kopia lustrzana https://gitlab.com/sane-project/backends
				
				
				
			
		
			
				
	
	
		
			194 wiersze
		
	
	
		
			5.3 KiB
		
	
	
	
		
			Groff
		
	
	
			
		
		
	
	
			194 wiersze
		
	
	
		
			5.3 KiB
		
	
	
	
		
			Groff
		
	
	
| .TH sane-microtek 5 "February 8, 2000"
 | |
| .IX sane-microtek
 | |
| .SH NAME
 | |
| sane-microtek \- SANE backend for Microtek scanners
 | |
| .SH DESCRIPTION
 | |
| The
 | |
| .B sane-microtek
 | |
| library implements a SANE (Scanner Access Now Easy) backend that
 | |
| provides access to the "second generation" Microtek scanners.  At present,
 | |
| the following hardware is known to work with this backend:
 | |
| .PP
 | |
| .RS
 | |
| Microtek ScanMaker E2, E3, E6
 | |
| .br
 | |
| Microtek ScanMaker II, IIG, IIHR, IISP, III
 | |
| .br
 | |
| Microtek ScanMaker 35t, 35t+, 45t
 | |
| .br
 | |
| Microtek ScanMaker 600GS, 600ZS (see bug notes)
 | |
| .br
 | |
| Agfa StudioScan
 | |
| .br
 | |
| Agfa StudioScan II, StudioScan IIsi
 | |
| .br
 | |
| Agfa Arcus II (but not the "Arcus")
 | |
| .br
 | |
| Agfa DuoScan (premliminary)
 | |
| .br
 | |
| Vobis "Highscreen Realscan"
 | |
| .br
 | |
| Microtek Color PageWiz (preliminary)
 | |
| .br
 | |
| .PP
 | |
| Transparent Media Adapter
 | |
| .br
 | |
| Document AutoFeeder
 | |
| .br
 | |
| .RE
 | |
| .PP
 | |
| The driver supports line art, halftone, 8bpp gray, and 24bpp color scans
 | |
| at normal and "expanded" resolutions (i.e. 1200x1200 on an E6), fast scans
 | |
| for color previews, and downloadable gamma tables.
 | |
| .PP
 | |
| The supported scanners are all SCSI scanners.  However, some parallel
 | |
| port models may work (under Linux), if they use a parport->scsi chip,
 | |
| and if you can find a scsi->parport driver.  This is known to be the
 | |
| case for the Color PageWiz.
 | |
| .PP
 | |
| The driver does 
 | |
| .B not
 | |
| support the newest Microtek scanners, such as the V330 and V660, which use
 | |
| a new and very different SCSI-II command set.  For those, try the alternate
 | |
| .B microtek2
 | |
| backend.  Most non-SCSI scanners would use the new command set.  Most
 | |
| scanners newer than the Scanmaker E6 would use the new command set.
 | |
| .PP
 | |
| If you own a Microtek scanner other than the ones listed above, tell us
 | |
| what happens --- see the
 | |
| .BR BUGS
 | |
| section at the end of this document.
 | |
| .PP
 | |
| Although this manual page is generally updated with each release,
 | |
| up-to-date information on new releases and extraneous helpful hints
 | |
| are available from the backend homepage:
 | |
| .br
 | |
| .RS
 | |
| .B http://www.mir.com/mtek/
 | |
| .RE
 | |
| 
 | |
| .SH "DEVICE NAMES"
 | |
| This backend expects device names of the form:
 | |
| .PP
 | |
| .RS
 | |
| .I special
 | |
| .RE
 | |
| .PP
 | |
| Where
 | |
| .I special
 | |
| is the UNIX path-name for the special device that corresponds to the
 | |
| scanner.  The special device name must be a generic SCSI device or a
 | |
| symlink to such a device.  Under Linux, such a device name could be
 | |
| .I /dev/sga
 | |
| or
 | |
| .IR /dev/sge ,
 | |
| for example.
 | |
| .PP
 | |
| 
 | |
| .SH CONFIGURATION
 | |
| The contents of the
 | |
| .I microtek.conf
 | |
| file is a list of device names that correspond to Microtek
 | |
| scanners.  Empty lines and lines starting with a hash mark (#) are
 | |
| ignored.  A sample configuration file is shown below:
 | |
| .PP
 | |
| .RS
 | |
| /dev/scanner
 | |
| .br
 | |
| # this is a comment
