resulted in black images on some Paragon 6000SP scanners. Added
option to disable backtracking. New version: 1.0-109.
Henning Meier-Geinitz <henning@meier-geinitz.de>
* backend/mustek.CHANGES backend/umax.CHANGES backend/umax.FAQ
backend/umax.TODO: Moved to doc/mustek respectively doc/umax.
* doc/canon.CHANGES doc/canon.install2700F.txt doc/canon:
Moved canon-specific documentation to doc/canon.
* doc/mustek: New subdirectory for mustek-specific documentation.
* doc/sane-umax*.html doc/sane-umax*.jpg doc/sane-umax-doc.tex
doc/sane-umax-doc.dvi doc/umax: Moved all the umax-specific
documentation to new subdirectory umax.
* backend/agfafogus.c: Moved PATH_MAX after sanei_backend.h include
to avoid warning. Changed printf to DBG.
* backend/mustek.c backend/mustek.CHANGES backend/mustek.desc: Added
support for translating options. Used only PACKAGE_VERSION for
output. Updated email address. New version: 1.0-107.
* include/sane/sanei_backend.h include/sane/saneopts.h: Added macro
SANE_I18N. It's used to mark strings that can be translated and
used by a frontend. Usually these are option titles and descriptions
as well as the contents of string lists. Used this macro to mark
the translatable strings in saneopts.h. More translation support
will follow.
* backend/mustek.c backend/mustek.desc backend/mustek.CHANGES
Added detection of the TA for the Paragon 1200 SP Pro. Added
warning about not supported Trust scanners. Changed description
of contarst and brightness settings. Backend status is "stable"
now. New version: 1.0-106.
* acinclude.m4 aclocal.m4: Fixed comment concerning dc240.
* configure configure.in include/sane/config.h.in: Added test for
socklen_t in sys/socket.h. This fixes the compilation problem on
Irix.
* doc/sane-avision.man doc/sane-ricoh.man doc/sane-s9036.man
doc/sane-tamarack.man: find-scanner is now called
sane-find-scanner and installed on the system so it's not
necessary to point to the tools directory.
* frontend/scanimage.c: Fixed too long line in output.
* sane-config.in: Name is sane-config again (was sane-backends-config
due to the renaming of the package).
* TODO: Removed entry about net.c not compiling on Irix and
references to find-scanner in the man pages. Updated numbers of
the compilation warnings. Still too many, however.
* backend/mustek.c backend/mustek.desc backend/mustek.h
backend/mustek.CHANGES: Fixed grascale gamma for the 600 II N.
Fixed ADF problems when selecting windows smaller than the
whole scan area. Fixed linedistcnace corrections issues concerning
ADF and concerning 1200SP V 1.00. New version: 1.0-105.
* backend/mustek.c backend/mustek.desc backend/mustek.h
backend/mustek.CHANGES doc/sane-mustek.man:
Added 36 bit mode for Pro models. Removed support for "special"
modes, used options instead. Code cleanup. Updated manpage
concerning sane-find-scanner. New version: 1.0-104.
* configure: regenerated from configure.in.
* backend/mustek.CHANGES backend/mustek.c backend/mustek.desc
backend/mustek.h doc/sane-mustek.man: Added calibration for Pro
scanners and the SE 12000 SP Plus. Added option to use the full
legal size of the Paragon 1200 LS scanner. Added fast preview for
Pro scanners. Bug fixes. New version: 1.0-103.
* backend/mustek.c backend/mustek.desc backend/mustek.CHANGES:
Fixed wrong comment in encode_resolution. Added missing test for
return status in sane_start. Fixed wrong calculation of tlx and
tly for Pro series scanners. Increased version number.
* NEWS: Updated backend versions. Added point about compilation fixes
on Irix and FreeBSD.
* backend/mustek.c backend/mustek.desc backend/mustek.CHANGES:
Fixed problem with lamp control of SE scanners and reduced
length of scan area for Paragon 1200 SP PRO. Removed warning for
this scanner. Increased version number.
* AUTHORS: Added Karsten Festag as maintainer of microtek2.
* backend/mustek.* doc/sane-mustek.man: Update to Mustek backend
1.0-100. Added option fast-preview that tries to use the fastest
mode available for preview. This is supported for the 3-pass
scanners (was option "preview in gray") and some of the
ScanExpress scanners (6000 SP, 12000 SP Plus). Use #include
"../include/sane/...". Put option force-wait into mustek.conf
(disabled). Removed block mode for Paragon 6000 SP and 8000 SP.
Code cleanup. More debug output. Details in backend/mustek.CHANGES.
* doc/.cvsignore: Added sane-as6e.5 and sane-nec.5.
