Wykres commitów

5927 Commity (cebc089532b84ea4e37bb07d5cccf3648568e2cc)

Autor SHA1 Wiadomość Data
Nicolas Martin 399a23cb9f ifaddrs.h header check and increase backend version number 2008-10-18 22:28:47 +00:00
Nicolas Martin f573865c33 ifaddrs.h header check and increase backend version number 2008-10-18 22:26:57 +00:00
Stéphane Voltz 5633288e36 - added 300 dpi scans for HP4400, sensor type 2 2008-10-15 05:01:28 +00:00
Stéphane Voltz 8d3d0f1037 - added 150 dpi scan for HP4400
- added sensor detection for HP4400
2008-10-15 04:36:30 +00:00
Nicolas Martin 391a6b4549 Added Canon's BJNP network protocol support, fix an ADF issue, updated doc and headers 2008-10-14 19:48:59 +00:00
m. allan noah 56ae50027a * doc/descriptions/fujitsu.desc, doc/sane-fujitsu.man: backend v80 2008-10-10 00:51:31 +00:00
m. allan noah 0f3d11f498 * backend/fujitsu.c: backend v80
- front-side endorser uses data ID 0x80
2008-10-09 00:43:06 +00:00
Stéphane Voltz 049d3c644f - fixed a configuration option bug 2008-10-06 04:25:23 +00:00
Nicolas Martin 1aa1677ef2 Changes for ADF simplex and duplex scan, MP970 4800 dpi and TPU scan. 2008-10-05 20:42:19 +00:00
m. allan noah 7fa6ae708c typo in comment 2008-10-03 16:20:36 +00:00
m. allan noah 9371a0c8fb * backend/epjitsu.[ch]: backend v17:
- increase scan height ~1/2 inch due to head offset
- change page length autodetection condition
2008-10-03 15:54:39 +00:00
Stéphane Voltz 7069ba9295 - added a SANE_CURRENT_MINOR define 2008-10-03 04:45:32 +00:00
Stéphane Voltz 0214a5091b - add a 'sensornumber' option to override sensor detection 2008-10-02 19:54:52 +00:00
m. allan noah 5de0ac3014 add iscan 2.12.0 updates 2008-10-02 14:29:00 +00:00
m. allan noah 48e23ca24e * doc/descriptions/fujitsu.desc, backend/fujitsu.conf.in,
backend/fujitsu.[ch], backend/fujitsu-scsi.h: backend v79
- add usb ids for several models
- print additional hardware capability bits
- detect front-side endorser
- disable endorser-side controls if only one side installed
- add quirks for fi-6x70
2008-10-02 04:03:31 +00:00
m. allan noah 7274bfc500 * backend/epjitsu.[ch]: backend v16:
- split fill_frontback_buffers_S300 into 3 functions
- enable threshold_curve option
- add 1-D dynamic binary thresholding code
- remove y-resolution option
- pad 225x200 data to 255x225
2008-10-02 03:38:40 +00:00
Gerhard Jaeger 98de411d6c Added entry for OpticSlim 2400plus 2008-10-01 11:44:54 +00:00
Gerhard Jaeger 2d36b65f55 * doc/descriptions/plustek.desc: Added entry for UT12 devid 0x0013
* doc/descriptions/unsupported.desc: Removed entry for UT12 devid 0x0013
2008-10-01 10:36:28 +00:00
Gerhard Jaeger bb2e71643b Removed entry for UT12 devid 0x0013
Cleanup
2008-10-01 10:36:03 +00:00
Gerhard Jaeger 24f5d10762 Added entry for UT12 devid 0x0013 2008-10-01 10:35:36 +00:00
Stéphane Voltz db0188805e - fix HP4400 head parking 2008-09-26 04:47:54 +00:00
m. allan noah 0bbf8bac04 2008-09-25 m. allan noah <kitno455 a t gmail d o t com>
* backend/epjitsu.[ch], backend/epjitsu-cmd.h: backend v 13, 14 and 15:
        - add working page-height control
        - add working brightness, contrast and threshold controls
        - add disabled threshold curve and geometry controls
        - move initialization code to sane_get_devices, for hotplugging
        - support S300 on USB power
        - support S300 225x200 and 600x600 scans
        - support for automatic paper length detection (parm.lines = -1)
        - expose hardware buttons/sensors as options for S300
        * doc/descriptions/epjitsu.desc: change S300 status to good
2008-09-25 03:15:49 +00:00
m. allan noah ba856d2aec 2008-09-25 m. allan noah <kitno455 a t gmail d o t com>
