# For documentation see sane-mustek_pp(5) # # Scanner definition template: # # scanner # option ? # option ? # ... # # where: # # is an arbitrary name for the scanner (eg. Mustek-1200CP) # # is the parallel port to which the scanner is connected # Possible values are 0x378, 0x278, and 0x3bc. For Linux, the # mapping between ports an numbers is different for kernel # version 2.2 and 2.4. Port 0x378 corresponds to lp0 on 2.4 kernel. # # is an identification of the scanner type. # Possible values are: # - cis600 (for Mustek 600CP & OEM versions), # - cis1200 (for Mustek 1200CP & OEM versions), # - cis1200+ (for Mustek 1200CP+ & OEM versions), # - ... (non-CIS versions will be added in the future) # # is a name of an option, and an optional value # for the option. # Currently available options for *CIS* type scanners are: # - top_adjust : # Vertical adjustment of origin, in millimeter. # Values between -5.0 and +5.0 mm are possible # (floating point). # Default: 0.0 # - slow_skip: # Boolean option. Disables fast skipping to the start # of the scan region. May be necessary in case fast # skipping results in inaccuracies. # Default: fast skipping enabled # - bw : # Black/white discrimination value for lineart scans. # Pixel values below that value are considered black, # others are considered white. Range: 0-255. # Default: 127 # # # Example for a LifeTec LT9350 (Mustek 1200CP clone): # # scanner LT9350 0x378 cis1200 # option top_adjust 0 # option bw 127 # # # Uncomment/customize to your needs # # scanner Mustek-600CP 0x378 cis600 # scanner Mustek-1200CP 0x378 cis1200 # scanner Mustek-1200CP+ 0x378 cis1200+ #