* TODO: Updated. Added entries for viceo backend and addition to hp
backend. Updated entries about the include issue. Added point about
additional options for pnm backend, install problem of libsane.la,
and some build problems and the --without-x problem. Some more
details for detecting older SANE versions.
* LEVEL2: Added entry about sending messages from backend to frontend.
Removed entry about image polarity.
* backend/mustek.c backend/mustek.h backend/mustek.CHANGES
backend/mustek.desc: Update to Mustek backend 1.0-99. Better
transparency adapter support for ScanExpress scanners. Changed
color support for ScanExpress scanners (faster at some resolutions
now). Paragon 1200 SP color mode should work now without garbage at
the end of an image. Some bugfixes. Details in
backend/mustek.CHANGES.
* tools/find-scanner.c: Explicitly state that find-scanner won't
find non-SCSI scanners.
* doc/scanimage.man: Add examples for SANE device names.
* frontend/scanimage.c: Output message when no devices are found.
Add example for devicename to --help message. Print warning
when a Unix devicename is used instead of a SANE device. Removed
compiler warning.
* TODO: Removed entries about the fgets and include issues in
umax. Removed entries about scanimage device name
documentation. Added a point about xscanimage problems with the
new GIMP API.
* backend/mustek.* doc/sane-mustek.man: Update to Mustek backend
1.0-98. Fixed segmentation fault in sane_init. Enabled double
buffering. Clear inquiry buffer before using. Paragon 1200 SP now
uses LD_BLOCK color correction. Removed LD MFS (wasn't used
anymore). Fix sane_cancel for Paragon series II scanners. Fix
halftone and grain for Paragon series II scanners. Backtracking is
used automaticly by all scanners now. Some safety checks, code
cleanup and more debug output. Details are in
backend/mustek.CHANGES.
* backend/mustek.*: Update to Mustek backend 1.0-97. This is a
development version and is only tested for three-pass scanners.
Added support for Paragon 1200 SP Pro and ScanExpress A3 SP.
Removed detection of " C04" and " C12" (don't seem to exist).
Changed SCSI request scheme. Sane_read can read more than 4096
bytes from pipe. Minimum dpi is 30 now. Fixed LD correction for
Paragon 1200SP 1.06 and 1.11. Read SCSI buffer into big block and
do LD after that for Paragon one-pass scanners. New option
"blocksize" in mustek.conf. Better detection of the scanner type
(three-pass, Paragon I, ...). Fixed possible segmentation faults
in Paragon 600 II N LD code, scsi_sense_wait_ready and
sense_handler. Decreased maximum scan size of Paragon 800 II
SP. For three-pass scanners: fixed stop_scan and speed code, scan
area is in pixels now, added RGB brightness and contrast, use
+-100% for brightness and contrast. Return SANE_STATUS_CANCELLED
when scan was cancelled. Option "force backtracking" is enabled by
default, "scan speed" is set to "fastest". Added option
"force-warn" for mustek.conf. Rewrote halftone mode. Better error
handling and more debug output.
* TODO: Clarified point about image data polarity. Moved point about
xscanimage not updating the progress bar for 3pass scanners to
frontend section. Removed umax entry in "frontends". Removed entry
about alpha channel (was added to LEVEL2 file).
* LEVEL2: Add point about image data polarity.
* frontend/scanimage.c: Removed some warnings.
backend/canon_pp-dev.h: Many changes: Bug fixes, less memory leaks (none left now?), more relaible, faster. Biggest changes are speculative reads (ask scanner to read more while data processing
occurs) and more reliable sending of commands. Slight performance
increase over previous version.
* doc/sane-canon_pp.man: Added discussion noting that scanning
greyscale in green is bad for colour.
models. Also corrected typo which caused full bed scans to fail. Disabled
problematic detect for now, will make detection slightly slower. Patch from
Matthew Duggan <stauff1@users.sourceforge.net>.
Henning Meier-Geinitz <henning@meier-geinitz.de>
* NEWS: Updated for SANE 1.0.4. Please check.
* README.aix: Removed paragraph about shared libs not working.
* README.linux: Added paragraph about excessive warnings due to glibc
bug (from Peter Kirchgessner).
* TODO: Removed entry about shared libs not working on AIX. Added entry
about PTAL checks. Removed entry about DBG and microtek2. Added entry
about dc210 and jpeg functions. Added entry about using strchr()
instead of index().
* sane.lsm: Added NEC.
* backend/microtek2.c: (from karsten.festag@t-online.de (Karsten
Festag)) Use DBG instead of printf/fprintf. Use
#include "../sane/include/..." instead of #include "sane/...". Fixed
warnings.