kopia lustrzana https://gitlab.com/sane-project/backends
				
				
				
			
		
			
				
	
	
		
			169 wiersze
		
	
	
		
			7.0 KiB
		
	
	
	
		
			C++
		
	
	
			
		
		
	
	
			169 wiersze
		
	
	
		
			7.0 KiB
		
	
	
	
		
			C++
		
	
	
/* sane - Scanner Access Now Easy.
 | 
						|
 | 
						|
   Copyright (C) 2019 Povilas Kanapickas <povilas@radix.lt>
 | 
						|
 | 
						|
   This file is part of the SANE package.
 | 
						|
 | 
						|
   This program is free software; you can redistribute it and/or
 | 
						|
   modify it under the terms of the GNU General Public License as
 | 
						|
   published by the Free Software Foundation; either version 2 of the
 | 
						|
   License, or (at your option) any later version.
 | 
						|
 | 
						|
   This program is distributed in the hope that it will be useful, but
 | 
						|
   WITHOUT ANY WARRANTY; without even the implied warranty of
 | 
						|
   MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE.  See the GNU
 | 
						|
   General Public License for more details.
 | 
						|
 | 
						|
   You should have received a copy of the GNU General Public License
 | 
						|
   along with this program; if not, write to the Free Software
 | 
						|
   Foundation, Inc., 59 Temple Place - Suite 330, Boston,
 | 
						|
   MA 02111-1307, USA.
 | 
						|
 | 
						|
   As a special exception, the authors of SANE give permission for
 | 
						|
   additional uses of the libraries contained in this release of SANE.
 | 
						|
 | 
						|
   The exception is that, if you link a SANE library with other files
 | 
						|
   to produce an executable, this does not by itself cause the
 | 
						|
   resulting executable to be covered by the GNU General Public
 | 
						|
   License.  Your use of that executable is in no way restricted on
 | 
						|
   account of linking the SANE library code into it.
 | 
						|
 | 
						|
   This exception does not, however, invalidate any other reasons why
 | 
						|
   the executable file might be covered by the GNU General Public
 | 
						|
   License.
 | 
						|
 | 
						|
   If you submit changes to SANE to the maintainers to be included in
 | 
						|
   a subsequent release, you agree by submitting the changes that
 | 
						|
   those changes may be distributed with this exception intact.
 | 
						|
 | 
						|
   If you write modifications of your own for SANE, it is your choice
 | 
						|
   whether to permit this exception to apply to your modifications.
 | 
						|
   If you do not wish that, delete this exception notice.
 | 
						|
*/
 | 
						|
 | 
						|
#ifndef BACKEND_GENESYS_COMMAND_SET_H
 | 
						|
#define BACKEND_GENESYS_COMMAND_SET_H
 | 
						|
 | 
						|
#include "device.h"
 | 
						|
#include "fwd.h"
 | 
						|
#include <cstdint>
 | 
						|
 | 
						|
namespace genesys {
 | 
						|
 | 
						|
 | 
						|
/** Scanner command set description.
 | 
						|
 | 
						|
    This description contains parts which are common to all scanners with the
 | 
						|
    same command set, but may have different optical resolution and other
 | 
						|
    parameters.
 | 
						|
 */
 | 
						|
class CommandSet
 | 
						|
{
 | 
						|
public:
 | 
						|
    virtual ~CommandSet() = default;
 | 
						|
 | 
						|
    virtual bool needs_home_before_init_regs_for_scan(Genesys_Device* dev) const = 0;
 | 
						|
 | 
						|
    virtual void init(Genesys_Device* dev) const = 0;
 | 
						|
 | 
						|
    virtual void init_regs_for_warmup(Genesys_Device* dev, const Genesys_Sensor& sensor,
 | 
						|
                                      Genesys_Register_Set* regs) const = 0;
 | 
						|
 | 
						|
    virtual void init_regs_for_shading(Genesys_Device* dev, const Genesys_Sensor& sensor,
 | 
						|
                                       Genesys_Register_Set& regs) const = 0;
 | 
						|
    virtual void init_regs_for_scan(Genesys_Device* dev, const Genesys_Sensor& sensor,
 | 
						|
                                    Genesys_Register_Set& regs) const = 0;
 | 
						|
 | 
						|
    /** Set up registers for a scan. Similar to init_regs_for_scan except that the session is
 | 
						|
        already computed from the session
 | 
						|
    */
 | 
						|
    virtual void init_regs_for_scan_session(Genesys_Device* dev, const Genesys_Sensor& sensor,
 | 
						|
                                            Genesys_Register_Set* reg,
 | 
						|
                                            const ScanSession& session) const= 0;
 | 
						|
 | 
						|
    virtual void set_fe(Genesys_Device* dev, const Genesys_Sensor& sensor, std::uint8_t set) const = 0;
 | 
						|
