CHANGES FOR UMAX BACKEND FOR SANE
 | 
						|
---------------------------------
 | 
						|
 | 
						|
umax -> sane-0.6:
 | 
						|
-----------------
 | 
						|
 | 
						|
    * umax-sane-backend created:
 | 
						|
      - umax.c splitted in:
 | 
						|
        umax-cli.c, umax-scsi.c, umax-driver.c, umax-text.c
 | 
						|
      - umax.h splitted in:
 | 
						|
        umax-scanner.h, umax-scsi.h, umax-scsidef.h, umax-struct.h
 | 
						|
      - outputs done by DBG(level,msg,args...) defined in debug.h
 | 
						|
      - scsi-calls changed to sane-format (of sane-0.57)
 | 
						|
      - created umax.c and umax.h for sane-backend
 | 
						|
 | 
						|
    * changed search-path for scsi.h and sg.h, now needs /usr/include/scsi
 | 
						|
 | 
						|
    * removed mistake in bound-function
 | 
						|
 | 
						|
    * added "Vista S-6E" as supported
 | 
						|
 | 
						|
    * added PowerLook-II (PL-II) as supported
 | 
						|
 | 
						|
    * added Astra 600S as supported
 | 
						|
 | 
						|
 | 
						|
sane-0.6 / 0.61 / 0.62 -> 0.63
 | 
						|
------------------------------
 | 
						|
 | 
						|
    * added exception to gpl-licence:
 | 
						|
    >   This program is free software; you can redistribute it and/or
 | 
						|
    >   modify it under the terms of the GNU General Public License as
 | 
						|
    >   published by the Free Software Foundation; either version 2 of the
 | 
						|
    >   License, or (at your option) any later version.
 | 
						|
    >
 | 
						|
    >   This program is distributed in the hope that it will be useful, but
 | 
						|
    >   WITHOUT ANY WARRANTY; without even the implied warranty of
 | 
						|
    >   MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE.  See the GNU
 | 
						|
    >   General Public License for more details.
 | 
						|
    >
 | 
						|
    >   You should have received a copy of the GNU General Public License
 | 
						|
    >   along with this program; if not, write to the Free Software
 | 
						|
    >   Foundation, Inc., 59 Temple Place - Suite 330, Boston,
 | 
						|
    >   MA 02111-1307, USA.
 | 
						|
    >
 | 
						|
    >   As a special exception, the authors of SANE give permission for
 | 
						|
    >   additional uses of the libraries contained in this release of SANE.
 | 
						|
    >
 | 
						|
    >   The exception is that, if you link a SANE library with other files
 | 
						|
    >   to produce an executable, this does not by itself cause the
 | 
						|
    >   resulting executable to be covered by the GNU General Public
 | 
						|
    >   License.  Your use of that executable is in no way restricted on
 | 
						|
    >   account of linking the SANE library code into it.
 | 
						|
    >
 | 
						|
    >   This exception does not, however, invalidate any other reasons why
 | 
						|
    >   the executable file might be covered by the GNU General Public
 | 
						|
    >   License.
 | 
						|
    >
 | 
						|
    >   If you submit changes to SANE to the maintainers to be included in
 | 
						|
    >   a subsequent release, you agree by submitting the changes that
 | 
						|
    >   those changes may be distributed with this exception intact.
 | 
						|
    >
 | 
						|
    >   If you write modifications of your own for SANE, it is your choice
 | 
						|
    >   whether to permit this exception to apply to your modifications.
 | 
						|
    >   If you do not wish that, delete this exception notice.
 | 
						|
 | 
						|
    * split resolution in x-res and y-res, flag bind-resolution
 | 
						|
 | 
						|
    * only sane_... functions will be exported from umax-backend,
 | 
						|
      all umax_... functions are made static
 | 
						|
 | 
						|
    * removed umax-emergency-routine for SANE
 | 
						|
 | 
						|
    * made program-flow (esp. with do_canel) SANE-specific
 | 
						|
 | 
						|
    * fixed missing 3-pass parts
 | 
						|
 | 
						|
    * made scanmodes, sources, analog gamma, gamma download, negative,
 | 
						|
      quality calibration, highlight, shadow only selectable if they are
 | 
						|
      available
 | 
						|
 | 
						|
    * calibration-mode selectable in advanced options if available
 | 
						|
 | 
						|
    * warmup selectable if available
 | 
						|
 | 
						|
    * changed umax-scsi.c like described from Gordon Matzigkeit
 | 
						|
      in his diff/patch-file from 21.06.97 so that the umax-backend
 | 
						|
      should compile on non-linux-systems now - thanks!
 | 
						|
 | 
						|
    * split highlight and shadow in R, G and B for color-mode.
 | 
						|
 | 
						|
    * reset adf and uta flag when not used (in sane_start)
 | 
						|
 | 
						|
    * added possibilty to change calibration-mode if available
 | 
						|
 | 
						|
    * added send_halftone_pattern to umax-scsi.c
 | 
						|
 | 
						|
    * changed umax-scsi.c like described from Gordon Matzigkeit
 | 
						|
      in his diff/patch-file from 21.06.97 so that the umax-backend
 | 
						|
      should compile on non-linux-systems now - thanks
 | 
						|
 | 
						|
    * added support for each color (R,G,B) for highlight and shadow
 | 
						|
 | 
						|
    * added "Astra 1200S" and "UC840" as supported 
 | 
						|
 | 
						|
    * added bad bugfix for preview-problem with S6E
 | 
						|
      (in umax-scsi.c function start_scan)
 | 
						|
 | 
						|
    * moved resolution-check from check_values to bound_scanarea,
 | 
						|
      now no floatingpoint-exception will occur if no resolution is given!
