kopia lustrzana https://gitlab.com/sane-project/backends
216 wiersze
6.8 KiB
Groff
216 wiersze
6.8 KiB
Groff
.TH sane-hp 5 "12-February 2000"
|
|
.IX sane-hp
|
|
.SH NAME
|
|
sane-hp - SANE backend for HP ScanJet scanners
|
|
.SH DESCRIPTION
|
|
The
|
|
.B sane-hp
|
|
library implements a SANE (Scanner Access Now Easy) backend that
|
|
provides access to HP ScanJet scanners. At present, the following
|
|
scanners are known positively to work with this backend:
|
|
.PP
|
|
.RS
|
|
Model: Product id: Interface:
|
|
.br
|
|
---------- ----------- ----------
|
|
.br
|
|
ScanJet Plus C9195A HP Parallel Interface Card
|
|
.br
|
|
ScanJet IIc C1750A 3226 SCSI
|
|
.br
|
|
ScanJet IIcx C2500A 3332 SCSI
|
|
.br
|
|
ScanJet IIp C1790A SCSI
|
|
.br
|
|
ScanJet 3C C2520A 3503 SCSI
|
|
.br
|
|
ScanJet 3P C2570A 3406 SCSI
|
|
.br
|
|
ScanJet 4C C2520A SCSI
|
|
.br
|
|
ScanJet 4P C1130A 3540 SCSI
|
|
.br
|
|
ScanJet 4100C C6290A USB
|
|
.br
|
|
ScanJet 5P C5110A SCSI
|
|
.br
|
|
ScanJet 5100C C5190A parallel port
|
|
.br
|
|
ScanJet 5200C C7190A 3846 parallel port/USB
|
|
.br
|
|
ScanJet 6100C C2520A 3644 SCSI
|
|
.br
|
|
ScanJet 6200C C6270A 3828 SCSI/USB
|
|
.br
|
|
ScanJet 6250C C6270A 3828 SCSI/USB
|
|
.br
|
|
ScanJet 6300C C7670A SCSI/USB
|
|
.br
|
|
ScanJet 6350C C7670A SCSI/USB
|
|
.br
|
|
PhotoSmart C5100A R029,R030,R032 SCSI
|
|
.RE
|
|
.PP
|
|
Support for models 5100C/5200C connected to the parallel port requires
|
|
the ppSCSI driver available at http://www.torque.net/parport/ppscsi.html
|
|
(under development)
|
|
.PP
|
|
Support for models 5200C/6200C/6250C/6300C/6350C connected to the USB requires
|
|
an USB driver available at http://www.jump.net/~dnelson/linux/usb
|
|
(under development)
|
|
.PP
|
|
If you own a ScanJet scanner other than the ones listed above, please
|
|
let us know if your model works with this backend. To do this, send a
|
|
mail with the relevant information for your scanner to
|
|
.IR sane\-devel@mostang.com .
|
|
.SH "DEVICE NAMES"
|
|
This backend expects device names of the form:
|
|
.PP
|
|
.RS
|
|
.I special
|
|
.RE
|
|
.PP
|
|
Where
|
|
.I special
|
|
is the UNIX path-name for the special device that corresponds to the
|
|
scanner. For SCSI scanners the special device name must be a generic SCSI
|
|
device or a symlink to such a device. Under Linux, such a device name could be
|
|
.I /dev/sga
|
|
or
|
|
.IR /dev/sge ,
|
|
for example. For the Hp ScanJet Plus the special device name must be the device
|
|
that corresponds to the parallel interface card that was shipped with the
|
|
scanner. That is
|
|
.I /dev/hpscan
|
|
A special driver is required for this card. See ftp://rvs.ctrl-c.liu.se/pub/wingel/hpscan for details.
|
|
.SH CONFIGURATION
|
|
The contents of the
|
|
.I hp.conf
|
|
file is a list of options and device names that correspond to HP ScanJet
|
|
scanners. Empty lines and lines starting with a hash mark
|
|
(#) are ignored. See sane-scsi(5) on details of what constitutes
|
|
a valid device name.
|
|
.PP
|
|
Options specified infront of the first line that keeps a device name
|
|
are defaults for all devices. Options specified below a line that
|
|
keeps a device name apply just to the most recently mentioned device.
|
|
.PP
|
|
Supported options are
|
|
.BR connect-scsi ,
|
|
.BR connect-device
|
|
and
|
|
.BR enable-image-buffering .
|
|
|
|
Option
|
|
.B connect-scsi
|
|
specifies that the scanner is connected to the system by SCSI.
|
|
Input/output is performed using SCSI-commands.
|
|
This is the default.
