| /* sane - Scanner Access Now Easy.
 | |
| 
 | |
|    Copyright (C) 2019 Povilas Kanapickas <povilas@radix.lt>
 | |
| 
 | |
|    This file is part of the SANE package.
 | |
| 
 | |
|    This program is free software; you can redistribute it and/or
 | |
|    modify it under the terms of the GNU General Public License as
 | |
|    published by the Free Software Foundation; either version 2 of the
 | |
|    License, or (at your option) any later version.
 | |
| 
 | |
|    This program is distributed in the hope that it will be useful, but
 | |
|    WITHOUT ANY WARRANTY; without even the implied warranty of
 | |
|    MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE.  See the GNU
 | |
|    General Public License for more details.
 | |
| 
 | |
|    You should have received a copy of the GNU General Public License
 | |
|    along with this program; if not, write to the Free Software
 | |
|    Foundation, Inc., 59 Temple Place - Suite 330, Boston,
 | |
|    MA 02111-1307, USA.
 | |
| 
 | |
|    As a special exception, the authors of SANE give permission for
 | |
|    additional uses of the libraries contained in this release of SANE.
 | |
| 
 | |
|    The exception is that, if you link a SANE library with other files
 | |
|    to produce an executable, this does not by itself cause the
 | |
|    resulting executable to be covered by the GNU General Public
 | |
|    License.  Your use of that executable is in no way restricted on
 | |
|    account of linking the SANE library code into it.
 | |
| 
 | |
|    This exception does not, however, invalidate any other reasons why
 | |
|    the executable file might be covered by the GNU General Public
 | |
|    License.
 | |
| 
 | |
|    If you submit changes to SANE to the maintainers to be included in
 | |
|    a subsequent release, you agree by submitting the changes that
 | |
|    those changes may be distributed with this exception intact.
 | |
| 
 | |
|    If you write modifications of your own for SANE, it is your choice
 | |
|    whether to permit this exception to apply to your modifications.
 | |
|    If you do not wish that, delete this exception notice.
 | |
| */
 | |
| 
 | |
| #ifndef BACKEND_GENESYS_DEVICE_H
 | |
| #define BACKEND_GENESYS_DEVICE_H
 | |
| 
 | |
| #include "calibration.h"
 | |
| #include "command_set.h"
 | |
| #include "buffer.h"
 | |
| #include "enums.h"
 | |
| #include "image_pipeline.h"
 | |
| #include "motor.h"
 | |
| #include "settings.h"
 | |
| #include "sensor.h"
 | |
| #include "register.h"
 | |
| #include "usb_device.h"
 | |
| #include "scanner_interface.h"
 | |
| #include "utilities.h"
 | |
| #include <vector>
 | |
| 
 | |
| namespace genesys {
 | |
| 
 | |
| struct Genesys_Gpo
 | |
| {
 | |
|     Genesys_Gpo() = default;
 | |
| 
 | |
|     // Genesys_Gpo
 | |
|     GpioId id = GpioId::UNKNOWN;
 | |
| 
 | |
|     /*  GL646 and possibly others:
 | |
|         - have the value registers at 0x66 and 0x67
 | |
|         - have the enable registers at 0x68 and 0x69
 | |
| 
 | |
|         GL841, GL842, GL843, GL846, GL848 and possibly others:
 | |
|         - have the value registers at 0x6c and 0x6d.
 | |
|         - have the enable registers at 0x6e and 0x6f.
 | |
|     */
 | |
|     GenesysRegisterSettingSet regs;
 | |
| };
 | |
| 
 | |
| struct MemoryLayout
 | |
| {
 | |
|     // This is used on GL845, GL846, GL847 and GL124 which have special registers to define the
 | |
|     // memory layout
 | |
|     MemoryLayout() = default;
 | |
| 
 | |
|     ValueFilter<ModelId> models;
 | |
| 
 | |
|     GenesysRegisterSettingSet regs;
 | |
| };
 | |
| 
 | |
| struct MethodResolutions
 | |
| {
 | |
|     std::vector<ScanMethod> methods;
 | |
|     std::vector<unsigned> resolutions_x;
 | |
|     std::vector<unsigned> resolutions_y;
 | |
| 
 | |
|     unsigned get_min_resolution_x() const
 | |
|     {
 | |
|         return *std::min_element(resolutions_x.begin(), resolutions_x.end());
 | |
|     }
 | |
| 
 | |
|     unsigned get_nearest_resolution_x(unsigned resolution) const
 | |
|     {
 | |
|         return *std::min_element(resolutions_x.begin(), resolutions_x.end(),
 | |
|                                  [&](unsigned lhs, unsigned rhs)
 | |
|         {
 | |
|             return std::abs(static_cast<int>(lhs) - static_cast<int>(resolution)) <
 | |
|                      std::abs(static_cast<int>(rhs) - static_cast<int>(resolution));
 | |
|         });
 | |
|     }
 | |
| 
 | |
|     unsigned get_min_resolution_y() const
 | |
|     {
 | |
|         return *std::min_element(resolutions_y.begin(), resolutions_y.end());
 | |
|     }
 | |
| 
 | |
|     std::vector<unsigned> get_resolutions() const;
 | |
| };
 | |
| 
 | |
| /** @brief structure to describe a scanner model
 | |
|  * This structure describes a model. It is composed of information on the
 | |
|  * sensor, the motor, scanner geometry and flags to drive operation.
