.TH sane-u12 5 "18 June 2004" "@PACKAGEVERSION@" "SANE Scanner Access Now Easy"
 | 
						|
.IX sane-u12
 | 
						|
.SH NAME
 | 
						|
sane-u12 \- SANE backend for Plustek USB flatbed scanners,
 | 
						|
based on older parport designs
 | 
						|
.SH DESCRIPTION
 | 
						|
The
 | 
						|
.B sane-u12
 | 
						|
library implements a SANE (Scanner Access Now Easy) backend that
 | 
						|
provides access to USB flatbed scanners based on Plusteks' ASIC
 | 
						|
98003 (parallel-port ASIC) and a GeneSys Logics' USB-parport
 | 
						|
bridge chip.
 | 
						|
 | 
						|
.SH "SUPPORTED DEVICES"
 | 
						|
The backend is able to support some early Plustek USB scanner based
 | 
						|
their old parport design around the ASIC 98003 and other rebadged
 | 
						|
Plustek devices. The following tables will give you a short overview.
 | 
						|
 | 
						|
If your Plustek scanner has another Product ID, then the device is
 | 
						|
.B NOT
 | 
						|
supported by this backend.
 | 
						|
.br
 | 
						|
 | 
						|
Vendor Plustek \- ID: 0x07B3
 | 
						|
.br
 | 
						|
.ft CR
 | 
						|
.nf
 | 
						|
----------------------------------------------------------
 | 
						|
Model:                   Vendor-ID:       Product-ID:
 | 
						|
----------------------------------------------------------
 | 
						|
OpticPro U12             0x07B3           0x0001
 | 
						|
OpticPro U1212           0x07B3           0x0001
 | 
						|
OpticPro UT12            0x07B3           0x0001
 | 
						|
.fi
 | 
						|
.ft R
 | 
						|
.PP
 | 
						|
 | 
						|
Vendor KYE/Genius
 | 
						|
.br
 | 
						|
.ft CR
 | 
						|
.nf
 | 
						|
--------------------------------------------------------
 | 
						|
USB Model:               Vendor-ID:       Product-ID:
 | 
						|
--------------------------------------------------------
 | 
						|
ColorPage Vivid III USB  0x07B3           0x0001
 | 
						|
ColorPage HR6 V1         0x0458           0x2004
 | 
						|
.fi
 | 
						|
.ft R
 | 
						|
.PP
 | 
						|
 | 
						|
.SH "CONFIGURATION"
 | 
						|
To use your scanner with this backend, you need at least two
 | 
						|
entries in the configuration file
 | 
						|
.I @CONFIGDIR@/u12.conf
 | 
						|
.RS
 | 
						|
.I [usb] vendor-id product-id
 | 
						|
.br
 | 
						|
.I device /dev/usbscanner
 | 
						|
.RE
 | 
						|
.PP
 | 
						|
.I [usb]
 | 
						|
tells the backend, that the following devicename (here
 | 
						|
.IR /dev/usbscanner )
 | 
						|
has to be interpreted as USB scanner device. If vendor- and
 | 
						|
product-id has not been specified, the backend tries to
 | 
						|
detect this by its own. If device is set to
 | 
						|
.I auto
 | 
						|
then the next matching device is used.
 | 
						|
.PP
 | 
						|
.B
 | 
						|
The Options:
 | 
						|
.PP
 | 
						|
option warmup t
 | 
						|
.RS
 | 
						|
.I t
 | 
						|
specifies the warmup period in seconds
 | 
						|
.RE
 | 
						|
.PP
 | 
						|
option lampOff t
 | 
						|
.RS
 | 
						|
.I t
 | 
						|
is the time in seconds for switching off the lamps in
 | 
						|
standby mode
 | 
						|
.RE
 | 
						|
.PP
 | 
						|
option lOffonEnd b
 | 
						|
.RS
 | 
						|
.I b
 | 
						|
specifies the behaviour when closing the backend, 1 --> switch
 | 
						|
lamps off, 0 --> do not change lamp status
 | 
						|
.RE
 | 
						|
 | 
						|
.PP
 | 
						|
See the u12.conf file for examples.
