.TH sane\-mustek_pp 5 "13 Jul 2008"
 | 
						|
.de EX
 | 
						|
.sp
 | 
						|
.nf
 | 
						|
.ft CW
 | 
						|
..
 | 
						|
.de EE
 | 
						|
.ft R
 | 
						|
.fi
 | 
						|
.sp
 | 
						|
..
 | 
						|
.IX sane\-mustek_pp
 | 
						|
.SH NAME
 | 
						|
sane\-mustek_pp \- SANE backend for Mustek parallel port flatbed scanners
 | 
						|
.SH DESCRIPTION
 | 
						|
The
 | 
						|
.B sane\-mustek_pp
 | 
						|
library implements a SANE (Scanner Access Now Easy) backend that
 | 
						|
provides access to Mustek parallel port flatbed scanners and OEM versions.
 | 
						|
 | 
						|
There are 2 classes of Mustek parallel port scanners: regular 
 | 
						|
.B CCD
 | 
						|
(cold cathode device) scanners and 
 | 
						|
.B CIS 
 | 
						|
(contact image sensor) scanners.
 | 
						|
.P
 | 
						|
The current version of this backend supports both CCD type scanners and
 | 
						|
CIS type scanners.
 | 
						|
.P
 | 
						|
The following scanners might work with this backend:
 | 
						|
 | 
						|
.SS "CCD scanners" 
 | 
						|
 | 
						|
.EX
 | 
						|
Model:                  ASIC ID:        CCD Type:       works:
 | 
						|
--------------------------------------------------------------
 | 
						|
SE 6000 P               1013            00              yes
 | 
						|
SM 4800 P               1013/1015       04/01           yes
 | 
						|
SE 1200 ED Plus         1015            01              no
 | 
						|
SM 1200 ED Plus         1015            01              no
 | 
						|
SE 12000 P              1505            05              no
 | 
						|
600 III EP Plus         1013/1015       00/01           yes
 | 
						|
SE 600 SEP              1013            ??              yes
 | 
						|
600 II EP               ????            ??              no
 | 
						|
MD9848                  1015            00              yes
 | 
						|
Gallery 4800            ????            ??              yes
 | 
						|
Viviscan Compact II     1013            00              yes
 | 
						|
.EE
 | 
						|
.SS CIS scanners
 | 
						|
.EX
 | 
						|
Model:                  ASIC ID:        works:
 | 
						|
-----------------------------------------------
 | 
						|
Mustek 600 CP & 96 CP   1015            yes (*)
 | 
						|
Mustek 1200 CP          1015            yes
 | 
						|
Mustek 1200 CP+         1015            yes
 | 
						|
.EE
 | 
						|
 | 
						|
.EX
 | 
						|
OEM versions            Original        works 
 | 
						|
--------------------------------------------------
 | 
						|
Medion/LifeTec/Tevion
 | 
						|
   MD/LT 9350/9351      1200 CP         yes
 | 
						|
   MD/LT 9850/9851      1200 CP         maybe (**)
 | 
						|
   MD/LT 9858           1200 CP         probably
 | 
						|
   MD/LT 9890/9891      1200 CP         yes
 | 
						|
Targa 
 | 
						|
   Funline TS12EP       1200 CP         yes
 | 
						|
   Funline TS6EP        600 CP          yes
 | 
						|
Trust
 | 
						|
   Easy Connect 9600+   600 CP          yes
 | 
						|
Cybercom 
 | 
						|
   9352                 1200 CP         yes (***)
 | 
						|
.EE
 | 
						|
.HP 
 | 
						|
(*)    Calibration  problems existed with earlier version of
 | 
						|
this driver. They seem to be solved now.
 | 
						|
.HP 
 | 
						|
(**)   Problems have been reported in the past for the
 | 
						|
MD/LT9850 type (striped scans, head moving in wrong
 | 
						|
direction at some resolutions). It is not known whether
 | 
						|
the current version of the driver still has these problems.
