m. allan noah
daa15a1cb1
* backend/fujitsu.c: copy_buffer() needs to count lines, or M309[12]
...
cannot scan in duplex
2009-05-01 15:04:25 +00:00
m. allan noah
dc74e3fa25
* backend/fujitsu.c: ignore errors in scanner_control(),
...
M3091 has not worked since sane 1.0.19, due to this.
2009-04-30 18:25:38 +00:00
m. allan noah
afc0dc6ed3
* acinclude.m4, backend/gphoto2.c, configure, include/sane/config.h.in:
...
deal with upcoming gphoto2 interface change (patch by Chris Bagwell)
* po/sane-backends.nl.po: updates from Martin Kho
2009-04-30 13:58:35 +00:00
m. allan noah
72903a53ac
* po/sane-backends.nl.po: updates from Martin Kho
...
* po/sane-backends.de.po: updates from Burkhard Luck
* po/Makefile.am, po/Makefile.in, po/sane-backends.en_GB.po: new
translation from Andrew Coles
* po/*.po: rebuilt with new strings
2009-04-30 03:06:23 +00:00
Stéphane Voltz
7c88e57144
- doc updates and cleanups
2009-04-29 04:40:58 +00:00
Julien BLACHE
c5991b48a0
/proc/scsi is being deprecated in the Linux
...
kernel; use sysfs for SCSI device enumeration in
sanei_scsi_find_devices() by default, keep
sanei_proc_scsi_find_devices() as a fallback option.
2009-04-28 13:28:25 +00:00
Julien BLACHE
992e66ad5c
Revert encoding changes and fixup last ChangeLog entry.
2009-04-28 13:26:17 +00:00
Gerhard Jaeger
d2d4420a6b
* backend/plustek-usbdevs.c:
...
Tweaked highspeed settings for Epson 1260
2009-04-27 18:36:46 +00:00
Stéphane Voltz
79348f194e
- fix blocking bug due to scanner sharing enabled by default
...
- fix wrong waiting time for warming up
- copyright notices and version updates
2009-04-27 15:29:35 +00:00
Stéphane Voltz
8d67bccbdc
- HP2300 shading calibration fixes
2009-04-27 13:53:33 +00:00
Alessandro Zummo
3d05683f81
fixed TPU warmup retry
2009-04-25 13:55:06 +00:00
Stéphane Voltz
f7b28fccd2
- y scan position fixes for MD6471
...
- shading calibration tuning for MD6471
2009-04-25 06:12:16 +00:00
m. allan noah
5605298bb7
* doc/descriptions/fujitsu.desc: update S1500 status to complete
2009-04-24 00:56:14 +00:00
m. allan noah
089129e82f
* include/sane/sane.h: convert new frame and status to #define
2009-04-23 00:36:14 +00:00
Nicolas Martin
652da9a378
Updated documentation for Pixma MP240, reported to work fine by Nik.
2009-04-21 08:22:20 +00:00
Alex Belkin
739f09d65f
update version number for upcoming rel.
2009-04-21 07:23:15 +00:00
m. allan noah
aafe1ac093
* backend/fujitsu.c, backend/fujitsu.conf.in,
...
doc/descriptions/fujitsu.desc: add S1500 usb ids and status
* backend/canon_dr.c: update credits
* doc/sane-fujitsu.man doc/sane-canon_dr.man: update version numbers,
dates, credits and known issues
* doc/saned.man: remove section about uncontrolled data port range
2009-04-21 01:18:04 +00:00
Alessandro Zummo
70b2085e1b
temporarily disable infrared.
2009-04-21 00:43:05 +00:00
Nicolas Martin
17ce97ac80
Updated documentation for Pixma MP540, reported to work fine by Rogge.
2009-04-17 19:39:37 +00:00
Pierre Willenbrock
0f82af6930
Fix reading/writing calib_channels to/from cache file, bad calib_pixels calculation.
...
This fixes bugs introduced by my previous commit.
2009-04-17 14:02:13 +00:00
Pierre Willenbrock
ad1f7de9e0
Always do shading calibration in color mode on gl841.
...
This removes the need to calibrate for both greyscale and color mode.
2009-04-17 13:03:35 +00:00
Stéphane Voltz
4f526dbb24
- y scan position fixes for gl646 scanners
...
- added a 'clear calibration cache button'
2009-04-16 18:39:23 +00:00
Stéphane Voltz
d32f758ce3
- calibration cache activation for gl646 scanners
2009-04-15 19:24:10 +00:00
m. allan noah
3654ff9d43
* backend/fujitsu.c, doc/descriptions/fujitsu.desc: backend v93
...
- return cmd status for reads of sensor options
* backend/canon_dr.c, doc/descriptions/canon_dr.desc: backend v26
- return cmd status for reads of sensor options
- allow rs to adjust read length for all bad status responses
2009-04-15 13:13:35 +00:00
Stéphane Voltz
a7a759b896
- shading calibration rework for gl646 based scanners
2009-04-14 05:15:29 +00:00
m. allan noah
18e88c02a7
double counting untested scanners bug
2009-04-14 03:54:01 +00:00
Stéphane Voltz
f033f08646
- date and version update
2009-04-13 08:07:45 +00:00
Stéphane Voltz
fc29149914
- conditional handling of SANE_STATUS_WARMING_UP and SANE_STATUS_LOCKED
2009-04-13 06:10:26 +00:00
m. allan noah
9c647bcfe3
* doc/doxygen-sanei.conf.in: update to recent version of doxygen
2009-04-12 20:26:47 +00:00
m. allan noah
0342a63033
Updates to prepare for 1.0.20 release:
...
