kopia lustrzana https://gitlab.com/sane-project/backends
184 wiersze
6.5 KiB
Groff
184 wiersze
6.5 KiB
Groff
.TH sane-coolscan2 5 "22/08/2002" "@PACKAGEVERSION@" "SANE Scanner Access Now Easy"
|
||
.IX sane-coolscan2
|
||
.SH NAME
|
||
sane-coolscan2 \- SANE backend for Nikon Coolscan film scanners
|
||
.SH DESCRIPTION
|
||
The
|
||
.sane-coolscan2
|
||
library implements a SANE (Scanner Access Now Easy) backend that
|
||
provides access to Nikon Coolscan film scanners. Some functions of this
|
||
backend should be considered
|
||
.B beta-quality
|
||
software. Most functions have been stable for a long time, but of
|
||
course new development can not and will not function properly from
|
||
the very first day. Please report any strange behaviour to the
|
||
maintainer of the backend.
|
||
|
||
.PP
|
||
At present, the following scanners are known to work with this backend:
|
||
.PP
|
||
.RS
|
||
Model: Connection Type
|
||
.br
|
||
--------------------------- -------------------
|
||
.br
|
||
LS-30 (Coolscan III) SCSI
|
||
.br
|
||
LS-2000 SCSI
|
||
.br
|
||
LS-40 ED (Coolscan IV) USB
|
||
.br
|
||
LS-4000 ED IEEE 1394
|
||
.br
|
||
LS-8000 ED IEEE 1394
|
||
.RE
|
||
|
||
Please send mail to the backend author (andras@users.sourceforge.net) to
|
||
report successes or failures.
|
||
|
||
.SH OPTIONS
|
||
The options the backend supports can either be selected through command line
|
||
options to programs like scanimage or through GUI elements in xscanimage or xsane.
|
||
|
||
Valid command line options and their syntax can be listed by using
|
||
.RS
|
||
scanimage --help -d coolscan2:<interface>:<device>
|
||
.RE
|
||
where <interface> and <device> specify the device in question, as in the
|
||
configuration file (see next section). The "-d" parameter and its argument
|
||
can be omitted to obtain information on the first scanner identified. Use
|
||
the command
|
||
.RS
|
||
scanimage -L
|
||
.RE
|
||
to list all devices recognized by your SANE installation.
|
||
|
||
The options should be fully described by the description or tooltips given by
|
||
frontend. Here is a description of some of the most important options, in the
|
||
syntax with which they must be supplied to scanimage:
|
||
.TP
|
||
.I --frame <n>
|
||
This option specifies which frame to operate on, if a motorized film strip
|
||
feeder or APS adapter are used. The frame number
|
||
.I <n>
|
||
ranges from 1 to the number of frames available, which is sensed each time
|
||
the backend is initialized (usually each time you start the frontend).
|
||
.TP
|
||
.I --subframe <x>
|
||
This option shifts the scan window by the specified amount (default
|
||
unit is mm).
|
||
.I --infrared=yes/no
|
||
If set to "yes", the scanner will read the infrared channel, thus allowing
|
||
defect removal in software. The infrared image is read during a second scan,
|
||
with no options altered. The backend must not be restarted between the scans.
|
||
If you use scanimage, perform a batch scan with batch-count=2 to obtain the
|
||
IR information.
|
||
.TP
|
||
.I --depth <n>
|
||
Here <n> can either be 8 or the maximum number of bits supported by the
|
||
scanner (10, 12, or 14). It specifies whether or not the scanner reduces
|
||
the scanned data to 8 bits before sending it to the backend. If 8 bits are
|
||
used, some information and thus image quality is lost, but the amount of data
|
||
is smaller compared to higher depths. Also, many imaging programs and image
|
||
formats cannot handle depths greater than 8 bits.
|
||
.TP
|
||
.I --autofocus
|
||
Perform autofocus operation. Unless otherwise specified by the other options (
|
||
.I --focus-on-centre
|
||
and friends), focusing is performed on the centre of the selected scan area.