 | 
						|
.PP
 | 
						|
.B Note:
 | 
						|
.br
 | 
						|
You have to make sure, that the USB subsystem is loaded
 | 
						|
correctly and you have access to the device-node. For
 | 
						|
more details see
 | 
						|
.B sane-usb (5)
 | 
						|
manpage. You might use
 | 
						|
.B sane-find-scanner
 | 
						|
to check that you have access to your device.
 | 
						|
.PP
 | 
						|
.B Note:
 | 
						|
.br
 | 
						|
If there's no configuration file, the backend defaults to
 | 
						|
.B device auto
 | 
						|
 | 
						|
.SH FILES
 | 
						|
.TP
 | 
						|
.I @CONFIGDIR@/u12.conf
 | 
						|
The backend configuration file
 | 
						|
.TP
 | 
						|
.I @LIBDIR@/libsane-u12.a
 | 
						|
The static library implementing this backend.
 | 
						|
.TP
 | 
						|
.I @LIBDIR@/libsane-u12.so
 | 
						|
The shared library implementing this backend (present on systems that
 | 
						|
support dynamic loading).
 | 
						|
 | 
						|
.SH ENVIRONMENT
 | 
						|
.TP
 | 
						|
.B SANE_CONFIG_DIR
 | 
						|
This environment variable specifies the list of directories that may
 | 
						|
contain the configuration file.  Under UNIX, the directories are
 | 
						|
separated by a colon (`:'), under OS/2, they are separated by a
 | 
						|
semi-colon (`;').  If this variable is not set, the configuration file
 | 
						|
is searched in two default directories: first, the current working
 | 
						|
directory (".") and then in @CONFIGDIR@.  If the value of the
 | 
						|
environment variable ends with the directory separator character, then
 | 
						|
the default directories are searched after the explicitly specified
 | 
						|
directories.  For example, setting
 | 
						|
.B SANE_CONFIG_DIR
 | 
						|
to "/tmp/config:" would result in directories "tmp/config", ".", and
 | 
						|
"@CONFIGDIR@" being searched (in this order).
 | 
						|
.TP
 | 
						|
.B SANE_DEBUG_U12
 | 
						|
If the library was compiled with debug support enabled, this
 | 
						|
environment variable controls the debug level for this backend.  Higher
 | 
						|
debug levels increase the verbosity of the output.
 | 
						|
 | 
						|
Example:
 | 
						|
export SANE_DEBUG_U12=10
 | 
						|
 | 
						|
.SH "SEE ALSO"
 | 
						|
.BR sane (7),
 | 
						|
.BR sane-usb (5),
 | 
						|
.BR sane-plustek (5),
 | 
						|
.br
 | 
						|
.I @DOCDIR@/u12/U12.changes
 | 
						|
.br
 | 
						|
.I http://www.gjaeger.de/scanner/u12/
 | 
						|
 | 
						|
.SH "CONTACT AND BUG-REPORTS"
 | 
						|
Please send any information and bug-reports to:
 | 
						|
.br
 | 
						|
.B SANE Mailing List
 | 
						|
.PP
 | 
						|
Additional info and hints can be obtained from our
 | 
						|
.br
 | 
						|
Mailing-List archive at:
 | 
						|
.br
 | 
						|
.B http://www.sane-project.org/mailing-lists.html
 | 
						|
.PP
 | 
						|
or directly from the projects' homepage at:
 | 
						|
.br
 | 
						|
.B http://www.gjaeger.de/scanner/u12/
 | 
						|
.PP
 | 
						|
To obtain debug messages from the backend, please set the
 | 
						|
environment-variable
 | 
						|
.I SANE_DEBUG_U12
 | 
						|
before calling your favorite scan-frontend (i.e. xscanimage).
 | 
						|
.br
 | 
						|
.B i.e.: export SANE_DEBUG_U12=20 ; xscanimage
 | 
						|
.PP
 | 
						|
The value controls the verbosity of the backend.
 | 
						|
 | 
						|
.SH "KNOWN BUGS & RESTRICTIONS"
 | 
						|
* The driver is in alpha state, so please don't expect too much!!!
 | 
						|
.PP
 | 
						|
* When using libusb, it might be, that the backend hangs. 
 | 
						|
In that case, reconnect the scanner.
 |