Henning Geinitz
98c866ad27
Deleted.
2005-12-20 17:58:41 +00:00
Henning Geinitz
07757d4c85
Added hp3500 backend which supports the HP ScanJet 3500 series, including the
...
3500C, 3530C and 3570C (patch from Troy Rollo <sane@troy.rollo.name>) (bug
#302687 ).
2005-12-20 17:55:45 +00:00
Henning Geinitz
df2a8b6180
Fixed dynamic loading on current HP/UX systems (bug #302732 ).
2005-12-20 17:15:39 +00:00
Henning Geinitz
349cbb8dca
Added Brother MFC-215C.
2005-12-18 21:13:21 +00:00
Henning Geinitz
1988b77a0d
Changed version to 1.0.17-cvs. Enabled compilation warnings.
2005-12-18 15:59:30 +00:00
Henning Geinitz
58c9271416
List ChangeLog-1.0.17 in DISTFILES.
2005-12-18 15:56:12 +00:00
Henning Geinitz
481ab45ea8
****** Release of sane-backends 1.0.17. End of code freeze ******
2005-12-18 14:43:55 +00:00
Henning Geinitz
739ebe20e0
Disabled compilation warnings. Increased version number.
2005-12-18 14:00:25 +00:00
Henning Geinitz
c69b84852c
Added missing genesys_conv.c and genesys_conv_hlp.c to DISTFILES. Without this
...
change the files wouldn't be part of the archive.
2005-12-18 13:51:51 +00:00
Henning Geinitz
25e5788220
Added Trust Direct WebScan 19200 (reported on sane-devel).
2005-12-18 13:28:27 +00:00
Henning Geinitz
901945fc89
Added link to Lexmark X6170.
2005-12-18 13:16:48 +00:00
Karl Heinz Kremer
463ad7ef64
doc/descriptions/epson.desc: Added a few new scanners based on messages to the sane-devel mailing list.
2005-12-18 01:26:10 +00:00
Henning Geinitz
763db00749
Updated for release.
2005-12-11 18:04:26 +00:00
Henning Geinitz
89a8b56ed3
---- CODE FREEZE FOR SANE 1.0.17 ---
2005-12-11 17:54:53 +00:00
Henning Geinitz
d73e02a34e
Removed HP 3500, 3530, and 3570 (now in hp3500.desc).
2005-12-10 16:03:16 +00:00
Henning Geinitz
a06c8efc8d
Added .desc file for new external backend hp3500 which provides support for the
...
HP ScanJet 3500 series.
2005-12-10 16:01:28 +00:00
Henning Geinitz
7d332297b6
Silenced non-fatal warnings/error messages. Several fixes for avoiding
...
freezes/timeouts after cancelling a scan. Several fixes for warming up of
lamp. Decreased scan width of Plustek OpticPro 1248U.
2005-12-09 11:55:11 +00:00
Henning Geinitz
c8fb998804
Added Lexmark X6170. Removed Brother MFC 4600 USB.
2005-12-09 11:45:39 +00:00
Henning Geinitz
d69c57191e
Added .desc file for (older) external backend for Brother MFC 4600 (USB version).
2005-12-09 11:43:06 +00:00
Gerhard Jaeger
1c0606fbfe
* backend/plustek-pp_tpa.c backend/u12-tpa.c: Fixed nasty
...
compiler warnings.
2005-12-08 11:32:31 +00:00
Henning Geinitz
8ed6601f69
Added .desc file for new external backend for Primax
...
Colorado 2400U.
2005-12-07 19:03:41 +00:00
Henning Geinitz
ade247b0c9
Added Brother MFC-7300c.
2005-12-07 18:42:21 +00:00
Gerhard Jaeger
1ecd3836c4
* sanei/sanei_acces.c: Fixed problem, when the device name contains
...
one or more path-separators. These characters are now converted.
The problem occurs on 2.4 based installations as well as on OpenBSD.
2005-12-07 13:50:04 +00:00
Stéphane Voltz
61332ee42b
- removed an left-over from an experiment
2005-12-06 21:29:14 +00:00
Stéphane Voltz
a75db62b86
- added AFE int in powersave
...
- fixed timeout on first scan
2005-12-06 20:50:21 +00:00
Henning Geinitz
9ddf8d1845
Added Epson Perfection 3490.
2005-12-06 15:15:18 +00:00
Henning Geinitz
3de9f68366
Marked Fred Odendaal as active maintainer.
2005-12-06 12:05:28 +00:00
Henning Geinitz
f1b29682ac
Changed status of Canon LiDE 50 and 60 to "good". Added comment for untested
...
LiDE 40 to report any success/failure.
