Wykres commitów

2591 Commity (e4e7e71db6247e482d53f73de44f05f214869975)

Autor SHA1 Wiadomość Data
Mattias Ellert e4e7e71db6 New date for good libusb from CVS 2005-09-17 04:48:55 +00:00
Mattias Ellert 007bd9e9f6 Fix disabling of locking when locking group does not exist 2005-09-07 16:50:02 +00:00
Henning Geinitz ee26d224ec Added Genius ColorPage Slim 1200. 2005-09-07 15:54:57 +00:00
Oliver Schirrmeister d79d95d0aa bugfixes for the M3092, enabled dropoutcolor for all fi-* scanners.
Tested with the fi-5650
2005-09-07 11:44:45 +00:00
Henning Geinitz f3d0b6f763 Updated Russian translation (from Vitaly Lipatov <LAV@vl3143.spb.edu>). 2005-09-05 20:02:53 +00:00
Oliver Schwartz 304b667a6a Fixed debugging code for epson scanners 2005-09-03 10:52:11 +00:00
Henning Geinitz e790e335e8 Added HP PSC 750. 2005-09-02 19:06:11 +00:00
Henning Geinitz 8b797c6eb6 Added Epson Perfection 4490 Photo. 2005-09-02 18:52:18 +00:00
Henning Geinitz 149b4c3923 Added detection for SQ113 chip (e.g. Mustek BearPaw 2448 TA Pro). 2005-09-01 20:41:12 +00:00
Henning Geinitz aa209997b7 Genius ColorPage Vivid 1200 X is reported to work. Genius ColorPage Vivid 4 XE
seems to be the same as 4 X, it just doesn't have buttons. Cleanup of .desc
file. Fixed gain setting. Mustek ScanExpress A3 USB 600 dpi color scanning works
now.
2005-09-01 20:01:50 +00:00
Henning Geinitz 5c4b3d9a0e Mustek BearPaw 2448 TA Pro has status "good" now. 2005-08-31 20:45:53 +00:00
Henning Geinitz e401121ef1 Removed Mustek 1800 A3 Pro (this is actually a P3600 A3 Pro). 2005-08-31 20:44:47 +00:00
Henning Geinitz e80ac97c60 New external Backend for Mustek BearPaw 2448 TA Pro. 2005-08-30 20:22:27 +00:00
Henning Geinitz 1c9f419660 Removed Mustek BearPaw 2448 TA Pro (now supported by external Mustek USB2
backend). Added comments about that backend to some other scanners that may be
supported later.
2005-08-30 20:21:26 +00:00
Henning Geinitz e51df58fc8 Canon LiDE 60 is GL841 based. 2005-08-29 16:43:43 +00:00
Henning Geinitz 8f789e594c Changed status of Canon 636u too "good". 2005-08-28 14:37:33 +00:00
Henning Geinitz f191ed670d Brother MFC-5440CN is reported to work (bug #302105). 2005-08-27 11:06:57 +00:00
Stéphane Voltz 8c463cfb76 - added EPP support for UMAX Astra 610P 2005-08-24 05:35:06 +00:00
Henning Geinitz 492e322adf Added Canon LiDE 60. Reflecta Digitdia 3600 is not GL841-based. 2005-08-23 16:30:28 +00:00
Stéphane Voltz f9f48fafa4 - Added rts8858c (used by lexmark X1100 series) detection 2005-08-22 18:59:26 +00:00
Henning Geinitz d202ddbe93 Mention problems with library names. 2005-08-22 17:18:26 +00:00
Henning Geinitz 821ca4d53c Added some Genius scanners. Fixed Visioneer Onetouch 7300 USB. Added Plustek
OpticSlim 2400.
2005-08-22 15:48:48 +00:00
Gerhard Jaeger e65d96c5b0 * doc/plustek/Plustek-USB.changes: Update.
* backend/plustek.c: Bumped build number.
* backend/plustek-usb.c backend/plustek-usbscan.c: Fixed problem,
  when trying to scan at resolutions beyond the optical one
  (sensor stops too early).
* tools/hotplug/libsane.usermap: Added USB ID for LiDE25.
2005-08-22 07:29:14 +00:00
Henning Geinitz dc9efdd920 Marked microtek2 backend as unsupported. Changed link to point to old website
directly. Listed Microtek ScanMaker 9800XL as supported (bug #301515).
2005-08-21 14:41:54 +00:00
Mattias Ellert dcec1b5385 Updated from libtool 1.5.18. 2005-08-21 08:12:42 +00:00
Henning Geinitz 93d43e0be8 Increased number limit of scanners that can work with this backend to 50. Added
support for Genius ColorPage Vivid 1200 X (untested).
2005-08-20 17:54:34 +00:00
Henning Geinitz 46be471fd0 Disabled link to backend homepage which doesn't seem to contain anything
sane-related.
2005-08-19 15:59:01 +00:00
Henning Geinitz 3c38ba02f4 Enabled GT68XX_FLAG_NO_STOP for Mustek BearPaw 2400 CU Plus. Some of these
scanners don't seem to like that command.
2005-08-19 15:54:31 +00:00
Henning Geinitz e50187fb8f Fixed check for usbcalls.h on OS/2 (patch from Paul Smedley <paul@smedley.info>). 2005-08-19 15:26:50 +00:00
Gerhard Jaeger 269fd05fb2 * doc/plustek/Plustek-USB.changes: Update.
