.TH sane\-plustek_pp 5 "14 Jul 2008" "@PACKAGEVERSION@" "SANE Scanner Access Now Easy"
 | 
						|
.IX sane\-plustek_pp
 | 
						|
.SH NAME
 | 
						|
sane\-plustek_pp \- SANE backend for Plustek parallel port
 | 
						|
flatbed scanners
 | 
						|
.SH DESCRIPTION
 | 
						|
The
 | 
						|
.B sane\-plustek_pp
 | 
						|
library implements a SANE (Scanner Access Now Easy) backend that
 | 
						|
provides access to Plustek ASIC 9600[1/3] and P9800[1/3] based
 | 
						|
parallel port flatbed scanners.
 | 
						|
The access of the scanner is either done directly by the backend
 | 
						|
or via kernel module, called pt_drv which can be created out of
 | 
						|
the plustek_pp backend code \- see also section
 | 
						|
.B "BUILDING THE KERNEL MODULE"
 | 
						|
for further information. 
 | 
						|
 | 
						|
.SH "SUPPORTED DEVICES"
 | 
						|
 | 
						|
At present, the following scanners should work with this backend
 | 
						|
and/or the kernel module:
 | 
						|
.PP
 | 
						|
.B "PLUSTEK SCANNERS"
 | 
						|
.PP
 | 
						|
.ft CR
 | 
						|
.nf
 | 
						|
Parallelport Model:    ASIC: Properties:
 | 
						|
---------------------- ----- ------------------------
 | 
						|
OpticPro PT12          98003 600x1200 dpi 36bit 512Kb
 | 
						|
OpticPro P12           98003 600x1200 dpi 36bit 512Kb
 | 
						|
OpticPro 9636T/12000T  98001 600x1200 dpi 36bit 512Kb
 | 
						|
OpticPro 12000P Turbo  98001 600x1200 dpi 36bit 512Kb
 | 
						|
OpticPro 9636P+/Turbo  98001 600x1200 dpi 36bit 512Kb
 | 
						|
OpticPro 9636P         96003 600x1200 dpi 36bit 128Kb
 | 
						|
OpticPro 12000P/96000P 96003 600x1200 dpi 36bit 128Kb
 | 
						|
OpticPro 1236P         96003 600x1200 dpi 30bit 128Kb
 | 
						|
OpticPro 9600P         96003 600x1200 dpi 30bit 128Kb
 | 
						|
OpticPro 9630P/FBIV    96003 600x1200 dpi 30bit 128Kb
 | 
						|
OpticPro 9630PL (14")  96003 600x1200 dpi 30bit 128Kb
 | 
						|
OpticPro A3I           96003  400x800 dpi 36bit 128Kb
 | 
						|
OpticPro 600P/6000P    96003  300x600 dpi 30bit  32Kb
 | 
						|
OpticPro 4831P         96003  300x600 dpi 30bit  32Kb
 | 
						|
OpticPro 4830P/FBIII   96003  300x600 dpi 30bit  32Kb
 | 
						|
OpticPro 4800P/FBII    96001  300x600 dpi 24bit  32Kb
 | 
						|
.fi
 | 
						|
.ft R
 | 
						|
.PP
 | 
						|
 | 
						|
.B "PRIMAX SCANNERS"
 | 
						|
 | 
						|
There are some scanners sold by Primax, but they are in fact
 | 
						|
Plustek devices. These scanners are also supported.
 | 
						|
The following table will show the relationship:
 | 
						|
.PP
 | 
						|
.ft CR
 | 
						|
.nf
 | 
						|
Model:                      Plustek Model:  Remarks:
 | 
						|
--------------------------- --------------  ------------
 | 
						|
Colorado 4800               OpticPro 4800   not tested
 | 
						|
Compact 4800 Direct         OpticPro 600    mov=2
 | 
						|
Compact 4800 Direct 30bit   OpticPro 4830   mov=7
 | 
						|
Compact 9600 Direct 30bit   OpticPro 9630   works
 | 
						|
.fi
 | 
						|
.ft R
 | 
						|
.PP
 | 
						|
 | 
						|
.B "GENIUS SCANNERS"
 | 
						|
 | 
						|
The following devices are sold as Genius Scanners, but are in fact
 | 
						|
Plustek devices.