 | 
						|
 | 
						|
    * changed range-check for width and height
 | 
						|
 | 
						|
    * removed bug in set_window for three-pass-rgb-mode
 | 
						|
      -selected wrong buffer for some green and blue options
 | 
						|
      -scanmode now is greyscale instead of rgb
 | 
						|
 | 
						|
    * changed start_scan(us) to better use with wid-list
 | 
						|
      and added missing 3 wid-bytes in scan.cmd
 | 
						|
 | 
						|
    * removed parameter color in three_pass_function_headers,
 | 
						|
      the color ist taken from us->three_pass_color now.
 | 
						|
 | 
						|
 | 
						|
sane-0.63/0.64/0.65 -> 0.66
 | 
						|
---------------------------
 | 
						|
 | 
						|
    * changed gamma-data-upload for 3-pass-color-scan
 | 
						|
 | 
						|
    * corrected wrong calculation for highlight and shadow
 | 
						|
      selection for rgb-values
 | 
						|
 | 
						|
    * changed gamma data to use 8 bit (256 bytes) or 10 bit (1024 bytes)
 | 
						|
 | 
						|
    * included 10/30 bits per pixel mode
 | 
						|
 | 
						|
    * changed bug in sane_exit (free()) that sometimes made a
 | 
						|
      segmentation-fault
 | 
						|
 | 
						|
    * made patches runtime-selectable
 | 
						|
 | 
						|
    * changed set_window_command to support 30 bits per pixel
 | 
						|
 | 
						|
    * changed send_gamma_data to support three_pass_gamma and 10/30 bpp
 | 
						|
 | 
						|
    * changed row_len in umax_bound_scanarea to 10/30 bit mode
 | 
						|
 | 
						|
    * added halftone-support for ug630, uc630 and uc840,
 | 
						|
      but I don't know if all values are ok!
 | 
						|
 | 
						|
    * changed CBHS-50-range to 78-178 (from 103-153)
 | 
						|
 | 
						|
    * changed rangecheck for highlight and shadow
 | 
						|
 | 
						|
    * fixed get_cbhs_range-bug in umax-scsidef.h
 | 
						|
 | 
						|
    * added ADF-inquiry-bits to umax-scsidef.h
 | 
						|
 | 
						|
    * added color_line_arrangement_mode-inquiry-byte to umax-scsidef.h
 | 
						|
 | 
						|
    * added CCD_line_distance-inquiry-byte to umax-scsidef.h
 | 
						|
 | 
						|
    * added all most unused bits and bytes in inquiry to umax-scsidef.h
 | 
						|
 | 
						|
    * made patches runtime-selectable
 | 
						|
 | 
						|
 | 
						|
sane-0.66 -> 0.67
 | 
						|
-----------------
 | 
						|
 | 
						|
    * removed bug in sane_start: ADF and UTA flags have not been set correct
 | 
						|
 | 
						|
    * removed bug in init_options: value range for 10 gamma-input-bits corrected
 | 
						|
 | 
						|
    * made custom gamma available for lineart and halftone for nonlinear effects
 | 
						|
 | 
						|
    * added Vista-T630 as supported scanner
 | 
						|
 | 
						|
    * removed test_warmup in wait_scanner because adaptec 1542 has problems
 | 
						|
      with request_sense-command in test_warmup
 | 
						|
      it was only used for printing a message, so it was not important.
 | 
						|
 | 
						|
    * if a scanner has a full inquiry-block but is not known to be supported,
 | 
						|
      the driver will print a warning and continue instead of aborting,
 | 
						|
      option --continue (on umax-cli) will suppress the warning!
 | 
						|
 | 
						|
    * changed ugly definition
 | 
						|
      char gamma[x] -> char *gamma; gamma=alloca(x);
 | 
						|
 | 
						|
    * removed bug (wrong length for 10 bit-gamma) in send_gamma_data
 | 
						|
 | 
						|
    * changed all buffer-definitions to unsigned char and insterted
 | 
						|
      type conversions, so there are no more warnings because of
 | 
						|
      typemismatches.
 | 
						|
 | 
						|
    * corrected bad definition of set_DCF2_gamma_output_bits
 | 
						|
 | 
						|
 | 
						|
sane-0.67 -> 0.68
 | 
						|
-----------------
 | 
						|
 | 
						|
    * changed open config to fp = sanei_config_open(UMAX_CONFIG_FILE)
 | 
						|
 | 
						|
    * changed all set OPT...BIND commands, endless-loop happend in sane-0.67
 | 
						|
      =>ane-0.67-umax-fix.diff.gz
 | 
						|
      after that patch changed same for ten_bit_mode
 | 
						|
 | 
						|
    * changed some strdup() to (SANE_Char *)strdup()
 | 
						|
 | 
						|
    * added UMAX Astra 610S as supported scanner. it has the same problems
 | 
						|
      in color-mode like the Astra 600S.
