Wykres commitów

2468 Commity (d4b441310fd20ee704cf3c9093235158726505ca)

Autor SHA1 Wiadomość Data
Henning Geinitz d4b441310f Added Canon CanoScan LiDE 500F. 2005-06-12 14:57:46 +00:00
Henning Geinitz 7dda4a0306 Fixed comments. 2005-06-04 13:45:26 +00:00
Henning Geinitz 04e085c532 New. Listed scanners supported by the new external brother2 backend. 2005-06-04 13:43:03 +00:00
Henning Geinitz 6de5708e4f Added Genius ColorPage-SF600. 2005-06-04 13:33:13 +00:00
Karl Heinz Kremer a245023c10 Added CX-4600 to desc file. 2005-05-31 01:14:55 +00:00
Henning Geinitz 6fd1ee367e Start exposure with the settings from the scanner entry. CIS
Calibration and exposure uses a broader spectrum now. Expsoure
	  limit is increased to 50 loops. Genius Vivid 4x is reported to
	  work so the UNTESTED label is removed now. Visioneer 7300 is
	  reported to work so the UNTESTED label is removed now. Genius
	  ColorPage Vivid 1200XE: Removed UNTESTED label. Fixed
	  resolutions. Adjusted margins. Fixed color order. Fixed
	  linedistance. Adjusted AFE. Mustek ScanExpress 1248 UB: Fixed
	  margins. Adjusted AFE. Adjusted exposure. Adjusted
	  gamma. Changed status to "complete". Mustek BearPaw 2400 CU
	  Plus: Adsusted exposure and AFE parameters. Hopefully stripes
	  and similar trouble are gone now. Mustek BearPaw 1200 CU:
	  Increased exposure to avoid vertical lines. Updated manual page.
2005-05-29 19:58:56 +00:00
Henning Geinitz ceaa2ddade Updated, mostly concerning kernel scanner driver (deprecated). Minor fixes. 2005-05-29 19:55:15 +00:00
Henning Geinitz 95be6202fa Status of Samsung SCX-4100 is "good" asit's reported to work. 2005-05-29 19:52:39 +00:00
Henning Geinitz 350c73aba3 Fixed missing link for Genius ColorPage-Slim 1200 USB2. 2005-05-28 18:56:25 +00:00
Henning Geinitz e75fa70160 Added Avision DS310F. Added link for the UMAX Astra 4000. 2005-05-28 18:42:07 +00:00
Henning Geinitz 03e378e10b Mention RPC codes explicitely and explain what request and reply means. based on
patch from Johannes Berg <johannes@sipsolutions.net>.
2005-05-26 14:28:01 +00:00
Henning Geinitz c63843df35 Mention RPC codes explicitely and explain what request and reply means. based on
patch from Johannes Berg <johannes@sipsolutions.net>.
2005-05-26 09:30:47 +00:00
Jochen Eisinger 66ff43083a 2005-05-25 Jochen Eisinger <jochen@penguin-breeder.org>
* doc/descriptions/mustek_pp.desc: added scanner
2005-05-25 13:24:03 +00:00
Julien BLACHE 2917422aa2 doc/sane-find-scanner.man, doc/gamma4scanimage.man: spelling fixes from A Costa. 2005-05-23 16:44:44 +00:00
Henning Geinitz ebd956bcae Changed status of Medion MD 6471 to "basic". Removed comment about not-existing
backend.
2005-05-22 13:41:49 +00:00
Henning Geinitz cfb5d0856a Added Konica Minolta Dimage 5400 2. Fixed bus type for Mustek 800 II EP. 2005-05-22 13:38:34 +00:00
Oliver Schwartz 649853f7e1 Disabled 2400 DPI for Epson 2480 2005-05-22 11:50:24 +00:00
Henning Geinitz 1b1eb09205 Regenerated translation files. Updated German translation. 2005-05-20 17:31:07 +00:00
Henning Geinitz 7d0d083b8d Mustek BearPaw 1200 CU Plus model 0x21b works now. Fixed firmware and offset
settings. Calibration is not completely ok yet, however.  Code cleanup for
setup_scan (only one function for all chipsets).  Simplified line mode/pixel
mode setting Updated TODO.  Mustek BearPaw 2448 TA Plus is now only "basic". Too
much trouble for "good".  Removed option "fast preview". By default for preview
mode 8 bits/pixel are used.  Fixed indentation.  Full scan really scans from y=0
on gt6816 scanners now.
2005-05-20 17:21:56 +00:00
Henning Geinitz e659b95cc0 Added Kodak i30 and Minolta Dual Scan IV. Updated link to Konica Minolta website. 2005-05-16 13:06:05 +00:00
Henning Geinitz 31b676a0f5 Minor updates and line-wrap fixes. 2005-05-16 13:03:18 +00:00
Frank Zago 6e2052d795 *** empty log message *** 2005-05-15 19:38:56 +00:00
Julien BLACHE e93887d425 libsane.usermap: Added Epson Stylus RX620 (04b8/0811). From Mike Talbot. 2005-05-13 11:00:26 +00:00
Gerhard Jaeger c411be9bd6 * backend/plustek-pp_misc.c: Applied patch (see bug #301605).
