| .TH sane\-coolscan 5 "13 Jul 2008" "@PACKAGEVERSION@" "SANE Scanner Access Now Easy"
 | |
| .IX sane\-coolscan
 | |
| 
 | |
| .SH NAME
 | |
| sane\-coolscan \- SANE backend for Nikon film-scanners
 | |
| 
 | |
| .SH ABOUT THIS FILE
 | |
| 
 | |
| This file is a short description of the coolscan backend for
 | |
| .BR SANE .
 | |
| 
 | |
| .SH DESCRIPTION
 | |
| 
 | |
| The
 | |
| .B sane\-coolscan
 | |
| library implements a SANE backend that provides the interface to the following Nikon
 | |
| Coolscan Film scanners: Nikon LS20, LS30, LS1000, LS2000.
 | |
| 
 | |
| .B Even though the backend has worked for a number of people, there are still some
 | |
| problems, especially in combination with some SCSI card/drivers (AHA-1505/aha152x.o)
 | |
| and the autofocus command.
 | |
| You should consider this backend 'alpha' and be careful when using it the first time.
 | |
| 
 | |
| .SH CONFIGURATION
 | |
| 
 | |
| The configuration file for this backend resides in
 | |
| .IR @CONFIGDIR@/coolscan.conf .
 | |
| 
 | |
| Its content is a list of device names that correspond to Nikon Coolscan scanners. Empty lines
 | |
| and lines starting with a hash mark (#) are ignored. A sample configuration file is
 | |
| shown below:
 | |
| 
 | |
| .nf
 | |
|  #scsi Vendor Model Type
 | |
|  scsi Nikon * Scanner
 | |
|  /dev/scanner
 | |
| .fi
 | |
| 
 | |
| The special device name must be a generic SCSI device or a symlink to such a device.
 | |
| To find out to which device your scanner is assigned and how you can set the
 | |
| permissions of that device, have a look at
 | |
| .BR sane\-scsi (5).
 | |
| 
 | |
| .SH SCSI ADAPTER TIPS
 | |
| 
 | |
| Some SCSI-adapters and low-level SCSI drivers do not work correctly with this backend and the
 | |
| Coolscan scanners. These systems hang when the autofocus command is send to the Scanner.
 | |
| To see a list of which card/driver combinations work or don't work have a look at:
 | |
| .I http://andreas.rick.free.fr/sane/autofocus.html.
 | |
| 
 | |
| .SH FILES
 | |
| .TP
 | |
| The backend configuration file:
 | |
| .I @CONFIGDIR@/coolscan.conf
 | |
| .TP
 | |
| The static library implementing this backend:
 | |
| .I @LIBDIR@/libsane\-coolscan.a
 | |
| .TP
 | |
| The shared library implementing this backend:
 | |
| .I @LIBDIR@/libsane\-coolscan.so
 | |
| (present on systems that support dynamic loading)
 | |
| 
 | |
| .SH ENVIRONMENT
 | |
| 
 | |
| .TP
 | |
| .B SANE_DEBUG_COOLSCAN
 | |
| If the library was compiled with debug support enabled, this environment
 | |
| variable controls the debug level for this backend. E.g., a value of 128
 | |
| requests all debug output to be printed. Smaller levels reduce verbosity.
 | |
| 
 | |
| Examples:
 | |
| 
 | |
| On bash:
 | |
| .br
 | |
| export SANE_DEBUG_COOLSCAN=8
 | |
| 
 | |
| On csh:
 | |
| .br
 | |
| setenv SANE_DEBUG_COOLSCAN 8
 | |
| 
 | |
| .SH BUGS
 | |
| 
 | |
| The autofocus command does not work with some SCSI card/driver combinations.
 | |
| .PP
 | |
| The gamma table is not implemented for the LS1000 yet.
 | |
| .PP
 | |
| The dust-removal is not working yet.
 | |
| 
 | |
| .SH SEE ALSO
 | |
| .BR sane (7),
 | |
| .BR sane\-scsi (5)
 | |
| 
 | |
| .TP
 | |
| .I http://andreas.rick.free.fr/sane/
 | |
| The homepage of this backend.
 | |
| .TP
 | |
| .I http://www.sema.be/coolscan/
 | |
| The original version of the coolscan backend by Didier.
 | |
| 
 | |
| .SH THANKS TO
 | |
| Didier Carlier \- For writing the original Coolscan backend (without it I would not have started this).
 | |
| .PP
 | |
| Oliver Rauch \- For adapting xsane so quickly to the infrared stuff.
 | |
| .PP
 | |
| All the other people working on SANE.
 | |
| 
 | |
| .SH AUTHOR
 | |
| Andreas Rick
 | |
| 
 | |
| .SH EMAIL-CONTACT
 | |
| .I andreas.rick@free.fr
 |