kopia lustrzana https://gitlab.com/sane-project/backends
				
				
				
			
		
			
				
	
	
		
			152 wiersze
		
	
	
		
			4.4 KiB
		
	
	
	
		
			Groff
		
	
	
			
		
		
	
	
			152 wiersze
		
	
	
		
			4.4 KiB
		
	
	
	
		
			Groff
		
	
	
| .TH "sane\-lexmark" "5" "12 Jul 2008" "@PACKAGEVERSION@" "SANE Scanner Access Now Easy"
 | |
| .IX sane\-lexmark
 | |
| .SH "NAME"
 | |
| sane\-lexmark \- SANE backend for Lexmark X1100/X1200 Series scanners
 | |
| .SH "DESCRIPTION"
 | |
| The
 | |
| .B sane\-lexmark
 | |
| library implements a SANE (Scanner Access Now Easy) backend that
 | |
| provides access to the scanner part of Lexmark X1100/X1200 AIOs. This backend
 | |
| should be considered
 | |
| .B beta-quality
 | |
| software! 
 | |
| .PP 
 | |
| The scanners that should work with this backend are:
 | |
| .PP 
 | |
| .RS
 | |
| .ft CR
 | |
| .nf 
 | |
|    Vendor Model           status
 | |
| \-\-\-\-\-\-\-\-\-\-\-\-\-\-\-\-\-\-\-\-\-\-  \-\-\-\-\-\-\-\-\-\-\-
 | |
|   Lexmark X74             good
 | |
|   Lexmark X1110           untested
 | |
|   Lexmark X1140           untested
 | |
|   Lexmark X1150           good
 | |
|   Lexmark X1170           good
 | |
|   Lexmark X1180           good
 | |
|   Lexmark X1185           complete
 | |
|   Lexmark X12xx           good in USB1.1,
 | |
|   			  not fully tested in USB2.0
 | |
|   Dell    A920            good
 | |
| .fi 
 | |
| .ft R
 | |
| .RE
 | |
| 
 | |
| The options the backend supports can either be selected through
 | |
| command line options to programs like scanimage or through GUI
 | |
| elements in xscanimage or xsane.
 | |
| 
 | |
| .br 
 | |
| If you have any strange behavior, please report to the backend
 | |
| maintainer or to the SANE mailing list.
 | |
| 
 | |
| Valid command line options and their syntax can be listed by using 
 | |
| .RS
 | |
| scanimage \-\-help \-d lexmark:usb:<usb port>
 | |
| .RE
 | |
| 
 | |
| .TP 
 | |
| .B Scan Mode Options
 | |
| 
 | |
| .TP 
 | |
| .B \-\-mode
 | |
| selects the basic mode of operation of the scanner valid choices are 
 | |
| .IR Color ,
 | |
| .I Gray
 | |
| and
 | |
| .I Lineart
 | |
| The default mode is Color. The Lineart mode is black and white only (1 bit). 
 | |
| Grayscale will produce 256 levels of gray (8 bits). Color mode allows for over
 | |
| 16 million different colors produced from 24 bits of color information.
 | |
| 
 | |
| .TP 
 | |
| .B \-\-resolution
 | |
| selects the resolution for a scan. The horizontal and vertical resolutions are set 
 | |
| by the value of this option. The scanner is capable of the following resolutions for the specified option value:
 | |
| .PP 
 | |
| .RS
 | |
| .ft CR
 | |
| .nf 
 | |
|   Value   Hor. Resolution  Vert. Resolution 
 | |
|   \-\-\-\-\-   \-\-\-\-\-\-\-\-\-\-\-\-\-\-\-  \-\-\-\-\-\-\-\-\-\-\-\-\-\-\-\-\-\-\-
 | |
|   75      75dpi            75dpi
 | |
|   150     150dpi           150dpi 
 | |
|   300     300dpi           300dpi 
 | |
|   600     600dpi           600dpi 
 | |
|   1200    600dpi           1200dpi  (only for X11xx models with 'B2' sensor)
 | |
| .fi 
 | |
| .ft R
 | |
| .RE
 | |
| 
 | |
| .TP 
 | |
| .B \-\-preview
 | |
| requests a preview scan. The resolution used for that scan is 75 dpi
 | |
| and the scan area and the scan mode are as specified through their options, 
 | |
| or the default if not specified. The default value for preview mode is "no".
 | |
| 
 | |
| .TP 
 | |
| .B \-\-threshold
 | |
| selects the  minimum-brightness to get a white point. The threshold is only used with Lineart mode scans.
 | |
| It is specified as a percentage in the range 0..100% (in steps of 1).  
 | |
| The default value of the threshold option is 50.
 | |
| 
 | |
| 
 | |
| .SH "CONFIGURATION FILE"
 | |
| The configuration file @CONFIGDIR@/lexmark.conf contains only the usb device id (eg usb 0x043d 0x007c).
 | |
| 
 | |
| 
 | |
| .SH "FILES"
 | |
| .TP 
 | |
| .I @LIBDIR@/libsane\-lexmark.a
 | |
| The static library implementing this backend.
 | |
| .TP 
 | |
| .I @LIBDIR@/libsane\-lexmark.so
 | |
| The shared library implementing this backend (present on systems that
 | |
| support dynamic loading).
 | |
| 
 | |
| 
 | |
| .SH "ENVIRONMENT"
 | |
| .TP 
 | |
| .B SANE_DEBUG_LEXMARK
 | |
| .B SANE_DEBUG_LEXMARK_LOW
 | |
| If the library was compiled with debug support enabled, this
 | |
| environment variable controls the debug level for this backend. E.g.,
 | |
| a value of 255 requests all debug output to be printed. Smaller levels
 | |
| reduce verbosity.
 | |
| 
 | |
| 
 | |
| .SH "LIMITATIONS"
 | |
| The windows TWAIN driver has many more options than this SANE
 | |
| backend. However they are only software adjustments. This backend only
 | |
| implements what the scanner can support. For instance, shading correction
 | |
| (vertical stripes due to sensor variation across its width) is done in
 | |
| software. Head park position is also detected by software.
 | |
| The data compression isn't supported for the X1200 series on USB 1.1,
 | |
| leading to slow scans.
 | |
| 
 | |
| .SH "BUGS"
 | |
| .br 
 | |
| No bugs currently known.
 | |
| 
 | |
| 
 | |
| 
 | |
| .SH "SEE ALSO"
 | |
| sane\-scsi(5), scanimage(1), xscanimage(1), xsane(1), sane(7)
 | |
| 
 | |
| 
 | |
| .SH "AUTHOR"
 | |
| .TP 
 | |
| The backend was originally written by Fred Odendaal.
 | |
| .I http://ca.geocities.com/freshshelf@rogers.com/
 | |
| .TP 
 | |
| The new version is currently developed by St\['e]phane Voltz.
 | |
| .I http://stef.dev.free.fr/sane/lexmark
 | |
| .TP
 | |
| X74 support was written by Torsten Houwaart (<ToHo@gmx.de>)
 | |
| .SH "CREDITS"
 | |
| .TP 
 | |
| Many thanks go to:
 | |
| Julien Furgerot who lend me a Dell A920.
 | |
| Robert Price, Dani Ele  and Dalai Felinto for the time they spent recording
 | |
| USB activity and testing the experimental version.
 |