|
|
|
|
Option
|
|
.B connect-device
|
|
specifies that the scanner is connected to the system by a special
|
|
device. Input/output is performed by read()/write()-operations
|
|
on the device. This option must be used for HP ScanJet Plus.
|
|
|
|
Option
|
|
.B enable-image-buffering
|
|
stores the scanned image in memory before passing it to the frontend. Could be
|
|
used in case of forward/backward moving scanner.
|
|
.PP
|
|
A sample configuration file is shown below:
|
|
.PP
|
|
.RS
|
|
/dev/scanner
|
|
.br
|
|
# this is a comment
|
|
.br
|
|
/dev/hpscan
|
|
.br
|
|
option connect-device
|
|
.RE
|
|
.SH FILES
|
|
.TP
|
|
.I @CONFIGDIR@/hp.conf
|
|
The backend configuration file (see also description of
|
|
.B SANE_CONFIG_DIR
|
|
below).
|
|
.TP
|
|
.I @LIBDIR@/libsane-hp.a
|
|
The static library implementing this backend.
|
|
.TP
|
|
.I @LIBDIR@/libsane-hp.so
|
|
The shared library implementing this backend (present on systems that
|
|
support dynamic loading).
|
|
.TP
|
|
.I $HOME/.sane/calib-hp:<device>.dat
|
|
Calibration data for HP PhotoSmart PhotoScanner that is retrieved from the
|
|
scanner after calibration. The data is uploaded to the scanner at start
|
|
of the backend if it is in media mode 'print media' or if the media mode is
|
|
changed to 'print media'.
|
|
.SH ENVIRONMENT
|
|
.TP
|
|
.B SANE_CONFIG_DIR
|
|
This environment variable specifies the list of directories that may
|
|
contain the configuration file. Under UNIX, the directories are
|
|
separated by a colon (`:'), under OS/2, they are separated by a
|
|
semi-colon (`;'). If this variable is not set, the configuration file
|
|
is searched in two default directories: first, the current working
|
|
directory (".") and then in @CONFIGDIR@. If the value of the
|
|
environment variable ends with the directory separator character, then
|
|
the default directories are searched after the explicitly specified
|
|
directories. For example, setting
|
|
.B SANE_CONFIG_DIR
|
|
to "/tmp/config:" would result in directories "tmp/config", ".", and
|
|
"@CONFIGDIR@" being searched (in this order).
|
|
.TP
|
|
.B SANE_DEBUG_HP
|
|
If the library was compiled with debug support enabled, this
|
|
environment variable controls the debug level for this backend. E.g.,
|
|
a value of 128 requests all debug output to be printed. Smaller
|
|
levels reduce verbosity.
|
|
|
|
.SH BUGS
|
|
.TP
|
|
.B HP PhotoSmart PhotoScanner
|
|
In media mode 'slide' and 'negative', scan resolutions are rounded to
|
|
multiple of 300 dpi. The scanner does not scale the data correctly
|
|
on other resolutions. Some newer models (firmware code R030 and later)
|
|
do not support adjustment of contrast/intensity level and tone map.
|
|
The backend will simulate this by software, but only for gray
|
|
and 24 bit color.
|
|
.TP
|
|
.B Automatic Document Feeder (ADF)
|
|
For use of the ADF with xscanimage(1), first place paper in the ADF and
|
|
then change option scantype to 'ADF'. Press 'change document'
|
|
to load a sheet. Then press 'scan' to start a scan.
|
|
Maybe it is sufficient to press 'scan' without 'change document'
|
|
for repeated scans. The use of the preview window is not recommended
|
|
when working with the ADF.
|
|
|
|
.TP
|
|
.B Immediate actions
|
|
Some actions in xscanimage(1) (i.e. unload, select media, calibrate)
|
|
have an immediate effect on the scanner without starting a scan.
|
|
These options can not be used with scanimage.
|
|
|
|
.SH TODO
|
|
.TP
|
|
.B HP PhotoSmart PhotoScanner
|
|
PhotoScanners with firmware release R030 and up have
|
|
no firmware support for contrast/brightness/gamma table. In the current
|
|
backend this is simulated by software on 24 bits data.
|
|
Simulation on 30 bits should give better results.
|
|
.TP
|
|
.B Parallel scanner support
|
|
Beside the ScanJet Plus which came with its own parallel interface card,
|
|
currently only the HP ScanJet 5100C/5200C are supported.
|
|
These scanners are using an internal parallel-to-SCSI converter which
|
|
is supported by the ppSCSI-driver (see above).
|
|
|
|
.SH "SEE ALSO"
|
|
sane\-scsi(5)
|
|
.SH AUTHOR
|
|
The sane-hp backend was written by Geoffrey T. Dairiki. HP PhotoSmart
|
|
PhotoScanner support by Peter Kirchgessner.
|