|
||
.TP
|
||
.I --ae-wb
|
||
.TP
|
||
.I --ae
|
||
Perform a pre-scan to calculate exposure values automatically.
|
||
.I --ae-wb
|
||
will maintain the white balance, while
|
||
.I --ae
|
||
will adjust each channel separately.
|
||
.TP
|
||
.I --exposure
|
||
Multiply all exposure times with this value. This allows exposure
|
||
correction without modifying white balance.
|
||
.TP
|
||
.I --load
|
||
Load the next slide when using the slide loader.
|
||
.TP
|
||
.I --eject
|
||
Eject the film strip or mounted slide when using the slide loader.
|
||
.TP
|
||
.I --reset
|
||
Reset scanner. The scanner will perform the same action as when power is
|
||
turned on: it will eject the film strip and calibrate itself. Use this
|
||
whenever the scanner refuses to load a film strip properly, as a result of
|
||
which
|
||
.I --eject
|
||
does not work.
|
||
|
||
.SH CONFIGURATION FILE
|
||
The configuration file @CONFIGDIR@/coolscan2.conf specifies the device(s)
|
||
that the backend will use. Owing to the nature of the supported connection
|
||
types SCSI, USB, and IEEE 1394, the default configuration file supplied with
|
||
the SANE distribution should work without being edited.
|
||
|
||
Each line in the configuration file is either of the following, where all
|
||
entries are case-sensitive:
|
||
.TP
|
||
.I blank or starting with a '#' character
|
||
These lines are ignored, thus '#' can be used to include comments.
|
||
.TP
|
||
.I containing only the word """auto"""
|
||
This instructs the backend to probe for a scanner by scanning the buses for
|
||
devices with know identifiers. This is the action taken when no
|
||
configuration file is present.
|
||
.TP
|
||
.I a line of the form <interface>:<device>
|
||
Here <interface> can be one of "scsi" or "usb", and <device> is the device
|
||
file of the scanner. Note that IEEE 1394 devices are handled by the SBP-2
|
||
module in the kernel and appear to SANE as SCSI devices.
|
||
|
||
.SH FILES
|
||
.TP
|
||
.I @LIBDIR@/libsane-coolscan2.a
|
||
The static library implementing this backend.
|
||
.TP
|
||
.I @LIBDIR@/libsane-coolscan2.so
|
||
The shared library implementing this backend (present on systems that
|
||
support dynamic loading).
|
||
.TP
|
||
.I @CONFIGDIR@/coolscan2.conf
|
||
Configuration file for this backend, read each time the backend is
|
||
initialized.
|
||
|
||
.SH ENVIRONMENT
|
||
.TP
|
||
.B SANE_DEBUG_COOLSCAN2
|
||
If the library was compiled with debug support enabled, this
|
||
environment variable controls the debug level for this backend. E.g.,
|
||
a value of 128 requests all debug output to be printed. Smaller
|
||
levels reduce verbosity.
|
||
|
||
.SH "SEE ALSO"
|
||
sane\-scsi(5), sane\-usb(5), scanimage(1), xscanimage(1), xsane(1)
|
||
|
||
.SH BUGS
|
||
Currently, the SANE protocol does not allow automatically updating options
|
||
whenever the hardware changes. Thus the number of choices for the
|
||
.B --frame
|
||
option will be fixed when the backend is initialized (usually when the user
|
||
runs the frontend). In particular, if there is no film strip in the
|
||
automatic film strip feeder when the backend is initialized, the frame option
|
||
will not appear at all. Also, restarting the frontend after swapping film
|
||
adapters is strongly recommended.
|
||
|
||
Linux kernels prior to 2.4.19 had a patch that truncated INQUIRY data
|
||
from IEEE 1394 scanners to 36 bytes, discarding vital information
|
||
about the scanner. The IEEE 1394 models therefore only work with
|
||
2.4.19 or later.
|
||
|
||
No real bugs currently known, please report any to the backend maintainer
|
||
or the SANE developers' email list.
|
||
|
||
.SH AUTHORS
|
||
The backend is written and maintained by Andr<64>s Major
|
||
(andras@users.sourceforge.net).
|