* backend/plustek-usb.h backend/plustek-usbdevs.c: Removed obsolete
  _WAF_BLACKFINE. LiDE20 does not seem to have a reliable black
  calibration area, so the devices now will switch off the lamp
  for dark calibration.
* backend/plustek-usbcal.c backend/plustek-usbscan.c: Cleanup.
* backend/plustek-usbshading.c: Fixed line statistics and added
  calibration data output.
* backend/plustek.c: Bumped build number.
2005-08-19 11:56:52 +00:00
Henning Geinitz b19e6c5262 Fixed the problem concerning scanning on *BSD. Scanning only worked once (bug
#300597). Fixed compilation warnings.
2005-08-18 19:26:09 +00:00
Henning Geinitz 9f9339fd92 Min. libusb version is 0.1.8. 2005-08-17 18:01:37 +00:00
Julien BLACHE 94ad270193 Added USB IDs for the sm3600-supported scanners. If you know the exact model name corresponding to the above IDs, please mail sane-devel:
0x05da/0x40b3, 0x05da/0x40b8, 0x05da/0x40ca, 0x05da/0x40dd, 0x05da/0x40ff
2005-08-17 16:36:49 +00:00
Henning Geinitz 621dc84b90 Added check for Toshiba M011 chips as used in Microtek ScanMaker 3600, 3700, and
3750.
2005-08-16 20:28:46 +00:00
Oliver Schwartz 0f98b4adfe Removed C++-style comment 2005-08-16 20:15:10 +00:00
Henning Geinitz a2f1183de1 Removed direct dependence of sm3600 on libusb. Used sanei_usb instead. Based on
patch from Francois Revol <revol@free.fr>.  Updated documentation
accordingly. Fixed compilation warnings.
2005-08-16 19:50:34 +00:00
Henning Geinitz ee11f5abcf Added check for combination of a PowerVision PV8630 (USB->parport bridge) and
National Semiconductor LM9830 as used in the HP 4200. Fixed compilation warning.
2005-08-16 18:23:42 +00:00
Henning Geinitz 53fe9ae549 Don't print anything else but the found messages in "-q" mode. 2005-08-16 18:19:41 +00:00
Oliver Schwartz 159782bd7f Make compileable again 2005-08-16 17:19:20 +00:00
Henning Geinitz 921f7d7cbc Added Canon PIXMA MP780 and Lexmark P6250. 2005-08-16 09:32:21 +00:00
Oliver Schwartz 7f9b7c4646 Added temporary debug code for 2480/2580 distinction 2005-08-15 18:56:55 +00:00
Oliver Schwartz 59fc80c118 Added support for Epson 3490/3590 (thanks to Matt Judge) 2005-08-15 18:06:38 +00:00
Gerhard Jaeger a4a88fccbf * doc/plustek/Plustek-USB.changes: Update.
* doc/descriptions/plustek.desc: Updated version number.
* backend/plustek.h. backend/plustek-usb.h backend/plustek-usbcalfile.c
  backend/plustek-usbimg.c backend/plustek-usbmap.c
  backend/plustek-usbdevs.c backend/plustek-usbscan.c: Cleanup.
* backend/plustek.c: Bumped version and build number.
  Activated IPC between reader-process and parent.
* backend/plustek-usbio.c: usbio_DetectLM983x() now returns error if
  register could not be red, usbio_ResetLM983x() checks for reg7
  value before writing.
* backend/plustek-usbhw.c: Added button support for Plustek/Genius
  devices. Changed behaviour of usb_IsScannerReady().
  Added special misc I/O setup for CIS devices (usb_ResetRegisters).
* backend/plustek-usb.c: Minor fix for startup reset.
  Removed unnecessary calls to usbio_ResetLM983x().
* backend/plustek-usbshading.c: Readded kCIS670 to add 5% extra to
  LiDE20 fine calibration.
* backend/plustek-usbcal.c: Tried to use the settings from SANE-1.0.13.
  Added _TWEAK_GAIN to allow increasing GAIN during lamp coarse
  calibration. Added call to speedtest function.
2005-08-15 15:02:22 +00:00
Henning Geinitz 3ae9b03454 Don't exit with error when trying to set inactive options. This especially
happens in connection with geometry options and the v4l backend (bugs #300321,
#301977).
2005-08-14 14:51:06 +00:00
Henning Geinitz 46cfa92d35 Enabled backtracking by default. This is slower but avois bumping the scan head
at the end of the scan area and also missing parts of the scanned
image. Increased safety margin for backtracking. This fixes the "garbled image"
bug. Set default gamma value to 2. Manpage update. Status set to "basic".
2005-08-14 12:59:32 +00:00
Henning Geinitz dccf9e2fa2 Added Changelog-1.0.16 to DISTFILES. 2005-08-14 08:22:32 +00:00
Henning Geinitz 2ce6d33e26 Moved CPPFLAGS definition down to avoid problems with libtool tests for -fPIC. 2005-08-13 16:02:50 +00:00
Henning Geinitz 78a02e266b Removed (backend is now included). 2005-08-13 15:32:12 +00:00
Henning Geinitz 3c5ea794ba Added hp4200 backend. Code from Julien BLACHE's sane-backends-extras debian
package, based on Frank Zago's patches based on Adrian Perez Jorge's code. Fixed
compilation warnings. Fixed bug when no sane device was given. Code indented by
indent -gnu. Added man page.
2005-08-13 15:30:02 +00:00
Henning Geinitz 6953fd4e2c Removed ":new". 2005-08-13 15:18:48 +00:00