* doc/plustek/Plustek-PARPORT.changes: Update.
* backend/plustek-pp.c: Bumped build number.
2005-05-11 14:46:39 +00:00
Gerhard Jaeger b13a55e34c * sanei/sanei_access.c: Added PATH_MAX, in case it's
not defined by any header (i.e. OS/2).
2005-05-10 06:51:57 +00:00
Mattias Ellert 6219f5471c Readme update 2005-05-07 19:08:56 +00:00
Henning Geinitz ea9ad9a396 Plustek OpticSlim 2400: Fixed list of resolutions. That fixed the
preview. Removed "untested" warning. Adjusted scan area.  Updated gt68xx.TODO.
Find firmwares independent of capitalization (bug #301580).
2005-05-07 17:16:30 +00:00
Julien BLACHE 155790c61d libsane.usermap: Added Microtek ScanMaker 3700 (05da/40cb). From Ian Beckwith. 2005-05-07 09:18:09 +00:00
Gerard Klaver c33139cc82 - indent -gnu
- free (devlist) added so memory allocated by sane_get_devices() will be released (bugreport 300128)
- added more DEBUG lines and some small fixes.
2005-05-06 21:12:21 +00:00
Henning Geinitz b3669f8d6e Added options to set the time after which the lamp of the A3 Pro is shut off
and to shut it off immediately.
2005-05-05 17:28:38 +00:00
Henning Geinitz 2cba59f874 Added Dell 922. 2005-05-05 15:53:22 +00:00
Peter Fales 88df3af0bb When no port is specified in the gphoto2.conf config file, an attempt
was being made to strdup() a bad pointer.
2005-05-05 03:52:03 +00:00
Henning Geinitz 486e6b24a9 Fixed link. 2005-04-29 18:22:11 +00:00
Henning Geinitz 3d75c6a2bd Added ScanPartner 600C (bug #301528). 2005-04-29 17:22:43 +00:00
Julien BLACHE 390e9b4884 backend/v4l.c: duplicate capability.name in attach() so that each device is listed with its actual name, not with the name of the last discovered device. Reported by Andreas Hartmann. 2005-04-28 21:18:41 +00:00
Mattias Ellert 23b39a25f1 Missing braces 2005-04-28 12:49:01 +00:00
Gerhard Jaeger 3f893c5e03 * doc/descriptions/plustek.desc: Added UMAX Astranet ia101. 2005-04-27 07:35:10 +00:00
Julien BLACHE 32f60c3e82 Added Epson Stylus CX3650 (04b8/080e). 2005-04-26 11:30:22 +00:00
Gerhard Jaeger a838a5886c * include/sane/sanei_pp.h, sanei/sanei_pp.c: Added outb_eppdata
functionality (thanks to Anderson Lizardo).
* backend/plustek-pp_procs.h, backend/plustek-pp_io.c,
  backend/plustek-pp_misc.c: Fixed compilation problem for kernel
  module with gcc-3.4 compiler.
* doc/plustek/Plustek-PARPORT.changes: Update.
* backend/plustek-pp.c: Bumped build number.
2005-04-25 09:53:43 +00:00
Henning Geinitz e57dff602e Marked Kazuya Fukuda as active. 2005-04-24 10:47:17 +00:00
Henning Geinitz a76c30cfd0 Added Canon PIXMA MP110. 2005-04-24 10:44:11 +00:00
Henning Geinitz 790d3bcc90 Added Primax Colorado 2200 USB. 2005-04-24 10:42:08 +00:00
Henning Geinitz 0003d79b8e Added Mustek TwainScan II SP (bug #301217). 2005-04-24 10:34:52 +00:00
Henning Geinitz 99402cb85b Fixed Minolta Scan Dual III entry (bug #301512). 2005-04-24 10:19:10 +00:00
Julien BLACHE 2f4b6644c9 Add an FAQ section to the LICENSE file. 2005-04-23 18:16:18 +00:00
Julien BLACHE ddf8fb6874 Added Genius ColorPage Vivid3xe (0458/2017), from Ramiro Aceves through Debian BTS. 2005-04-23 15:51:18 +00:00
Gerhard Jaeger e605d0bd27 * doc/plustek/Plustek-USB.changes: Update.
* backend/plustek.c: Bumped build number.
2005-04-18 07:50:25 +00:00
Gerhard Jaeger 5c3bb8a294 * backend/plustek-usbhw.c, backend/plustek-usbscan.c: Fixed
problem, that has been reported in conjunction with backtracking
  and sensor-speedup option.
2005-04-18 07:33:29 +00:00
Henning Geinitz 64c2b9df30 Added and updated several scanners. 2005-04-17 21:36:47 +00:00
Gerard Klaver 9ae13c1e70 -update sanei/sanei_usb.c
-update include/sanei_usb.h
-update frontend/scanimage.c
-update doc/scanimage.man
2005-04-15 21:36:51 +00:00