|
SPP mode, as this mode should work with all Linux supported
|
|
parallel ports.
|
|
.PP
|
|
Former Plustek scanner models (4830, 9630) supplied a
|
|
ISA parallel port adapter card. This card is
|
|
.BR not
|
|
supported by the driver.
|
|
.PP
|
|
The ASIC 96001/3 based models have sometimes trouble with
|
|
high resolution modes. If you encounter sporadic corrupted
|
|
images (parts duplicated or shifted horizontally) kill all
|
|
other applications before scanning and (if sufficient
|
|
memory available) disable swapping.
|
|
.PP
|
|
|
|
.SH "CONFIGURATION - USB SCANNER"
|
|
.PP
|
|
To use the USB device with this backend, you need at least
|
|
two entries in the configuration file
|
|
.br
|
|
.I @CONFIGDIR@/plustek.conf
|
|
.TP
|
|
.I [usb] vendor-id product-id
|
|
.TP
|
|
.I device /dev/usbscanner
|
|
.PP
|
|
.I usb
|
|
tells the backend, that the following devicename (here
|
|
.I /dev/usbscanner
|
|
) has to be interpreted as USB scanner device. If vendor- and
|
|
product-id has not been specified, the backend tries to
|
|
detect this by its own. If device ist set to
|
|
.I auto
|
|
then the next matching device is used.
|
|
.PP
|
|
.B
|
|
The Options:
|
|
.PP
|
|
option warmup t
|
|
.RS
|
|
.I t
|
|
specifies the warmup period in seconds
|
|
.RE
|
|
.PP
|
|
option lampOff t
|
|
.RS
|
|
.I t
|
|
is the time in seconds for switching off the lamps in
|
|
standby mode
|
|
.RE
|
|
.PP
|
|
option lOffonEnd b
|
|
.RS
|
|
.I b
|
|
specifies the behaviour when closing the backend, 1 --> switch
|
|
lamps off, 0 --> do not change lamp status
|
|
.RE
|
|
.PP
|
|
option invertNegatives b
|
|
.RS
|
|
.I b
|
|
0 --> do not invert the picture during negativ scans,
|
|
1 --> invert picture
|
|
.RE
|
|
.PP
|
|
option skipCalibration b
|
|
.RS
|
|
.I b
|
|
0 --> perform calibration,
|
|
1 --> skip calibration (only non Plustek devices)
|
|
.RE
|
|
.PP
|
|
option enableTPA b
|
|
.RS
|
|
.I b
|
|
0 --> default behaviour, specified by the internal tables,
|
|
1 --> override internal tables and allow TPA mode (EPSON only)
|
|
.RE
|
|
|
|
.PP
|
|
option posOffX x
|
|
.br
|
|
option posOffY y
|
|
.br
|
|
option tpaOffX x
|
|
.br
|
|
option tpaOffY y
|
|
.br
|
|
option negOffX x
|
|
.br
|
|
option negOffY y
|
|
.RS
|
|
.I x y
|
|
By using this settings, the user can adjust the given image
|
|
positions.
|
|
.B Please note, that there's no internal range checking for
|
|
.B this feature.
|
|
.RE
|
|
.PP
|
|
option posShadingY p
|
|
.br
|
|
option tpaShadingY p
|
|
.br
|
|
option negShadingY p
|
|
.RS
|
|
.I p
|
|
overrides the internal shading position. The values are in steps.
|
|
.B Please note, that there's no internal range checking for
|
|
.B this feature.
|
|
.RE
|
|
.PP
|
|
option redGamma r
|
|
.br
|
|
option greenGamma g
|
|
.br
|
|
option blueGamma b
|
|
.br
|
|
option grayGamma gr
|
|
.RS
|
|
.I r g b gr
|
|
.RE
|
|
By using these values, the internal linear gamma table (r,g,b,gr = 1.0)
|
|
can be adjusted.
|
|
.PP
|
|
option red_gain r
|
|
.br
|
|
option green_gain g
|
|
.br
|
|
option blue_gain b
|
|
.RS
|
|
.I r g b
|
|
These values can be used to adjust the internally detected gain values of
|
|
the AFE for each channel. The range is between 0 and 63.
|
|
.RE
|
|
|
|
|
|
|
|
|
|
|
|
.PP
|
|
See the plustek.conf file for examples.