2005-12-06 10:50:07 +00:00
Henning Geinitz
24ba51dc1e
Enabled Canon LiDE 60 which was disabled for safety reasons. Bugs are fixed now.
2005-12-06 10:34:15 +00:00
Rene Rebe
0c5da94b17
fixed more typos in comments and debug output, removed obsolete
...
options from the parser, example avision.conf and manual page.
Fixed 12 Bit gray and color modes to actually work as well as
software CCD line-difference correction. Minimal scan resolutions
have been slightly adapted for some ASICs.
2005-12-05 23:27:22 +00:00
Pierre Willenbrock
fb446b0804
* backend/genesys.c: removed usage of current_setup in functions
...
where it is not necessarily initialized. Modified shading
calibration to not use fixed stripe sizes. Fixed memory
corruption while calculating shading data. Fixed read sizes to
be multiples of 256. Fixed stagger/line distance
correction. Fixed line shrinking to correctly update data
buffers. Bumped BUILD number.
* backend/genesys.c backend/genesys_conv.c: Added gray to lineart
conversion.
* backend/genesys.c backend/genesys_conv_hlp.c: Modified calling
parameters to stagger/line distance correction filter to better
describe its inner working.
* backend/genesys_devices.c: Slowed down motor timings for
LiDE 35/40/50/60. Removed untested message for LiDE 35/40/50/60.
* backend/genesys_gl646.c: Fixed bug for odd pixel count. Added
support for gray to lineart conversion.
* backend/genesys_gl841.c: Fixed words_per_line calculation. Added
support for gray to lineart conversion(not used). Fixed problem
with scanners not backtracking while scanning calibration area
leading to scanning part of document area.
2005-12-05 20:50:57 +00:00
Oliver Schwartz
2c7d3ea4d8
Small bugfix for Benq 5150
2005-12-05 20:38:23 +00:00
Henning Geinitz
ac62271c28
Added Canon PIXMA MP170.
2005-12-05 16:58:20 +00:00
Rene Rebe
dff12fc90b
* backend/avision.c backend/avision.h: updated the Avision backend
...
from BUILD 167 to 179, including support for HP 5370, AV600U,
AV210C2, AV220C2, et. al. The USB i/o paths got hardened, and a
lot of fixes as well es enhancements and optimizations where added
and a lot of typos, mostly in debug output and comments, got fixed.
The "Line Art" mode was renamed to "Lineart" to match the other
backends.
2005-12-04 21:29:22 +00:00
Karl Heinz Kremer
a8e7f2ddee
backend/epson_usb.c: Added id for CX4200
2005-12-04 17:14:17 +00:00
Oliver Schwartz
fddbe1342c
Some fixes for Benq 5150
2005-12-04 15:03:00 +00:00
Peter Fales
8e0b9f0e3c
Cosmetic changes to gphoto2 debug messages
2005-12-03 18:23:55 +00:00
Oliver Schwartz
f5c6a9c8df
Change SnapScan version number to 1.4.50
2005-12-02 19:15:42 +00:00
Oliver Schwartz
39575524dc
Another fix for lineart mode for the Epson 3490 @ 3200 DPI
2005-12-02 19:12:54 +00:00
Henning Geinitz
ed6dc539dc
Added link for Corex Cardscan 500.
2005-12-01 18:34:02 +00:00
Henning Geinitz
c458e3fe30
Added Epson Stylus CX4200.
2005-11-30 18:58:12 +00:00
Henning Geinitz
3f9565a669
Added UMAX Astra 4100.
2005-11-30 18:43:17 +00:00
Jochen Eisinger
eb446e2de1
2005-11-28 Jochen Eisinger <jochen@penguin-breeder.org>
...
* sanei/sanei_pa4s2.c: incorrect test of a bit mask.
2005-11-28 22:24:17 +00:00
Stéphane Voltz
83880f74c2
- ifdef'ed forgottent debug statements
2005-11-28 20:59:30 +00:00
Stéphane Voltz
0b6469ec26
- fix 'blue tint' on scanning area borders for 1220P/2000P
2005-11-28 20:49:57 +00:00
Oliver Schwartz
ba7f55d72f
Fix for lineart mode of Epson 3490 @ 3200 DPI
2005-11-28 19:28:29 +00:00
Oliver Schwartz
dcfdf8b121
Fix inquiry bug for Benq 5000
2005-11-26 18:53:03 +00:00
Mattias Ellert
13072119bf
Use default firmware dir for man pages
2005-11-26 12:28:47 +00:00
Mattias Ellert
3122a93ea4
Use default firmware dirs in config files
2005-11-26 06:14:30 +00:00
Ulrich Deiters
cd3365e8d6
Ulrich Deiters: fixed unintialized variable in backend/canon-sane.c
2005-11-25 22:32:52 +00:00