 | 
						|
 | 
						|
 | 
						|
sane-0.68 -> 0.69
 | 
						|
-----------------
 | 
						|
 | 
						|
    * changed maximum y-resolution from optical_res to y_res
 | 
						|
 | 
						|
    * changed sane_cancel (waitpid) like suggested by David Mosberger
 | 
						|
 | 
						|
    * added #include <lalloca.h> for AIX-support
 | 
						|
 | 
						|
    * replaced call to umax_wait_scanner with umax_do_calibration
 | 
						|
      after umax_start_scan in umax.c
 | 
						|
 | 
						|
    * moved sense_handler to umax-scsi.c
 | 
						|
 | 
						|
    * removed call to umax_get_data_buffer_status in reader_process
 | 
						|
 | 
						|
    * added umax_send_shading_data, umax_send_gain_data
 | 
						|
      and   umax_read_shading_data, umax_read_gain_data
 | 
						|
 | 
						|
    * changed name: umax_read_data_block -> umax_read_image_data
 | 
						|
 | 
						|
    * changed length offest in do_inquiry from 5 to 4
 | 
						|
      and changed set_inquiry_length-offset from 5 to 4
 | 
						|
 | 
						|
    * added calib_lines to structure US and added it to
 | 
						|
      set_window - command in umax-scsi.c
 | 
						|
 | 
						|
    * changed in umax-scsi.c routine identify_scanner:
 | 
						|
      vendor and product is tested for each model instead of
 | 
						|
      vendor=="UMAX " and only model tested!
 | 
						|
      Because of that the format of scanner_str has changed
 | 
						|
      from product,product,...
 | 
						|
      to vendor,product, vendor,product,...
 | 
						|
 | 
						|
    * added support for Linotype Hell Jade (LinoHell Office)
 | 
						|
 | 
						|
    * added empty routine umax_do_calibration in umax-scsi.c, it shall be called
 | 
						|
      after umax_start_scan!
 | 
						|
 | 
						|
    * replaced all umax_*scsi with sanei_*scsi, so the umax-driver
 | 
						|
      now directly calls the sanei_scsi-commands.
 | 
						|
 | 
						|
    * moved sense-handler from umax.c to umax-scsi.c
 | 
						|
      and added detection for driver-calibration-request
 | 
						|
      sense_handler got a new parameter (void *arg).
 | 
						|
 | 
						|
    * changed wait_scanner for SUN: usleep(0.1sec) -> sleep(1s)
 | 
						|
      this is only a bad bugfix that will be replaced one day!
 | 
						|
 | 
						|
 | 
						|
sane-0.69 -> 0.70
 | 
						|
-----------------
 | 
						|
 | 
						|
    * moved reader_process to umax-scsi.c
 | 
						|
 | 
						|
    * changed include <sane/config.h> for _AIX and non-_AIX
 | 
						|
 | 
						|
    * added missing "," in definition line for UMAX Astra 1200S in umax-scanner.h
 | 
						|
 | 
						|
    * added in umax-scsi.c in function identify_scanner a test that only
 | 
						|
      warnings and errors are printed if vendor="UMAX "
 | 
						|
 | 
						|
    * added routine umax_order_line_to_pixel and umax_order_line
 | 
						|
 | 
						|
    * moved reader_process from umax.c to umax-scsi.c
 | 
						|
      and added routine for color ordering.
 | 
						|
 | 
						|
    * reset length offest in do_inquiry from 4 to 5
 | 
						|
      and set_inquiry_length-offset from 4 to 5
 | 
						|
      because umax-S6E didn't work with it!
 | 
						|
 | 
						|
    * corrected error in identify-scanner in vendor-test
 | 
						|
 | 
						|
    * changed end-detection of list of known scanners from
 | 
						|
      #define known_scanners 15 to last item "END_OF_LIST"
 | 
						|
 | 
						|
    * added routine that corrects wrong inquiry-data from
 | 
						|
      Astra 600S and Astra 610S
 | 
						|
 | 
						|
    * added test and selection for do_color_ordering in check_values
 | 
						|
 | 
						|
    * changed __sun-code in umax_wait_scanner because the scsi-driver
 | 
						|
      answers with IOERROR instead of DEVICE_BUSY
 | 
						|
      (this is only a bugfix for a little time)
 | 
						|
 | 
						|
 | 
						|
sane-0.70/0.71 -> 0.72
 | 
						|
----------------------
 | 
						|
 | 
						|
    * inactivated selection of quality calibration (until it is supported
 | 
						|
      by the driver)
 | 
						|
 | 
						|
    * changed maximum x_resolution from optical_res to max_x_res
 | 
						|
 | 
						|
    * reordered DBG-levels and defined them by symbols
 | 
						|
 | 
						|
    * changed all sizes that used type int to type size_t
 | 
						|
 | 
						|
    * changed wait_scanner for testing !sane_status_good,
 | 
						|
      because testing sane_status_device_busy does not work with
 | 
						|
      all scsi-drivers!
 | 
						|
 | 
						|
    * changed ccd-order in umax_order_line, the order is now
 | 
						|
      specified by 9 values (before by 3 values), changed
 | 
						|
      order tables and added a table for Astra 600S and
 | 
						|
      another table for Astra 610S
 | 
						|
 | 
						|
    * changed ccd-order, now based on optical_resolution
 | 
						|
      and added new routine umax_forget_line
 | 
						|
 | 
						|
    * added inquiry-block for UC1200S: NOT TESTED!
 | 
						|
 | 
						|
    * added inquiry-block for UC1260: NOT TESTED!
