.TH sane-coolscan 5 "4 July 2000"
.IX sane-coolscan
.SH NAME
sane-coolscan - SANE backend for Nikon film-scanners
.SH ABOUT THIS FILE
This file is a short descripton of the coolscan-backend for sane!
.SH DESCRIPTION
The
.B sane-coolscan
library implements a SANE backend that provides the interface to the following Nikon Coolscan Film scanners: Nikon LS20, LS30, LS1000, LS2000.
.B Even though the backend has worked for a number of people, there are still some problems, especially in combination with some SCSI card/drivers (AHA-1505/aha152x.o) and the autofocus command. You should consider this backend 'alpha' and be carefull when using it the first time.
.SH CONFIGURATION
The configuration file for this backend resides in
@CONFIGDIR@/coolscan.conf.
Its contents is a list of device names that correspond to Nikon Coolscan scanners. Empty lines
and lines starting with a hash mark (#) are ignored. A sample configuration file is
shown below:
#scsi Vendor Model Type
scsi Nikon * Scanner
/dev/scanner
The special device name must be a generic SCSI device or a symlink to such a device.
To find out to which device your scanner is assigned and how you have to set the
permissions of that device, have a look at sane-scsi.
.SH SCSI ADAPTER TIPS
Some SCSI-adapters and low-level SCSI drivers do not work correctly with this backend and the
Coolscan scanners. These systems hang when the autofocus command is send to the Scanner.
To see a list of which card/driver combinations work or dont work have a look at:
http://andreas.rick.free.fr/sane/autofocus.html.
.SH FILES
The backend configuration file:
@CONFIGDIR@/coolscan.conf.
The static library implementing this backend:
@LIBDIR@/libsane-coolscan.a
The shared library implementing this backend:
@LIBDIR@/libsane-coolscan.so
(present on systems that support dynamic loading)
.SH ENVIRONMENT
.B SANE_DEBUG_COOLSCAN
If the library was compiled with debug support enabled, this environment
variable controls the debug level for this backend. E.g., a value of 128
requests all debug output to be printed. Smaller levels reduce verbosity:
SANE_DEBUG_COOLSCAN values
Examples:
on bash:
export SANE_DEBUG_COOLSCAN=8
on csh
setenv SANE_DEBUG_COOLSCAN 8
.SH BUGS
The autofocus command does not work with some SCSI card/driver combinations
The gamma table is not implemented for the LS1000 yet.
The dust-removal is not working yet
.SH SEE ALSO
http://andreas.rick.free.fr/sane/ The homepage of this backend
http://www.sema.be/coolscan/ The original version of the coolscan backend by Didier
sane(7), sane\-scsi(5)