 | |
| .br
 | |
| /dev/sge
 | |
| .RE
 | |
| .PP
 | |
| The configuration file may also contain the special tokens
 | |
| .I norealcal
 | |
| or
 | |
| .I noprecal.
 | |
| .I norealcal
 | |
| will disable the use of magic, undocumented scanner calibration commands
 | |
| which are known to work on the E6, but may not work with other models.
 | |
| .I noprecal
 | |
| will disable logic which tries to avoid scanner precalibration.  This logic
 | |
| would only have been activated if the magic calibration code was turned off.
 | |
| 
 | |
| .PP
 | |
| .SH FILES
 | |
| .TP
 | |
| .I @CONFIGDIR@/microtek.conf
 | |
| The backend configuration file (see also description of
 | |
| .B SANE_CONFIG_DIR
 | |
| below).
 | |
| .TP
 | |
| .I @LIBDIR@/libsane-microtek.a
 | |
| The static library implementing this backend.
 | |
| .TP
 | |
| .I @LIBDIR@/libsane-microtek.so
 | |
| The shared library implementing this backend (present on systems that
 | |
| support dynamic loading).
 | |
| 
 | |
| .SH ENVIRONMENT
 | |
| .TP
 | |
| .B SANE_CONFIG_DIR
 | |
| This environment variable specifies the list of directories that may
 | |
| contain the configuration file.  Under UNIX, the directories are
 | |
| separated by a colon (`:'), under OS/2, they are separated by a
 | |
| semi-colon (`;').  If this variable is not set, the configuration file
 | |
| is searched in two default directories: first, the current working
 | |
| directory (".") and then in @CONFIGDIR@.  If the value of the
 | |
| environment variable ends with the directory separator character, then
 | |
| the default directories are searched after the explicitly specified
 | |
| directories.  For example, setting
 | |
| .B SANE_CONFIG_DIR
 | |
| to "/tmp/config:" would result in directories "tmp/config", ".", and
 | |
| "@CONFIGDIR@" being searched (in this order).
 | |
| .TP
 | |
| .B SANE_DEBUG_MICROTEK
 | |
| If the library was compiled with debugging support enabled, this
 | |
| environment variable controls the debug level for this backend. 
 | |
| A value of 128 requests maximally copious debug output; smaller
 | |
| levels reduce verbosity.
 | |
| 
 | |
| .SH "SEE ALSO"
 | |
| sane(7), sane\-scsi(5)
 | |
| 
 | |
| .SH AUTHOR
 | |
| Matt Marjanovic
 | |
| 
 | |
| .SH BUGS
 | |
| Known bugs/limitations are:
 | |
| .PP
 | |
| .RS
 | |
| Brightness and contrast broken.
 | |
| .br
 | |
| The 600GS is grayscale only, and will lock up if you select color.
 | |
| (Unfortunately, the 600GS and 600ZS are indistinguishable by software.)
 | |
| .br
 | |
| .RE
 | |
| .PP
 | |
| i.e. don't complain about these --- but if brightness and/or contrast
 | |
| .B do
 | |
| work for you, please tell me.
 | |
| .PP
 | |
| If your scanner locks up, try setting the 
 | |
| .I norealcal
 | |
| or
 | |
| .I noprecal
 | |
| option in the configuration file (first one, then both), and see if it helps.
 | |
| (If it does, report it.)
 | |
| .PP
 | |
| Send lengthy bug reports and new scanner information to
 | |
| .BR mtek-bugs@mir.com .
 | |
| All bug reports and new scanner inquiries should include an error log file.
 | |
| You can generate copious
 | |
| stderr output by setting the SANE_DEBUG_MICROTEK environment variable
 | |
| described above.  For example:
 | |
| .PP
 | |
| .RS
 | |
| setenv SANE_DEBUG_MICROTEK 128
 | |
| .RE
 | |
| .PP
 | |
| More general comments, suggestions, and inquiries about frontends
 | |
| or SANE should go to 
 | |
| .BR sane\-devel@mostang.com ,
 | |
| the SANE Developers mailing list.
 |