sane-project-backends/doc/sane-gt68xx.man

269 wiersze
8.4 KiB
Groff

.TH sane-gt68xx 5 "23 Dec 2002" "@PACKAGEVERSION@" "SANE Scanner Access Now Easy"
.IX sane-gt68xx
.SH NAME
sane-gt68xx \- SANE backend for GT-68XX based USB flatbed scanners
.SH DESCRIPTION
The
.B sane-gt68xx
library implements a SANE (Scanner Access Now Easy) backend that provides
access to USB flatbed scanners based on the Grandtech GT-6801 and GT-6816
chips. At present, the following scanners are known to work with this
backend:
.PP
.RS
Artec Ultima 2000 (only product 0x4002)
.br
Boeder SmartScan Slim Edition
.br
Lexmark X70
.br
Medion/Lifetec/Tevion/Cytron MD/LT 9385
.br
Medion/Lifetec/Tevion LT 9452
.br
Medion/Lifetec/Tevion MD 9458
.br
Mustek BearPaw 1200 CS
.br
Mustek BearPaw 1200 CU (Plus)
.br
Mustek BearPaw 1200 TA
.br
Mustek BearPaw 2400 CU (Plus)
.br
Mustek BearPaw 2400 TA (Plus)
.br
Mustek ScanExpress A3 USB
.br
Mustek ScanExpress 1200 UB Plus
.br
Mustek ScanExpress 2400 USB
.br
Packard Bell Diamond 1200
.br
Plustek OpticPro 1248U
.br
Trust Compact Scan USB 19200
.br
Trust Flat Scan USB 19200
.RE
.PP
More details can be found on the gt68xx backend homepage
.IR http://www.meier-geinitz.de/sane/gt68xx/ .
.PP
The Artec E+ 48U and its clones are supported by the artec_eplus48u backend, see
.BR sane-artec_eplus48u (5)
for details.
.PP
This is BETA software. Especially if you test new or untested scanners, keep
your hand at the scanner's plug and unplug it, if the head bumps at the end of
the scan area.
.PP
If you own a scanner other than the ones listed above that works with this
backend, please let me know this by sending the scanner's exact model name and
the USB vendor and device ids (e.g. from
.IR /proc/bus/usb/devices ,
.I sane-find-scanner
or syslog) to me. Even if the scanner's name is only slightly different from
the models mentioned above, please let me know.
.PP
.SH KERNEL ISSUES
If libusb-0.1.6 or later is installed, this section can be skipped. The
scanner should be found by sane-find-scanner without further actions. For
setting permissions and general USB information looks at
.BR sane-usb (5).
.PP
The scanners based on the GT-6816 (Mustek BearPaw TA and BearPaw Plus models,
the Packard Bell and the Lexmark scanner) need a Linux kernel 2.4.12 or newer.
Recent 2.2 kernels may also work, but I haven't tested them. Older kernels or
other operating systems won't work. Use libusb instead.
.PP
The scanners based on the GT-6801 (all other scanners) need an updated kernel
scanner module that is not yet included in the official kernel code. It can
be downloaded from the gt68xx backend homepage. There is also an installation
instruction.
.SH FIRMWARE FILE
You need a firmware file for your scanner. That's a small file containing
software that will be uploaded to the scanner's memory. It's usually named
*.usb, e.g.
.IR PS1fw.usb .
It comes on the installation CD that was provided by the manufacturer, but it
may be packaged together with the installation program in an .exe file. For
Mustek scanners, the file can be dowloaded from the gt68xx backend
homepage. For other scanners, check the CD for .usb files. If everything else
fails, you must install the Windows driver and get the firmware from there
(usually in the
.I windows/system
or
.I system32
directories). Put that firmware file into
.IR @DATADIR@/sane/gt68xx/ .
.SH CONFIGURATION
The contents of the
.I gt68xx.conf
file is a list of usb lines containing vendor and product ids that correspond
to USB scanners. The file can also contain option lines. Empty lines and
lines starting with a hash mark (#) are ignored. The scanners are
autodetected by
.B usb vendor_id product_id
statements which are already included into
.IR gt68xx.conf .
"vendor_id" and "product_id" are hexadecimal numbers that identfy the
scanner.
.PP
The
.BR override ,
.BR firmware ,
.BR vendor ,
.BR model ,
and
.B afe
options must be placed after the
.B usb
line they refer to.
.PP
Option
.B override
is used to override the default model parameters. That's necessary for some
scanners that use the same vendor/product ids but are different. For these
scanners there are already commented out override lines in the configuration
file.