 | 
						|
.PP
 | 
						|
.B  IF YOU HEAR LOUD CLICKING NOISES, IMMEDIATELY UNPLUG THE SCANNER !
 | 
						|
(This holds for any type of scanner).
 | 
						|
.HP 
 | 
						|
(***)  Possibly, the engine_delay parameter has to be set to 1 ms
 | 
						|
for accurate engine movements.
 | 
						|
.PP
 | 
						|
Please note that this backend is still under construction. Certain models
 | 
						|
are currently not supported and some may never be because the communication
 | 
						|
protocol is still unknown (eg., SE 12000 P).
 | 
						|
.PP
 | 
						|
Some scanners work faster when 
 | 
						|
.B EPP/ECP
 | 
						|
is enabled in the BIOS. EPP mode however may lead to hard-locks on some Linux
 | 
						|
systems. If that is the case for you, you can either disable ECP/EPP in your
 | 
						|
BIOS or disable it in the backend itself (see GLOBAL OPTIONS).
 | 
						|
.PP
 | 
						|
Note that the backend needs to run as root or has to have appropriate access
 | 
						|
rights to /dev/parport* if libieee1284 support is compiled in. To allow user 
 | 
						|
access to the scanner run the backend through the network interface (See 
 | 
						|
saned(8) and sane\-net(5)). Note also that the backend
 | 
						|
.I does not
 | 
						|
support
 | 
						|
.IR "parport sharing" ,
 | 
						|
i.e. if you try printing while scanning, your computer may crash. To enable
 | 
						|
parport sharing, you have to enable libieee1284 at compile time. This backend
 | 
						|
also conflicts with the
 | 
						|
.I sane\-musteka4s2
 | 
						|
backend. You can only enable one of them in your dll.conf. However, you have
 | 
						|
to enable the backend explicitly in your dll.conf, just remove the hash mark
 | 
						|
in the line "mustek_pp".
 | 
						|
 | 
						|
.SH "DEVICE DEFINITION"
 | 
						|
This backend allows multiple devices being defined and configured via the 
 | 
						|
.B mustek_pp.conf
 | 
						|
file (even simultaneously, provided that they are connected to different
 | 
						|
parallel ports). Please make sure to edit this file
 | 
						|
.B before
 | 
						|
you use the backend.
 | 
						|
.PP
 | 
						|
A device can be defined as follows:
 | 
						|
.PP
 | 
						|
.RS
 | 
						|
.I scanner <name> <port name> <driver>
 | 
						|
.RE
 | 
						|
.PP
 | 
						|
where
 | 
						|
.HP
 | 
						|
.B <name>
 | 
						|
is an arbitrary name for the device, optionally enclosed by double quotes,
 | 
						|
for instance "LifeTec 9350".
 | 
						|
.HP
 | 
						|
.B <port name>
 | 
						|
is the name of the parallel port to which the device is connected. In case
 | 
						|
libieee1284 is used for communication with the port
 | 
						|
.I (default 
 | 
						|
.IR setup) , 
 | 
						|
valid port names are 
 | 
						|
.BR parport0 , 
 | 
						|
.BR parport1 , 
 | 
						|
and
 | 
						|
.BR parport2 .
 | 
						|
.PP
 | 
						|
In case the backend is configured for raw IO
 | 
						|
.I (old 
 | 
						|
.IR setup) ,
 | 
						|
port addresses have to be used instead of port names:
 | 
						|
.BR 0x378 ,
 | 
						|
.BR 0x278 , 
 | 
						|
or
 | 
						|
.BR 0x3BC .
 | 
						|
The mapping of parallel ports (lp0, lp1, and lp2) to these addresses 
 | 
						|
can be different for different Linux kernel versions. For instance,
 | 
						|
if you are using a Kernel 2.2.x or better and you have only one
 | 
						|
parallel port, this port is named lp0 regardless of the base address. However,
 | 
						|
this backend requires the base address of your port. If you are not sure which
 | 
						|
port your scanner is connected to, have a look at your /etc/conf.modules,
 | 
						|
/etc/modules.conf and/or /proc/ioports.