 | 
						|
The table will show the relationship:
 | 
						|
.PP
 | 
						|
.ft CR
 | 
						|
.nf
 | 
						|
Model:                      Remarks:
 | 
						|
--------------------------- ----------------------------
 | 
						|
Colorpage Vivid III V2      Like P12 but has two buttons
 | 
						|
                            and Wolfson DAC
 | 
						|
.fi
 | 
						|
.ft R
 | 
						|
.PP
 | 
						|
 | 
						|
.B "ARIES SCANNERS"
 | 
						|
 | 
						|
There's one scanner sold as Aries Scanner, but is in fact a
 | 
						|
Plustek device.
 | 
						|
The following table will show the relationship:
 | 
						|
.PP
 | 
						|
.ft CR
 | 
						|
.nf
 | 
						|
Model:                      Plustek Model:  Remarks:
 | 
						|
--------------------------- --------------  ------------
 | 
						|
Scan-It 4800                OpticPro 600    mov=2
 | 
						|
.fi
 | 
						|
.ft R
 | 
						|
.PP
 | 
						|
 | 
						|
.B "BrightScan SCANNERS"
 | 
						|
 | 
						|
There's one scanner sold as BrightScan OpticPro Scanner, this is also
 | 
						|
a rebadged Plustek device.
 | 
						|
The following table will show the relationship:
 | 
						|
.PP
 | 
						|
.ft CR
 | 
						|
.nf
 | 
						|
Model:                      Remarks:
 | 
						|
--------------------------- ----------------------------
 | 
						|
BrightScan OpticPro         OpticPro P12
 | 
						|
.fi
 | 
						|
.ft R
 | 
						|
 | 
						|
.SH "DEVICE NAMES"
 | 
						|
This backend works in two modes, the so called "direct-mode"
 | 
						|
and the "kernel-mode". In direct-mode, the user-space backend is
 | 
						|
used, in kernel-mode, you should have a kernel-module named pt_drv
 | 
						|
loaded.
 | 
						|
This backends default device is:
 | 
						|
.PP
 | 
						|
.RS
 | 
						|
.I 0x378
 | 
						|
.RE
 | 
						|
.PP
 | 
						|
This "default device" will be used, if no configuration
 | 
						|
file can be found. It is rather the base address of the parallel port
 | 
						|
on i386 machines.
 | 
						|
.PP
 | 
						|
As the backend supports up to four devices, it is possible to
 | 
						|
specify them in the configuration file
 | 
						|
.PP
 | 
						|
.RS
 | 
						|
.I @CONFIGDIR@/plustek_pp.conf
 | 
						|
.RE
 | 
						|
.PP
 | 
						|
See this file for examples.
 | 
						|
.PP
 | 
						|
 | 
						|
.SH "CONFIGURATION"
 | 
						|
.PP
 | 
						|
This section describes the backends' configuration file entries.
 | 
						|
The file is located at:
 | 
						|
.I @CONFIGDIR@/plustek_pp.conf
 | 
						|
.PP
 | 
						|
For a proper setup, you will need at least two entries:
 | 
						|
.RS
 | 
						|
.I [direct]
 | 
						|
.br
 | 
						|
.I device 0x378
 | 
						|
.RE
 | 
						|
.PP
 | 
						|
or
 | 
						|
.RS
 | 
						|
.I [kernel]
 | 
						|
.br
 | 
						|
.I device /dev/pt_drv
 | 
						|
.RE
 | 
						|
.PP
 | 
						|
.I direct
 | 
						|
tells the backend, that the following devicename (here
 | 
						|
.IR 0x378 )
 | 
						|
has to be interpreted as parallel port scanner device. In
 | 
						|
fact it is the address to use, alternatively you can use
 | 
						|
.I /dev/parport0
 | 
						|
if the backend has been compiled with libieee1284 support.
