.TH sane\-coolscan3 5 "11 Jul 2008"  "@PACKAGEVERSION@" "SANE Scanner Access Now Easy"
 | 
						|
.IX sane\-coolscan3
 | 
						|
.SH NAME
 | 
						|
sane\-coolscan3 \- SANE backend for Nikon Coolscan film scanners
 | 
						|
.SH DESCRIPTION
 | 
						|
The
 | 
						|
.B sane\-coolscan3
 | 
						|
library implements a SANE (Scanner Access Now Easy) backend that
 | 
						|
provides access to Nikon Coolscan film scanners.  Some functions of this 
 | 
						|
backend should be considered 
 | 
						|
.B beta-quality
 | 
						|
software. Most functions have been stable for a long time, but of 
 | 
						|
course new development can not and will not function properly from 
 | 
						|
the very first day.
 | 
						|
 | 
						|
.PP
 | 
						|
At present, the following scanners are known to work with this backend:
 | 
						|
.PP
 | 
						|
.RS
 | 
						|
.ft CR
 | 
						|
.nf
 | 
						|
Model:                       Connection Type
 | 
						|
---------------------------  -------------------
 | 
						|
LS-30 (Coolscan III)         SCSI
 | 
						|
LS-40 ED (Coolscan IV)       USB
 | 
						|
LS-50 ED (Coolscan V)        USB
 | 
						|
LS-2000                      SCSI
 | 
						|
LS-4000 ED                   IEEE 1394
 | 
						|
LS-8000 ED                   IEEE 1394
 | 
						|
.fi
 | 
						|
.ft R
 | 
						|
.RE
 | 
						|
 | 
						|
Please send mail to sane-devel@lists.alioth.debian.org to report successes 
 | 
						|
or failures.
 | 
						|
 | 
						|
.SH OPTIONS
 | 
						|
The options the backend supports can either be selected through command line 
 | 
						|
options to programs like scanimage or through GUI elements in xscanimage or xsane.
 | 
						|
 | 
						|
Valid command line options and their syntax can be listed by using 
 | 
						|
.RS
 | 
						|
scanimage \-\-help \-d coolscan3:<interface>:<device>
 | 
						|
.RE
 | 
						|
where <interface> and <device> specify the device in question, as in the
 | 
						|
configuration file (see next section). The \-d parameter and its argument
 | 
						|
can be omitted to obtain information on the first scanner identified. Use
 | 
						|
the command 
 | 
						|
.RS
 | 
						|
scanimage \-L
 | 
						|
.RE
 | 
						|
to list all devices recognized by your SANE installation.
 | 
						|
 | 
						|
The options should be fully described by the description or tooltips given by 
 | 
						|
frontend. Here is a description of some of the most important options, in the
 | 
						|
syntax with which they must be supplied to scanimage:
 | 
						|
.TP
 | 
						|
.I \-\-frame <n>
 | 
						|
This option specifies which frame to operate on, if a motorized film strip
 | 
						|
feeder or APS adapter are used. The frame number
 | 
						|
.I <n>
 | 
						|
ranges from 1 to the number of frames available, which is sensed each time
 | 
						|
the backend is initialized (usually each time you start the frontend).
 | 
						|
.TP
 | 
						|
.I \-\-subframe <x>
 | 
						|
This option shifts the scan window by the specified amount (default
 | 
						|
unit is mm).
 | 
						|
.TP
 | 
						|
.I \-\-infrared=yes/no
 | 
						|
If set to "yes", the scanner will read the infrared channel, thus allowing
 | 
						|
defect removal in software. The infrared image is read during a second scan,
 | 
						|
with no options altered. The backend must not be restarted between the scans. 
 | 
						|
If you use scanimage, perform a batch scan with batch\-count=2 to obtain the
 | 
						|
IR information.
 | 
						|
.TP
 | 
						|
.I \-\-depth <n>
 | 
						|
Here <n> can either be 8 or the maximum number of bits supported by the
 | 
						|
scanner (10, 12, or 14). It specifies whether or not the scanner reduces
 | 
						|
the scanned data to 8 bits before sending it to the backend. If 8 bits are
 | 
						|
used, some information and thus image quality is lost, but the amount of data
 | 
						|
is smaller compared to higher depths. Also, many imaging programs and image
 | 
						|
formats cannot handle depths greater than 8 bits.
 | 
						|
.TP
 | 
						|
.I \-\-autofocus
 | 
						|
Perform autofocus operation. Unless otherwise specified by the other options (
 | 
						|
.I \-\-focus\-on\-centre
 | 
						|
and friends), focusing is performed on the centre of the selected scan area.
 | 
						|
.TP
 | 
						|
.I \-\-ae\-wb
 | 
						|
.TP
 | 
						|
.I \-\-ae
 | 
						|
Perform a pre-scan to calculate exposure values automatically.
