.TH sane-pint 5 "13 May 1998"
|
|
.IX sane-pint
|
|
.SH NAME
|
|
sane-pint - SANE backend for scanners that use the PINT device driver
|
|
.SH DESCRIPTION
|
|
The
|
|
.B sane-pint
|
|
library implements a SANE (Scanner Access Now Easy) backend that
|
|
provides generic access to hand-held and flatbed scanners using the
|
|
PINT (PINT Is Not Twain) device driver. The PINT driver is being
|
|
actively developed on the OpenBSD platform, and has been ported to a
|
|
few other *nix-like operating systems.
|
|
.PP
|
|
PINT is designed to provide an
|
|
.BR ioctl (2)
|
|
interface to many different scanner types. However, this backend has
|
|
only been tested with flatbed single-pass scanners, and more work will
|
|
probably be required to get it to use other scanner types
|
|
successfully.
|
|
.PP
|
|
If have successfully used the PINT driver with your scanner, but it
|
|
does not work using this SANE backend, please let us know. To do
|
|
this, send a mail with the relevant information for your scanner to
|
|
.IR sane\-devel@mostang.com .
|
|
Have a look at http://www.mostang.com/sane/mail.html concerning subscription
|
|
to sane-devel.
|
|
|
|
.SH "DEVICE NAMES"
|
|
This backend expects device names of the form:
|
|
.PP
|
|
.RS
|
|
.I special
|
|
.RE
|
|
.PP
|
|
Where
|
|
.I special
|
|
is the UNIX path-name for the special device that corresponds to the
|
|
scanner. The special device name must be a PINT device or a symlink
|
|
to such a device. For example, under NetBSD or OpenBSD, such a device
|
|
name could be
|
|
.I /dev/ss0
|
|
or
|
|
.IR /dev/scan0 .
|
|
.SH CONFIGURATION
|
|
The contents of the
|
|
.IR pint.conf .
|
|
file is a list of device names that correspond to PINT
|
|
scanners. Empty lines and lines starting with a hash mark (#) are
|
|
ignored. A sample configuration file is shown below:
|
|
.PP
|
|
.RS
|
|
/dev/scanner
|
|
.br
|
|
# this is a comment
|
|
.br
|
|
/dev/ss1
|
|
.RE
|
|
.SH FILES
|
|
.TP
|
|
.I @CONFIGDIR@/pint.conf
|
|
The backend configuration file (see also description of
|
|
.B SANE_CONFIG_DIR
|
|
below).
|
|
.TP
|
|
.I @LIBDIR@/libsane-pint.a
|
|
The static library implementing this backend.
|
|
.TP
|
|
.I @LIBDIR@/libsane-pint.so
|
|
The shared library implementing this backend (present on systems that
|
|
support dynamic loading).
|
|
.SH ENVIRONMENT
|
|
.TP
|
|
.B SANE_CONFIG_DIR
|
|
This environment variable specifies the list of directories that may
|
|
contain the configuration file. Under UNIX, the directories are
|
|
separated by a colon (`:'), under OS/2, they are separated by a
|
|
semi-colon (`;'). If this variable is not set, the configuration file
|
|
is searched in two default directories: first, the current working
|
|
directory (".") and then in @CONFIGDIR@. If the value of the
|
|
environment variable ends with the directory separator character, then
|
|
the default directories are searched after the explicitly specified
|
|
directories. For example, setting
|
|
.B SANE_CONFIG_DIR
|
|
to "/tmp/config:" would result in directories "tmp/config", ".", and
|
|
"@CONFIGDIR@" being searched (in this order).
|
|
.TP
|
|
.B SANE_DEBUG_PINT
|
|
If the library was compiled with debug support enabled, this
|
|
environment variable controls the debug level for this backend. E.g.,
|
|
a value of 128 requests all debug output to be printed. Smaller
|
|
levels reduce verbosity.
|
|
.SH SEE ALSO
|
|
sane(7)
|
|
.SH AUTHOR
|
|
Gordon Matzigkeit, adapted from existing backends written by David
|
|
Mosberger.
|
|
.SH BUGS
|
|
|
|
There are minor roundoff errors when adjusting the ranges, since
|
|
PINT uses units of 1/1200 of an inch, and SANE normally uses
|
|
millimeters. Symptoms of these errors are skewed images. This should
|
|
really be fixed (no pun intended) as soon as possible, but I just
|
|
don't know/care enough about fixed-point representation and roundoff
|
|
errors to do this correctly. Workaround: use inches as the scanning
|
|
unit, and everything usually works fine.
|
|
|
|
The PINT 0.5e interface does not provide a way to determine valid
|
|
ranges for DPI, modes, and scan sizes. So, the SANE backend queries
|
|
the PINT device, and dynamically discovers valid ranges by doing a
|
|
binary search. This means that the driver takes longer to initialize
|
|
than seems necessary.
|
|
|
|
Resetting the scanner does not seem to work (at least not on my HP
|
|
ScanJet 4p). For that reason, the driver sends a SCIOCRESTART, then
|
|
gobbles up any remaining input until it hits EOF.
|
|
|
|
Not all of the scanners have been identified (i.e. whether they are
|
|
flatbed or handheld).
|
|
|
|
X and Y resolutions are assumed to be the same.
|
|
|
|
No testing has been done on three-pass or handheld scanners, or with
|
|
Automatic Document Feeder support.
|