kopia lustrzana https://gitlab.com/sane-project/backends
				
				
				
			
		
			
				
	
	
		
			179 wiersze
		
	
	
		
			5.0 KiB
		
	
	
	
		
			Groff
		
	
	
			
		
		
	
	
			179 wiersze
		
	
	
		
			5.0 KiB
		
	
	
	
		
			Groff
		
	
	
.TH sane\-artec 5 "11 Jul 2008" "@PACKAGEVERSION@" "SANE Scanner Access Now Easy"
 | 
						|
.IX sane\-artec
 | 
						|
 | 
						|
.SH NAME
 | 
						|
sane\-artec \- SANE backend for Artec flatbed scanners
 | 
						|
 | 
						|
.SH DESCRIPTION
 | 
						|
The
 | 
						|
.B sane\-artec
 | 
						|
library implements a SANE (Scanner Access Now Easy) backend
 | 
						|
that provides access to Artec/Ultima SCSI flatbed scanners.  At present,
 | 
						|
the following scanners are known to work at least partially with this backend:
 | 
						|
.PP
 | 
						|
.RS
 | 
						|
* Artec A6000C
 | 
						|
.br
 | 
						|
* Artec A6000C PLUS
 | 
						|
.br
 | 
						|
* Artec ViewStation AT3
 | 
						|
.br
 | 
						|
* BlackWidow BW4800SP (rebadged Artec AT3)
 | 
						|
.br
 | 
						|
* Artec ViewStation AT6
 | 
						|
.br
 | 
						|
* Artec ViewStation AT12
 | 
						|
.br
 | 
						|
* Artec AM12S
 | 
						|
.br
 | 
						|
* Plustek 19200S (rebadged Artec AM12S)
 | 
						|
.RE
 | 
						|
.PP
 | 
						|
Although this manual page is generally updated with each release,
 | 
						|
up-to-date information on new releases and extraneous helpful hints
 | 
						|
are available from the backend homepage:
 | 
						|
.br
 | 
						|
.br
 | 
						|
.RS
 | 
						|
.B http://www4.infi.net/~cpinkham/sane/
 | 
						|
.RE
 | 
						|
 | 
						|
.SH DOCUMENTATION
 | 
						|
 | 
						|
 | 
						|
.SH CONFIGURATION
 | 
						|
 | 
						|
The contents of the
 | 
						|
.I artec.conf
 | 
						|
file are a list of device names that
 | 
						|
correspond to Artec scanners.  Empty lines and lines starting with a
 | 
						|
hash mark (#) are ignored.  See
 | 
						|
.I sane\-scsi(5)
 | 
						|
on details of what constitutes a valid device name.
 | 
						|
 | 
						|
Sample file:
 | 
						|
.br
 | 
						|
.br
 | 
						|
.nf
 | 
						|
# artec.conf
 | 
						|
#
 | 
						|
# this is a comment.
 | 
						|
#
 | 
						|
# this line says search for any SCSI devices which are scanners and have
 | 
						|
#     a vendor string of 'ULTIMA'
 | 
						|
scsi ULTIMA
 | 
						|
#
 | 
						|
# the next line forces the backend to assume the next scanner found has
 | 
						|
#     the specified vendor string (useful for testing rebadged models).
 | 
						|
vendor ULTIMA
 | 
						|
#
 | 
						|
# the next line forces the backend to assume the next scanner found has
 | 
						|
#     the specified model string (useful for testing rebadged models).
 | 
						|
model AT3
 | 
						|
#
 | 
						|
# now a line that actually specifies a device.  The backend is going to
 | 
						|
#     assume this is an Artec/Ultima AT3 because we forced the vendor and
 | 
						|
#     model above.
 | 
						|
/dev/scanner
 | 
						|
#
 | 
						|
# once we hit a scanner device line, the forced vendor and model
 | 
						|
# string are
 | 
						|
#     'forgotten', so the vendor and model for this next device will be
 | 
						|
#     determined from the result of a SCSI inquiry.
 | 
						|
/dev/sge
 | 
						|
#
 | 
						|
.fi
 | 
						|
 | 
						|
.SH SCSI ADAPTER TIPS
 | 
						|
 | 
						|
Some Artec scanners come with an included SCSI adapter.  If your scanner came
 | 
						|
with a DTC ISA scsi cards, you can probably use it with recent (>= 2.2.0)
 | 
						|
kernels using the generic NCR5380 support.  You must pass the following
 | 
						|
boot argument to the kernel: "dtc3181e=0x2c0,0"
 | 
						|
.br
 | 
						|