 | 
						|
 | 
						|
    * included print_inquiry into umax-scsi.c
 | 
						|
 | 
						|
    * added correction-routine for x_res > 600 dpi, phys_width is
 | 
						|
      corrected in umax-scsi.c: bound_scanarea
 | 
						|
 | 
						|
    * changed umax-scsi: sense_handler:
 | 
						|
      changed test for valid sense-block
 | 
						|
      added test for button pressed
 | 
						|
 | 
						|
    * added output of sense-code and error-code in sense_handler
 | 
						|
 | 
						|
    * added options to select calibratin and scan exposure times
 | 
						|
 | 
						|
    * added options to select calibratin and scan lamp density
 | 
						|
 | 
						|
    * moved all option-names/titles/descr. to saneopts.h
 | 
						|
 | 
						|
    * combined bind for highlight, shadow, analog-gamma and new
 | 
						|
      exposure time functions to rgb-bind
 | 
						|
      
 | 
						|
    * added set_WD_line_arrangement(buffer_r, WD_line_arrengement_by_driver);
 | 
						|
      if driver is doing color-ordering from line to pixel
 | 
						|
 | 
						|
    * included umax-scsi.c into umax.c
 | 
						|
 | 
						|
    * included umax-struct.h into umax.h
 | 
						|
 | 
						|
    * included US-structure into Umax_Device-structure
 | 
						|
 | 
						|
    * added free(scanner->device->buffer) to sane_close
 | 
						|
 | 
						|
    * added free(scanner->device->pixelbuffer) to sane_cancel
 | 
						|
 | 
						|
    * added free(scanner->device->pixelbuffer) to do_cancel
 | 
						|
 | 
						|
    * added SANE_UNIT_MICROSECOND to exposure-times
 | 
						|
 | 
						|
    * added output of status-string in wait_scanner
 | 
						|
 | 
						|
    * moved some options for Scan-mode-block to Enhancemant-block
 | 
						|
 | 
						|
sane-0.72 -> 0.73
 | 
						|
-----------------
 | 
						|
 | 
						|
    * disabled RGB_BIND if no such value is available
 | 
						|
 | 
						|
    * included readproc
 | 
						|
 | 
						|
    * included bound_scanarea into check_values, problem
 | 
						|
      with wrong scanarea for UTA should be solved now!
 | 
						|
 | 
						|
    * all scanmode- and scansource-strings are #DEFINEd now
 | 
						|
 | 
						|
sane-0.73 -> 0.74
 | 
						|
-----------------
 | 
						|
 | 
						|
    * added support for 12/36 bits per pixel (for Astra 1220S)
 | 
						|
 | 
						|
    * added support for Astra 1220S
 | 
						|
 | 
						|
    * included inquiry data for UG80 (Escom Image Scanner 256)
 | 
						|
 | 
						|
    * moved WAIT_SCANNER from umax_read_data to umax_read_image_data,
 | 
						|
      umax_read_shading_data now works!
 | 
						|
 | 
						|
    * added umax_start_scan at the end of calibration by driver,
 | 
						|
      the scanner does not hang any more if quality calibration is enabled!
 | 
						|
      There must'nt be a "wait_scanner" in calibration by driver routine!!!
 | 
						|
 | 
						|
    * added usage of driver internal values for calibration by driver if
 | 
						|
      the scanner does not give back the informations about the shading data:
 | 
						|
      width = dev->width * dev->inquiry_optical_res ( * 3 in RGB-mode )
 | 
						|
 | 
						|
    * added 2 calibration-routines:
 | 
						|
      - use last line for shading data
 | 
						|
      - calculate average value for shading data
 | 
						|
      - prepared routine for complex calculation
 | 
						|
 | 
						|
    * added gamma download curve format type 0 and 1
 | 
						|
 | 
						|
    * defined gamma DCF = 1 for UC1200S and UC1260
 | 
						|
 | 
						|
    * defined gamma DCF = 0 for UC1200SE and ARCUS PLUS
 | 
						|
 | 
						|
    * changed sense_handler: if bad sense_key => DEVICE_BUSY
 | 
						|
      problem with black area at top of scan for some SCSI-adapters is solved now
 | 
						|
 | 
						|
    * changed wait_scanner: waits 0.5 sec now
 | 
						|
 | 
						|
    * disabled quality calibration in preview mode
 | 
						|
 | 
						|
    * made upper_left_x and upper_left_y even values
 | 
						|
      it looks like even resolutions > 600 dpi work now!
 | 
						|
      (not ok!!!)
 | 
						|
 | 
						|
    * added sigterm_handler for umax_reader_process
 | 
						|
      changed sane_canel, do_canel and do_eof(=close_pipe),
 | 
						|
      cancel now works!