 | 
						|
.I \-\-ae\-wb
 | 
						|
will maintain the white balance, while
 | 
						|
.I \-\-ae
 | 
						|
will adjust each channel separately.
 | 
						|
.TP
 | 
						|
.I \-\-exposure
 | 
						|
Multiply all exposure times with this value. This allows exposure
 | 
						|
correction without modifying white balance.
 | 
						|
.TP
 | 
						|
.I \-\-load
 | 
						|
Load the next slide when using the slide loader.
 | 
						|
.TP
 | 
						|
.I \-\-eject
 | 
						|
Eject the film strip or mounted slide when using the slide loader.
 | 
						|
.TP
 | 
						|
.I \-\-reset
 | 
						|
Reset scanner. The scanner will perform the same action as when power is
 | 
						|
turned on: it will eject the film strip and calibrate itself. Use this
 | 
						|
whenever the scanner refuses to load a film strip properly, as a result of
 | 
						|
which 
 | 
						|
.I \-\-eject
 | 
						|
does not work.
 | 
						|
 | 
						|
.SH CONFIGURATION FILE
 | 
						|
The configuration file @CONFIGDIR@/coolscan3.conf specifies the device(s)
 | 
						|
that the backend will use. Owing to the nature of the supported connection
 | 
						|
types SCSI, USB, and IEEE 1394, the default configuration file supplied with
 | 
						|
the SANE distribution should work without being edited.
 | 
						|
 | 
						|
Each line in the configuration file is either of the following, where all
 | 
						|
entries are case-sensitive:
 | 
						|
.TP
 | 
						|
.I blank or starting with a '#' character
 | 
						|
These lines are ignored, thus '#' can be used to include comments.
 | 
						|
.TP
 | 
						|
.I containing only the word """auto"""
 | 
						|
This instructs the backend to probe for a scanner by scanning the buses for 
 | 
						|
devices with know identifiers. This is the action taken when no
 | 
						|
configuration file is present.
 | 
						|
.TP
 | 
						|
.I a line of the form <interface>:<device>
 | 
						|
Here <interface> can be one of "scsi" or "usb", and <device> is the device
 | 
						|
file of the scanner. Note that IEEE 1394 devices are handled by the SBP-2
 | 
						|
module in the kernel and appear to SANE as SCSI devices.
 | 
						|
 | 
						|
.SH FILES
 | 
						|
.TP
 | 
						|
.I @LIBDIR@/libsane\-coolscan3.a
 | 
						|
The static library implementing this backend.
 | 
						|
.TP
 | 
						|
.I @LIBDIR@/libsane\-coolscan3.so
 | 
						|
The shared library implementing this backend (present on systems that
 | 
						|
support dynamic loading).
 | 
						|
.TP
 | 
						|
.I @CONFIGDIR@/coolscan3.conf
 | 
						|
Configuration file for this backend, read each time the backend is
 | 
						|
initialized.
 | 
						|
 | 
						|
.SH ENVIRONMENT
 | 
						|
.TP
 | 
						|
.B SANE_DEBUG_COOLSCAN3
 | 
						|
If the library was compiled with debug support enabled, this
 | 
						|
environment variable controls the debug level for this backend.  E.g.,
 | 
						|
a value of 128 requests all debug output to be printed.  Smaller
 | 
						|
levels reduce verbosity.
 | 
						|
 | 
						|
.SH "SEE ALSO"
 | 
						|
sane\-scsi(5), sane\-usb(5), scanimage(1), xscanimage(1), xsane(1)
 | 
						|
 | 
						|
.SH BUGS
 | 
						|
Currently, the SANE protocol does not allow automatically updating options
 | 
						|
whenever the hardware changes. Thus the number of choices for the
 | 
						|
.B \-\-frame
 | 
						|
option will be fixed when the backend is initialized (usually when the user
 | 
						|
runs the frontend). In particular, if there is no film strip in the
 | 
						|
automatic film strip feeder when the backend is initialized, the frame option
 | 
						|
will not appear at all. Also, restarting the frontend after swapping film
 | 
						|
adapters is strongly recommended.
 | 
						|
 | 
						|
Linux kernels prior to 2.4.19 had a patch that truncated INQUIRY data
 | 
						|
from IEEE 1394 scanners to 36 bytes, discarding vital information
 | 
						|
about the scanner. The IEEE 1394 models therefore only work with
 | 
						|
2.4.19 or later.
 | 
						|
 | 
						|
No real bugs currently known, please report any to the SANE developers' list.
 | 
						|
 | 
						|
.SH AUTHORS
 | 
						|
coolscan3 written by A. Zummo (a.zummo@towertech.it), based heavily on
 | 
						|
coolscan2 written by Andr\['a]s Major (andras@users.sourceforge.net). 
 | 
						|
 |