I do not have any information on the PCI SCSI adapter included with some
 | 
						|
newer Artec scanners.
 | 
						|
 | 
						|
.SH FILES
 | 
						|
.TP
 | 
						|
.I @CONFIGDIR@/artec.conf
 | 
						|
The backend configuration file (see also description of
 | 
						|
.B SANE_CONFIG_DIR
 | 
						|
below).
 | 
						|
.TP
 | 
						|
.I @LIBDIR@/libsane\-artec.a
 | 
						|
The static library implementing this backend.
 | 
						|
.TP
 | 
						|
.I @LIBDIR@/libsane\-artec.so
 | 
						|
The shared library implementing this backend (present on systems that
 | 
						|
support dynamic loading).
 | 
						|
.SH ENVIRONMENT
 | 
						|
.TP
 | 
						|
.B SANE_CONFIG_DIR
 | 
						|
This environment variable specifies the list of directories that may
 | 
						|
contain the configuration file.  Under UNIX, the directories are
 | 
						|
separated by a colon (`:'), under OS/2, they are separated by a semi-
 | 
						|
colon (`;').  If this variable is not set, the configuration file is
 | 
						|
searched in two default directories: first, the current working direc-
 | 
						|
tory (".") and then in @CONFIGDIR@.  If the value of the
 | 
						|
environment variable ends with the directory separator character, then
 | 
						|
the default directories are searched after the explicitly specified
 | 
						|
directories.  For example, setting
 | 
						|
.B SANE_CONFIG_DIR
 | 
						|
to "/tmp/config:" would result in directories "tmp/config", ".", and
 | 
						|
"@CONFIGDIR@" being searched (in this order).
 | 
						|
.TP
 | 
						|
.B SANE_DEBUG_ARTEC
 | 
						|
If the library was compiled with debug support enabled, this environment
 | 
						|
variable controls the debug level for this backend. E.g., a value of 128
 | 
						|
requests all debug output to be printed. Smaller levels reduce verbosity:
 | 
						|
SANE_DEBUG_ARTEC values
 | 
						|
 | 
						|
.ft CR
 | 
						|
.nf
 | 
						|
Number  Remark
 | 
						|
\ 
 | 
						|
 0       print important errors
 | 
						|
 1       print errors
 | 
						|
 2       print sense
 | 
						|
 3       print warnings
 | 
						|
 4       print scanner-inquiry
 | 
						|
 5       print information
 | 
						|
 6       print less important information
 | 
						|
 7       print major called procedures
 | 
						|
 8       print all called procedures
 | 
						|
 9       print procedure info/data messages
 | 
						|
 10      print called sane\-init-routines
 | 
						|
 11      print called sane\-procedures
 | 
						|
 12      print sane infos
 | 
						|
 13      print sane option-control messages
 | 
						|
\ 
 | 
						|
 50      print verbose data/debug messages
 | 
						|
\ 
 | 
						|
 == 100  print software RGB calibration data
 | 
						|
 == 101  print raw data from scanner to artec.data.raw file
 | 
						|
\ 
 | 
						|
 == 128  print out all messages
 | 
						|
.fi
 | 
						|
.ft R
 | 
						|
.PP
 | 
						|
Example:
 | 
						|
export SANE_DEBUG_ARTEC=13
 | 
						|
 | 
						|
.SH BUGS
 | 
						|
 | 
						|
Known bugs in this release: A6000C+ users with firmware v1.92 or
 | 
						|
earlier have problems with the backend, the cause has not been determined.
 | 
						|
Sometimes the backend is not particularly robust, you can possibly lock up
 | 
						|
the SCSI bus (and/or machine) by not having patience enough when scanning.
 | 
						|
3-channel gamma correction is not implemented and single-channel gamma
 | 
						|
correction is not totally working on models other than the AT3.
 | 
						|
 | 
						|
.SH "SEE ALSO"
 | 
						|
 | 
						|
sane(7), sane\-scsi(5)
 | 
						|
 | 
						|
.SH AUTHOR
 | 
						|
 | 
						|
Chris Pinkham (cpinkham@corp.infi.net)
 |