 | 
						|
     
 | 
						|
    * changed trim_rowbufsize that made problems with SGI,
 | 
						|
      there has been an overflow because of big buffersize
 | 
						|
 | 
						|
      
 | 
						|
sane-0.74 -> 1.00 (build 0)
 | 
						|
---------------------------
 | 
						|
 | 
						|
    * added output of umax-backend-version in sane_init
 | 
						|
 | 
						|
    * added support for Linotype Hell Jade2 (Vobis ScanBoostar Premium)
 | 
						|
      SCSI-ID "LinoHell","Office2"
 | 
						|
 | 
						|
    * changed base of calculation of scanwidth and scanlegth from
 | 
						|
      pixel to resolutionbase (1/300, 1/600 or 1/1200 inch)
 | 
						|
      problem with wrong pixelcount at higher resolutions should be
 | 
						|
      solved now
 | 
						|
 | 
						|
    * changed selection for calibration mode
 | 
						|
 | 
						|
    * changed calculation for width in pixels for lineart and halftone mode
 | 
						|
 | 
						|
    * added inquiry for UMAX UC1200SE
 | 
						|
 | 
						|
    * corrected 12/36-bit-mode in send_gamma_data and array in umax.h
 | 
						|
 | 
						|
    * added support for Gemini D-16
 | 
						|
 | 
						|
 | 
						|
sane-1.00-build-0 -> build-1
 | 
						|
-----------------------------
 | 
						|
 | 
						|
    * added support for Nikon AX-210
 | 
						|
 | 
						|
    * changed all grey to gray (David Mosberger asked for it)
 | 
						|
 | 
						|
    * changed bug in gray gamma table conversion
 | 
						|
 | 
						|
    * added Linotype Hell Saphir 2 as supported scanner
 | 
						|
 | 
						|
    * changed umax-uc1260.h
 | 
						|
 | 
						|
    * added "- 1" in umax_order_line:
 | 
						|
      else if (dev->pixelline_opt_res < length * 3 - CCD_distance * 3 - 1)
 | 
						|
      else if (dev->pixelline_opt_res < length * 3 - CCD_distance - 1)
 | 
						|
 | 
						|
    * changed all allloca() to malloc() + free()
 | 
						|
 | 
						|
    * removed options speed and smear, I got the info from umax that
 | 
						|
      these values should never be changed!
 | 
						|
 | 
						|
    * removed ten_bit_mode and twelve_bit_mode options, added option bit_depth
 | 
						|
      and added support for 9, 14 and 16 bpp
 | 
						|
 | 
						|
    * replaced u10_range and u12_range by dynamically set scanner.output_range
 | 
						|
 | 
						|
    * removed static allocation for gamma_table[0..3], this is done dynamically
 | 
						|
      in sane_open and freed in sane_close now.
 | 
						|
 | 
						|
    * added an empty string to the end of scan_mode_list and source_list
 | 
						|
 | 
						|
build-1 -> build-2
 | 
						|
------------------
 | 
						|
 | 
						|
   * added "*info |= SANE_INFO_RELOAD_PARAMS;" in control_option set bit_depth
 | 
						|
 | 
						|
   * added inverted calibration modes for Astra 6X0S scanners.
 | 
						|
 | 
						|
 | 
						|
build-2 -> build-3 (sane-1.0.1)
 | 
						|
-------------------------------
 | 
						|
 | 
						|
   * inversion of calibration is automatically set for Astra 6X0S and Vista S6E
 | 
						|
 | 
						|
   * check for machine endianess is done only at backend start now!
 | 
						|
 | 
						|
   * made umax_do request_sense static
 | 
						|
 | 
						|
 | 
						|
build-3 -> build-4
 | 
						|
------------------
 | 
						|
 | 
						|
   * Added option name and parameter in debug output in option set value
 | 
						|
 | 
						|
   * Added option name in debug output in option get value
 | 
						|
 | 
						|
   * Changed calculation of pixels/line and lines, may be the problem
 | 
						|
     with shaered images at resolutions>600 dpi is solved now
 | 
						|
     later Remark: This error does still occur, but not so often!
 | 
						|
 | 
						|
 | 
						|
build-4 -> build-5
 | 
						|
------------------
 | 
						|
 | 
						|
   * Changed calculation in umax_order_line, color images should
 | 
						|
     have the correct length now for Astra 6X0S and Vista S6E
 | 
						|
 | 
						|
   * Added DOR resolutions and area
 | 
						|
 | 
						|
 | 
						|
build-5 -> build-6
 | 
						|
------------------
 | 
						|
 | 
						|
   * Bits for ADF and UTA in driver internal inquiry block (old UMAX scanners)
 | 
						|
     are set dynamically now.
 | 
						|
 | 
						|
   * Added Genius ColorPage-HR5 (vendor KYE) (=Astra 1200S) as supported scanner
 | 
						|
 | 
						|
   * Added Astra 2400S as experimentally supported scanner
 | 
						|
 | 
						|
   * Added pauses for Astra 2400S
 | 
						|
 | 
						|
   * Removed reposition_scanner at start of scan, Astra 2400S does not work with it!
 | 
						|
 | 
						|
   * changed debug output in correct_inquiry
 | 
						|
 | 
						|
   * for UMAX S12 the driver does not wait any more until scanner is repositioned
 | 
						|
     this is experimental, it may work with other scanners too!
 | 
						|
 | 
						|
 | 
						|
build-6 -> build-7
 | 
						|
------------------
 | 
						|
 | 
						|
   * changed some int -> unsigned int (resolution and scanwidth etc)
 | 
						|
 | 
						|
   * calculate_pixel is called with right values in UTA mode now.
 | 
						|
 | 
						|
   * if DOR resolution is not defined and DOR is available
 | 
						|
     the DOR resolution is set to double standard resolution
 | 
						|
 | 
						|
   * removed wait_scanner after set_window-command
 | 
						|
 | 
						|
   * added Mirage D16-L as supported scanner
 | 
						|
 | 
						|
   * Astra 2400S works stable now
 | 
						|
 | 
						|
 | 
						|
build-7 -> build-8
 | 
						|
------------------
 | 
						|
 | 
						|
    * for Mirage D-16L the driver does not wait any more until scanner is repositioned
 | 
						|
      this is experimental, it may work with other scanners too!
 | 
						|
 | 
						|
    * Mirage D-16L does not give back informations for calibration by driver,
 | 
						|
      added new modus that "guesses" the values for Mirage D-16L.