 | |
|  */
 | |
| struct Genesys_Model
 | |
| {
 | |
|     Genesys_Model() = default;
 | |
| 
 | |
|     const char* name = nullptr;
 | |
|     const char* vendor = nullptr;
 | |
|     const char* model = nullptr;
 | |
|     ModelId model_id = ModelId::UNKNOWN;
 | |
| 
 | |
|     AsicType asic_type = AsicType::UNKNOWN;
 | |
| 
 | |
|     // possible x and y resolutions for each method supported by the scanner
 | |
|     std::vector<MethodResolutions> resolutions;
 | |
| 
 | |
|     // possible depths in gray mode
 | |
|     std::vector<unsigned> bpp_gray_values;
 | |
|     // possible depths in color mode
 | |
|     std::vector<unsigned> bpp_color_values;
 | |
| 
 | |
|     // the default scanning method. This is used when moving the head for example
 | |
|     ScanMethod default_method = ScanMethod::FLATBED;
 | |
| 
 | |
|     // All offsets below are with respect to the sensor home position
 | |
| 
 | |
|     // Start of scan area in mm
 | |
|     float x_offset = 0;
 | |
| 
 | |
|     // Start of scan area in mm (Amount of feeding needed to get to the medium)
 | |
|     float y_offset = 0;
 | |
| 
 | |
|     // Size of scan area in mm
 | |
|     float x_size = 0;
 | |
| 
 | |
|     // Size of scan area in mm
 | |
|     float y_size = 0;
 | |
| 
 | |
|     // Start of white strip in mm for scanners that use separate dark and white shading calibration.
 | |
|     float y_offset_calib_white = 0;
 | |
| 
 | |
|     // The size of the scan area that is used to acquire shading data in mm
 | |
|     float y_size_calib_mm = 0;
 | |
| 
 | |
|     // Start of the black/white strip in mm for scanners that use unified dark and white shading
 | |
|     // calibration.
 | |
|     float y_offset_calib_dark_white_mm = 0;
 | |
| 
 | |
|     // The size of the scan area that is used to acquire dark/white shading data in mm
 | |
|     float y_size_calib_dark_white_mm = 0;
 | |
| 
 | |
|     // The width of the scan area that is used to acquire shading data
 | |
|     float x_size_calib_mm = 0;
 | |
| 
 | |
|     // Start of black mark in mm
 | |
|     float x_offset_calib_black = 0;
 | |
| 
 | |
|     // Start of scan area in transparency mode in mm
 | |
|     float x_offset_ta = 0;
 | |
| 
 | |
|     // Start of scan area in transparency mode in mm
 | |
|     float y_offset_ta = 0;
 | |
| 
 | |
|     // Size of scan area in transparency mode in mm
 | |
|     float x_size_ta = 0;
 | |
| 
 | |
|     // Size of scan area in transparency mode in mm
 | |
|     float y_size_ta = 0;
 | |
| 
 | |
|     // The position of the sensor when it's aligned with the lamp for transparency scanning
 | |
|     float y_offset_sensor_to_ta = 0;
 | |
| 
 | |
|     // Start of white strip in transparency mode in mm
 | |
|     float y_offset_calib_white_ta = 0;
 | |
| 
 | |
|     // Start of black strip in transparency mode in mm
 | |
|     float y_offset_calib_black_ta = 0;
 | |
| 
 | |
|     // The size of the scan area that is used to acquire shading data in transparency mode in mm
 | |
|     float y_size_calib_ta_mm = 0;
 | |
| 
 | |
|     // Size of scan area after paper sensor stop sensing document in mm
 | |
|     float post_scan = 0;
 | |
| 
 | |
|     // Amount of feeding needed to eject document after finishing scanning in mm
 | |
|     float eject_feed = 0;
 | |
| 
 | |
|     // Line-distance correction (in pixel at motor base_ydpi) for CCD scanners
 | |
|     SANE_Int ld_shift_r = 0;
 | |
|     SANE_Int ld_shift_g = 0;
 | |
|     SANE_Int ld_shift_b = 0;
 | |
| 
 | |
|     // Order of the CCD/CIS colors
 | |
|     ColorOrder line_mode_color_order = ColorOrder::RGB;
 | |
| 
 | |
|     // Is this a CIS or CCD scanner?