 | 
						|
.PP
 | 
						|
If you are unsure which port to use, you can use the magic value
 | 
						|
.BR * 
 | 
						|
to probe for your scanner.
 | 
						|
.PP
 | 
						|
.HP
 | 
						|
.B <driver>
 | 
						|
is the driver to use for this device. Currently available drivers are:
 | 
						|
.IP
 | 
						|
.BR cis600 "   : for 600 CP, 96 CP & OEM versions"
 | 
						|
.br
 | 
						|
.BR cis1200 "  : for 1200 CP & OEM versions"
 | 
						|
.br  
 | 
						|
.BR cis1200+ " : for 1200 CP+ & OEM versions"
 | 
						|
.br
 | 
						|
.BR ccd300 "   : for 600 IIIE P & OEM version"
 | 
						|
.IP
 | 
						|
.B Choosing  the  wrong  driver  can  damage  your scanner!
 | 
						|
.br
 | 
						|
Especially, using the 1200CP settings on a 600CP can be
 | 
						|
harmful. If the scanner starts making a loud noise, turn
 | 
						|
it off immediately !!!
 | 
						|
.PP
 | 
						|
Using the cis600 driver on a 1200CP or a 1200CP+ is probably not
 | 
						|
dangerous. The cis1200+ driver also works for the 1200CP, and using
 | 
						|
the cis1200 driver on a 1200CP+ will typically result in scans that
 | 
						|
cover only half of the width of the scan area (also not dangerous).
 | 
						|
.PP
 | 
						|
If unsure about the exact model of your OEM version, check the optical
 | 
						|
resolution in the manual or on the box: the 600CP has a maximum optical
 | 
						|
resolution of 300x600 DPI, whereas the 1200CP and 1200CP+ have a maximum 
 | 
						|
optical resolution of 600x1200 DPI. 
 | 
						|
.PP
 | 
						|
Examples:
 | 
						|
.PP
 | 
						|
.RS 
 | 
						|
scanner "LifeTec 9350" 0x378 cis1200
 | 
						|
.PP
 | 
						|
scanner Mustek_600CP 0x378 cis600
 | 
						|
.PP
 | 
						|
scanner Mustek_600IIIEP * ccd300
 | 
						|
.RE
 | 
						|
 | 
						|
If in doubt which port you have to use, or whether your scanner is
 | 
						|
detected at all, you can use 
 | 
						|
.B sane\-find\-scanner \-p
 | 
						|
to probe all configured ports.
 | 
						|
 | 
						|
.SH CONFIGURATION
 | 
						|
.PP
 | 
						|
The contents of the
 | 
						|
.B mustek_pp.conf
 | 
						|
file is a list of device definitions and device options that correspond to 
 | 
						|
Mustek scanners.  Empty lines and lines starting with a hash mark (#) are
 | 
						|
ignored. Options have the following format:
 | 
						|
.PP
 | 
						|
.RS
 | 
						|
.I option <name> [<value>]
 | 
						|
.RE
 | 
						|
.PP
 | 
						|
Depending on the nature of the option, a value may or may not be present.
 | 
						|
Options always apply to the scanner definition that precedes them. There
 | 
						|
are no global options. Options are also driver-specific: not all drivers
 | 
						|
support all possible options. 
 | 
						|
 | 
						|
.SS Common options
 | 
						|
.TP
 | 
						|
.B bw <value>
 | 
						|
Black/white discrimination value to be used during lineart scanning. Pixel
 | 
						|
values below this value are assumed to be black, values above are
 | 
						|
assumed to be white. 
 | 
						|
.br
 | 
						|
Default value: 127
 | 
						|
.br 
 | 
						|
Minimum:         0
 | 
						|
.br 
 | 
						|
Maximum:       255
 | 
						|
.sp
 | 
						|
Example:  option bw 150
 | 
						|
 | 
						|
.SS CIS driver options
 | 
						|
.TP
 | 
						|
.B top_adjust <value>
 | 
						|
Vertical adjustment of the origin, expressed in millimeter (floating point). 
