kopia lustrzana https://gitlab.com/sane-project/backends
152 wiersze
4.4 KiB
Groff
152 wiersze
4.4 KiB
Groff
.TH "sane\-lexmark" "5" "12 Jul 2008" "@PACKAGEVERSION@" "SANE Scanner Access Now Easy"
|
|
.IX sane\-lexmark
|
|
.SH "NAME"
|
|
sane\-lexmark \- SANE backend for Lexmark X1100/X1200 Series scanners
|
|
.SH "DESCRIPTION"
|
|
The
|
|
.B sane\-lexmark
|
|
library implements a SANE (Scanner Access Now Easy) backend that
|
|
provides access to the scanner part of Lexmark X1100/X1200 AIOs. This backend
|
|
should be considered
|
|
.B beta-quality
|
|
software!
|
|
.PP
|
|
The scanners that should work with this backend are:
|
|
.PP
|
|
.RS
|
|
.ft CR
|
|
.nf
|
|
Vendor Model status
|
|
\-\-\-\-\-\-\-\-\-\-\-\-\-\-\-\-\-\-\-\-\-\- \-\-\-\-\-\-\-\-\-\-\-
|
|
Lexmark X74 good
|
|
Lexmark X1110 untested
|
|
Lexmark X1140 untested
|
|
Lexmark X1150 good
|
|
Lexmark X1170 good
|
|
Lexmark X1180 good
|
|
Lexmark X1185 complete
|
|
Lexmark X12xx good in USB1.1,
|
|
not fully tested in USB2.0
|
|
Dell A920 good
|
|
.fi
|
|
.ft R
|
|
.RE
|
|
|
|
The options the backend supports can either be selected through
|
|
command line options to programs like scanimage or through GUI
|
|
elements in xscanimage or xsane.
|
|
|
|
.br
|
|
If you have any strange behavior, please report to the backend
|
|
maintainer or to the SANE mailing list.
|
|
|
|
Valid command line options and their syntax can be listed by using
|
|
.RS
|
|
scanimage \-\-help \-d lexmark:usb:<usb port>
|
|
.RE
|
|
|
|
.TP
|
|
.B Scan Mode Options
|
|
|
|
.TP
|
|
.B \-\-mode
|
|
selects the basic mode of operation of the scanner valid choices are
|
|
.IR Color ,
|
|
.I Gray
|
|
and
|
|
.I Lineart
|
|
The default mode is Color. The Lineart mode is black and white only (1 bit).
|
|
Grayscale will produce 256 levels of gray (8 bits). Color mode allows for over
|
|
16 million different colors produced from 24 bits of color information.
|
|
|
|
.TP
|
|
.B \-\-resolution
|
|
selects the resolution for a scan. The horizontal and vertical resolutions are set
|
|
by the value of this option. The scanner is capable of the following resolutions for the specified option value:
|
|
.PP
|
|
.RS
|
|
.ft CR
|
|
.nf
|
|
Value Hor. Resolution Vert. Resolution
|
|
\-\-\-\-\- \-\-\-\-\-\-\-\-\-\-\-\-\-\-\- \-\-\-\-\-\-\-\-\-\-\-\-\-\-\-\-\-\-\-
|
|
75 75dpi 75dpi
|
|
150 150dpi 150dpi
|
|
300 300dpi 300dpi
|
|
600 600dpi 600dpi
|
|
1200 600dpi 1200dpi (only for X11xx models with 'B2' sensor)
|
|
.fi
|
|
.ft R
|
|
.RE
|
|
|
|
.TP
|
|
.B \-\-preview
|
|
requests a preview scan. The resolution used for that scan is 75 dpi
|
|
and the scan area and the scan mode are as specified through their options,
|
|
or the default if not specified. The default value for preview mode is "no".
|
|
|
|
.TP
|
|
.B \-\-threshold
|
|
selects the minimum-brightness to get a white point. The threshold is only used with Lineart mode scans.
|
|
It is specified as a percentage in the range 0..100% (in steps of 1).
|
|
The default value of the threshold option is 50.
|
|
|
|
|
|
.SH "CONFIGURATION FILE"
|
|
The configuration file @CONFIGDIR@/lexmark.conf contains only the usb device id (eg usb 0x043d 0x007c).
|
|
|
|
|
|
.SH "FILES"
|
|
.TP
|
|
.I @LIBDIR@/libsane\-lexmark.a
|
|
The static library implementing this backend.
|
|
.TP
|
|
.I @LIBDIR@/libsane\-lexmark.so
|
|
The shared library implementing this backend (present on systems that
|
|
support dynamic loading).
|
|
|
|
|
|
.SH "ENVIRONMENT"
|
|
.TP
|
|
.B SANE_DEBUG_LEXMARK
|
|
.B SANE_DEBUG_LEXMARK_LOW
|
|
If the library was compiled with debug support enabled, this
|
|
environment variable controls the debug level for this backend. E.g.,
|
|
a value of 255 requests all debug output to be printed. Smaller levels
|
|
reduce verbosity.
|
|
|
|
|
|
.SH "LIMITATIONS"
|
|
The windows TWAIN driver has many more options than this SANE
|
|
backend. However they are only software adjustments. This backend only
|
|
implements what the scanner can support. For instance, shading correction
|
|
(vertical stripes due to sensor variation across its width) is done in
|
|
software. Head park position is also detected by software.
|
|
The data compression isn't supported for the X1200 series on USB 1.1,
|
|
leading to slow scans.
|
|
|
|
.SH "BUGS"
|
|
.br
|
|
No bugs currently known.
|
|
|
|
|
|
|
|
.SH "SEE ALSO"
|
|
sane\-scsi(5), scanimage(1), xscanimage(1), xsane(1), sane(7)
|
|
|
|
|
|
.SH "AUTHOR"
|
|
.TP
|
|
The backend was originally written by Fred Odendaal.
|
|
.I http://ca.geocities.com/freshshelf@rogers.com/
|
|
.TP
|
|
The new version is currently developed by St\['e]phane Voltz.
|
|
.I http://stef.dev.free.fr/sane/lexmark
|
|
.TP
|
|
X74 support was written by Torsten Houwaart (<ToHo@gmx.de>)
|
|
.SH "CREDITS"
|
|
.TP
|
|
Many thanks go to:
|
|
Julien Furgerot who lend me a Dell A920.
|
|
Robert Price, Dani Ele and Dalai Felinto for the time they spent recording
|
|
USB activity and testing the experimental version.
|