 | 
						|
.I kernel
 | 
						|
should only be used, when a kernel-module has been built
 | 
						|
out of the backend sources. See below for more instructions
 | 
						|
about this.
 | 
						|
.PP
 | 
						|
Further options:
 | 
						|
.PP
 | 
						|
option warmup t
 | 
						|
.RS
 | 
						|
.I t
 | 
						|
specifies the warmup period in seconds
 | 
						|
.RE
 | 
						|
.PP
 | 
						|
option lampOff t
 | 
						|
.RS
 | 
						|
.I t
 | 
						|
is the time in seconds for switching off the lamps in
 | 
						|
standby mode
 | 
						|
.RE
 | 
						|
.PP
 | 
						|
option lOffonEnd b
 | 
						|
.RS
 | 
						|
.I b
 | 
						|
specifies the behaviour when closing the backend, 1 --> switch
 | 
						|
lamps off, 0 --> do not change lamp status
 | 
						|
.RE
 | 
						|
.PP
 | 
						|
option mov m
 | 
						|
.RS
 | 
						|
.I m
 | 
						|
is the model override switch, which only works in direct mode.
 | 
						|
.TP
 | 
						|
.IR m " = 0"
 | 
						|
default: no override
 | 
						|
.TP
 | 
						|
.IR m " = 1"
 | 
						|
OpticPro 9630PL override (works if OP9630
 | 
						|
has been detected) forces legal size (14")
 | 
						|
.TP
 | 
						|
.IR m " = 2"
 | 
						|
Primax 4800Direct override (works if OP600
 | 
						|
has been detected) swaps red/green color
 | 
						|
.TP
 | 
						|
.IR m " = 3"
 | 
						|
OpticPro 9636 override (works if OP9636 has
 | 
						|
been detected) disables backends
 | 
						|
transparency/negative capabilities
 | 
						|
.TP
 | 
						|
.IR m " = 4"
 | 
						|
OpticPro 9636P override (works if OP9636 has
 | 
						|
been detected) disables backends
 | 
						|
transparency/negative capabilities
 | 
						|
.TP
 | 
						|
.IR m " = 5"
 | 
						|
OpticPro A3I override (works if OP12000 has
 | 
						|
been detected) enables A3 scanning
 | 
						|
.TP
 | 
						|
.IR m " = 6"
 | 
						|
OpticPro 4800P override (works if OP600
 | 
						|
has been detected) swaps red/green color
 | 
						|
.TP
 | 
						|
.IR m " = 7"
 | 
						|
Primax 4800Direct 30bit override (works if
 | 
						|
OP4830 has been detected)
 | 
						|
.RE
 | 
						|
.PP
 | 
						|
See the plustek_pp.conf file for examples.
 | 
						|
.PP
 | 
						|
 | 
						|
.SH "BUILDING THE KERNEL MODULE"
 | 
						|
As mentioned before, the plustek_pp backend code can also
 | 
						|
be compiled and installed as linux kernel module. To do so,
 | 
						|
you will need the source-files of this sane\-backend installation.
 | 
						|
Unpack this tar-ball and go to the directory:
 | 
						|
.br
 | 
						|
.I sane\-backends/doc/plustek
 | 
						|
.br
 | 
						|
Within this directory, you should find a script called:
 | 
						|
.br
 | 
						|
.I MakeModule.sh
 | 
						|
.br
 | 
						|
Now if your Linux kernelsources are installed correctly, 
 | 
						|
it should be possible to build, install and load the 
 | 
						|
module
 | 
						|
.B pt_drv.
 | 
						|
.B Please note, 
 | 
						|
that the kernelsources need to be configured correctly.
 | 
						|
Refer to your distributions 
 | 
						|
manual on how this is done. As root user, try
 | 
						|
.br
 | 
						|
.I ./MakeModule.sh
 | 
						|
.br
 | 
						|
the script will try and get all necessary information about your
 | 
						|
running kernel and will lead you through the whole installation
 | 
						|
process.
 | 
						|
.br
 | 
						|
.B Note: Installing and loading the can only be done as 
 | 
						|
superuser.