 | 
						|
This option can be used to calibrate the position of the origin, within
 | 
						|
certain limits. Note that CIS scanners are probably temperature sensitive, and
 | 
						|
that a certain inaccuracy may be hard to avoid. Differences in offset between
 | 
						|
runs in the order of 1 to 2 mm are not unusual.
 | 
						|
.br
 | 
						|
Default value: 0.0
 | 
						|
.br
 | 
						|
Minimum:      \-5.0
 | 
						|
.br
 | 
						|
Maximum:       5.0
 | 
						|
.br
 | 
						|
.sp
 | 
						|
Example:  option top_adjust \-2.5
 | 
						|
.TP
 | 
						|
.B slow_skip
 | 
						|
Turns fast skipping to the start of the scan region off. When the region to
 | 
						|
scan does not start at the origin, the driver will try to move the scanhead
 | 
						|
to the start of the scan area at the fastest possible speed. On some models,
 | 
						|
this may not work, resulting in large inaccuracies (up to centimeters).
 | 
						|
By setting this option, the driver is forced to use normal speed during
 | 
						|
skipping, which can circumvent the accuracy problems. Currently, there are 
 | 
						|
no models for which these inaccuracy problems are known to occur.
 | 
						|
.sp
 | 
						|
By default, fast skipping is used.
 | 
						|
.sp
 | 
						|
Example:  option slow_skip
 | 
						|
.TP
 | 
						|
.B engine_delay <value>
 | 
						|
Under normal circumstances, it is sufficient for the driver to wait for the
 | 
						|
scanner signaling that the engine is stable, before a new engine command can
 | 
						|
be transmitted. In rare cases, certain scanners and/or parallel port chipsets
 | 
						|
appear to prevent reliable detection of the engine state. As a result, engine
 | 
						|
commands are transmitted too soon and the movement of the scanner head becomes
 | 
						|
unreliable. Inaccuracies ranging up to 10 cm over the whole vertical scan
 | 
						|
range have been reported. To work around this problem, the engine_delay option
 | 
						|
can be set. If it is set, the driver waits an additional amount of time after
 | 
						|
every engine command, equal to the engine_delay parameter, expressed in
 | 
						|
milliseconds. It practice an engine_delay of 1 ms is usually sufficient. The
 | 
						|
maximum delay is 100 ms.
 | 
						|
.sp
 | 
						|
Note that every additional ms of delay can add up to 14 seconds to the total
 | 
						|
scanning time (highest resolution), so an as small as possible value is
 | 
						|
preferred.
 | 
						|
.sp
 | 
						|
Default value:   0
 | 
						|
.br
 | 
						|
Minimum:         0
 | 
						|
.br
 | 
						|
Maximum:       100
 | 
						|
.sp
 | 
						|
Example:  option engine_delay 1
 | 
						|
 | 
						|
.SS CCD driver options
 | 
						|
.TP
 | 
						|
.B top <value>
 | 
						|
Number of scanlines to skip to the start of the scan area. The number can
 | 
						|
be any positive integer. Values known to me are 47 and 56.
 | 
						|
.sp
 | 
						|
Default value: 47
 | 
						|
.br
 | 
						|
Minimum:       0
 | 
						|
.br
 | 
						|
Maximum:       none
 | 
						|
.br
 | 
						|
.sp
 | 
						|
Example:  option top 56
 | 
						|
.TP
 | 
						|
.B waitbank <value>
 | 
						|
The number of usecs to wait for a bank change. You should not touch this
 | 
						|
value actually. May be any positive integer
 | 
						|
.sp
 | 
						|
Default value: 700
 | 
						|
.br
 | 
						|
Minimum:       0
 | 
						|
.br
 | 
						|
Maximum:       none
 | 
						|
.sp
 | 
						|
Example:  option waitbank 700
 | 
						|
.PP
 | 
						|
A sample configuration file is shown below:
