Wykres commitów

6 Commity (9785664eed7fd7ebbf436d921b1bbb1247513f0d)

Autor SHA1 Wiadomość Data
Henning Geinitz 2470018e5c Added point about sane_init results != SANE_STATUS_GOOD.
Henning Meier-Geinitz <henning@meier-geinitz.de>
2001-05-13 15:57:57 +00:00
Petter Reinholdtsen 514da4e0d4 Wiped old repository. Imported v1.0.1. 1999-08-09 18:06:01 +00:00
Henning Geinitz e0e06582eb 2000-11-08 Henning Meier-Geinitz <hmg@gmx.de>
* TODO: Updated. Added entries for viceo backend and addition to hp
	  backend. Updated entries about the include issue. Added point about
	  additional options for pnm backend, install problem of libsane.la,
	  and some build problems and the --without-x problem. Some more
	  details for detecting older SANE versions.

	* LEVEL2: Added entry about sending messages from backend to frontend.
	  Removed entry about image polarity.

	* backend/mustek.c backend/mustek.h backend/mustek.CHANGES
	  backend/mustek.desc: Update to Mustek backend 1.0-99. Better
	  transparency adapter support for ScanExpress scanners. Changed
	  color support for ScanExpress scanners (faster at some resolutions
	  now). Paragon 1200 SP color mode should work now without garbage at
	  the end of an image. Some bugfixes. Details in
	  backend/mustek.CHANGES.
1994-11-08 19:37:13 +00:00
Henning Geinitz 8835903b21 2000-09-24 Henning Meier-Geinitz <hmg@gmx.de>
* backend/mustek.*: Update to Mustek backend 1.0-97. This is a
       	  development version and is only tested for three-pass scanners.
  	  Added support for Paragon 1200 SP Pro and ScanExpress A3 SP.
  	  Removed detection of " C04" and " C12" (don't seem to exist).
  	  Changed SCSI request scheme. Sane_read can read more than 4096
 	  bytes from pipe. Minimum dpi is 30 now. Fixed LD correction for
 	  Paragon 1200SP 1.06 and 1.11.  Read SCSI buffer into big block and
 	  do LD after that for Paragon one-pass scanners. New option
 	  "blocksize" in mustek.conf. Better detection of the scanner type
 	  (three-pass, Paragon I, ...). Fixed possible segmentation faults
 	  in Paragon 600 II N LD code, scsi_sense_wait_ready and
 	  sense_handler. Decreased maximum scan size of Paragon 800 II
 	  SP. For three-pass scanners: fixed stop_scan and speed code, scan
 	  area is in pixels now, added RGB brightness and contrast, use
 	  +-100% for brightness and contrast. Return SANE_STATUS_CANCELLED
 	  when scan was cancelled. Option "force backtracking" is enabled by
 	  default, "scan speed" is set to "fastest". Added option
 	  "force-warn" for mustek.conf.  Rewrote halftone mode. Better error
 	  handling and more debug output.
	* TODO: Clarified point about image data polarity. Moved point about
	  xscanimage not updating the progress bar for 3pass scanners to
	  frontend section. Removed umax entry in "frontends". Removed entry
	  about alpha channel (was added to LEVEL2 file).
	* LEVEL2: Add point about image data polarity.
	* frontend/scanimage.c: Removed some warnings.
2000-09-24 19:38:35 +00:00
Henning Geinitz 41e4d874f9 2000-09-18 Henning Meier-Geinitz <hmg@gmx.de>
* README: Removed comment about xscanimage error message. Added
          comment about find-scanner (may find scanners not supported by
          SANE).
	* tools/README: Added comment about find-scanner and some lines
 	  about sane-desc.el and sane-config.
	* tools/find-scanner.c: Added comment about scanners not supported
 	  by SANE. Removed some warnings.
	* TODO LEVEL2: Removed xscanimage error comment from TODO and moved
 	  ideas for SANE 2.0 from TODO to LEVEL2.
2000-09-18 18:20:41 +00:00
Petter Reinholdtsen c1d18c4e09 Initial revision 1999-08-09 18:05:59 +00:00