| .TH sane\-hs2p 5 "13 Jul 2008" "@PACKAGEVERSION@" "SANE Scanner Access Now Easy"
 | |
| .IX sane\-hs2p
 | |
| .SH NAME
 | |
| sane\-hs2p \- SANE backend for Ricoh SCSI flatbed/ADF scanners
 | |
| .SH DESCRIPTION
 | |
| The
 | |
| .B sane\-hs2p
 | |
| library implements a SANE (Scanner Access Now Easy) backend that provides
 | |
| access to the Ricoh IS450 family of scanners. Should also work with the IS420,
 | |
| IS410, and IS430 scanners, but these are untested.
 | |
| Please contact the maintainer or the sane\-devel mailing list if you own such a scanner.
 | |
| .PP
 | |
| This backend is alpha-quality. It may have bugs and some scanners haven't been
 | |
| tested at all. Be careful and pull the plug if the scanner causes unusual
 | |
| noise.
 | |
| 
 | |
| .SH "DEVICE NAMES"
 | |
| This backend expects device names of the form:
 | |
| .PP
 | |
| .RS
 | |
| .I special
 | |
| .RE
 | |
| .PP
 | |
| Where
 | |
| .I special
 | |
| is the path-name for the special device that corresponds to a SCSI
 | |
| scanner. The program
 | |
| .BR sane\-find\-scanner (1)
 | |
| helps to find out the correct device. Under Linux, such a device name could be
 | |
| .I /dev/sg0
 | |
| or
 | |
| .IR /dev/sga ,
 | |
| for example.  See
 | |
| .BR sane\-scsi (5)
 | |
| for details.
 | |
| 
 | |
| .SH CONFIGURATION
 | |
| The contents of the
 | |
| .I hs2p.conf
 | |
| file is a list of device names that correspond to SCSI
 | |
| scanners.  Empty lines and lines starting with a hash mark (#) are
 | |
| ignored.  See
 | |
| .BR sane\-scsi (5)
 | |
| on details of what constitutes a valid device name.
 | |
| 
 | |
| .SH FILES
 | |
| .TP
 | |
| .I @CONFIGDIR@/hs2p.conf
 | |
| The backend configuration file (see also description of
 | |
| .B SANE_CONFIG_DIR
 | |
| below).
 | |
| .TP
 | |
| .I @LIBDIR@/libsane\-hs2p.a
 | |
| The static library implementing this backend.
 | |
| .TP
 | |
| .I @LIBDIR@/libsane\-hs2p.so
 | |
| The shared library implementing this backend (present on systems that
 | |
| support dynamic loading).
 | |
| .SH ENVIRONMENT
 | |
| .TP
 | |
| .B SANE_CONFIG_DIR
 | |
| This environment variable specifies the list of directories that may
 | |
| contain the configuration file.  On *NIX systems, the directories are
 | |
| separated by a colon (`:'), under OS/2, they are separated by a
 | |
| semi-colon (`;').  If this variable is not set, the configuration file
 | |
| is searched in two default directories: first, the current working
 | |
| directory (".") and then in
 | |
| .IR @CONFIGDIR@ .
 | |
| If the value of the
 | |
| environment variable ends with the directory separator character, then
 | |
| the default directories are searched after the explicitly specified
 | |
| directories.  For example, setting
 | |
| .B SANE_CONFIG_DIR
 | |
| to "/tmp/config:" would result in directories
 | |
| .IR tmp/config ,
 | |
| .IR . ,
 | |
| and
 | |
| .I "@CONFIGDIR@"
 | |
| being searched (in this order).
 | |
| .TP
 | |
| .B SANE_DEBUG_HS2P
 | |
| If the library was compiled with debug support enabled, this
 | |
| environment variable controls the debug level for this backend.
 | |
| A value of 255 prints all debug output.  Smaller values reduce verbosity.
 | |
| 
 | |
| .SH CURRENT STATUS
 | |
| The
 | |
| .B sane\-hs2p
 | |
| backend is now in version 1.00. All major scanning-related features
 | |
| are supported, except for those features requiring the optional IPU. Scanning
 | |
| from the flatbed or ADF (either simplex or duplex) is supported. Lineart,
 | |
| halftone, 4-bit gray, and 8-bit gray are supported. Pre-set gamma tables and
 | |
| halftone patterns are supported, as well as brightness, threshold, contrast.
 | |
| Also supported is scan wait mode, binary and gray filtering, negative scanning,
 | |
| and absolute or relative white setting. Printing with the optional endorser
 | |
| also is supported.
 | |
| 
 | |
| .SH PLANNED FUNCTIONALITY
 | |
| This scanner can scan from the ADF in continuous simplex mode.
 | |
| Surprisingly, many scanners scan an entire document from the ADF
 | |
| into memory before ejecting the sheet. Thus if the document is too
 | |
| long, the scanner cannot hold the entire image data in memory.
 | |
| But if the scanner would send its image data when its memory got full,
 | |
| and then read the next buffer's worth of data, continuous scanning
 | |
| could be achieved.
 | |
| 
 | |
| .SH MISSING FUNCTIONALITY
 | |
| The SCSI commands for uploading (2AH) or downloading (28H)
 | |
| custom halftone patterns (02H) and gamma vectors (03H) should work,
 | |
| but require implementing the SANE Option-Value code to allow the
 | |
| user to create the tables to be uploaded to the scanner. No support
 | |
| for Maintenance Data (80H) is planned as this functionality is more
 | |
| suited to a stand-alone utility to be used by a technician when
 | |
| replacing the lamp or ADF unit. Nor is support for reading or changing
 | |
| IPU (93H) parameters and adjustments planned, since my IS450 lacks
 | |
| such a unit. The 31-byte Auto Photo/Letter struct and 21-byte Dynamic
 | |
| threshold struct are documented in the
 | |
| .I hs2p-scsi.h
 | |
| file should someone wish to use their IPU for image data processing.
 | |
| 
 | |
| .SH "SEE ALSO"
 | |
| .BR sane (7),
 | |
| .BR sane\-find\-scanner (1),
 | |
| .BR sane\-scsi (5),
 | |
| 
 | |
| .SH AUTHOR
 | |
| jeremy
 | |
| .RI < jeremy@acjlaw.net >
 | |
| .br
 | |
| Maintained by Jeremy Johnson
 | |
| .RI < jeremy@acjlaw.net >
 |