kopia lustrzana https://gitlab.com/sane-project/backends
175 wiersze
5.4 KiB
Groff
175 wiersze
5.4 KiB
Groff
.TH sane-agfafocus 5 "17 Oct 1998" "@PACKAGEVERSION@" "SANE Scanner Access Now Easy"
|
||
.IX sane-agfafocus
|
||
.SH NAME
|
||
sane-agfafocus \- SANE backend for AGFA Focus flatbed scanners
|
||
.SH DESCRIPTION
|
||
The
|
||
.B sane-agfafocus
|
||
library implements a SANE (Scanner Access Now Easy) backend that
|
||
provides access to AGFA Focus flatbed scanners. At present, the following
|
||
scanners are supported from this backend:
|
||
.PP
|
||
.RS
|
||
AGFA Focus GS Scanner (6 bit gray scale) (untested)
|
||
.br
|
||
AGFA Focus Lineart Scanner (lineart) (untested)
|
||
.br
|
||
AGFA Focus II (8 bit gray scale) (untested)
|
||
.br
|
||
AGFA Focus Color (24 bit color 3-pass)
|
||
.br
|
||
AGFA Focus Color Plus (24 bit color 3-pass)
|
||
.br
|
||
.PP
|
||
Siemens S9036 (8 bit gray scale) (untested)
|
||
.br
|
||
.RE
|
||
.PP
|
||
The driver supports line art, 6bpp and 8bpp gray, 18bpp and 24bpp
|
||
color scans.
|
||
.PP
|
||
If you own a scanner other than the ones listed above that works with
|
||
this backend, please let us know by sending the scanner's model name,
|
||
SCSI id, and firmware revision to
|
||
.IR sane\-devel@lists.alioth.debian.org .
|
||
Have a look at http://www.sane\-project.org/mailing\-lists.html
|
||
concerning subscription to sane-devel.
|
||
.PP
|
||
All of these scanners are pre-SCSI-2, and do not even report properly
|
||
to SCSI Inquiry. This is typically evident in SCSI bus scans, where
|
||
the scanner will come up with only garbage as vendor and models strings.
|
||
|
||
.SH "DEVICE NAMES"
|
||
This backend expects device names of the form:
|
||
.PP
|
||
.RS
|
||
.I special
|
||
.RE
|
||
.PP
|
||
Where
|
||
.I special
|
||
is either the path-name for the special device that corresponds to a
|
||
SCSI scanner. For SCSI scanners, the special device name must be a
|
||
generic SCSI device or a symlink to such a device. Under Linux, such
|
||
a device name could be
|
||
.I /dev/sga
|
||
or
|
||
.IR /dev/sge ,
|
||
for example. See sane-scsi(5) for details.
|
||
.SH CONFIGURATION
|
||
The contents of the
|
||
.I agfafocus.conf
|
||
file is a list of device names that correspond to AGFA Focus
|
||
scanners. Empty lines and lines starting with a hash mark (#) are
|
||
ignored. A sample configuration file is shown below:
|
||
.PP
|
||
.RS
|
||
/dev/scanner
|
||
.br
|
||
# this is a comment
|
||
.br
|
||
/dev/sge
|
||
.RE
|
||
|
||
.PP
|
||
.SH FILES
|
||
.TP
|
||
.I /etc/sane.d/agfafocus.conf
|
||
The backend configuration file (see also description of
|
||
.B SANE_CONFIG_DIR
|
||
below).
|
||
.TP
|
||
.I /usr/lib/libsane-agfafocus.a
|
||
The static library implementing this backend.
|
||
.TP
|
||
.I /usr/lib/libsane-agfafocus.so
|
||
The shared library implementing this backend (present on systems that
|
||
support dynamic loading).
|
||
.SH ENVIRONMENT
|
||
.TP
|
||
.B SANE_CONFIG_DIR
|
||
This environment variable specifies the list of directories that may
|
||
contain the configuration file. Under UNIX, the directories are
|
||
separated by a colon (`:'), under OS/2, they are separated by a
|
||
semi-colon (`;'). If this variable is not set, the configuration file
|
||
is searched in two default directories: first, the current working
|
||
directory (".") and then in /etc/sane.d. If the value of the
|
||
environment variable ends with the directory separator character, then
|
||
the default directories are searched after the explicitly specified
|
||
directories. For example, setting
|
||
.B SANE_CONFIG_DIR
|
||
to "/tmp/config:" would result in directories "tmp/config", ".", and
|
||
"/etc/sane.d" being searched (in this order).
|
||
.TP
|
||
.B SANE_DEBUG_AGFAFOCUS
|
||
If the library was compiled with debug support enabled, this environment
|
||
variable controls the debug level for this backend. E.g., a value of 128
|
||
requests all debug output to be printed. Smaller levels reduce verbosity.
|
||
SANE_DEBUG_AGFAFOCUS values:
|
||
|
||
.DS
|
||
.sp
|
||
.ft CR
|
||
.nf
|
||
Number Remark
|
||
|
||
0 print important errors (printed each time)
|
||
1 print errors
|
||
2 print sense
|
||
3 print warnings
|
||
4 print scanner-inquiry
|
||
5 print informations
|
||
6 print less important informations
|
||
7 print called procedures
|
||
8 print reader_process messages
|
||
10 print called sane-init-routines
|
||
11 print called sane-procedures
|
||
12 print sane infos
|
||
13 print sane option-control messages
|
||
|
||
.SH MISSING FUNCTIONALITY
|
||
|
||
Uploading of dither matrices and tonecurves has been implemented, but
|
||
so far has not proven to be useful for anything. For this reason
|
||
these options have been disabled.
|
||
|
||
.SH BUGS
|
||
The scanners that do not support disconnect have problems with SCSI
|
||
timeouts if the SCSI bus gets loaded, eg. if you do a kernel build at
|
||
the same time as scanning. To see if your scanner supports
|
||
disconnect, run "SANE_DEBUG_AGFAFOCUS=128 scanimage -L" in sh and look
|
||
for the "disconnect:" line)
|
||
|
||
.SH DEBUG
|
||
If you have problems with SANE not detecting your scanner, make sure the
|
||
Artec backend is disabled. Somehow, this backend causes at least my scanner
|
||
not to respond correctly to SCSI inquiry commands.
|
||
.PP
|
||
If you encounter a bug please set the environment variable
|
||
SANE_DEBUG_AGFAFOCUS to 128 and try to regenerate the problem. Then
|
||
send me a report with the log attached.
|
||
.PP
|
||
If you encounter a SCSI bus error or trimmed and/or displaced images please
|
||
also set the environment variable SANE_DEBUG_SANEI_SCSI to 128 before sending
|
||
me the report.
|
||
|
||
.SH TODO
|
||
.TP
|
||
.B More scanners?
|
||
|
||
The AGFA ACS and ARCUS scanners are similar to the FOCUS scanners.
|
||
The driver could probably be extended to support these scanners
|
||
without too many changes. I do not have access to such scanners, and
|
||
cannot add support for it. However, if you are in possession of such
|
||
a scanner, I could be helpful in adding support for these scanners.
|
||
|
||
The AGFA HORIZON scanners are SCSI-2 scanners, and it would probably
|
||
be easier to support these scanners in a SCSI-2 compliant backend.
|
||
.SH "SEE ALSO"
|
||
sane(7), sane\-scsi(5)
|
||
|
||
.SH AUTHOR
|
||
|
||
Ingo Schneider and Karl Anders <20>ygard.
|
||
|