Wykres commitów

22 Commity (88acee2eeecf65119e0730c81970971109559d50)

Autor SHA1 Wiadomość Data
Henning Geinitz 93d43e0be8 Increased number limit of scanners that can work with this backend to 50. Added
support for Genius ColorPage Vivid 1200 X (untested).
2005-08-20 17:54:34 +00:00
Henning Geinitz ed68c27986 Fixed typos. Added Packard Bell Diamond 2450 to .conf and changed status to
"good". Avoid error message when closing scanner. Don't print max_white warning
when debugging is not enabled.
2004-10-11 19:45:08 +00:00
Henning Geinitz f5aaa34eed Updates of supported scanners. 2004-10-02 16:21:37 +00:00
Henning Geinitz 42aab25d25 Fixed firmware name for Mustek 1248 UB. Changed status to basic. Removed
"unsupported" warning.  Added workaround for shared memory compilation problem
on Windows. It's now possible to add a new vendor/product id line to gt68xx.conf
to test yet unsupported scanners without changing the source code.
2004-09-03 14:06:19 +00:00
Henning Geinitz b600c81c26 Added Mustek ScanExpress 1248 UB and new version of Mustek BearPaw 1200 CU Plus. 2004-08-08 10:00:02 +00:00
Henning Geinitz c187441e94 Minor fixes for Mustek A3 USB, Genius ColorPage Vivid4 and Mustek BearPaw 2448
CS/TA Plus.
2004-04-10 17:30:36 +00:00
Henning Geinitz 3593f24a3d Added BGR color order for pixel mode. Plustek OpticPro U16B works
in color mode now. Made 600 dpi mode for Mustek BearPaw 2400 TA
	  Plus a bit faster. Changed Mustek ScanExpress A3 linedistance
	  correction. Added detection of Visioneer Onetouch 7300.
2004-04-04 18:59:49 +00:00
Henning Geinitz aafcfe6a8e Genius Vivid 4xe now has color order RGB. Removed 50 dpi for Mustek BearPaw 2448
as that resolution doesn't work. Make sure that the lamp of the Mustek A3 USB
gets warmed up. It's a CIS scanner with a lamp. That code is untested. Full scan
starts scanning from the start position of the white strip now. Added detection
for Genius Vivid 1200 EX. Fixed product id of Mustek BearPaw 2448 TA Plus. Other
minor updates.
2004-03-19 18:55:35 +00:00
Henning Geinitz 820b9ba269 Added basic support for Plustek OpticSlim 2400. Fixed calibration debug output. 2004-02-10 19:02:03 +00:00
Henning Geinitz 6026b31f36 Debug options are only enabled if the debug level is 1 and higher. Added product
id 0x0402 for Plustek U16B.
2004-01-19 17:35:57 +00:00
Henning Geinitz a4dc00b0ed Fixed a bug in the stop scan function for Plustek U16b. Added support for Genius
Vivid4xe.
2004-01-05 18:16:04 +00:00
Henning Geinitz 0ed2b19fd7 Added Mustek BearPaw 2448 TA Plus. Added special command set for Plustek
U16B. Added Plug-n-Scan 2400 M(T) to list of devices. No positive report yet.
Used request for memory writes and reads instead of a fixed value of 0x04. Set
Genius Vivid4x to GT6816. Untested. All changes have not been tested on their
respective scanners yet.  New version: 1.0.50.
2003-11-23 21:14:43 +00:00
Henning Geinitz 4de7e23e89 Added detection of Genius Vivid 4x. It won't work out-of-the-box, however. CCD coarse calib
shouldn't run into an endless loop anymore. Plustek 1248U is much faster now.
2003-09-30 17:37:56 +00:00
Gerhard Jaeger dbcb3c853f Added Plustek OpticSlim 1200 to gt68xx backend. 2003-09-30 06:48:42 +00:00
Henning Geinitz d5ce45d9c5 Added Fujitsu 1200CUS to man page, .conf and .desc. Changed .conf file to be
more readable.  Added RevScan 19200i to .conf file.  Added Plustek U16B to
.desc and .conf, updated UT16B.
2003-07-25 07:41:58 +00:00
Henning Geinitz 05c12190be Added Genius 3x as working scanner, removed testing flag. Added Artec 2000 e+
to manpage. Added detection for the Plustek OpticPro U16B.
2003-04-27 12:43:43 +00:00
Henning Geinitz 4b00890161 Added Genius Colorpage Vivid3xe. Added request_type and request fields to the
command set. Request is 0x01 or 0x04.
2003-02-27 17:31:52 +00:00
Henning Geinitz a0251b6cc1 Added vid/pid 0x07b3/0x0400 to gt68xx.conf also. Added indormation about
Medion 4394. Mention ma1509 backend. Fix segfault when calling sane_open with
an empty device name.
2003-02-22 15:34:51 +00:00
Henning Geinitz 9f0d82980b Updated manpage and .desc concerning Lexmark X70. Updated manpage concerning
kernel 2.4.21-pre3 containing the 1-endpoint fix. Fixed A3 USB resolution
setting. Updated A3 USB margins (Pedro Morais <morais@inocam.com>). Added
detection of Genius Colorpage Vivid3x.  It's unknown if it works. Updated
.desc file. Don't print calib line warnings by default.
2003-01-09 18:05:01 +00:00
Henning Geinitz 7f699acfe3 Coarse calibration for first scan only" is off by default now. Added gamma
table factor option (SANE_CAP_EMULATED). Setup gamma to 2.0 by default.  Fixed
(hopefully) sigpipe when cancelling. No geometry quantization anymore (not
necessary). Plustek 1248U: do linemode for every resolution, fix color
correction. Added comments for every Model member in gt68xx_devices.  Added
Plustek UT16B and Genius Vivid3x to .desc. Added implementation for inverted
offset for CCD scanners. Added Mustek ScanExpress 2400 USB. Well, at least
it's detected. Added NEW marker to .desc.
2002-12-08 21:00:31 +00:00
Henning Geinitz 4ef48fd6e6 Added basic support for Plustek OpticPro 1248U (from Gerhard Jaeger
<gerhard@gjaeger.de>). Removed 50 and 1200 dpi from Lexmark X73.  Backend
status is BETA now.
2002-11-13 17:45:24 +00:00
Henning Geinitz 492b63060f Added gt68xx backend for scanners based on the Grandtech GT-6801
and GT-8616 chips like The Mustek BearPaw CU, and TA scanners
and some Artec Ultima 2000 clones.
2002-10-25 12:16:15 +00:00