 | |
|     bool is_cis = false;
 | |
| 
 | |
|     // Is this sheetfed scanner?
 | |
|     bool is_sheetfed = false;
 | |
| 
 | |
|     // sensor type
 | |
|     SensorId sensor_id = SensorId::UNKNOWN;
 | |
|     // Analog-Digital converter type
 | |
|     AdcId adc_id = AdcId::UNKNOWN;
 | |
|     // General purpose output type
 | |
|     GpioId gpio_id = GpioId::UNKNOWN;
 | |
|     // stepper motor type
 | |
|     MotorId motor_id = MotorId::UNKNOWN;
 | |
| 
 | |
|     // Which customizations are needed for this scanner?
 | |
|     ModelFlag flags = ModelFlag::NONE;
 | |
| 
 | |
|     // Button flags, described existing buttons for the model
 | |
|     SANE_Word buttons = 0;
 | |
| 
 | |
|     // how many lines are used to search start position
 | |
|     SANE_Int search_lines = 0;
 | |
| 
 | |
|     // returns nullptr if method is not supported
 | |
|     const MethodResolutions* get_resolution_settings_ptr(ScanMethod method) const;
 | |
| 
 | |
|     // throws if method is not supported
 | |
|     const MethodResolutions& get_resolution_settings(ScanMethod method) const;
 | |
| 
 | |
|     std::vector<unsigned> get_resolutions(ScanMethod method) const;
 | |
| 
 | |
|     bool has_method(ScanMethod method) const;
 | |
| };
 | |
| 
 | |
| /**
 | |
|  * Describes the current device status for the backend
 | |
|  * session. This should be more accurately called
 | |
|  * Genesys_Session .
 | |
|  */
 | |
| struct Genesys_Device
 | |
| {
 | |
|     Genesys_Device() = default;
 | |
|     ~Genesys_Device();
 | |
| 
 | |
|     using Calibration = std::vector<Genesys_Calibration_Cache>;
 | |
| 
 | |
|     // frees commonly used data
 | |
|     void clear();
 | |
| 
 | |
|     std::uint16_t vendorId = 0; // USB vendor identifier
 | |
|     std::uint16_t productId = 0; // USB product identifier
 | |
| 
 | |
|     // USB mode:
 | |
|     // 0: not set
 | |
|     // 1: USB 1.1
 | |
|     // 2: USB 2.0
 | |
|     SANE_Int usb_mode = 0;
 | |
| 
 | |
|     std::string file_name;
 | |
|     std::string calib_file;
 | |
| 
 | |
|     // if enabled, no calibration data will be loaded or saved to files
 | |
|     SANE_Int force_calibration = 0;
 | |
|     // if enabled, will ignore the scan offsets and start scanning at true origin. This allows
 | |
|     // acquiring the positions of the black and white strips and the actual scan area
 | |
|     bool ignore_offsets = false;
 | |
| 
 | |
|     const Genesys_Model* model = nullptr;
 | |
| 
 | |
|     // pointers to low level functions
 | |
|     std::unique_ptr<CommandSet> cmd_set;
 | |
| 
 | |
|     Genesys_Register_Set reg;
 | |
|     Genesys_Register_Set initial_regs;
 | |
|     Genesys_Settings settings;
 | |
|     Genesys_Frontend frontend, frontend_initial;
 | |
|     Genesys_Gpo gpo;
 | |
|     MemoryLayout memory_layout;
 | |
|     Genesys_Motor motor;
 | |
|     std::uint8_t control[6] = {};
 | |
| 
 | |
|     size_t average_size = 0;
 | |
| 
 | |
|     // the session that was configured for calibration
 | |
|     ScanSession calib_session;
 | |
| 
 | |
|     // gamma overrides. If a respective array is not empty then it means that the gamma for that
 | |
|     // color is overridden.