|
|
.PP
|
|
.B Note:
|
|
.br
|
|
You have to make sure, that the USB subsystem is loaded
|
|
correctly and the module
|
|
.I scanner
|
|
has been loaded too. To make this module recognize your
|
|
scanner, you might have to add the following line to
|
|
your
|
|
.B "/etc/modules.conf"
|
|
:
|
|
.br
|
|
.I options scanner vendor=0x7b3 product=0x17
|
|
.PP
|
|
.br
|
|
If you're not sure about the vendor and product id of your
|
|
device, simply load the USB subsystem and plug in your
|
|
scanner. Then do a
|
|
.I cat /proc/bus/usb/devices
|
|
and look for the scanner.
|
|
.PP
|
|
|
|
.SH FILES
|
|
.TP
|
|
.I @CONFIGDIR@/plustek.conf
|
|
The backend configuration file
|
|
.TP
|
|
.I @LIBDIR@/libsane-plustek.a
|
|
The static library implementing this backend.
|
|
.TP
|
|
.I @LIBDIR@/libsane-plustek.so
|
|
The shared library implementing this backend (present on systems that
|
|
support dynamic loading).
|
|
.TP
|
|
.I /lib/modules/<Kernel-Version>/misc/pt_drv.o
|
|
The Linux Kernelmodule.
|
|
.PP
|
|
|
|
.SH "CONTACT AND BUG-REPORTS"
|
|
.PP
|
|
Please send any information and bug-reports to:
|
|
.br
|
|
.B Plustek Driver Mailing List <plustek@linuxhacker.org>
|
|
.br
|
|
or directly to:
|
|
.br
|
|
.B Gerhard Jaeger <gerhard@gjaeger.de>
|
|
.PP
|
|
Additional info and hints can be obtained from our
|
|
.br
|
|
Mailing-List archive at:
|
|
.br
|
|
.B http://www.linuxhacker.org/cgi-bin/ezmlm-cgi/3
|
|
.PP
|
|
or directly from the projects' homepage at:
|
|
.br
|
|
.B http://www.gjaeger.de/scanner/plustek.html
|
|
.PP
|
|
|
|
.SH "KNOWN BUGS & RESTRICTIONS"
|
|
.PP
|
|
.br
|
|
* The Halftoning works, but the quality is poor
|
|
.br
|
|
* Printers (especially HP models) will start to
|
|
.br
|
|
print during scanning. This in fact is a problem
|
|
.br
|
|
to other printers too, using bidirectional protocol
|
|
.br
|
|
(see www.plustek.com (TAIWAN) page for further details)
|
|
.br
|
|
* The driver does not support these manic scalings up
|
|
.br
|
|
to 16 times the physical resolution. The only scaling
|
|
.br
|
|
is done on resolutions between the physical resolution
|
|
.br
|
|
of the CDD-sensor and the stepper motor i.e. you have a
|
|
.br
|
|
600x1200 dpi scanner and you are scanning using 800dpi,
|
|
.br
|
|
so scaling is necesary, because the sensor only delivers
|
|
.br
|
|
600dpi but the motor is capable to perform 800dpi steps.
|
|
.br
|
|
* On some devices, the pictures seems to be bluished
|
|
.PP
|
|
ASIC 98001 based models:
|
|
.br
|
|
* The 300dpi transparency and negative mode does not work
|
|
.br
|
|
correctly.
|
|
.br
|
|
* There is currently no way to distinguish a model with
|
|
.br
|
|
and without transpareny unit.
|
|
.br
|
|
* The scanned images seem to be too dark (P9636T)
|
|
.PP
|
|
ASIC 96003/1 based models:
|
|
.br
|
|
* 30bit mode is currently not supported.
|
|
.br
|
|
* On low-end systems and under heavy system load, the
|
|
.br
|
|
driver will loosing data, this might causes the sensor
|
|
.br
|
|
to hit the scan-bed and/or the picture is corrupted.
|
|
.br
|
|
* The scanspeed on 600x1200 dpi models is slow.
|
|
.br
|
|
* The scanquality of the A3I is poor
|
|
.br
|
|
.PP
|
|
USB models:
|
|
.br
|
|
* Plusteks' model policy is somewhat inconsistent. This
|
|
.br
|
|
means, they sell technical different devices under the
|
|
.br
|
|
same product name. Therefore it is possible that some
|
|
.br
|
|
devices like the UT12 or U12 won't work - please check
|
|
.br
|
|
the model list above and compare the product-id to
|
|
.br
|
|
the one your device has.
|
|
.br
|
|
* Negative scanning quality is poor.
|