Wykres commitów

32 Commity (debdba5b8cfd9326f8b601f98ca09e1b0b96ef20)

Autor SHA1 Wiadomość Data
Stéphane Voltz 8c515798a6 some LiDE 120 support improvement 2015-06-11 21:26:07 +02:00
Stéphane Voltz 128c8931b3 add putative support for LiDE 120 2015-03-17 22:23:21 +01:00
Stéphane Voltz 0f990e4a99 add reverse parameter to gl124_feed 2015-03-02 17:35:20 +01:00
Stéphane Voltz 470594e18b initial support for LiDE 220 2015-02-26 22:26:00 +01:00
Stéphane Voltz aed140364e move to init_scan_regs generic interface 2014-06-02 06:23:17 +02:00
Stéphane Voltz e2dbc97b7f fix 600 to 4800 dpi gray scan geometry
- use correct slope table allowing gray scan speeds
2014-06-02 06:19:29 +02:00
Stéphane Voltz 79f791589e define and update specific LiDE 110 table
- create working values for 1200/2400 gray dpi scans
2014-06-02 06:19:28 +02:00
Stéphane Voltz 23c8bc461b improve 600 dpi gray scans
- define LiDE 110 specific table for 600 dpi
- extend it to reach right dpi
2014-06-02 06:19:28 +02:00
Stéphane Voltz c2e1bd6b4d add init_scan_regs function to internal API
- define a common scan register setting function
- start to move gl124.C to generic motor slope handling
2014-06-02 06:19:28 +02:00
Stéphane Voltz 70bb3e2c60 some whitespaces clean up 2013-07-18 08:18:26 +02:00
Stéphane Voltz 1fa067861c update lide 110 to match scan lide 210
- use lide 210 mode for lide 110
- prepare true gray for GL124
2013-07-17 22:47:42 +02:00
Stéphane Voltz 1c3ec28ab8 improve below 600 dpi scan speed and quality for lide 210
- add half ccd mode for lide 210
2013-07-17 21:24:57 +02:00
Stéphane Voltz ca08a8ba2b switch genesys register address to 16 bits 2013-07-15 07:53:37 +02:00
Stéphane Voltz 730a2ba4e5 define specific LIDE210 sensor and motor instead of using LIDE110 ones 2013-07-04 04:28:09 +02:00
Stéphane Voltz e1a74a94be warnings clean up 2013-01-29 06:43:15 +01:00
Stéphane Voltz 0897a60c60 genesys backend update
- groundwork for gl846 support
- asic init rework
- several refactors
2013-01-28 22:04:37 +01:00
Stéphane Voltz faa758cb24 gl124 led calibration rework 2012-06-04 21:35:10 +02:00
Stéphane Voltz c87bfdc0be align gl124 code on latest gl847 improvements
- slow back home
- feeding
- unintialized dev->skip
2012-05-30 06:39:35 +02:00
Stéphane Voltz 261905e759 GL847/GL124 data interleaving rewrite
- made data interleaving use an order matrix to handle different sensors
2012-05-26 09:41:39 +02:00
Stéphane Voltz 19c43b4184 build number and copyright updates 2012-03-20 21:54:29 +01:00
Stéphane Voltz 11ff6cfaa6 includes cleanup
- remove uneeded includes from genesys.c
- move backend name define to C file for unit testing
2011-11-14 06:16:17 +01:00
Stéphane Voltz 11d8819768 genesys code cleanup
- create an include file for genesys_gl841.c
- simplify includes
- cleanup warnings
2011-11-02 08:40:25 +01:00
Stéphane Voltz e742139517 600 dpi working again for G4050 2011-08-11 21:59:37 +02:00
Stéphane Voltz bda7a84ade use sanei_genesys_compute_dpihw instead of per asic function 2011-07-31 09:00:03 +02:00
Stéphane Voltz 721d388eca swithc slop definitions to uin32t to allow high resolutions 2011-06-07 21:26:19 +02:00
Stéphane Voltz 4f5be8bdb7 gl847 rework progress 2011-06-07 21:26:18 +02:00
Stéphane Voltz 53e28b3cd1 working 2400 dpi mode for LiDE 110 2011-01-13 22:08:31 +01:00
Stéphane Voltz 1f82a765d4 add a wait for head to park function for genesys based scanners 2011-01-12 20:51:32 +01:00
Stéphane Voltz 4da932ad57 2400 dpi for LiDE 110/210 2011-01-11 06:26:41 +01:00
Stéphane Voltz c6c16f4956 LiDE 210 GPIO settings fix 2010-12-19 06:50:13 +01:00
Stéphane Voltz 98c5d9454f LiDE 210 tuning
- dynamic lineart not enabled by default
2010-12-16 22:10:37 +01:00
Stéphane Voltz 3d89a6f880 add new gl124 asic
create a place holder for low level commands

move low level functions to genesys_low.c

GL124 progresses

enable genesys_low debug and add DAC for LiDE 110

gl124 WIP
- gl847 cleanups
- genesys_low refactor
- gl124 starting version

GL124 WIP
- read scancnt/fedcnt,valid words coded
- memory layout coded

LiDE110 WIP

GL 124 WIP
- definition and use of get/set double/triple
- define register names

all mods done, ready to test

set fe OK

GL124 WIP : ready to test scans

GL124 WIP

GL124 WIP
- fixed analog fe issue: don't put afe regs in global set

GL124 : first light at 300 dpi

GL124 WIP
- 300 and 600 uncalibrated mostly ok (x coordinate rounding)
- 150 and 75 OK x-wise, y to be solved

solved rounding errors for gl124

re-add 400, 200 and 100 dpi modes

GL124 : tous x dpi OK

before adding line cropping

GL124 : line cropping almost finished

GL124 WIP : working line deletion

compute step rework

GL124 WIP : high speed table for dpi <= 300

move to scan area working

line skipping fix

new slope table for 600 dpi base

geometry and movement tuned

GL124 WIP : shading calibration almost working

working 600 dpi shading

GL124 : working shading calibration for all modes but 1200 dpi

working 1200 dpi shading

beta 1 of GL124 support

last tuning

update genesys.desc for LiDE 110

motor slope and start area tuning

shading coefficient computing clean up

add support for GL124 based CanoScan LiDE 110

feed almost OK up to 300 dpi

feeding is fixed

all issues fixed
2010-12-14 18:23:23 +01:00