* include/sane/saneopts.h: underscore not allowed in option names
        * frontend/scanimage.c: fix broken unknown length (-1) binary scans,
          fix invalid tiff height with unknown length scans, fix compiler warn
2008-09-25 02:39:52 +00:00
Stéphane Voltz c2f747a22d - fixed typo in HP4400 sensor detection 2008-09-23 19:22:42 +00:00
Stéphane Voltz 9f081c4508 - head parking fix for HP4400
- 75 dpi support for a sensor varaint of the HP4400
	- better sensor detection at init
2008-09-20 07:00:10 +00:00
Nicolas Martin 5ab0b2024c Changes for MP970 (to be continued), add MX7600 pid (untested yet). 2008-09-13 12:32:52 +00:00
Stéphane Voltz c21bb0ab56 - fix head parking for HP4400
- tune dark calibration for HP4400
2008-09-11 04:38:19 +00:00
Nicolas Martin 286dbd885d Doc update, CCD sensors white lines padding fix, enhance scan area adjustments. 2008-09-07 19:08:25 +00:00
Stéphane Voltz a2cb00cdc3 - minor tweaks for hp4400 support 2008-09-03 04:43:15 +00:00
Nicolas Martin 3a8c2cc40f Some tweaks to have PIXMA MP810 supported by the pixma backend. 2008-09-02 20:56:23 +00:00
Stéphane Voltz 9f60fdf955 - move to configuration framework
- fix GPO value confusion
	- don't reset ASIC anymore
	- some HP2400/G2410 tidbits
2008-08-29 05:13:15 +00:00
m. allan noah 72894d1e98 * doc/descriptions/fujitsu.desc: mark fi-6230 and fi-6240 complete 2008-08-27 17:50:47 +00:00
m. allan noah 08d54b457a * backend/fujitsu.c, doc/descriptions/fujitsu.desc: backend v78
- recent model names (fi-6xxx) dont end in 'C'
- simplify flatbed area overrides
- call scanner_control to change source during sane_start
2008-08-26 17:04:30 +00:00
m. allan noah b9aaa8a469 * backend/fujitsu.c, backend/fujitsu-scsi.h: backend v77
- override flatbed maximum area for fi-6230C and fi-6240C
 - set PF bit in all mode_select(6) CDB's
 - set SANE_CAP_INACTIVE on all disabled options
 - fix bug in mode_select page for sleep timer
2008-08-26 15:29:46 +00:00
Gerhard Jaeger 3a143ee306 Update 2008-08-25 20:41:33 +00:00
Gerhard Jaeger 288ebfff78 Added missing logs 2008-08-25 20:32:22 +00:00
Gerhard Jaeger c297c51e97 Updated 2008-08-25 20:30:43 +00:00
Gerhard Jaeger 8e75357955 Added entry for Strobe XP100 2008-08-25 20:29:56 +00:00
Gerhard Jaeger 8968a4a58a Removed entry for Strobe XP100 2008-08-25 20:29:24 +00:00
Gerhard Jaeger c7b898da9c Fixed name from XP100 to Strobe XP100 2008-08-25 20:23:42 +00:00
Gerhard Jaeger 78413ed072 Added preliminary support for Visioneer XP100
Tweaked entry for LM9831 version of Plustek UT12
2008-08-25 20:17:46 +00:00
Gerhard Jaeger 12680ab414 Update 2008-08-25 20:15:40 +00:00
Gerhard Jaeger 39dabb3a09 Bumped build number 2008-08-25 20:15:11 +00:00
Stéphane Voltz ace0f65863 - calibration update for HP 4400
- 75 dpi scan mode update for HP 4400
2008-08-25 05:36:46 +00:00
m. allan noah ad02a8f1ac set lots of scanners to complete status :) 2008-08-24 02:40:54 +00:00
Stéphane Voltz 58b63ddeb3 - for HP4400 support, add a sensor type filed in device description
and use it in find_origin()
2008-08-21 06:45:13 +00:00
Stéphane Voltz b7db21cf61 - fix for HP4400 init 2008-08-14 05:26:05 +00:00
m. allan noah 852411f3f4 * backend/fujitsu.[ch]: backend v76
- add independent maximum area values for flatbed
- override said values for fi-4220C, fi-4220C2 and fi-5220C
* doc/descriptions/fujitsu.desc: bump version, add 2 untested scanners
2008-08-14 03:56:17 +00:00
Stéphane Voltz bbc7dbd0c9 - improve configuration framework use
- add temporary shading calibration tuning tool
2008-08-11 19:17:28 +00:00
Rene Rebe b975ac1fcd * backend/fujitsu.c, backend/fujitsu.conf.in,
doc/descriptions/fujitsu.desc: backend v75
	- added fi-6230 ID, updated fi-6130, fi-6230 status
2008-08-07 08:21:51 +00:00