 | 
						|
.PP
 | 
						|
 | 
						|
.SH "KERNEL MODULE SETUP"
 | 
						|
The configuration of the kernel module is done by providing
 | 
						|
some or more options found below to the kernel module at
 | 
						|
load time. This can be done by invoking insmod with the
 | 
						|
appropriate parameters or appending the options to the file
 | 
						|
.B /etc/modules.conf (kernel < 2.6.x)
 | 
						|
or
 | 
						|
.B /etc/modprobe.conf (kernel >= 2.6.x)
 | 
						|
.PP
 | 
						|
.B
 | 
						|
The Options:
 | 
						|
.br
 | 
						|
lampoff=lll
 | 
						|
.RS
 | 
						|
The value
 | 
						|
.I lll
 | 
						|
tells the driver, after how many seconds to
 | 
						|
switch-off the lamp(s). The default value is 180.
 | 
						|
0 will disable this feature.
 | 
						|
.br
 | 
						|
.B HINT:
 | 
						|
Do not use a value that is too small, because often
 | 
						|
switching on/off the lamps will reduce their lifetime.
 | 
						|
.RE
 | 
						|
.PP
 | 
						|
port=ppp
 | 
						|
.RS
 | 
						|
.I ppp
 | 
						|
specifies the port base address, where the scanner
 | 
						|
is connected to. The default value is 0x378, which
 | 
						|
normaly is standard.
 | 
						|
.RE
 | 
						|
.PP
 | 
						|
warmup=www
 | 
						|
.RS
 | 
						|
.I www
 | 
						|
specifies the time in seconds, how long a lamp has to be on,
 | 
						|
until the driver will start to scan. The default value is 30.
 | 
						|
.RE
 | 
						|
.PP
 | 
						|
lOffonEnd=e
 | 
						|
.RS
 | 
						|
.I e
 | 
						|
specifies the behaviour when unloading the driver, 1 --> switch
 | 
						|
lamps off, 0 --> do not change lamp status
 | 
						|
.RE
 | 
						|
.PP
 | 
						|
slowIO=s
 | 
						|
.RS
 | 
						|
.I s
 | 
						|
specifies which I/O functions the driver should use, 1 --> use
 | 
						|
delayed functions, 0 --> use the non-delayed ones
 | 
						|
.RE
 | 
						|
.PP
 | 
						|
forceMode=fm
 | 
						|
.RS
 | 
						|
.I fm
 | 
						|
specifies port mode which should be used, 0 --> autodetection,
 | 
						|
1 --> use SPP mode and 2 --> use EPP mode
 | 
						|
.RE
 | 
						|
.PP
 | 
						|
mov=m
 | 
						|
.RS
 | 
						|
.TP
 | 
						|
.IR m " = 0"
 | 
						|
default: no override
 | 
						|
.TP
 | 
						|
.IR m " = 1"
 | 
						|
OpticPro 9630PL override (works if OP9630
 | 
						|
has been detected) forces legal size (14")
 | 
						|
.TP
 | 
						|
.IR m " = 2"
 | 
						|
Primax 4800Direct override (works if OP600
 | 
						|
has been detected) swaps red/green color
 | 
						|
.TP
 | 
						|
.IR m " = 3"
 | 
						|
OpticPro 9636 override (works if OP9636 has
 | 
						|
been detected) disables backends
 | 
						|
transparency/negative capabilities
 | 
						|
.TP
 | 
						|
.IR m " = 4"
 | 
						|
OpticPro 9636P override (works if OP9636 has
 | 
						|
been detected) disables backends
 | 
						|
transparency/negative capabilities
 | 
						|
.TP
 | 
						|
.IR m " = 5"
 | 
						|
OpticPro A3I override (works if OP12000 has
 | 
						|
been detected) enables A3 scanning
 | 
						|
.TP
 | 
						|
.IR m " = 6"
 | 
						|
OpticPro 4800P override (works if OP600
 | 
						|
has been detected) swaps red/green color
 | 
						|
.TP
 | 
						|
.IR m " = 7"
 | 
						|
Primax 4800Direct 30bit override (works if
 | 
						|
OP4830 has been detected)
 | 
						|
.RE
 | 
						|
.PP
 | 
						|
Sample entry for file
 | 
						|
.B "/etc/modules.conf"
 | 
						|
:
 | 
						|
.br
 | 
						|
.I alias char\-major\-40 pt_drv
 | 
						|
.br
 | 
						|
.I pre-install pt_drv modprobe -k parport
 | 
						|
.br
 | 
						|
.I options pt_drv lampoff=180 warmup=15 port=0x378 lOffonEnd=0 mov=0 slowIO=0 forceMode=0
 | 
						|
.PP
 | 
						|
For multidevice support, simply add values separated by commas to
 | 
						|
the different options
 | 
						|
.br
 | 
						|
.I options pt_drv port=0x378,0x278 mov=0,4 slowIO=0,1 forceMode=0,1
 | 
						|
.PP
 | 
						|
Remember to call depmod after changing /etc/conf.modules.
