kopia lustrzana https://gitlab.com/sane-project/backends
71 wiersze
2.4 KiB
Plaintext
71 wiersze
2.4 KiB
Plaintext
Fri Dec 5 18:10:52 PST 1997
|
|
Geoffrey T. Dairiki <dairiki@alumni.caltech.edu>
|
|
|
|
Here is a new HP backend. It's name is, appropriately, ``newhp''.
|
|
|
|
It is still in the pre-alpha stages but mostly works on my ScanJet 5P.
|
|
It is completely untested on other scanners, but might hopefully work
|
|
on ScanJet models IIp, IIc, IIcx, 3p, 3c, 4c, 4p, and 5p.
|
|
|
|
I've only really tested this with xscanimage.
|
|
|
|
Some features included in this backend which aren't in the old
|
|
HP driver are:
|
|
|
|
Support for custom tonemaps (gamma-maps). For some reason I
|
|
can't get the 10-bit tonemaps working with my 5p, so for you
|
|
only get a single tonemap (it still works in color mode, but
|
|
you don't get individual control over each R/G/B channel.)
|
|
|
|
You can enable the scanjets "Auto Threshold" mode when scanning
|
|
line-art. I can't notice that it does much though....
|
|
|
|
Added an option to control the scan speed.
|
|
|
|
Added an option to select the dither pattern used in half-tone mode.
|
|
I don't think that custom dither patterns are working correctly,
|
|
and in any case, with the current front-ends, there is no convenient
|
|
way to set a custom dither pattern....
|
|
|
|
Added an option to select the color correction matrixes.
|
|
This also seems to be flaky. Again the current front-ends do not provide
|
|
a decent way to adjust the custom color matrix.
|
|
|
|
|
|
Tue Feb 24 20:00:00 UT+1 1998
|
|
Peter Kirchgessner <pkirchg@aol.com>
|
|
|
|
Picked up the sources because they did not find their way to the
|
|
SANE-package up to now. And because I want to have a better support
|
|
for the HP Photosmart Photoscanner. Renamed the backend from newhp
|
|
to xhp just to get a better acceptance.
|
|
|
|
Added an option to perform calibration. Upload and download calibration data
|
|
|
|
Added options for horizontal/vertical mirroring. Vertical mirroring
|
|
is performed by loading image completely into memory before
|
|
sending to frontend.
|
|
|
|
Uses SCSI-flushing more often because otherwise the scanner did not
|
|
accept all of the commands.
|
|
|
|
Test support of commands to be independant from inquired
|
|
model number.
|
|
|
|
Wed Mar 28 10:00:00 UT+1 1998
|
|
|
|
Bring it on its way to the SANE-project. Geoffrey accepted to add
|
|
licence informations to the files as long as noone has to pay for the code.
|
|
|
|
Sun Jun 07 15:00:00 UT+1 1998
|
|
|
|
Added unload button
|
|
|
|
Fixed problem with custom gamma table
|
|
|
|
Sat Nov 14 14:00:00 UT+1 1998
|
|
|
|
Show calibrate button on Photosmart only for print media
|
|
Add HP 6200 C
|
|
Suppress halftone mode on photosmart (it is not supported)
|