 | 
						|
 | 
						|
    * Added read_shading_data to 16 bit calibration routine and made a routine for
 | 
						|
      averaging with low byte first and one for high byte first
 | 
						|
 | 
						|
    * Byte order (HBT) is set always (also in lineart and halftone)
 | 
						|
      because it is used in driver calibration
 | 
						|
 | 
						|
    * Added relevant_*_res the is set to normal or double resolution values
 | 
						|
 | 
						|
    * Added test if scsi buffer is large enough for one shading line
 | 
						|
 | 
						|
    * selection for Calibration mode, Shading type and Speed/Smear
 | 
						|
      are only compiled in if define is set in umax.h
 | 
						|
 | 
						|
 | 
						|
build-8 -> build-9
 | 
						|
------------------
 | 
						|
 | 
						|
    * slow speed options is preset for Vista T-630
 | 
						|
 | 
						|
    * speed/smear can be set now (forgotten #ifdef)
 | 
						|
 | 
						|
    * selection of exposure times now is only available if it is enabeld
 | 
						|
 | 
						|
    * gamma table is disabled in lineart and halftone modes
 | 
						|
 | 
						|
    * if image is transmitted completly sane_read (close_pipe)
 | 
						|
      returns with SANE_STATUS_GOOD in adf mode and in any other case
 | 
						|
      with SANE_STATUS_EOF
 | 
						|
 | 
						|
 | 
						|
build-9 -> build-10
 | 
						|
-------------------
 | 
						|
 | 
						|
    * removed change about sane_read returns SANE_STATUS_GOOD in ADF mode
 | 
						|
 | 
						|
    * transformed all gif files into jpeg format because of all the
 | 
						|
      trouble about the gif licence. Will never use gif again!
 | 
						|
 | 
						|
    * added correction for inquiry-ADF-bit for Astra 2400S
 | 
						|
 | 
						|
    * added second test method to detect ADF error in sane_start:
 | 
						|
      inquiry block is read and cover open, jammed and no paper is tested
 | 
						|
 | 
						|
 | 
						|
build-10 -> build-11
 | 
						|
--------------------
 | 
						|
 | 
						|
    * test for adf errors (sane_start) is now only done if adf is selected
 | 
						|
 | 
						|
 | 
						|
build-11 -> build-12
 | 
						|
--------------------
 | 
						|
 | 
						|
    * moved adf error tests from sane_start to umax_start_scan
 | 
						|
 | 
						|
    * sane_control_option: printing option name is set to "(none)" if pointer is NULL
 | 
						|
 | 
						|
    * added error message after each call of sanei_scsi_cmd
 | 
						|
 | 
						|
    * changed manipulation of ADF bit for Astra 2400S in umax_correct_inquiry
 | 
						|
      from dev->adf to set_inquiry_sc_adf()
 | 
						|
 | 
						|
 | 
						|
build-12 -> build-13
 | 
						|
--------------------
 | 
						|
 | 
						|
    * changed inquiry data of UC1200SE
 | 
						|
 | 
						|
    * added set_inquiry_CBHS(50) in correct_inquiry for UC1200SE
 | 
						|
 | 
						|
    * correct_inquiry is called for scanners with short inquiry now
 | 
						|
 | 
						|
    * dev->inquiry_max_calib_lines is preset to 66,
 | 
						|
      problem with Vist S6E V1.6 should be solved this way.
 | 
						|
 | 
						|
    * inquiry block parameters > 0x93 are only used if block is long enough
 | 
						|
 | 
						|
 | 
						|
build-13 -> build-14
 | 
						|
--------------------
 | 
						|
 | 
						|
    * changed inquiry_cbhs_[min,max] -> inquiry_[contrast, brightness, threshold,
 | 
						|
      highlight, shadow]_[min,max] and set correct values for CBHS_255 and CBHS_50
 | 
						|
 | 
						|
    * changed cbhs_str[CBHS_50] from "78-178" to "0-50"
 | 
						|
 | 
						|
    * changed umax-uc1200se.h inquiry byte 0x64 bit 5 to 0 (gamma download format != 2)
 | 
						|
      and wdb len from 0x30 to 0x31
 | 
						|
 | 
						|
    * disabled halftone pattern download, and halftone dimension selection - not ready
 | 
						|
      preselected is a 8x8 built in halftone pattern
 | 
						|
 | 
						|
    * removed set_inquiry_CBHS(50) from correct_inquiry for UC1200SE
 | 
						|
 | 
						|
    * added "Astra 2200 " as supported scanner
 | 
						|
 | 
						|
    * added cast from (void *) to (unsigned char*) in umax_send_gamma_data
 | 
						|
 | 
						|
 | 
						|
build-14 -> build-15
 | 
						|
--------------------
 | 
						|
 | 
						|
    * add "(unsigned)" to option number test in sane_control_option
 | 
						|
 | 
						|
    * for Astra 1200 the driver does not wait any more until scanner is repositioned
 | 
						|
      this is experimental, it may work with other scanners too!