 | 
						|
.PP
 | 
						|
 | 
						|
.SH "PARALLEL PORT MODES"
 | 
						|
.PP
 | 
						|
The current driver works best, when the parallel port
 | 
						|
has been set to EPP-mode. When detecting any other
 | 
						|
mode such as ECP or PS/2 the driver tries to set to a
 | 
						|
faster, supported mode. If this fails, it will use the
 | 
						|
SPP mode, as this mode should work with all Linux supported
 | 
						|
parallel ports. If in doubt, enter your BIOS and set it to
 | 
						|
any mode except ECP.
 | 
						|
.PP
 | 
						|
Former Plustek scanner models (4830, 9630) supplied a
 | 
						|
ISA parallel port adapter card. This card is
 | 
						|
.BR not
 | 
						|
supported by the driver.
 | 
						|
.PP
 | 
						|
The ASIC 96001/3 based models have sometimes trouble with
 | 
						|
high resolution modes. If you encounter sporadic corrupted
 | 
						|
images (parts duplicated or shifted horizontally) kill all
 | 
						|
other applications before scanning and (if sufficient
 | 
						|
memory available) disable swapping.
 | 
						|
.PP
 | 
						|
See the plustek_pp.conf file for examples.
 | 
						|
.PP
 | 
						|
 | 
						|
.SH FILES
 | 
						|
.TP
 | 
						|
.I @CONFIGDIR@/plustek_pp.conf
 | 
						|
The backend configuration file
 | 
						|
.TP
 | 
						|
.I @LIBDIR@/libsane\-plustek_pp.a
 | 
						|
The static library implementing this backend.
 | 
						|
.TP
 | 
						|
.I @LIBDIR@/libsane\-plustek_pp.so
 | 
						|
The shared library implementing this backend (present on systems that
 | 
						|
support dynamic loading).
 | 
						|
.TP
 | 
						|
.I /lib/modules/<Kernel-Version>/kernel/drivers/parport/pt_drv.o
 | 
						|
The Linux kernelmodule for kernels < 2.6.x.
 | 
						|
.TP
 | 
						|
.I /lib/modules/<Kernel-Version>/kernel/drivers/parport/pt_drv.ko
 | 
						|
The Linux kernelmodule for kernels >= 2.6.x.
 | 
						|
.PP
 | 
						|
 | 
						|
.SH ENVIRONMENT
 | 
						|
.TP
 | 
						|
.B SANE_CONFIG_DIR
 | 
						|
This environment variable specifies the list of directories that may
 | 
						|
contain the configuration file.  Under UNIX, the directories are
 | 
						|
separated by a colon (`:'), under OS/2, they are separated by a
 | 
						|
semi-colon (`;').  If this variable is not set, the configuration file
 | 
						|
is searched in two default directories: first, the current working
 | 
						|
directory (".") and then in @CONFIGDIR@.  If the value of the
 | 
						|
environment variable ends with the directory separator character, then
 | 
						|
the default directories are searched after the explicitly specified
 | 
						|
directories.  For example, setting
 | 
						|
.B SANE_CONFIG_DIR
 | 
						|
to "/tmp/config:" would result in directories "tmp/config", ".", and
 | 
						|
"@CONFIGDIR@" being searched (in this order).
