kopia lustrzana https://gitlab.com/sane-project/backends
				
				
				
			
		
			
				
	
	
		
			94 wiersze
		
	
	
		
			2.9 KiB
		
	
	
	
		
			Groff
		
	
	
			
		
		
	
	
			94 wiersze
		
	
	
		
			2.9 KiB
		
	
	
	
		
			Groff
		
	
	
.TH sane-coolscan 5 "4 July 2000" "@PACKAGEVERSION@" "SANE Scanner Access Now Easy"
 | 
						|
.IX sane-coolscan
 | 
						|
 | 
						|
.SH NAME
 | 
						|
sane-coolscan \- SANE backend for Nikon film-scanners
 | 
						|
 | 
						|
.SH ABOUT THIS FILE
 | 
						|
 | 
						|
This file is a short descripton of the coolscan-backend for sane! 
 | 
						|
 | 
						|
.SH DESCRIPTION
 | 
						|
 | 
						|
The
 | 
						|
.B sane-coolscan
 | 
						|
library implements a SANE backend that provides the interface to the following Nikon Coolscan Film scanners: Nikon LS20, LS30, LS1000, LS2000.
 | 
						|
 | 
						|
.B Even though the backend has worked for a number of people, there are still some problems, especially in combination with some SCSI card/drivers (AHA-1505/aha152x.o) and the autofocus command. You should consider this backend 'alpha' and be carefull when using it the first time.
 | 
						|
 | 
						|
.SH CONFIGURATION
 | 
						|
 | 
						|
The configuration file for this backend resides in 
 | 
						|
@CONFIGDIR@/coolscan.conf. 
 | 
						|
 | 
						|
Its contents is a list of device names that correspond to Nikon Coolscan scanners. Empty lines
 | 
						|
and lines starting with a hash mark (#) are ignored. A sample configuration file is
 | 
						|
shown below: 
 | 
						|
 | 
						|
 #scsi Vendor Model Type 
 | 
						|
 scsi Nikon * Scanner 
 | 
						|
 /dev/scanner 
 | 
						|
 | 
						|
The special device name must be a generic SCSI device or a symlink to such a device.
 | 
						|
To find out to which device your scanner is assigned and how you have to set the
 | 
						|
permissions of that device, have a look at sane-scsi. 
 | 
						|
 | 
						|
.SH SCSI ADAPTER TIPS
 | 
						|
 | 
						|
Some SCSI-adapters and low-level SCSI drivers do not work correctly with this backend and the
 | 
						|
Coolscan scanners. These systems hang when the autofocus command is send to the Scanner.
 | 
						|
To see a list of which card/driver combinations work or dont work have a look at:
 | 
						|
http://andreas.rick.free.fr/sane/autofocus.html.
 | 
						|
 | 
						|
 | 
						|
 | 
						|
.SH FILES
 | 
						|
 | 
						|
The backend configuration file:
 | 
						|
 @CONFIGDIR@/coolscan.conf. 
 | 
						|
 | 
						|
The static library implementing this backend:
 | 
						|
 @LIBDIR@/libsane-coolscan.a
 | 
						|
 | 
						|
The shared library implementing this backend:
 | 
						|
 @LIBDIR@/libsane-coolscan.so
 | 
						|
 (present on systems that support dynamic loading)
 | 
						|
 | 
						|
.SH ENVIRONMENT
 | 
						|
 | 
						|
.B SANE_DEBUG_COOLSCAN
 | 
						|
 If the library was compiled with debug support enabled, this environment
 | 
						|
variable controls the debug level for this backend. E.g., a value of 128
 | 
						|
requests all debug output to be printed. Smaller levels reduce verbosity:
 | 
						|
SANE_DEBUG_COOLSCAN values
 | 
						|
 | 
						|
Examples:
 | 
						|
 on bash:
 | 
						|
 export SANE_DEBUG_COOLSCAN=8
 | 
						|
 on csh
 | 
						|
 setenv SANE_DEBUG_COOLSCAN 8
 | 
						|
 | 
						|
.SH BUGS
 | 
						|
 | 
						|
 The autofocus command does not work with some SCSI card/driver combinations
 | 
						|
 The gamma table is not implemented for the LS1000 yet.
 | 
						|
 The dust-removal is not working yet
 | 
						|
 | 
						|
.SH SEE ALSO
 | 
						|
 | 
						|
 http://andreas.rick.free.fr/sane/ The homepage of this backend
 | 
						|
 http://www.sema.be/coolscan/  The original version of the coolscan backend by Didier
 | 
						|
 sane(7), sane\-scsi(5)
 | 
						|
 | 
						|
.SH THANKS TO
 | 
						|
 | 
						|
 Didier Carlier - For writing the original Coolscan backend (without it I would not have started this) 
 | 
						|
 Oliver.Rauch - For adapting xsane so quickly to the infrared stuff.
 | 
						|
 All the other people working on SANE.
 | 
						|
 | 
						|
.SH AUTHOR
 | 
						|
Andreas Rick
 | 
						|
 | 
						|
.SH EMAIL-CONTACT
 | 
						|
andreas.rick@free.fr
 |