 | 
						|
 | 
						|
 | 
						|
build-15 -> build-16
 | 
						|
--------------------
 | 
						|
 | 
						|
    * OPT_SOURCE: removed change of width/height and "*info |= SANE_INFO_RELOAD_PARAMS;"
 | 
						|
      from get_value to set_value and added "*info |= SANE_INFO_RELOAD_OPTIONS;"
 | 
						|
     
 | 
						|
 | 
						|
build-16 -> build-17
 | 
						|
--------------------
 | 
						|
 | 
						|
    * changed calibration mode from SHADING_TYPE_AVERAGE_INVERT to SHADING_TYPE_AVERAGE
 | 
						|
      for UMAX S-6E, UMAX S-6EG and Vista-S6E
 | 
						|
 | 
						|
    * changed several int -> unsigned int
 | 
						|
 | 
						|
    * added support for sanei_scsi_open_extended and variable scsi buffer size
 | 
						|
 | 
						|
 | 
						|
build-17 -> build-18 (sane-1.0.2)
 | 
						|
---------------------------------
 | 
						|
 | 
						|
    * some cosmetic changes of the form
 | 
						|
        if (..) {...}
 | 
						|
      =>
 | 
						|
        if (..)
 | 
						|
        {
 | 
						|
          ...
 | 
						|
        }
 | 
						|
 | 
						|
    * removed unnecessary SHADING_TYPE-handling routines for UMAX S-6E, UMAX S-6EG and Vista-S6E
 | 
						|
 | 
						|
    * scsi buffer is only reallocated when size has changed
 | 
						|
 | 
						|
 | 
						|
build-18 -> build-19
 | 
						|
--------------------
 | 
						|
 | 
						|
    * added UMAX PowerLook III as supported scanner
 | 
						|
 | 
						|
    * added EPSON Perfection600 as supported scanner (is a Astra 1200S)
 | 
						|
 | 
						|
    * type of option 0 (Option numbers) is set to SANE_TYPE_INT now (undefined before)
 | 
						|
 | 
						|
    * removed bug that mixed 12 bit and 14/16 bit gamma table when 14 or 16 bit are supported
 | 
						|
      and changed value range of grey custom gamma table:
 | 
						|
      - maximum output value is 255 for 8 bits/pixel
 | 
						|
      - maximum output value is 65535 for 9-16 bits/pixel
 | 
						|
      the custom gamma table does work now with 9-16 bits/pixel output mode
 | 
						|
 | 
						|
    * added routine that reverses bit order in lineart mode when scanner sends LSB first in lineart
 | 
						|
 | 
						|
 | 
						|
build-19 -> build-20
 | 
						|
--------------------
 | 
						|
 | 
						|
    * added variable calibration_width_offset, Mirage D-16L offset of 308 is defined there
 | 
						|
      and added offset of 28 for PowerLook III
 | 
						|
 | 
						|
    * umax_do_calibration: guessed calibration data vaules use 2 bytes/color if scanner
 | 
						|
      supports gamma input bit depth supports 2 bytes/color
 | 
						|
 | 
						|
    * calibration by driver now does work for PowerLook III
 | 
						|
 | 
						|
    * added function umax_set_rgb_bind() that sets the sensitivity of some options
 | 
						|
      that make available different settings for RGB. This function now is called
 | 
						|
      when scanmode is selected.
 | 
						|
 | 
						|
    * changed some int to unsigned int
 | 
						|
 | 
						|
    * made dev->pause_after_reposition = -1; as default, so as default sane-umax does not wait
 | 
						|
      any more while the scanhead is moving back - this may break the support of some scanners
 | 
						|
      so it may have to be changed (dev->pause_after_reposition = 0;) for some scanners.
 | 
						|
      reported to work for:
 | 
						|
      - Supervista S12
 | 
						|
      - PowerLook III
 | 
						|
      - Astra 2200
 | 
						|
 | 
						|
 | 
						|
build-20 -> build-21 (sane-1.0.3)
 | 
						|
---------------------------------
 | 
						|
 | 
						|
    * Added Linotype "JADE" as supported scanner
 | 
						|
 | 
						|
    * Removed bug in sane_close that caused segfault when
 | 
						|
      sane_close was called twice with the same scanner handle
 | 
						|
 | 
						|
build-21 -> build-22
 | 
						|
--------------------
 | 
						|
 | 
						|
    * replaced fgets() by sanei_config_read()
 | 
						|
 | 
						|
    * added command queueing for scsi read commands
 | 
						|
      - removed WAIT_SCANNER scsi command call after read command
 | 
						|
      - the additional buffers are allocated in the reader process
 | 
						|
      - the number of buffers can be defined in umax.conf
 | 
						|
        with option scsi-maxqueue [1..8] default:2
 | 
						|
      (did some tests with Supervista S12 and PowerLook III
 | 
						|
       on the same scsi controller (ncr53c810):
 | 
						|
       command queueing works, it is possible to start
 | 
						|
       both scanners at the same time. The scanner with the
 | 
						|
       higher scsi-ID (=priority) does scan without stops,
 | 
						|
       the other scanner has to wait long time between the
 | 
						|
       scsi-read commands, it also is possible to give
 | 
						|
       bothe scanners different scsi command queueing depth).