 | 
						|
.TP
 | 
						|
.B SANE_DEBUG_PLUSTEK_PP
 | 
						|
If the library was compiled with debug support enabled, this
 | 
						|
environment variable controls the debug level for this backend.  Higher
 | 
						|
debug levels increase the verbosity of the output.
 | 
						|
 | 
						|
Example:
 | 
						|
export SANE_DEBUG_PLUSTEK_PP=10
 | 
						|
 | 
						|
.SH "SEE ALSO"
 | 
						|
.BR sane (7),
 | 
						|
.br
 | 
						|
.I @DOCDIR@/plustek/Plustek\-PARPORT.changes
 | 
						|
.br
 | 
						|
.I http://www.gjaeger.de/scanner/plustek_pp/
 | 
						|
 | 
						|
.SH "CONTACT AND BUG-REPORTS"
 | 
						|
Please send any information and bug-reports to:
 | 
						|
.br
 | 
						|
.B SANE Mailing List
 | 
						|
.PP
 | 
						|
Additional info and hints can be obtained from our
 | 
						|
.br
 | 
						|
Mailing-List archive at:
 | 
						|
.br
 | 
						|
.B http://www.sane\-project.org/mailing\-lists.html
 | 
						|
.PP
 | 
						|
or directly from the projects' homepage at:
 | 
						|
.br
 | 
						|
.B http://www.gjaeger.de/scanner/plustek_pp/
 | 
						|
.PP
 | 
						|
To obtain debug messages from the backend, please set the
 | 
						|
environment-variable
 | 
						|
.I SANE_DEBUG_PLUSTEK_PP
 | 
						|
before calling your favorite scan-frontend (i.e. xscanimage).
 | 
						|
.br
 | 
						|
.B i.e.: export SANE_DEBUG_PLUSTEK_PP=20 ; xscanimage
 | 
						|
.PP
 | 
						|
The value controls the verbosity of the backend.
 | 
						|
.PP
 | 
						|
 | 
						|
.SH "KNOWN BUGS & RESTRICTIONS"
 | 
						|
.PP
 | 
						|
* The Halftoning works, but the quality is poor
 | 
						|
.PP
 | 
						|
* Printers (especially HP models) will start to
 | 
						|
print during scanning. This in fact is a problem
 | 
						|
to other printers too, using bidirectional protocol
 | 
						|
(see www.plustek.com (TAIWAN) page for further details)
 | 
						|
.PP
 | 
						|
* The driver does not support these manic scalings up
 | 
						|
to 16 times the physical resolution. The only scaling
 | 
						|
is done on resolutions between the physical resolution
 | 
						|
of the CCD-sensor and the stepper motor i.e. you have a
 | 
						|
600x1200 dpi scanner and you are scanning using 800dpi,
 | 
						|
so scaling is necessary, because the sensor only delivers
 | 
						|
600dpi but the motor is capable to perform 800dpi steps.
 | 
						|
.PP
 | 
						|
* On some devices, the pictures seems bluish
 | 
						|
.PP
 | 
						|
.I ASIC 98001 based models:
 | 
						|
.PP
 | 
						|
* The 300dpi transparency and negative mode does not work
 | 
						|
correctly.
 | 
						|
.PP
 | 
						|
* There is currently no way to distinguish a model with
 | 
						|
and without transparency unit.
 | 
						|
.PP
 | 
						|
* The scanned images seem to be too dark (P9636T)
 | 
						|
.PP
 | 
						|
.I ASIC 96003/1 based models:
 | 
						|
.PP
 | 
						|
* 30bit mode is currently not supported.
 | 
						|
.PP
 | 
						|
* On low end systems under heavy system load the
 | 
						|
driver may lose data, which can result in picture 
 | 
						|
corruption or cause the sensor to hit the scan bed.
 | 
						|
.PP
 | 
						|
* The scanning speed on 600x1200 dpi models is slow.
 | 
						|
.PP
 | 
						|
* The scanning quality of the A3I is poor
 |