* configure.in: change version to 1.0.20cvs
* configure: rebuild from configure.in
* include/sane/sane.h: hide API changes (minor, frame and status)
* backend/canon_dr.c, backend/fujitsu.c: SANE_FRAME_JPEG
* backend/coolscan3.c: SANE_FRAME_RGBI
* backend/genesys_gl646.c, backend/genesys_gl841.c: STATUS_HW_LOCKED
* backend/rts8891.c, frontend/scanimage.c: STATUS_WARMING_UP
* backend/pixma_io_sanei.c, backend/xerox_mfp.c,
backend/sane_strstatus.c: STATUS_HW_LOCKED & STATUS_WARMING_UP
* doc/releases.txt: minor updates for new build system
2009-04-12 19:40:31 +00:00
m. allan noah
d11e9363ab
whitespace changes to test commit message
2009-04-08 12:18:23 +00:00
m. allan noah
f8a732000d
whitespace changes to test commit
2009-04-07 20:41:25 +00:00
m. allan noah
0d1202d91b
whitespace change to test cvs commit script
2009-04-07 20:30:29 +00:00
Nicolas Martin
d8b60f0e0d
Updated documentation for i-SENSYS MF4018 support.
2009-04-07 19:59:06 +00:00
Julien BLACHE
605a19c37b
Update for iscan 2.19.0
2009-04-07 08:55:45 +00:00
Nicolas Martin
89cda70783
Added MAC OS X usb interrupt read wrapper for darwin libusb, updated doc
2009-04-05 19:49:41 +00:00
m. allan noah
d1f48b2ce4
* backend/canon_dr.[ch], backend/canon_dr.conf.in: backend v24
...
- fix DR-2510C duplex deinterlacing code
- rewrite sane_read helpers to read until EOF
- update sane_start for scanners that dont use object_position
- dont call sanei_usb_clear_halt() if device is not open
- increase default buffer size to 4 megs
- set buffermode on by default
- hide modes and resolutions that DR-2510C lies about
- read_panel() logs front-end access to sensors instead of timing
- rewrite do_usb_cmd() to use remainder from RS info
* doc/desciptions/canon_dr.desc: backend v24, update DR-2510C comment
2009-04-05 04:46:38 +00:00
Louis Lagendijk
d214d08f1b
2009-03-06 Louis Lagendijk <llagendijk-guest at users.alioth.debian.org>
...
* backend/pixma_bjnp.c
- silenced some debug statements during scanner detections
- increased timeouts to 20 seconds as 10 seconds is apparently
- not enough for the combination of a Mac and an MX850.
2009-03-31 19:07:26 +00:00
Alex Belkin
ba825f1050
compatibility with scanners w/o feeder
2009-03-31 05:49:50 +00:00
Alex Belkin
b4a56b92b6
typo
2009-03-31 05:12:07 +00:00
Alex Belkin
d2d6bc6914
add Xerox Phaser 6110MFP
2009-03-31 05:08:15 +00:00
Julien BLACHE
8c90ce6b75
Fix typos in error messages in sense_handler().
2009-03-28 14:48:08 +00:00
m. allan noah
a4561362b0
* backend/canon_dr.[ch], backend/canon_dr-cmd.h: backend v23
...
- rewrite all image data processing code
- handle more image interlacing formats
- re-enable binary mode on some scanners
- limit some machines to full-width scanning
* doc/desciptions/canon_dr.desc: v23, improved comments
2009-03-28 01:04:02 +00:00
m. allan noah
009c5cd33d
* backend/canon_dr.[ch]: backend v22
...
- add deinterlacing code for DR-2510C in duplex and color
2009-03-26 03:05:18 +00:00
Pierre Willenbrock
ce2fdfbfbe
Add calibration cache
...
The calibration data is stored in the directory $HOME/.sane
2009-03-25 12:57:24 +00:00
m. allan noah
93b880cbd1
* backend/canon_dr.[ch], backend/canon_dr-cmd.h: backend v21
...
- correct rgb padding macro
- skip send_panel and ssm_df commands for DR-20xx scanners
* doc/desciptions/microtek2.desc: add ScanMaker 6400XL
2009-03-24 13:38:32 +00:00
Chris Bagwell
fae74d19a5
Don't include descriptions-external/template.desc. into generated HTML.
2009-03-24 13:36:26 +00:00
Chris Bagwell
f87c4aa108
Don't include doc/descriptions/template.desc. into auto-generated
...
HTML files.
2009-03-24 13:30:12 +00:00
m. allan noah
a50ac53580
* backend/canon_dr.[ch], backend/canon_dr-cmd.h: backend v20
...
- improved macros for inquiry and set window
- shorten inquiry vpd length to match windows driver
- remove status-length config option
- add padded-read config option
- rewrite do_usb_cmd to pad reads and calloc/copy buffers
* backend/canon_dr.conf.in: s/status-length/padded-read/g
2009-03-23 16:49:19 +00:00
m. allan noah
dc278c2e9f
* backend/canon_dr.[ch]: backend v19
...
- pad gray deinterlacing area for DR-2510C
- override tl_x and br_x for fixed width scanners
* doc/descriptions/canon_dr.desc: backend v19, update comments
2009-03-23 01:04:31 +00:00