 | 
						|
 | 
						|
    * prepared replacement of pipe by sanei_ipc_* routines 
 | 
						|
 | 
						|
    * added routines umax_get_lamp_status and umax_set_lamp_status
 | 
						|
 | 
						|
    * updated inquiry output (new bits from powerlook scsi protocol 1.0 X101)
 | 
						|
 | 
						|
    * added new (powerlook scsi protocol 1.0 X101) window descriptor block entries to umax-scsidef.h
 | 
						|
 | 
						|
    * added button protocol (3 buttons, from powerlook scsi protocol 1.0 X101)
 | 
						|
 | 
						|
    * added button "lamp off" to turn off scanner lamp
 | 
						|
      (this option may be remoeved again in later version, may be
 | 
						|
       it will be replaced by an autmatic lamp turn off function)
 | 
						|
 | 
						|
    * added options to umax.conf
 | 
						|
      lamp-off-at-exit [01] default:0
 | 
						|
      lamp-off-time [10..720] (in minutes) default:30
 | 
						|
 | 
						|
    * if  lamp_off_at_exit == 1 and lamp_control_available == 1
 | 
						|
      the scanner lamp is turned off in sane_close
 | 
						|
 | 
						|
    * renamed umax-scanner.h and umax-"scannername".h to umax*.c
 | 
						|
      because these files create data code
 | 
						|
 | 
						|
 | 
						|
build-22 -> build-23
 | 
						|
--------------------
 | 
						|
 | 
						|
    * scsi commands set/get lamp control are send with a command length of
 | 
						|
      10 bytes instead of 6 bytes and control bit #7 is in byte 0x03
 | 
						|
      and not in byte 0x04 (it is described incorrect in the umax doc)
 | 
						|
 | 
						|
    * enabled lamp control for Astra 2200
 | 
						|
 | 
						|
    * removed umax.conf options lamp-off-at-exit and lamp-off-time
 | 
						|
 | 
						|
    * added frontend option lamp-off-at-exit
 | 
						|
 | 
						|
    * added frontend option lamp-on
 | 
						|
 | 
						|
    * forcing calibration_bytespp = 1 for Astra 2200 - quality calibration does work now
 | 
						|
 | 
						|
    * for Astra 2200 selection for different x/y resolutions is disabled
 | 
						|
 | 
						|
    
 | 
						|
build-23 -> build-24 (sane-1.0.4)
 | 
						|
--------------------
 | 
						|
 | 
						|
    * forcing calibration_bytespp = 1 for Astra 2100S
 | 
						|
 | 
						|
    * Added Astra 2100S as supported scanner
 | 
						|
 | 
						|
    * enabled lamp control for Astra 2100S (don`t know if this works, is a test)
 | 
						|
 | 
						|
    * Added warning in sane_control_option if option could not be set
 | 
						|
 
 | 
						|
    
 | 
						|
build-24 -> build-25
 | 
						|
--------------------
 | 
						|
 | 
						|
   * dev->lamp_control_available is preset to 0
 | 
						|
 | 
						|
   * dev is erased (0) after it is allocated
 | 
						|
 | 
						|
   * added special options for PowerLook 3000:
 | 
						|
     - calibration is done for each CCD pixel
 | 
						|
     - calibration_bytespp is set to 1
 | 
						|
     the scanner still is not listed as supported scanner because
 | 
						|
     the changes are not tested
 | 
						|
 | 
						|
   * added options that are read from umax.conf:
 | 
						|
 | 
						|
     - execute-request-sense:
 | 
						|
       values: 0=disabled, 1=enabled, default=0
 | 
						|
       If set to 1 umax_do_request_sense is called in umax_do_calibration.
 | 
						|
       This can hang the system (but has been enabled until this version)
 | 
						|
 | 
						|
     - scsi-buffer-size-min, scsi-buffer-size-max:
 | 
						|
       values: 4096-1048576, default min=65536, max=131072
 | 
						|
 | 
						|
     - scan-lines, preview-lines:
 | 
						|
       values: 1-65535, default scan-lines=40, preview-lines=10
 | 
						|
       define the maximum number of lines that are scanned into one buffer
 | 
						|
 | 
						|
     - force-preview-bit-rgb:
 | 
						|
       values: 0=disabled, 1=enabled, default=0
 | 
						|
       set preview bit in rgb real scan
 | 
						|
 | 
						|
     - slow-speed, care-about-smearing:
 | 
						|
       values: -1=auto, 0=disabled, 1=enabled, default=-1
 | 
						|
       dangerous options, needed for some scanners
 | 
						|
 | 
						|
     - calibration-full-ccd:
 | 
						|
       values: -1=auto, 0=disabled, 1=enabled, default=-1
 | 
						|
       do calibration for each pixel of ccd instead of selected image
 | 
						|
 | 
						|
     - calibration-width-offset:
 | 
						|
       values: -1=disabled, >=0 set value
 | 
						|
       add an offset width to the calculated with for image/ccd
 | 
						|
 | 
						|
     - calibration-bytes-pixel:
 | 
						|
       values: -1=disabled, 0=not set, 1=1 byte/pixel, 2=x bytes/pixel
 | 
						|
       use # bytes per pixel for calibration
 | 
						|
 | 
						|
     - invert-shading-data:
 | 
						|
       values: -1=auto, 0=disabled, 1=enabled, default=-1
 | 
						|
       invert shading data before sending it back to the scanner
 | 
						|
 | 
						|
     - lamp-control-available:
 | 
						|
       values: 0=automatically set by driver - if known, 1=available, default=0
 | 
						|
 | 
						|
   * updated html-documentation
 | 
						|
 | 
						|
   * updated sane-umax.man
 | 
						|
 | 
						|
   * added pre focus options (PowerLook 3000):
 | 
						|
     - FP  - fix focus position
 | 
						|
     - FDC - lens calibration in doc position
 | 
						|
     - PF  - disable pre focus
 | 
						|
     - LCL - use 0.6/0.0mm holder focus position
 | 
						|
 | 
						|
   * added #define SANE_I18N(text) text to umax.c. This is to mark the backend
 | 
						|
     specific texts that shall be translated by the frontend
 | 
						|
 | 
						|
 |