- don't center window when using flatbed
- improve request sense error messages
- enable flatbed for all known models
- ad usb ids for DR-6030C, CR-135i & CR-190i
- moved DR-2020U to unsupported.desc
- use average instead of min/max for fine offset and gain
- rewrite supported resolution list as x and y arrays
- merge x and y resolution options into single option
- move scan params into two new structs, s->u and s->s
- sane_get_parameters() just returns values from s->u
- dont call wait_scanner() in object_position()
- dont call ssm_*() from option handler
- refactor sane_start()
- read_from_buffer() can workaround missing res, modes and cropping
- set most DR-2xxx machines to use the read_from_buffer workarounds
- set default threshold to 90
- add option for button #3 of some machines
- don't eject paper during init
- add DR-2010 quirks
- switch counter to HARD_SELECT, not SOFT
doc/descriptions/fujitsu.desc: add S1500 usb ids and status
* backend/canon_dr.c: update credits
* doc/sane-fujitsu.man doc/sane-canon_dr.man: update version numbers,
dates, credits and known issues
* doc/saned.man: remove section about uncontrolled data port range
- rename read/send_counter to read/send_panel
- enable control panel during init
- add options for all buttons
- call TUR twice in wait_scanner(), even if first succeeds
- disable rif
- enable brightness/contrast/threshold options
* doc/descriptions/canon_dr.desc, doc/sane-canon_dr.man: backend v8