.B override "mustek-scanexpress-1200-ub-plus"
is necessary for the Mustek Scanexpress 1200 UB Plus, the
Medion/Lifetec/Tevion LT 9452, and the Trust Compact Scan USB 19200.
.B override "artec-ultima-2000"
is used for the Artec Ultima 2000, the Boeder SmartScan Slim Edition, the
Medion/ Lifetec/ Tevion/ Cytron MD/LT 9385, the Medion/ Lifetec/ Tevion MD
9458, and the Trust Flat Scan USB 19200.
.B override "mustek-bearpaw-2400-cu"
is necessary for the Mustek BearPaw 2400 CU. The
.B override
option must be the first one after the
.B usb
line.
.PP
Option
.B firmware
selects the name and path of the firmware file. It's only necessary if the
default (or override) doesn't work. The default firmware directory is
.IR @DATADIR@/sane/gt68xx/ .
You may need to create this directory. If you want to place the firmware files
at a different path, use a
.B firmware
line.
.PP
The
.B vendor
and
.B model
options are not absolutely necessary but for convenience. Quite a lot of
scanners from different manufacturers share the same vendor/product ids so you
can set the "correct" name here.
.PP
The
.B afe
option allows to set custom offset and gain values for the Analog FrontEnd of
the scanner. This option can be either used to select the AFE values if
automatic coarse calibration is disabled, or to make automatic coarse
calibration faster. For the latter usage, enable debug level 3 (see below),
scan an image and look for debug line string with "afe". Copy this line to
.IR gt68xx.conf .
The option has six parameters: res offset, red gain, green offset, green gain,
blue offset, and blue gain.
.PP
A sample configuration file is shown below:
.PP
.RS
usb 0x05d8 0x4002
.br
override "mustek-scanexpress-1200-ub-plus"
.br
firmware "/opt/gt68xx/SBfw.usb"
.br
vendor "Trust"
.br
product "Compact Scan USB 19200"
.br
afe 0x20 0x02 0x22 0x03 0x1f 0x04
.RE
.SH FILES
.TP
.I @CONFIGDIR@/gt68xx.conf
The backend configuration file (see also description of
.B SANE_CONFIG_DIR
below).
.TP
.I @LIBDIR@/libsane-gt68xx.a
The static library implementing this backend.
.TP
.I @LIBDIR@/libsane-gt68xx.so
The shared library implementing this backend (present on systems that
support dynamic loading).
.SH ENVIRONMENT
.TP
.B SANE_CONFIG_DIR
This environment variable specifies the list of directories that may
contain the configuration file. Under UNIX, the directories are
separated by a colon (`:'), under OS/2, they are separated by a
semi-colon (`;'). If this variable is not set, the configuration file
is searched in two default directories: first, the current working
directory (".") and then in @CONFIGDIR@. If the value of the
environment variable ends with the directory separator character, then
the default directories are searched after the explicitly specified
directories. For example, setting
.B SANE_CONFIG_DIR
to "/tmp/config:" would result in directories "tmp/config", ".", and
"@CONFIGDIR@" being searched (in this order).
.TP
.B SANE_DEBUG_GT68XX
If the library was compiled with debug support enabled, this
environment variable controls the debug level for this backend. Higher
debug levels increase the verbosity of the output.
Example:
export SANE_DEBUG_GT68XX=4
.SH "SEE ALSO"
.BR sane (7),
.BR sane-usb (5),
.BR sane-artec_eplus48u (5)
.BR sane-plustek (5),
.BR sane-mustek_usb (5),
.BR sane-mustek (5),
.BR sane-mustek_pp (5)
.br
.I @DOCDIR@/gt68xx/gt68xx.CHANGES
.br
.I http://www.meier-geinitz.de/sane/gt68xx
.SH AUTHOR
Henning Meier-Geinitz <henning@meier-geinitz.de>
.br
The original gt68xx driver was written by Sergey Vlasov, Andreas Nowack, and
David Stevenson. Thanks for sending patches and answering questions to them
and all the other contributors.
.SH BUGS
Currently scanning seems to only work reliably under Linux. With FreeBSD,
NetBSD and OpenBSD scanning works only once. Then either the scanner has to be
replugged or even a reboot is necessary. That's most probably a kernel issue.
.PP
The first few lines of the image are garbage for the 2400 TA
Plus.
.PP
The images are too dark for some scanners, especially in TA mode. Maybe
add a gamma option?
.PP
Interpolation should be used instead of just copying data, when the X- and
Y-resolution differ.
.PP
Support for buttons is missing.
.PP
More detailed bug information is available at the gt68xx backend homepage
.IR http://www.meier-geinitz.de/sane/gt68xx .
Please contact me if you find a bug or missing feature:
<henning@meier-geinitz.de>