Nicolas Martin
399a23cb9f
ifaddrs.h header check and increase backend version number
2008-10-18 22:28:47 +00:00
Nicolas Martin
f573865c33
ifaddrs.h header check and increase backend version number
2008-10-18 22:26:57 +00:00
Stéphane Voltz
5633288e36
- added 300 dpi scans for HP4400, sensor type 2
2008-10-15 05:01:28 +00:00
Stéphane Voltz
8d3d0f1037
- added 150 dpi scan for HP4400
...
- added sensor detection for HP4400
2008-10-15 04:36:30 +00:00
Nicolas Martin
391a6b4549
Added Canon's BJNP network protocol support, fix an ADF issue, updated doc and headers
2008-10-14 19:48:59 +00:00
m. allan noah
56ae50027a
* doc/descriptions/fujitsu.desc, doc/sane-fujitsu.man: backend v80
2008-10-10 00:51:31 +00:00
m. allan noah
0f3d11f498
* backend/fujitsu.c: backend v80
...
- front-side endorser uses data ID 0x80
2008-10-09 00:43:06 +00:00
Stéphane Voltz
049d3c644f
- fixed a configuration option bug
2008-10-06 04:25:23 +00:00
Nicolas Martin
1aa1677ef2
Changes for ADF simplex and duplex scan, MP970 4800 dpi and TPU scan.
2008-10-05 20:42:19 +00:00
m. allan noah
7fa6ae708c
typo in comment
2008-10-03 16:20:36 +00:00
m. allan noah
9371a0c8fb
* backend/epjitsu.[ch]: backend v17:
...
- increase scan height ~1/2 inch due to head offset
- change page length autodetection condition
2008-10-03 15:54:39 +00:00
Stéphane Voltz
7069ba9295
- added a SANE_CURRENT_MINOR define
2008-10-03 04:45:32 +00:00
Stéphane Voltz
0214a5091b
- add a 'sensornumber' option to override sensor detection
2008-10-02 19:54:52 +00:00
m. allan noah
5de0ac3014
add iscan 2.12.0 updates
2008-10-02 14:29:00 +00:00
m. allan noah
48e23ca24e
* doc/descriptions/fujitsu.desc, backend/fujitsu.conf.in,
...
backend/fujitsu.[ch], backend/fujitsu-scsi.h: backend v79
- add usb ids for several models
- print additional hardware capability bits
- detect front-side endorser
- disable endorser-side controls if only one side installed
- add quirks for fi-6x70
2008-10-02 04:03:31 +00:00
m. allan noah
7274bfc500
* backend/epjitsu.[ch]: backend v16:
...
- split fill_frontback_buffers_S300 into 3 functions
- enable threshold_curve option
- add 1-D dynamic binary thresholding code
- remove y-resolution option
- pad 225x200 data to 255x225
2008-10-02 03:38:40 +00:00
Gerhard Jaeger
98de411d6c
Added entry for OpticSlim 2400plus
2008-10-01 11:44:54 +00:00
Gerhard Jaeger
2d36b65f55
* doc/descriptions/plustek.desc: Added entry for UT12 devid 0x0013
...
* doc/descriptions/unsupported.desc: Removed entry for UT12 devid 0x0013
2008-10-01 10:36:28 +00:00
Gerhard Jaeger
bb2e71643b
Removed entry for UT12 devid 0x0013
...
Cleanup
2008-10-01 10:36:03 +00:00
Gerhard Jaeger
24f5d10762
Added entry for UT12 devid 0x0013
2008-10-01 10:35:36 +00:00
Stéphane Voltz
db0188805e
- fix HP4400 head parking
2008-09-26 04:47:54 +00:00
m. allan noah
0bbf8bac04
2008-09-25 m. allan noah <kitno455 a t gmail d o t com>
...
* backend/epjitsu.[ch], backend/epjitsu-cmd.h: backend v 13, 14 and 15:
- add working page-height control
- add working brightness, contrast and threshold controls
- add disabled threshold curve and geometry controls
- move initialization code to sane_get_devices, for hotplugging
- support S300 on USB power
- support S300 225x200 and 600x600 scans
- support for automatic paper length detection (parm.lines = -1)
- expose hardware buttons/sensors as options for S300
* doc/descriptions/epjitsu.desc: change S300 status to good
2008-09-25 03:15:49 +00:00
m. allan noah
ba856d2aec
2008-09-25 m. allan noah <kitno455 a t gmail d o t com>
...
* include/sane/saneopts.h: underscore not allowed in option names
* frontend/scanimage.c: fix broken unknown length (-1) binary scans,
fix invalid tiff height with unknown length scans, fix compiler warn
2008-09-25 02:39:52 +00:00
Stéphane Voltz
c2f747a22d
- fixed typo in HP4400 sensor detection
2008-09-23 19:22:42 +00:00
Stéphane Voltz
9f081c4508
- head parking fix for HP4400
...
