Wykres commitów

11 Commity (b750f1715c3cf17b5771f033b8d249397c42b0c5)

Autor SHA1 Wiadomość Data
Stéphane Voltz 4133e1b079 fix move paper before scan when required ydpy exceeds base ydpy 2009-11-28 08:04:58 +01:00
Stéphane Voltz fcb86641bf make sheetfed shading correction work for any width
- add pixel_x0 to GT68xx_Params to keep used pixel_x0
- use scan's pixel_x0 and calibration one to compute offset in
  calibration data
- use final scan width for per scan calibration
- compute and use offset when copying from calibration data
2009-11-28 07:29:52 +01:00
Stéphane Voltz 8adddd187e add generic y move to scan area request
- implement reques 0x82 which moves the paper by the amount needed to
  reach the targeted scan area
2009-11-23 05:51:45 +01:00
Henning Geinitz 4b83c2d24c Added Artec Ultima 2000 e+, Nortek Myscan 1200, NeatReceipts Scanalizer
Professional, Genius Colorpage Slim-1200. Name and email address changes.
2007-08-19 13:30:46 +00:00
Henning Geinitz f8d48dc09d Minor modifications to sheet-fed scanner support. 2005-10-16 12:47:37 +00:00
Henning Geinitz fb40be18dc Added support for Plustek OpticSlim M12 (untested). Based on patch from Gerhard
Jaeger <gerhard@gjaeger.de>. Fixed gt68xx homepage links in man page. Changed
minimum version of libusb to 0.1.8.
2005-09-29 18:22:30 +00:00
Henning Geinitz aa209997b7 Genius ColorPage Vivid 1200 X is reported to work. Genius ColorPage Vivid 4 XE
seems to be the same as 4 X, it just doesn't have buttons. Cleanup of .desc
file. Fixed gain setting. Mustek ScanExpress A3 USB 600 dpi color scanning works
now.
2005-09-01 20:01:50 +00:00
Henning Geinitz 38cc925c4b Changed resolution from 75 to 100 dpi and changed 16 bit/color to 12 based on a
user report for the Visioneer OneTouch 7300. Updated .desc. Moved check for
stable lamp to its own function. Mustek ScanExpress A3 USB: Use CIS
calibration. Use lamp warmup. Fixed CCD on GT6801 scanning (color scanning was
broken due to a change in motormode_2.
2005-07-10 20:58:58 +00:00
Henning Geinitz 7d0d083b8d Mustek BearPaw 1200 CU Plus model 0x21b works now. Fixed firmware and offset
settings. Calibration is not completely ok yet, however.  Code cleanup for
setup_scan (only one function for all chipsets).  Simplified line mode/pixel
mode setting Updated TODO.  Mustek BearPaw 2448 TA Plus is now only "basic". Too
much trouble for "good".  Removed option "fast preview". By default for preview
mode 8 bits/pixel are used.  Fixed indentation.  Full scan really scans from y=0
on gt6816 scanners now.
2005-05-20 17:21:56 +00:00
Henning Geinitz 75a39c06d7 Updated to backend version 61. Lots of fixes for coarse calibration, scanning
speed and several scanners. For details, see gt68xx.CHANGES.
2004-06-18 09:49:32 +00:00
Henning Geinitz 492b63060f Added gt68xx backend for scanners based on the Grandtech GT-6801
and GT-8616 chips like The Mustek BearPaw CU, and TA scanners
and some Artec Ultima 2000 clones.
2002-10-25 12:16:15 +00:00