 | |
|     std::vector<std::uint16_t> gamma_override_tables[3];
 | |
| 
 | |
|     std::vector<std::uint16_t> white_average_data;
 | |
|     std::vector<std::uint16_t> dark_average_data;
 | |
| 
 | |
|     bool already_initialized = false;
 | |
| 
 | |
|     bool read_active = false;
 | |
|     // signal wether the park command has been issued
 | |
|     bool parking = false;
 | |
| 
 | |
|     // for sheetfed scanner's, is TRUE when there is a document in the scanner
 | |
|     bool document = false;
 | |
| 
 | |
|     Genesys_Buffer read_buffer;
 | |
| 
 | |
|     // buffer for digital lineart from gray data
 | |
|     Genesys_Buffer binarize_buffer;
 | |
|     // local buffer for gray data during dynamix lineart
 | |
|     Genesys_Buffer local_buffer;
 | |
| 
 | |
|     // total bytes read sent to frontend
 | |
|     size_t total_bytes_read = 0;
 | |
|     // total bytes read to be sent to frontend
 | |
|     size_t total_bytes_to_read = 0;
 | |
| 
 | |
|     // contains computed data for the current setup
 | |
|     ScanSession session;
 | |
| 
 | |
|     // look up table used in dynamic rasterization
 | |
|     unsigned char lineart_lut[256] = {};
 | |
| 
 | |
|     Calibration calibration_cache;
 | |
| 
 | |
|     // number of scan lines used during scan
 | |
|     int line_count = 0;
 | |
| 
 | |
|     // array describing the order of the sub-segments of the sensor
 | |
|     std::vector<unsigned> segment_order;
 | |
| 
 | |
|     // buffer to handle even/odd data
 | |
|     Genesys_Buffer oe_buffer = {};
 | |
| 
 | |
|     // stores information about how the input image should be processed
 | |
|     ImagePipelineStack pipeline;
 | |
| 
 | |
|     // an buffer that allows reading from `pipeline` in chunks of any size
 | |
|     ImageBuffer pipeline_buffer;
 | |
| 
 | |
|     // image buffer where the scanned picture is stored
 | |
|     std::vector<std::uint8_t> img_buffer;
 | |
| 
 | |
|     ImagePipelineNodeBytesSource& get_pipeline_source();
 | |
| 
 | |
|     std::unique_ptr<ScannerInterface> interface;
 | |
| 
 | |
|     bool is_head_pos_known(ScanHeadId scan_head) const;
 | |
|     unsigned head_pos(ScanHeadId scan_head) const;
 | |
|     void set_head_pos_unknown(ScanHeadId scan_head);
 | |
|     void set_head_pos_zero(ScanHeadId scan_head);
 | |
|     void advance_head_pos_by_session(ScanHeadId scan_head);
 | |
|     void advance_head_pos_by_steps(ScanHeadId scan_head, Direction direction, unsigned steps);
 | |
| 
 | |
| private:
 | |
|     // the position of the primary scan head in motor->base_dpi units
 | |
|     unsigned head_pos_primary_ = 0;
 | |
|     bool is_head_pos_primary_known_ = true;
 | |
| 
 | |
|     // the position of the secondary scan head in motor->base_dpi units. Only certain scanners
 | |
|     // have a secondary scan head.
 | |
|     unsigned head_pos_secondary_ = 0;
 | |
|     bool is_head_pos_secondary_known_ = true;
 | |
| 
 | |
|     friend class ScannerInterfaceUsb;
 | |
| };
 | |
| 
 | |
| std::ostream& operator<<(std::ostream& out, const Genesys_Device& dev);
 | |
| 
 | |
| void apply_reg_settings_to_device(Genesys_Device& dev, const GenesysRegisterSettingSet& regs);
 | |
| 
 | |
| void apply_reg_settings_to_device_write_only(Genesys_Device& dev,
 | |
|                                              const GenesysRegisterSettingSet& regs);
 | |
| GenesysRegisterSettingSet
 | |
|     apply_reg_settings_to_device_with_backup(Genesys_Device& dev,
 | |
|                                              const GenesysRegisterSettingSet& regs);
 | |
| 
 | |
| } // namespace genesys
 | |
| 
 | |
| #endif
 |