 | 
						|
.PP
 | 
						|
.EX
 | 
						|
#
 | 
						|
# LifeTec/Medion 9350 on port 0x378
 | 
						|
#
 | 
						|
scanner "LifeTec 9350" 0x378 cis1200
 | 
						|
 | 
						|
# Some calibration options (examples!).
 | 
						|
option bw 127
 | 
						|
option top_skip \-0.8
 | 
						|
 | 
						|
#
 | 
						|
# A Mustek 600CP on port 0x3BC
 | 
						|
#
 | 
						|
scanner "Mustek 600CP" 0x3BC cis600
 | 
						|
 | 
						|
# Some calibration options (examples!).
 | 
						|
option bw 120
 | 
						|
option top_skip 1.2
 | 
						|
 | 
						|
#
 | 
						|
# A Mustek 1200CP+ on port 0x278
 | 
						|
#
 | 
						|
scanner "Mustek 1200CP plus" 0x278 cis1200+
 | 
						|
 | 
						|
# Some calibration options (examples!).
 | 
						|
option bw 130
 | 
						|
option top_skip 0.2
 | 
						|
 | 
						|
#
 | 
						|
# A Mustek 600 III EPP on port parport0
 | 
						|
#
 | 
						|
scanner "Mustek 600 III EPP" parport0 ccd300
 | 
						|
 | 
						|
# Some calibration options (examples!).
 | 
						|
option bw 130
 | 
						|
option top 56
 | 
						|
.EE
 | 
						|
 | 
						|
.SH GLOBAL OPTIONS
 | 
						|
.PP
 | 
						|
You can control the overall behaviour of the mustek_pp backend by global
 | 
						|
options which precede any scanner definition in the mustek_pp.conf file.
 | 
						|
.sp
 | 
						|
Currently, there is only one global option:
 | 
						|
 | 
						|
.SS Global options
 | 
						|
.TP
 | 
						|
.B no_epp
 | 
						|
Disable parallel port mode EPP: works around a known bug in the Linux parport
 | 
						|
code. Enable this option, if the backend hangs when trying to access the
 | 
						|
parallel port in EPP mode.
 | 
						|
.sp
 | 
						|
Default value: use EPP
 | 
						|
.sp
 | 
						|
Example:  option no_epp
 | 
						|
 | 
						|
.SH FILES
 | 
						|
.TP
 | 
						|
.I @CONFIGDIR@/mustek_pp.conf
 | 
						|
The backend configuration file (see also description of
 | 
						|
.B SANE_CONFIG_DIR
 | 
						|
below).
 | 
						|
.TP
 | 
						|
.I @LIBDIR@/libsane\-mustek_pp.a
 | 
						|
The static library implementing this backend.
 | 
						|
.TP
 | 
						|
.I @LIBDIR@/libsane\-mustek_pp.so
 | 
						|
The shared library implementing this backend (present on systems that
 | 
						|
support dynamic loading).
 | 
						|
 | 
						|
.SH ENVIRONMENT
 | 
						|
.TP
 | 
						|
.B SANE_CONFIG_DIR
 | 
						|
This environment variable specifies the list of directories that may
 | 
						|
contain the configuration file.  Under UNIX, the directories are
 | 
						|
separated by a colon (`:'), under OS/2, they are separated by a
 | 
						|
semi-colon (`;').  If this variable is not set, the configuration file
 | 
						|
is searched in two default directories: first, the current working
 | 
						|
directory (".") and then in @CONFIGDIR@.  If the value of the
 | 
						|
environment variable ends with the directory separator character, then
 | 
						|
the default directories are searched after the explicitly specified
 | 
						|
directories.  For example, setting
 | 
						|
.B SANE_CONFIG_DIR
 | 
						|
to "/tmp/config:" would result in directories "tmp/config", ".", and
 | 
						|
"@CONFIGDIR@" being searched (in this order).
