| .TH sane-st400 5 "08 Mar 1999"
 | |
| .IX sane-st400
 | |
| .SH NAME
 | |
| sane-st400 - SANE backend for Siemens ST/Highscan flatbed scanners
 | |
| .SH DESCRIPTION
 | |
| The
 | |
| .B sane-st400
 | |
| library implements a SANE (Scanner Access Now Easy) backend that
 | |
| provides access to Siemens ST400 flatbed scanners and compatibles.
 | |
| At present, the following scanners are supported by this backend:
 | |
| .PP
 | |
| .RS
 | |
| Siemens ST400 (6 bit gray scale)
 | |
| .br
 | |
| Siemens ST800 (6 bit gray scale)
 | |
| .br
 | |
| .RE
 | |
| .PP
 | |
| The driver supports line art and gray scans up to 8bpp.
 | |
| .PP
 | |
| The Siemens ST/Highscan series includes several more models, e.g. the ST300
 | |
| and ST600.  If you own one of these scanners, or a scanner other than the
 | |
| ones listed above that works with this backend, please let us know by sending
 | |
| the scanner's model name, SCSI ID, and firmware revision to
 | |
| .IR sane\-devel@mostang.com .
 | |
| 
 | |
| .SH "DEVICE NAMES"
 | |
| This backend expects device names of the form:
 | |
| .PP
 | |
| .RS
 | |
| .I special
 | |
| .RE
 | |
| .PP
 | |
| Where
 | |
| .I special
 | |
| is either the path-name for the special device that corresponds to a
 | |
| SCSI scanner. For SCSI scanners, the special device name must be a
 | |
| generic SCSI device or a symlink to such a device.  Under Linux, such
 | |
| a device name could be
 | |
| .I /dev/sga
 | |
| or
 | |
| .IR /dev/sge ,
 | |
| for example.  See sane-scsi(5) for details.
 | |
| .SH CONFIGURATION
 | |
| The contents of the
 | |
| .I st400.conf
 | |
| file is a list of device names that correspond to Siemens
 | |
| scanners.  Empty lines and lines starting with a hash mark (#) are
 | |
| ignored.  A sample configuration file is shown below:
 | |
| .PP
 | |
| .RS
 | |
| /dev/scanner
 | |
| .br
 | |
| # this is a comment
 | |
| .br
 | |
| /dev/sge
 | |
| .RE
 | |
| .PP
 | |
| The default configuration file that is distributed with SANE looks like
 | |
| this:
 | |
| .PP
 | |
| .RS
 | |
| scsi SIEMENS "ST 400" Scanner * * 3 0
 | |
| .RE
 | |
| .PP
 | |
| In this configuration, the driver can only access the ST400 model
 | |
| at SCSI ID 3 LUN 0 (see section "BUGS" below for the reason).
 | |
| To use the driver with other scanner models, add an appropriate line to
 | |
| the configuration file.  For example, to use it with an ST800 at SCSI
 | |
| ID 3 LUN 0, add the line:
 | |
| .PP
 | |
| .RS
 | |
| scsi SIEMENS "ST 800" Scanner * * 3 0
 | |
| .RE
 | |
| 
 | |
| .SH FILES
 | |
| .TP
 | |
| .I @CONFIGDIR@/st400.conf
 | |
| The backend configuration file (see also description of
 | |
| .B SANE_CONFIG_DIR
 | |
| below).
 | |
| .TP
 | |
| .I @LIBDIR@/libsane-st400.a
 | |
| The static library implementing this backend.
 | |
| .TP
 | |
| .I @LIBDIR@/libsane-st400.so
 | |
| The shared library implementing this backend (present on systems that
 | |
| support dynamic loading).
 | |
| .SH ENVIRONMENT
 | |
| .TP
 | |
| .B SANE_CONFIG_DIR
 | |
| This environment variable specifies the list of directories that may
 | |
| contain the configuration file.  Under UNIX, the directories are
 | |
| separated by a colon (`:'), under OS/2, they are separated by a
 | |
| semi-colon (`;').  If this variable is not set, the configuration file
 | |
| is searched in two default directories: first, the current working
 | |
| directory (".") and then in /etc/sane.d.  If the value of the
 | |
| environment variable ends with the directory separator character, then
 | |
| the default directories are searched after the explicitly specified
 | |
| directories.  For example, setting
 | |
| .B SANE_CONFIG_DIR
 | |
| to "/tmp/config:" would result in directories "tmp/config", ".", and
 | |
| "/etc/sane.d" being searched (in this order).
 | |
| .TP
 | |
| .B SANE_DEBUG_ST400
 | |
| If the library was compiled with debug support enabled, this environment
 | |
| variable controls the debug level for this backend. E.g., a value of 128
 | |
| requests all debug output to be printed. Smaller levels reduce verbosity.
 | |
| 
 | |
| .SH MISSING FUNCTIONALITY
 | |
| 
 | |
| Everything but the most basic stuff.
 | |
| 
 | |
| .SH BUGS
 | |
| Currently, the backend does not check if the attached device really is
 | |
| a ST400.  It will happily accept everything that matches the configuration
 | |
| entries.  This makes it easy to test the backend with other scanners:
 | |
| Just add an appropriate line to the configuration file.  The configuration
 | |
| file as distributed (see above) only works with the ST400.  Be careful:
 | |
| If there is no config file at all, the backend defaults to /dev/scanner.
 | |
| .PP
 | |
| The ST400 answers on all eight SCSI LUNs.  Normally this is not a problem,
 | |
| as LUN support is usually disabled in SCSI drivers, but if you are seeing
 | |
| multiple instances of the scanner in a device list, either disable LUNs in
 | |
| your SCSI setup or change the entry in the configuration file to match
 | |
| LUN 0 only.
 | |
| 
 | |
| .SH DEBUG
 | |
| If you encounter a bug please set the environment variable
 | |
| SANE_DEBUG_ST400 to 128 and try to regenerate the problem. Then
 | |
| send me a report with the log attached.
 | |
| .PP
 | |
| If you encounter a SCSI bus error or trimmed and/or displaced images please
 | |
| also set the environment variable SANE_DEBUG_SANEI_SCSI to 128 before sending
 | |
| me the report.
 | |
| 
 | |
| .SH "SEE ALSO"
 | |
| sane(7), sane\-scsi(5)
 | |
| .br
 | |
| http://www.informatik.uni-oldenburg.de/~ingo/sane/ 
 | |
| 
 | |
| .SH AUTHOR
 | |
| 
 | |
| Ingo Wilken <Ingo.Wilken@informatik.uni\-oldenburg.de>
 |