| .TH sane-coolscan 5 "4 July 2000" "@PACKAGEVERSION@" "SANE Scanner Access Now Easy"
 | |
| .IX sane-coolscan
 | |
| 
 | |
| .SH NAME
 | |
| sane-coolscan \- SANE backend for Nikon film-scanners
 | |
| 
 | |
| .SH ABOUT THIS FILE
 | |
| 
 | |
| This file is a short descripton of the coolscan-backend for sane! 
 | |
| 
 | |
| .SH DESCRIPTION
 | |
| 
 | |
| The
 | |
| .B sane-coolscan
 | |
| library implements a SANE backend that provides the interface to the following Nikon Coolscan Film scanners: Nikon LS20, LS30, LS1000, LS2000.
 | |
| 
 | |
| .B Even though the backend has worked for a number of people, there are still some problems, especially in combination with some SCSI card/drivers (AHA-1505/aha152x.o) and the autofocus command. You should consider this backend 'alpha' and be carefull when using it the first time.
 | |
| 
 | |
| .SH CONFIGURATION
 | |
| 
 | |
| The configuration file for this backend resides in 
 | |
| @CONFIGDIR@/coolscan.conf. 
 | |
| 
 | |
| Its contents is a list of device names that correspond to Nikon Coolscan scanners. Empty lines
 | |
| and lines starting with a hash mark (#) are ignored. A sample configuration file is
 | |
| shown below: 
 | |
| 
 | |
|  #scsi Vendor Model Type 
 | |
|  scsi Nikon * Scanner 
 | |
|  /dev/scanner 
 | |
| 
 | |
| The special device name must be a generic SCSI device or a symlink to such a device.
 | |
| To find out to which device your scanner is assigned and how you have to set the
 | |
| permissions of that device, have a look at sane-scsi. 
 | |
| 
 | |
| .SH SCSI ADAPTER TIPS
 | |
| 
 | |
| Some SCSI-adapters and low-level SCSI drivers do not work correctly with this backend and the
 | |
| Coolscan scanners. These systems hang when the autofocus command is send to the Scanner.
 | |
| To see a list of which card/driver combinations work or dont work have a look at:
 | |
| http://andreas.rick.free.fr/sane/autofocus.html.
 | |
| 
 | |
| 
 | |
| 
 | |
| .SH FILES
 | |
| 
 | |
| The backend configuration file:
 | |
|  @CONFIGDIR@/coolscan.conf. 
 | |
| 
 | |
| The static library implementing this backend:
 | |
|  @LIBDIR@/libsane-coolscan.a
 | |
| 
 | |
| The shared library implementing this backend:
 | |
|  @LIBDIR@/libsane-coolscan.so
 | |
|  (present on systems that support dynamic loading)
 | |
| 
 | |
| .SH ENVIRONMENT
 | |
| 
 | |
| .B SANE_DEBUG_COOLSCAN
 | |
|  If the library was compiled with debug support enabled, this environment
 | |
| variable controls the debug level for this backend. E.g., a value of 128
 | |
| requests all debug output to be printed. Smaller levels reduce verbosity:
 | |
| SANE_DEBUG_COOLSCAN values
 | |
| 
 | |
| Examples:
 | |
|  on bash:
 | |
|  export SANE_DEBUG_COOLSCAN=8
 | |
|  on csh
 | |
|  setenv SANE_DEBUG_COOLSCAN 8
 | |
| 
 | |
| .SH BUGS
 | |
| 
 | |
|  The autofocus command does not work with some SCSI card/driver combinations
 | |
|  The gamma table is not implemented for the LS1000 yet.
 | |
|  The dust-removal is not working yet
 | |
| 
 | |
| .SH SEE ALSO
 | |
| 
 | |
|  http://andreas.rick.free.fr/sane/ The homepage of this backend
 | |
|  http://www.sema.be/coolscan/  The original version of the coolscan backend by Didier
 | |
|  sane(7), sane\-scsi(5)
 | |
| 
 | |
| .SH THANKS TO
 | |
| 
 | |
|  Didier Carlier - For writing the original Coolscan backend (without it I would not have started this) 
 | |
|  Oliver.Rauch - For adapting xsane so quickly to the infrared stuff.
 | |
|  All the other people working on SANE.
 | |
| 
 | |
| .SH AUTHOR
 | |
| Andreas Rick
 | |
| 
 | |
| .SH EMAIL-CONTACT
 | |
| andreas.rick@free.fr
 |