    virtual void set_powersaving(Genesys_Device* dev, int delay) const = 0;
 | 
						|
    virtual void save_power(Genesys_Device* dev, bool enable) const = 0;
 | 
						|
 | 
						|
    virtual void begin_scan(Genesys_Device* dev, const Genesys_Sensor& sensor,
 | 
						|
                            Genesys_Register_Set* regs, bool start_motor) const = 0;
 | 
						|
    virtual void end_scan(Genesys_Device* dev, Genesys_Register_Set* regs,
 | 
						|
                          bool check_stop) const = 0;
 | 
						|
 | 
						|
 | 
						|
    /**
 | 
						|
     * Send gamma tables to ASIC
 | 
						|
     */
 | 
						|
    virtual void send_gamma_table(Genesys_Device* dev, const Genesys_Sensor& sensor) const = 0;
 | 
						|
 | 
						|
    virtual void offset_calibration(Genesys_Device* dev, const Genesys_Sensor& sensor,
 | 
						|
                                    Genesys_Register_Set& regs) const = 0;
 | 
						|
    virtual void coarse_gain_calibration(Genesys_Device* dev, const Genesys_Sensor& sensor,
 | 
						|
                                         Genesys_Register_Set& regs, int dpi) const = 0;
 | 
						|
    virtual SensorExposure led_calibration(Genesys_Device* dev, const Genesys_Sensor& sensor,
 | 
						|
                                           Genesys_Register_Set& regs) const = 0;
 | 
						|
 | 
						|
    virtual void wait_for_motor_stop(Genesys_Device* dev) const = 0;
 | 
						|
    virtual void move_back_home(Genesys_Device* dev, bool wait_until_home) const = 0;
 | 
						|
 | 
						|
    // Updates hardware sensor information in Genesys_Scanner.val[].
 | 
						|
    virtual void update_hardware_sensors(struct Genesys_Scanner* s) const = 0;
 | 
						|
 | 
						|
    /** Whether the scanner needs to call update_home_sensor_gpio before reading the status of the
 | 
						|
        home sensor. On some chipsets this is unreliable until update_home_sensor_gpio() is called.
 | 
						|
    */
 | 
						|
    virtual bool needs_update_home_sensor_gpio() const { return false; }
 | 
						|
 | 
						|
    /** Needed on some chipsets before reading the status of the home sensor to make this operation
 | 
						|
        reliable.
 | 
						|
    */
 | 
						|
    virtual void update_home_sensor_gpio(Genesys_Device& dev) const { (void) dev; }
 | 
						|
 | 
						|
    // functions for sheetfed scanners
 | 
						|
 | 
						|
    // load document into scanner
 | 
						|
    virtual void load_document(Genesys_Device* dev) const = 0;
 | 
						|
 | 
						|
    /** Detects is the scanned document has left scanner. In this case it updates the amount of
 | 
						|
        data to read and set up flags in the dev struct
 | 
						|
     */
 | 
						|
    virtual void detect_document_end(Genesys_Device* dev) const = 0;
 | 
						|
 | 
						|
    /// eject document from scanner
 | 
						|
    virtual void eject_document(Genesys_Device* dev) const = 0;
 | 
						|
 | 
						|
    /// move scanning head to transparency adapter
 | 
						|
    virtual void move_to_ta(Genesys_Device* dev) const = 0;
 | 
						|
 | 
						|
    /// write shading data calibration to ASIC
 | 
						|
    virtual void send_shading_data(Genesys_Device* dev, const Genesys_Sensor& sensor,
 | 
						|
                                   std::uint8_t* data, int size) const = 0;
 | 
						|
 | 
						|
    virtual bool has_send_shading_data() const
 | 
						|
    {
 | 
						|
        return true;
 | 
						|
    }
 | 
						|
 | 
						|
    /// calculate an instance of ScanSession for scanning with the given settings
 | 
						|
    virtual ScanSession calculate_scan_session(const Genesys_Device* dev,
 | 
						|
                                               const Genesys_Sensor& sensor,
 | 
						|
                                               const Genesys_Settings& settings) const = 0;
 | 
						|
 | 
						|
    /// cold boot init function
 | 
						|
    virtual void asic_boot(Genesys_Device* dev, bool cold) const = 0;
 | 
						|
 | 
						|
    /// checks if specific scan head is at home position
 | 
						|
    virtual bool is_head_home(Genesys_Device& dev, ScanHeadId scan_head) const = 0;
 | 
						|
 | 
						|
    /// enables or disables XPA slider motor
 | 
						|
    virtual void set_xpa_lamp_power(Genesys_Device& dev, bool set) const = 0;
 | 
						|
 | 
						|
    /// enables or disables XPA slider motor
 | 
						|
    virtual void set_motor_mode(Genesys_Device& dev, Genesys_Register_Set& regs,
 | 
						|
                                MotorMode mode) const = 0;
 | 
						|
};
 | 
						|
 | 
						|
} // namespace genesys
 | 
						|
 | 
						|
#endif // BACKEND_GENESYS_COMMAND_SET_H
 |