 | 
						|
.TP
 | 
						|
.B SANE_DEBUG_MUSTEK_PP
 | 
						|
If the library was compiled with debug support enabled, this
 | 
						|
environment variable controls the debug level for this backend.  E.g.,
 | 
						|
a value of 128 requests all debug output to be printed.  Smaller
 | 
						|
levels reduce verbosity.
 | 
						|
.EX
 | 
						|
level   debug output
 | 
						|
--------------------------------------
 | 
						|
 0      nothing
 | 
						|
 1      errors
 | 
						|
 2      warnings & minor errors
 | 
						|
 3      additional information
 | 
						|
 4      debug information
 | 
						|
 5      code flow (not supported yet)
 | 
						|
 6      special debug information
 | 
						|
.EE
 | 
						|
.TP
 | 
						|
.B SANE_DEBUG_SANEI_PA4S2
 | 
						|
This variable sets the debug level for the SANE interface for the Mustek
 | 
						|
chipset A4S2. Note that enabling this will spam your terminal with some
 | 
						|
million lines of debug output.
 | 
						|
.EX
 | 
						|
level   debug output
 | 
						|
----------------------------
 | 
						|
 0      nothing
 | 
						|
 1      errors
 | 
						|
 2      warnings
 | 
						|
 3      things nice to know
 | 
						|
 4      code flow
 | 
						|
 5      detailed code flow
 | 
						|
 6      everything
 | 
						|
.EE
 | 
						|
 | 
						|
.SH "SEE ALSO"
 | 
						|
sane(7), sane\-mustek(5), sane\-net(5), saned(8), sane\-find\-scanner(1)
 | 
						|
 | 
						|
.TP
 | 
						|
For latest bug fixes and information see
 | 
						|
.I http://www.penguin\-breeder.org/sane/mustek_pp/
 | 
						|
 | 
						|
.TP
 | 
						|
For additional information on the CIS driver, see
 | 
						|
.I http://home.scarlet.be/eddy_de_greef/
 | 
						|
 | 
						|
.SH AUTHORS
 | 
						|
.nf
 | 
						|
Jochen Eisinger <jochen at penguin\-breeder dot org> 
 | 
						|
Eddy De Greef <eddy_de_greef at scarlet dot be>
 | 
						|
.fi
 | 
						|
 | 
						|
.SH BUGS
 | 
						|
Too many... please send bug reports to 
 | 
						|
.I sane\-devel@lists.alioth.debian.org
 | 
						|
(note that you have to subscribe first to the list before you can send
 | 
						|
emails... see http://www.sane\-project.org/mailing\-lists.html)
 | 
						|
 | 
						|
.SH BUG REPORTS
 | 
						|
If something doesn't work, please contact us (Jochen for the CCD scanners,
 | 
						|
Eddy for the CIS scanners). But we need some information about
 | 
						|
your scanner to be able to help you...
 | 
						|
 | 
						|
.TP
 | 
						|
.I SANE version
 | 
						|
run "scanimage \-V" to determine this
 | 
						|
.TP
 | 
						|
.I the backend version and your scanner hardware
 | 
						|
run "SANE_DEBUG_MUSTEK_PP=128 scanimage \-L" as root. If you don't get any output
 | 
						|
from the mustek_pp backend, make sure a line "mustek_pp" is included into
 | 
						|
your @CONFIGDIR@/dll.conf.
 | 
						|
If your scanner isn't detected, make sure you've defined the right port address
 | 
						|
in your mustek_pp.conf.
 | 
						|
.TP
 | 
						|
.I the name of your scanner/vendor
 | 
						|
also a worthy information. Please also include the optical resolution and lamp type of your scanner, both can be found in the manual of your scanner.
 | 
						|
.TP
 | 
						|
.I any further comments
 | 
						|
if you have comments about the documentation (what could be done better), or you
 | 
						|
think I should know something, please include it.
 | 
						|
.TP
 | 
						|
.I some nice greetings
 |