- 75 dpi support for a sensor varaint of the HP4400
- better sensor detection at init
2008-09-20 07:00:10 +00:00
Nicolas Martin
5ab0b2024c
Changes for MP970 (to be continued), add MX7600 pid (untested yet).
2008-09-13 12:32:52 +00:00
Stéphane Voltz
c21bb0ab56
- fix head parking for HP4400
...
- tune dark calibration for HP4400
2008-09-11 04:38:19 +00:00
Nicolas Martin
286dbd885d
Doc update, CCD sensors white lines padding fix, enhance scan area adjustments.
2008-09-07 19:08:25 +00:00
Stéphane Voltz
a2cb00cdc3
- minor tweaks for hp4400 support
2008-09-03 04:43:15 +00:00
Nicolas Martin
3a8c2cc40f
Some tweaks to have PIXMA MP810 supported by the pixma backend.
2008-09-02 20:56:23 +00:00
Stéphane Voltz
9f60fdf955
- move to configuration framework
...
- fix GPO value confusion
- don't reset ASIC anymore
- some HP2400/G2410 tidbits
2008-08-29 05:13:15 +00:00
m. allan noah
72894d1e98
* doc/descriptions/fujitsu.desc: mark fi-6230 and fi-6240 complete
2008-08-27 17:50:47 +00:00
m. allan noah
08d54b457a
* backend/fujitsu.c, doc/descriptions/fujitsu.desc: backend v78
...
- recent model names (fi-6xxx) dont end in 'C'
- simplify flatbed area overrides
- call scanner_control to change source during sane_start
2008-08-26 17:04:30 +00:00
m. allan noah
b9aaa8a469
* backend/fujitsu.c, backend/fujitsu-scsi.h: backend v77
...
- override flatbed maximum area for fi-6230C and fi-6240C
- set PF bit in all mode_select(6) CDB's
- set SANE_CAP_INACTIVE on all disabled options
- fix bug in mode_select page for sleep timer
2008-08-26 15:29:46 +00:00
Gerhard Jaeger
3a143ee306
Update
2008-08-25 20:41:33 +00:00
Gerhard Jaeger
288ebfff78
Added missing logs
2008-08-25 20:32:22 +00:00
Gerhard Jaeger
c297c51e97
Updated
2008-08-25 20:30:43 +00:00
Gerhard Jaeger
8e75357955
Added entry for Strobe XP100
2008-08-25 20:29:56 +00:00
Gerhard Jaeger
8968a4a58a
Removed entry for Strobe XP100
2008-08-25 20:29:24 +00:00
Gerhard Jaeger
c7b898da9c
Fixed name from XP100 to Strobe XP100
2008-08-25 20:23:42 +00:00
Gerhard Jaeger
78413ed072
Added preliminary support for Visioneer XP100
...
Tweaked entry for LM9831 version of Plustek UT12
2008-08-25 20:17:46 +00:00
Gerhard Jaeger
12680ab414
Update
2008-08-25 20:15:40 +00:00
Gerhard Jaeger
39dabb3a09
Bumped build number
2008-08-25 20:15:11 +00:00
Stéphane Voltz
ace0f65863
- calibration update for HP 4400
...
- 75 dpi scan mode update for HP 4400
2008-08-25 05:36:46 +00:00
m. allan noah
ad02a8f1ac
set lots of scanners to complete status :)
2008-08-24 02:40:54 +00:00
Stéphane Voltz
58b63ddeb3
- for HP4400 support, add a sensor type filed in device description
...
and use it in find_origin()
2008-08-21 06:45:13 +00:00
Stéphane Voltz
b7db21cf61
- fix for HP4400 init
2008-08-14 05:26:05 +00:00
m. allan noah
852411f3f4
* backend/fujitsu.[ch]: backend v76
...
- add independent maximum area values for flatbed
- override said values for fi-4220C, fi-4220C2 and fi-5220C
* doc/descriptions/fujitsu.desc: bump version, add 2 untested scanners
2008-08-14 03:56:17 +00:00
Stéphane Voltz
bbc7dbd0c9
- improve configuration framework use
...
- add temporary shading calibration tuning tool
2008-08-11 19:17:28 +00:00
Rene Rebe
b975ac1fcd
* backend/fujitsu.c, backend/fujitsu.conf.in,
...
doc/descriptions/fujitsu.desc: backend v75
- added fi-6230 ID, updated fi-6130, fi-6230 status
2008-08-07 08:21:51 +00:00