| To do:
 | |
| ======
 | |
| - implement coarse calibration to determine settings for analog-front-end
 | |
|   All CCDs encountered so far seem to need about the same settings however.
 | |
| 
 | |
| - Store analog calibration data somewhere.
 | |
|   Use currently used values as default.
 | |
| 
 | |
| - Suggestions by Marcin Cieslak:
 | |
| 	- clean up structures
 | |
| 	- clean up namespace
 | |
| 	- clean up source formatting ('indent --gnu' ?)
 | |
| 
 | |
| 
 | |
| - implement real calibration, using 12 bit data at 600 dpi
 | |
|   instead of 8 bit data.at 150 dpi.
 | |
|   -> is now at 600 dpi, not yet at 12 bit
 | |
| 
 | |
| - design a mechanism to set the scan and calibration areas
 | |
|   a) part of HWProps structure, or
 | |
|   b) set by user at first scan
 | |
| 
 | |
| - further investigate scanner registers
 | |
|   a) study backtracking register more
 | |
|   b) identify bits in bit-oriented registers.
 | |
| 
 | |
| - add more error checking ('sanity checking') on parameters
 | |
| 
 | |
| - figure out what the USB interrupts mean that sometimes occur.
 | |
| 
 | |
| 
 | |
| 
 | |
| Done
 | |
| ====
 | |
| 
 | |
| - Get rid of mytypes.h / fix types
 | |
|   Now an int is implicitly assumed to be 32 bit.
 | |
| 
 | |
| - make backend comply with tstbackend
 | |
| -> all externs and publics removed when compiling towards sane
 | |
| 
 | |
| - implement sane_cancel properly
 | |
| -> done by ullsig
 | |
| 
 | |
| - implement timing mechanism for scanner lamp
 | |
|   so scanning can only start if the lamp was already on for 30 seconds
 | |
| Possible implementation:
 | |
| On startup: if lamp is off, turn it on and start timer
 | |
| On scan: if lamp is off, turn it on and start timer. Wait for timer expiry.
 | |
| On exit: if scanner chip is niash00012 then turn off lamp,
 | |
|   otherwise let the scanner turn it off automatically
 | |
| -> Implemented by Ullrich Sigwanz
 | |
| 
 | |
| - try out parallel port scanning on HP3400/4300
 | |
| -> parallel port support will be dropped, no people to test/develop it
 | |
| 
 | |
| - investigate vertical resolution setting of hp3400/4300.
 | |
| -> experiment with the motor table, formula is already known to generate it
 | |
| -> 600 dpi is possible by doubling most values in the table
 | |
| -> 150 dpi can be done by using register 0x06 to skip every other line
 | |
| 
 | |
| - Add separate gamma tables for R, G, B. This should be easy (look at how
 | |
|   other backends do it) but is not really required yet.
 | |
| -> not required
 |